• Title/Summary/Keyword: 저수조

Search Result 97, Processing Time 0.036 seconds

Development of Wireless Integrated System for Managing Water Tank (저수조 무선 통합 관리 시스템 개발)

  • Jung Kyung-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.6
    • /
    • pp.16-25
    • /
    • 2006
  • Most water tanks operating have been managed by people's five senses. A human material resource have been wasted awfully at this. In the present study, we suggest the wireless integrated system for managing water tank of reducing the wastage human resources and on-line real time managing efforts of water tanks. Water level sensor works the pump sending the data from water tank control to the wireless control on sensing water level. At this time, every kind data which happens in the water tank transmits the line transmission modem. Data to be received from the line transmission modem is stored at the database after we record the logs by each hour. We display the result to the web pages, after checking the pump motion, the pump error, the water level, the solar battery error, the chemicals, and the telephone line to the foundation data to be saved. Furthermore, this paper suggests empirical applications of the proposed wireless integrated system for managing water tank in order to verify its feasibility.

  • PDF

Reservoir Tank Wireless Integrated Management using Information Filtering (정보 필터링을 이용한 저수조 무선 통합 관리)

  • Yu, Ki-Youp;Kouh, Hoon-Joon;Chung, Kyung-Yong;Rim, Kee-Wook;Lee, Jung-Hyun
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.787-791
    • /
    • 2009
  • In this paper, we proposed the reservoir tank wireless integrated management using information filtering for improving the water quality and on-line managing efforts of reservoir tanks. Reservoir tank level sensor works the pump sending the data from reservoir tank control to the wireless control on sensing water level. At this time, every kind data which happens in the water tank transmits the line transmission modem. The data to be received from the line transmission modem is stored at the database after we record the logs by each hour. The proposed method defined the context and environment of the reservoir tank and predicted the profited service according to the pump motion, the solar battery, the chemicals, the water level, the line, and the modem using information filtering. we plan to conduct the proposed method to verify the adequacy and the validity of reservoir tank wireless integrated management using the information filtering.

  • PDF

ECO-Friendly Reservoir Tank Management using Prediction for Improved Water Quality (수질향상을 위해 예측을 이용한 환경 친화적인 저수조 관리)

  • Chung, Kyung-Yong;Jo, Sun-Moon
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.9-16
    • /
    • 2009
  • According to the construction of infrastructure for the water resource management services, the importance of the eco-friendly reservoir tank management is being spotlighted. In this paper, we proposed the eco-friendly reservoir tank management using prediction for improving the water quality and on-line managing efforts of reservoir tanks. The proposed method defined the context and environment of the reservoir tank and predicted the profited service according to the pump motion, the solar battery, the chemicals, the water level, the telephone line, and the modem using collaborative filtering. To evaluate the performance of the eco-friendly reservoir tank management system using prediction, we conducted sample T-tests so as to verify usefulness. This evaluation found that the difference of satisfaction by service was statistically meaningful, and showed high satisfaction. Accordingly, the satisfaction and the quality of services will be improved the efficient prediction by supporting the context information as well as the environment information.

A Study on performance of geothermal heatpump using domestic supply water source and geothermal source during winter (상수도열원과 지열원을 이용한 동절기 지열히트펌프 성능평가에 대한 연구)

  • Lee, Byoungdoo;Lee, Sejin;Lee, Daewoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.194.1-194.1
    • /
    • 2011
  • 본 연구에서는 지열히트펌프 시스템의 열원으로써 지열이외에 건축물의 미활용 에너지라고 할 수 있는 상수도의 에너지를 활용하여 지중열교환기의 천공길이를 줄이는 것이 주요 목적이며, 또한 건물의 미활용에너지를 냉난방에너지원으로써 이용 가능한 것을 보여주는 것에 있다. 실험은 4인 가족기준으로 3RT 용량의 히트펌프를 설치하고 인당 평균 177 liter/day 기준으로 하루에 약 710 liter/day의 물을 사용하는 것으로 가정하였다(환경부 2007년 상수도 통계값). 시간당 가정내에서 사용하는 물량은 일정하지 않아 일일 8시간 사용하는 것으로 하여 약 1.5 LPM 으로 실험하였다. 저수조의 크기 및 지열 히트펌프의 열원으로써 사용가능한 열량을 계산하기 위해 CFD 시물레이션을 수행하였다. CFD의 결과 상수도를 급수하기 위한 저수조의 크기는 $2m^3$로 결정하였으며 이때 열원으로써 사용가능한 열량은 약 0.7RT였다. 48시간의 실험기간 동안 저수조를 통해 얻은 열원은 0.6RT 였으며 100m의 지중열교환기를 통해 얻은 열원은 2RT 였다. 히트펌프 자체의 난방 COP는 평균 4.2를 나타내었으며 펌프등의 소비전력을 포함한 System COP는 4.0 나타내었다. 이번 연구를 통해 건물의 미활용에너지인 저수조의 물을 이용하여 지열히트펌프의 열원으로써 이용 가능하며 기존의 지열히트펌프 시스템대비 천공길이 단축, 시공비 저감이 가능한 것을 볼 수 있었다.

  • PDF

Volume Estimation Method for Greenhouse Rainwater Tank (온실 빗물 저수조의 용량산정 방법)

  • Seo, Chan Joo;Koo, Ja-Kong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.2
    • /
    • pp.31-39
    • /
    • 2016
  • Due to the temporal variation of inflow/outflow, the water tank is needed. For the calculation of water tank capacity, the absolute difference between cumulative amounts of supply(e.g., rainfall) and demand(e.g.,watering) is used. No matter the (-) and (+) the absolute maximum capacity of the subtraction is calculated as the capacity. In this paper, using rainfall and watering of greenhouse facilities, it is proved that the non-linear supply or demand can be applied, and it is proved also that the greater non-linear variation case. And as the time interval for monitoring is decreased, the basin or tank volume are increased, with approximately 10 days as the critical monitoring interval for the annual natural rainfall event.

