• Title/Summary/Keyword: 저류계수

Search Result 164, Processing Time 0.022 seconds

Parameter Decision of Muskingum Channel Routing Method Based on the Linear System Assumption (선형시스템가정에 근거한 Muskingum 하도추적방법의 매개변수 결정)

  • Yoo, Chulsang;Sin, Jiye;Jun, Chang Hyun
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.5
    • /
    • pp.449-463
    • /
    • 2013
  • This study proposes the method for determining the Muskingum channel routing model parameters based on the assumption of linear system. The proposed method was applied to the Chungju dam basin for the evaluation. Additionally, the rainfall-runoff was repeated for the Yeongchun-Chungju dam reach using seven rainfall events observed. Summarizing the results is as follows. First, the concentration time and storage coefficient of a channel reach formed by the subdivision can be expressed as the difference between the concentration times and storage coefficients of upstream and downstream basins. The storage coefficients of the channel reach estimated is equal to the storage coefficient of the Muskingum channel routing model and the weight factor can be simply estimated using the ratio between the concentration time and storage coefficient. Second, the weight factor of the Muskingum model is in inverse proportion to the Russel coefficient, which is in between 0.4166 and 0.625 when considering the Russel coefficients generally applied. Finally the application to the Yeongchun-Chungju dam reach showed that the proposed method is still valid regardless of the limitations such as the uncertainty of the observed data.

Generalization of Modified TOPMODEL for Rainfall-Runoff Analysis of Sulmachun Watershed (수정 TOPMODEL에 의한 유출해석과 일반화 (설마천 유역을 중심으로))

  • Lee, Hak-Su;Kim, Nam-Won;Kim, Sang-Hyeon
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.3
    • /
    • pp.295-306
    • /
    • 2002
  • The modified TOPMODEL of two storage systems has been integrated to the generalized assumptions of decreasing hydraulic conductivity to vertical direction. Three different recharge functions were introduced to explore the impact of the macropore flow to vortical direction, the storage at the surface zone and the relative storage deficit of the soil matrix. Combinations of these approaches provide 30 type of the model structure for the hillslope hydrology. Developed models have been applied to several hydrologic events at the Sulmachun watershed. The performance evaluation with the Monte carlo simulation suggests that the exponential function of transmissivity reduction should be appropriate form for the physically -based hydrologic simulation on the Sulmachun watershed. It has been shown that the recharge function of macropore flow contributes to improve the predictability of the generalized version of modified TOPMODEL.

An Experimental Study on Filtration Efficiency of Sand Filter Layers to TSS and COD in Non-point Source Pollutant (분산형 빗물 저류조용 모래 여과층을 적용한 도심지 비점오염원의 TSS와 COD 정화효율에 대한 실험적 연구)

  • Ahn, Jaeyoon;Lee, Dongseop;Han, Shinin;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1477-1488
    • /
    • 2014
  • Prevalent construction of impermeable pavements in urban areas causes diverse water-related environmental issues, such as lowering ground water levels and shortage of water supply for the living. In order to resolve such problems, a rainwater reservoir can be an effective and useful solution. The rainwater reservoir facilitates the hydrologic cycle in urban areas by temporarily retaining precipitation-runoff within a shallow subsurface layer for later use in a dry season. However, in order to use the stored water of precipitation-runoff, non-point source pollutants mostly retained in initial rainfall should be removed before being stored in the reservoir. Therefore, the purification system to filter out the non-point source pollutants is essential for the rainwater reservoir. The conventional soil filtration technology is well known to be able to capture non-point source pollutants in a economical and efficient way. This study adopted a sand filter layer (SFL) as a non-point source pollutant removal system in the rainwater reservoir, and conducted a series of lab-scale chamber tests and field tests to evaluate the pollutant removal efficiency and applicability of SFL. During the laboratory chamber experiments, three types of SFL with the different grain size characteristics were compared in the chamber with a dimension of $20cm{\times}30cm{\times}60cm$. To evaluate performance of the reservoir systems, the concentration of the polluted water in terms of TSS (Total Suspended Solids) and COD (Chemical Oxygen Demand) were measured and compared. In addition, a reduction in hydraulic conductivity of SFL due to pollutant clogging was indirectly estimated. The optimum SFL selected through the laboratory chamber experiments was verified on the in-situ rainwater reservoir for field applicability.

