• Title/Summary/Keyword: 저선량방사선

Search Result 373, Processing Time 0.026 seconds

Synergistic Effects of Low Dose Gamma Irradiation and Growth Regulators on Seed Germination, Growth and Photosynthesis in Rice (Oryza sativa L.) (벼의 종자 발아와 생육 및 광합성에 대한 저선량 감마선과 생장조절물질의 상승작용 효과)

  • Baek Myung-Hwa;Chung Byung Yeoup;Kim Jin-Hong;Wi Seung Gon;Kim Jae-Sung;Lee In-Jung
    • Korean Journal of Environmental Biology
    • /
    • v.23 no.1
    • /
    • pp.64-70
    • /
    • 2005
  • To investigate the synergistic effects of low dose gamma irradiation and growth regulators on the growth and photosynthesis in rice (Oryza sativa L.), laboratory and greenhouse experiments were conducted using 4-year-old rice seeds. In the laboratory experiment, the germination rate was increased in 0.001 ppm IBA treatment, showing the synergistic effect of gamma irradiation and growth regulators. The seedling growth was increased by treatment of GA₃ and IBA, the irradiated groups having higher than the non-irradiated ones. Particularly, it was remarkable in 0.001 ppm IBA. In greenhouse experiment, seedling growth was increased in response to a combination of gamma irradiation and 0.001 ppm IBA. Effective quantum yield of PSⅡ(Ф/sub PSⅡ/) and photochemical quenching (qP) were increased, while non-photochemical quenching (qN) was decreased by 0.001 ppm IBA. A synergistic effect of gamma irradiation and IBA was only found in seedling growth. The present results suggest that low dose gamma irradiation and growth regulator could synergistically stimulate seedling growth.

Dose Reduction According to the Exposure Condition in Intervention Procedure : Focus on the Change of Dose Area and Image Quality (인터벤션 시 방사선조사 조건에 따른 선량감소 : 면적선량과 영상화질 변화를 중심으로)

  • Hwang, Jun-Ho;Jung, Ku-Min;Kim, Hyun-Soo;Kang, Byung-Sam;Lee, Kyung-Bae
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.393-400
    • /
    • 2017
  • The purpose of this study is to suggest a method to reduce the dose by Analyzing the dose area product (DAP) and image quality according to the change of tube current using NEMA Phantom. The spatial resolution and low contrast resolution were used as evaluation criteria in addition to signal to noise ratio (SNR) and contrast to noise ratio (CNR), which are important image quality parameters of intervention. Tube voltage was fixed at 80 kVp and the amount of tube current was changed to 20, 30, 40, and 50 mAs, and the dose area product and image quality were compared and analyzed. As a result, the dose area product increased from $1066mGycm^2$ to $6160mGycm^2$ to 6 times as the condition increased, while the spatial resolution and low contrast resolution were higher than 20 mAs and 30 mAs, Spatial resolution and low contrast resolution were observed below the evaluation criteria. In addition, the SNR and CNR increased up to 30 mAs, slightly increased at 40 mAs, but not significantly different from the previous one, and decreased at 50 mAs. As a result, the exposure dose significantly increased due to overexposure of the test conditions and the image quality deteriorated in all areas of spatial resolution, low contrast resolution, SNR and CNR.