Effective Water Pollution Management using Reservoir Tank Automatic Classification (저수조 자동 분류를 이용한 효과적인 수질 오염 관리)

  • Chung, Kyung-Yong;Jun, In-Ja
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.8
    • /
    • pp.1-8
    • /
    • 2009
  • With the development of IT convergence technology and the construction of master plan for the four rivers restoration of the government, the importance of the eco-friendly water pollution management is being spotlighted. In this paper, we proposed the effective water pollution management using the reservoir tank automatic classification for improving the water quality and on-line managing efforts of ceo-friendly reservoir tanks. The proposed method defined the seven factors of water pollution evaluation and managed the water pollution according to hydrogen ion concentration(pH), chemical oxygen demand(COD), suspend solid(SS), dissolved oxygen(DO), count of coliform group(MPN), total phosphorus(T-P), and total nitrogen(T-N) using the sensors. We measured the values for the seven factors from the reservoir tank and normalized to ranging from 1 to 9. To evaluate the performance of the water pollution management using the reservoir tank automatic classification, we conducted F-measure so as to verify usefulness. This evaluation found that the difference of satisfaction by the traditional system was statistically meaningful.

Material Development of Eco Water Tank with High Density Polyethylene and Low-temperature Concrete (친환경 저수조를 위한 고밀도 폴리에틸렌과 저열성 콘크리트 합성재료 개발)

  • Chang, Chun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.133-140
    • /
    • 2010
  • The purpose of this study is to evaluate the new eco water tank which is made of high density polyethylene and concrete with low temperature cement. The strength and failure mode of eco water tank was examined through tensile test with mixture of concrete and HDPE, temperature monitoring for various kind of concrete, admixture contains etc. The strength and failure mode were examined through tensile test with mixture of concrete and HDPE, temperature monitering for different kinds of concrete, strength test with different admixtures etc. It was found that shear connector between concrete and HDPE effects significantly contributed to the combined structures. ㄱ type shear connector results in tensile strength of up to 40% compared to that of V type shear connector. Based on test result, the new eco composite tank improved the stability and safety the old one and demonstrated the applicability and capability.

A Review Study on Major Factors Influencing Chlorine Disappearances in Water Storage Tanks (저수조 내 잔류염소 감소에 미치는 주요 영향 인자에 관한 문헌연구)

  • Noh, Yoorae;Kim, Sang-Hyo;Choi, Sung-Uk;Park, Joonhong
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.63-75
    • /
    • 2016
  • For safe water supply, residual chlorine has to be maintained in tap-water above a certain level from drinking water treatment plants to the final tap-water end-point. However, according to the current literature, approximately 30-60% of residual chlorine is being lost during the whole water supply pathways. The losses of residual chlorine may have been attributed to the current tendency for water supply managers to reduce chlorine dosage in drinking water treatment plants, aqueous phase decomposition of residual chlorine in supply pipes, accelerated chlorine decomposition at a high temperature during summer, leakage or losses of residual chlorine from old water supply pipes, and disappearances of residual chlorine in water storage tanks. Because of these, it is difficult to rule out the possibility that residual chlorine concentrations become lower than a regulatory level. In addition, it is concerned that the regulatory satisfaction of residual chlorine in water storage tanks can not always be guaranteed by using the current design method in which only storage capacity and/or hydraulic retention time are simply used as design factors, without considering other physico-chemical processes involved in chlorine disappearances in water storage tank. To circumvent the limitations of the current design method, mathematical models for aqueous chlorine decomposition, sorption of chlorine into wall surface, and mass-transfer into air-phase via evaporation were selected from literature, and residual chlorine reduction behavior in water storage tanks was numerically simulated. The model simulation revealed that the major factors influencing residual chlorine disappearances in water storage tanks are the water quality (organic pollutant concentration) of tap-water entering into a storage tank, the hydraulic dispersion developed by inflow of tap-water into a water storage tank, and sorption capacity onto the wall of a water storage tank. The findings from his work provide useful information in developing novel design and technology for minimizing residual chlorine disappearances in water storage tanks.

수도직결 겸용 저수조 급수방식

  • 박정범
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.30 no.3
    • /
    • pp.15-20
    • /
    • 2001
  • 음용수에 대한 세계 각국의 기준과 현행 급수방식중 수도직결 겸용 저수조 급수방식 적용의 필요성 및 현황, 수질 개선방법과 관리지침을 중심으로 기술한다.

  • PDF

IoT-based Water Tank Management System for Real-time Monitoring and Controling (실시간 관측 및 제어가 가능한 IoT 저수조 관리 시스템)

  • Kwon, Min-Seo;Gim, U-Ju;Lee, Jae-Jun;Jo, Ohyun
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.6
    • /
    • pp.217-223
    • /
    • 2018
  • Real-time controllability has been a major challenge that should be addressed to ascertain the practical usage of the management systems. In this regards, for the first time, we proposed and implemented an IoT(Internet of Things)-based water tank system to improve convenience and efficiency. The reservoir can be effectively controlled by notifying the user if the condition of the reservoir is unstable. The proposed system consists of embedded H/W unit for sensor data measuring and controling, application S/W for deployment of management server via web and mobile app, and efficient database structure for managing and monitoring statistics. And machine learning algorithms can be applied for further improvements of efficiency in practice.