Estimation of streamflow depletion due to groundwater pumping using analytical solution and empirical formula (해석해와 경험공식을 이용한 하천 인근 지하수 양수에 따른 하천수 감소율 분석)

  • Lee, Jeongwoo;Kim, Nam Won;Chung, Il-Moon;Hong, Sung Hun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.220-220
    • /
    • 2019
  • 천부대수층-심부대수층-하천-양수정 시스템에 대해 개발된 Ward & Lough 해석해와 국내 시험유역을 대상으로 개발된 양수량 대비 하천수 감소량 산정공식 (한강홍수통제소, 2018)을 광주천인근에 실제로 위치한 지하수 관정에 적용하여 지하수 취수로 인해 하천의 수량에 미치는 영향을 분석하였다. 분석 대상관정은 하천에서 약 67 m 떨어진 공업용수 공급을 위한 지하수개발 이용시설로서 착정심도 100 m, 착정구경 150 mm, 취수계획량 $200m^3$/일, 수중펌프 5 Hp 등의 시설제원을 가진다. 해석해 및 경험공식 적용을 위한 기본 입력자료로 투수량계수, 저류계수 등의 수리상수값은 해당 관정의 지하수개발 이용 영향조사서에서 발췌하였고, 측정되지 않은 일부 입력값은 문헌조사를 통해 적절한 값을 가정하여 사용하였다. 하천의 수량에 미치는 지하수 양수 영향을 예측한 결과 지하수 허가기간 5년동안 취수계획량의 약 80 %를 넘는 하천수 감소율이 발생하는 것으로 분석되었다. 연구 대상관정과 같이 하천에 매우 근접한 지역에서 지하수를 이용할 경우 하천수 취수에 준하는 영향을 보일 수 있기 때문에 수자원의 효율적인 이용을 위해서는 하천수와 하천 인근 지하수의 통합적 관리가 필요할 것이다.

  • PDF

Analysis on the Potentiality of Domestic Rainwater Harvesting in Metro Manila (마닐라 지역의 가정용 우수저류시설 잠재가용성 분석)

  • Felix, Micah Lourdes A.;Maniquiz, Marla C.;Seo, Sung-Ho;Kim, Lee-Hyung;Jeong, Sang-Man
    • Journal of Wetlands Research
    • /
    • v.13 no.3
    • /
    • pp.633-641
    • /
    • 2011
  • The Philippines is known for its abundant water resources such as the rainfall, where it has a mean annual rainfall range from 965 to 4,100mm. Due to the rapid urbanization of the country, the population in Metro Manila has been continuously increasing hence, the demand for a potable water supply also increases. To mitigate the scarcity of potable water supply, utilization of the water resources should be practiced. Rainwater harvesting is one way to utilize the rainfall runoff. This study analyzedthe potentiality of the rainwater harvesting on residential areas in Metro Manila. A water balance method based spreadsheet was used with input parameters including daily rainfall, catchment area, runoff coefficient, population and the water demand. The efficiency of the domestic water tank was analyzedusing the three different climatic conditions (i.e., minimum, median andmaximum annual rainfalls) and three different types of toilets (i.e., inefficient, conventional and dual-flush toilets). Furthermore, the overflow volume was used to determine which size of rainwater storage was more appropriate for the study area. The results of the study showed that for the three types of rainfall years, only the conventional and dual-flush toilets were suitable for the utilization of rainwater harvesting. The utilization of the $60m^3$ storage tank was sufficient for supplying the demandsof the 90 houses only for a small period of time, 3 months. Based from this study, to fully sustain the long-term water demand of the houses, the enlargement of the tank size having a capacity of 1,100 to $2,500m^3$ is ideal.