A Study On Low Radiation Measurement of Radiation Measuring Devices and Improvement of Reaction Speed according to the Rapid Change of Radiation Dose (방사선 측정장치의 저준위 방사선 측정과 방사선량의 급격한 변화에 따른 장치의 반응 속도개선에 관한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.544-551
    • /
    • 2014
  • This paper suggests an algorithm to measure low-level radiation by radiation measuring devices, and the other algorithm to improve reaction speed of the device to better respond to dramatic changes in radiation amount. The former algorithm to improve the accuracy of measuring low-level radiation takes advantage of a dual window radiation measurement method which is based on accumulated average of pulses gathered by a radiation measuring sensor. The latter algorithm is to enhance reaction speed of a measuring device to more sensitively react to dramatic changes in radiation amount by adopting a dual window radiation measurement method which analyzes data patterns newly put into for six seconds. To verify the suggested algorithms, a hardware-which consists of sensor and high-voltage generator, controller, charger and power supply circuit, wireless communication part, and display part-was used. Tests conducted on the dual window radiation measurement method as used in the suggested algorithm have proved that accuracy improves to measure low-level radiation of 5uSv/h, and linearity also gets better. Other tests were conducted to see whether the suggested algorithm enhances the reaction speed of a radiation measuring device so that the device responds better to dramatically changing radiation amount. The experimental results have shown meaningful changes in numbers after six seconds. Therefore, the conclusions are made that the algorithm enhances the reaction speed of the device.

Effect of Low Dose γ Radiation on the Dormancy Breaking and Growth of in vitro Microtubers of Potato (Solanum tuberosum L.) Stored at Low Temperature (저선량 방사선이 저온 저장한 감자 기내 소괴경의 휴면타파와 생육에 미치는 효과)

  • Kim, Jae-Sung;Kim, Dong-Hee;Back, Myung-Hwa;Jeon, Jae-Heung;Lee, Young-Bok
    • Horticultural Science & Technology
    • /
    • v.19 no.4
    • /
    • pp.515-520
    • /
    • 2001
  • To observe the stimulating effect of low dose ${\gamma}$ radiation on the dormancy breaking and growth, microtubers of two potato cultivars (Solanum tuberosum L. cv. Dejima and cv. Superior) were irradiated at the dose of 0.5-30 Gy. Though it varied with cultivars and storage duration, sprouting rate, plant growth and tuber yield were promoted by 2-8 Gy irradiation in microtuber of 'Dejima' stored at low temperature. On the other hand, in microtuber of 'Superior', sprouting rate was promoted by 2 and 4 Gy irradiation, and the growth and tuber yield by 4 Gy irradiation. These results suggest that low dose of ${\gamma}$ radiation could have stimulating effects on the dormancy breaking of microtuber and potato growth.

  • PDF

Survival and Complication Rate of Radiation Therapy in Stage I and II Carcinoma of Uterine Cervix (병기 I, II 자궁 경부암에서 방사선치료 후 생존율 및 합병증 분석)

  • Ma, Sun-Young;Cho, Heung-Lea;Sohn, Seung-Chang
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.349-357
    • /
    • 1995
  • Purpose : To analyze survival rate and late rectal and bladder complication for patients with stage I and II carcinoma of uterine cervix treated by radiation alone or combined with chemotherapy Materials and Methods : Between November 1984 and December 1993, 127 patients with stage I and II carcinoma of uterine cervix treated by radiation alone or combined therapy of radiation and chemotherapy. Retrospective analysis for survival rate was carried out on eligible 107 patients and review for complication was possible in 91 patients. The median follow-up was 47 months (range 3-118) and the median age of patiens was 56 years (range 31-76). 26 patients were stage IB by FIGO classification, 40 were stage IIA and 41 were stage IIB. 86 cases were treated by radiation alone and 21 were treated by radiation and chemotherapy. 101 patients were treated with intracavitary radiation therapy (ICRT), of these, 80 were received low dose rate (LDR) ICRT and 21 were received high dose rate (HDR) ICRT. Of the patients who received LDR ICRT, 63 were treated by 1 intracavitary insertion and 17 were underwent 2 insertions And we evaluated the external radiation dose and midline shield. Results : Actuarial survival rate at 5 years was $92{\%}$ for stage IB, $75{\%}$ for stage IIA, $53{\%}$ for stage IIB and $69{\%}$ in all patients Grade 1 rectal complications were developed in 20 cases ($22{\%}$), grade 2 were in 22 cases ($24{\%}$). 22 cases ($24{\%}$) of grade 1 urinary complications and 17 cases ($19{\%}$) of grade 2 urinary complications were observed But no patient had severe complications that needed surgical management or admission care. Maximum bladder dose for the group of patients with urinary complications was higher than that for the patients without urinary complications (7608 cGy v 6960cGy. p<0.01) Maximum rectal dose for the group of patients with rectal complications was higher than that for the patients without rectal complications (7041cGy v 6269cGy, p<0.01). While there was no significant difference for survival rate or bladder complication incidence as a function of dose to whole pelvis, Grade 2 rectal complication incidence was significantly lower for the patients receiving less than 4500cGy ($6.3{\%}$ v $25.5{\%}$, p<0.05). There was no significant differance between HDR ICRT group and LDR ICRT group for survival rate according to stage, on the other hand complication incidence was higher in the HDR group than LDR group, This was maybe due to different prescription doses between HDR group and LDR group. Midline shield neither improved survival rate nor decreased complication rate. The number of insertion in LDR ICRT group did not affect on survival and compication rate. Conclusion : In stage I and II carcinoma of uterine cervix there was no significant differance for 5 year survival rate by radiation therapy technique. Rectal complication incidence was as a function of dose to whole pelvis and there were positive correlations of maximum dose of rectum and bladder and each complication incidence. So we recommand whole pelvis dose less than 4500cGy and maximum dose of rectum and bladder as low as possible.