산지유역의 초과우량 추정 모형

  • 남선우;최은호
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1990.07a
    • /
    • pp.49-52
    • /
    • 1990
  • 강우강도가 큰 집중호우가 지표면에 도달하게 되면 강우량중 상당 부분이 수문학적 손실성분인 침수, 증발산, 차단 및 저류등으로 시간에 따라 분포된다. 이 가운데 지표면에 분포된 식생계 및 낙엽등에 의한 차단(canopy interception effect)과, 지표가 포화시의 증발산(wetted environmental evapotranspiration) 및 각종 저류, 즉 지표면 저류(depression storage), 지표토양층에의 저류(retention storage) 성분 등을 들 수 있으며 이들 각 손실성분은 직접유출로 나타나는 초과우량의 발생시간을 지체시켜 주는 역할을 하나 차단성분 및 저류성분은 시간이 경과함에 따라 결국은 증발산 또는 침투성분으로 흡수된다. 따라서 침투성분은 초과우량 추정에 매우 큰 영향을 줄 뿐 아니라 지표면 아래의 흙의 변형을 야기시키며, 중간유출 및 지하수유출에 기여 한다. 대부분의 호우사상은 강우초기에 강우강도가 지표 흙의 침수계수(hydraulic conductivity)보다 작기 때문에 모두 각 손실성분에 의해 손실되며, 강우강도가 점차 커져 침수능을 초과하면 지표면에 순간적으로 물이 고이게 되는데 이것을 지표심수(surface ponding)라하고, 강우시작부터 이 때까지가 침수시간(ponding time)이 된다. 이 지표침수가 나타나는 순간이 곧 직접유출 시작 시간으로 볼 수 있을 뿐 아니라, 침수시간은 지표면의 물수지면에서 볼 때 초기손실량 및 침수율 결정에 중요한 인자가 된다. 본 연구에서는 각 손실 성분별로 유역의 제반 특성을 고려하여 구한 매개변수로부터 시간에 대한 손실율을 결정하여 산지 하천유역에 발생하는 부정강우사상(unsteady rainfall)의 초과우량을 추정하는 모델을 유도하였다. 대상유역으로는 현재 건설부에서 수행하고 있는 국제수문개발계획(IHP) 대표시험유역 가운데 평창강 수계내의 장평유역으로서, 본 유역은 자기 우량계 및 자기 수위계가 운용되고 있고, 인접 대관령 측후소로부터 기상자료를 획득, 이용할 수 있는 비교적 분석에 양호한 조건을 지닌 유역이다. 모델의 유도 과정은 대상유역 식생계로 피복된 산지유역임으로, 식생차단 저류효과를 고려해서 지표면의 흙에 도달되는 순강우주상도를 얻고 이로부터 침수시간 및 침투율을 결정해서 초과우량을 산정하는 모델을 유도하였다. 강우 지속시간내 즉, 유역이 완전 포화시의 증발산율의 결정은 Morton 모델로부터, 침수시간 및 침투율 결정은 Green-Ampt 방정식을 부정강우사상에 적용할 수 있도록 수정된 모델을 사용하였으며, 분석에 이용된 호우는 1986 ~ 1987년도 발생된 호우사상 가운데 강우강도 및 총 강우량이 비교적 큰 7개 강우사상을 선정하였다. 각 호우사상별로 손실율울 지표면에서 물수지개념을 이용하여 계산하고 산술지상에 구성시킨 결과는 다음 그림과 같다. 이 그림에서 굵은 실선으로 나타낸 곡선(B. L. R)은 각 손실을 곡선을 시간축에 따라 산술평균한 대표손실율곡선이다. 이 대표손실율곡선은 역지수함수형으로서 곡선식의 유도는 회기분석을 이용하였다. 초과우량 주상도를 얻기 위하여 이 대표손실을 곡선을 관측 강우주상도에 적용시켜 본 결과 식생계에 의한 차단 저류율은 약 6mm/hr 정도인 것으로 나타났으며, 이로 인한 침수시간 지체효과는 1~3시간 정도로서 비교적 그 영향이 큼을 알았다. 또한 각 호우사상별 침수시간 계산 결과 그 변동이 큰 것으로 나타났는데 이는 초기 강우강도에 민감하기 때문인 것으로 판단되낟. 한편 유역 포화시의 증발산율은 우기의 기상자료를 이용하여 구한 결과 0.05 - 0.10 mm/hr 의 범위로서 이로 인한 강우손실량은 큰 의미가 없음을 알았다.

  • PDF

부산 동남부 지역의 해수침입 범위 연구

  • 심병완;정상용;이민희
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.143-147
    • /
    • 2002
  • 본 연구의 목적은 부산 동남부 해안지역의 대수층에서 염수화에 미치는 조건들을 파악하고 해수침투 범위를 추정하는데 있다. 이를 위하여 Tidal damping method와 SUTRA 모델링을 실시하고 대수층의 특성 및 염수화가능성을 파악하였으며, 모델링 결과의 타당성을 판단하기 위하여 전기비저항 탐사를 실시하였다. Tidal damping method에 의한 시간지연과 조석효율효과를 계산하여 대수층의 저류계수를 산출한 결과 시간지연 현상에 의한 방법이 적합하게 나타났다. SUTRA 모델링 결과, 건기인 5월에는 종분산 지수가 2.5m 일 때 500ppm의 TDS 등치선을 기준으로 해안에서 약 510m 내륙까지 해수의 영향을 받고 있는 것으로 나타났다. 그러나 우기인 7월에는 강수로부터 다량의 지하수 함양에 의한 지하수위 상승을 고려하여, 평균수리경사를 0.008로 설정한 조건에서는 500ppm의 TDS 등치선을 기준으로 해안에서 약 410m 내륙까지 해수의 영향을 받는 것으로 나타난다. 5월과 7월의 전기비저항 탐사결과를 비교하면 7월의 전기비저항 분포가 전반적으로 높게 나타났다. 그 이유는 6, 7월의 강수에 의한 지하수의 유입이 증가하여 침투된 염수의 농도가 다소 낮아졌기 때문이다.

  • PDF

Performance evaluation for flood water level control of a series of floating type movable weir (다단배치된 부력식 자동수문의 홍수위조절 성능평가)

  • Han, Il-Yeong;Choe, Heung-Sik;Lee, Ji-Haeng;Na, Seong-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.58-62
    • /
    • 2017
  • 우리나라는 하상계수가 큰 하천의 특성 때문에 년 중 일정한 하천수위를 유지하기 어렵다. 더욱이 지류하천의 중 상류는 갈수기에는 건천화가 발생하곤 하며, 홍수기에는 빠른 유속으로 하류의 홍수위를 상승시키곤 한다. 따라서 지류하천 중 상류에는 수위조절 기능을 가지는 가동보를 설치하여 저류와 분배기능을 부여하고, 수재해 예방에 활용할 필요가 있다. 본 연구에서는 부력 승강식 가동보에 의한 수위자동조절 효과를 금강 지류인 치성천의 중 상류를 대상으로 수문학적 홍수추적 방법을 이용하여 분석하고, 성능구현을 위한 조건들을 검토하였다. 부력 승강식 가동보는 저류와 자동방류 기능으로 홍수기에는 하류의 홍수위 완화에 효과적이었으며, 다단으로 연속 배치할수록 효과는 향상되는 것으로 분석되었다.

  • PDF

Performance Evaluation of Eco-Friendly Prefabricated Rainwater Permeable Detention Block Structure (친환경 조립식 빗물침투저류블록 구조체의 성능검토)

  • Jung, YoungWoong;Ju, SeungJin;Kim, Hojin;Lee, Taegyu;Choi, Heeyong;Ryu, Jungrim;Choi, Hyeonggil
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.299-300
    • /
    • 2023
  • In this study, the performance evaluation and structural safety of rainwater permeation detention block were analyzed. As a result, the compressive strength (19.3 MPa), flexural strength (5.2 MPa), and permeability coefficient (2.0 mm/s) of the eco-friendly prefabricated rainwater permeable detention block satisfied the KS F 4419 and SPS-KCIC0001-0703 and it was confirmed sufficient safety even under maximum load.

  • PDF

Catchment Similarity Assessment Based on Catchment Characteristics of GIS in Geum River Catchments, Korea (금강 유역을 대상으로 한 GIS 기반의 유역의 유사성 평가)

  • Lee, Hyo Sang;Park, Ki Soon;Jung, Sung Heuk;Choi, Seuk Keun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.21 no.3
    • /
    • pp.37-46
    • /
    • 2013
  • Similarity measure of catchments is essential for regionalization studies, which provide in depth analysis in hydrological response and flood estimations at ungauged catchments. However, this similarity measure is often biased to the selected catchments and is not clearly explained in hydrological sense. This study applied a type of hydrological similarity distance measure-Flood Estimation Handbook to 25 Geum River catchments, Korea. Three Catchment Characteristics, Area(A)-Annual precipitation(SAAR)-SCS Curve Number(CN), are used in Euclidian distance measures. Furthermore, six index of Flow Duration Curve are applied to clustering analysis of SPSS. The catchments' grouping of hydrological similarity measures suggests three groups (H1, H2 and H3) and the four catchments are not grouped in this study. The clustering analysis of FDC provides four Groups; F1, F2, F3 and F4. The six catchments (out of seven) of H1 are grouped in F1, while Sangyeogyo is grouped in F2. The four catchments (out of six) of H2 are also grouped in F2, while Cheongju and Guryong are grouped in F1. The catchments of H3 are categorized in F1. The authors examine the results (H1, H2 and H3) of similarity measure based on catchment physical descriptors with results (F1 and F2) of clustering based on catchment hydrological response. The results of hydrological similarity measures are supported by clustering analysis of FDC. This study shows a potential of hydrological catchment similarity measures in Korea.