  • PDF

Study on the Method for Reducing the Operator's Exposure Dose From a C-Arm System (C-Arm 장비의 사용 시 시술자의 피폭선량 저 감화 방법 연구)

  • Kim, Ki-Sik;Song, Jong-Nam;Kim, Seung-Ok
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.493-499
    • /
    • 2016
  • In this study, C-Arm equipment is being used as we intend to verify the exposure dose on the operator by the scattering rays during the operation of the C-Arm equipment and to provide an effective method of reducing the exposure dose. Exposure dose is less than the Over Tube method utilizes the C-arm equipment Under Tube the scheme, The result showed that the exposure dose on the operator decreased with a thicker shield, and as the operator moved away from the center line. Moreover, as the research time prolongated, the exposure dose increased, and among the three affixed location of the dosimeter, the most exposure dose was measured at gonadal, then followed by chest and thyroid. However, in consideration of the relationship between the operator and the patient, the distance cannot be increased infinitely and the research time cannot be decreased infinitely in order to reduce the exposure dose. Therefore, by changing the thickness of the radiation shield, the exposure dose on the operator was able to be reduced. If you are using a C-Arm equipment discomfort during surgery because the grounds that the procedure is neglected and close to the dose of radiation shielding made can only increase. Because a separate control room cannot be used for the C-Arm equipment due to its characteristic, the exposure dose on the operator needs to be reduced by reinforcing the shield through an appropriate thickness of radiation shield devices, such as apron, etc. during a treatment.

Effects of Low Dose Gamma Radiation on the Growth and Antioxidant Enzyme Activities of Chinese Cabbage (Brassica campestris L.) Seedlings (배추 유식물의 생장과 항산화효소의 활성도에 미치는 저선량 방사선의 효과)

  • 김재성;이영근;백명화;김동희;이영복
    • Korean Journal of Environmental Biology
    • /
    • v.18 no.2
    • /
    • pp.247-253
    • /
    • 2000
  • In order to investigate the stimulatory effect(hormesis) of low dose gamma-radiation on the seeding growth of old seeds with respect to antioxidant defense systems, various doses of gamma radiation to the 5-year-old dried seeds of Chinese cabbage (Brassica campestris L. cv Sulin eockaei). Compared to the new, 1-year- old seeds, old seeds irradiated by low does gamma radiation in the range of 1-2 Gy showed vigor growth as revealed by statistically significant increases both in the germination rates and the leaf size and fresh weight. Further, seedlings grown from seeds treated by low dose gamma radiation showed higher peroxidase and catalase activities than non-treated seedlings. These results suggest that the antioxidant defense systems could be closely related to the stimulatory effects of low dose radiation. [antioxidant enzyme, chinese cabbage, gamma radiation, germination rate, hormesis]

  • PDF