• Title/Summary/Keyword: 재질감쇠

Search Result 46, Processing Time 0.026 seconds

A Study on Dynamic Characteristics of Hydraulic Transmission Line by Finite Difference Method (有限差分法을 利용한 油壓管路의 特性에 관한 硏究)

  • 오철환;정선국;송창섭
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.1
    • /
    • pp.15-24
    • /
    • 1986
  • Pressure trasients must deal with safety problem of system. For identification of physical situation that can and method of limiting surges are essential consideration in sucessful design. The finite difference equation by method of characteristics are derived from the governing equation of unsteady flow in a pipe, and solved by using boundary condition derived. A computer program which can simulate general hydraulic system is developed by using finite difference equations and boundary conditions derived. The sumulated resulted by developed computer program are in fair agreement with experiment result.

The Estimation of Neutron Fluence in Nuclear Reactor Vessel Materials by the Analysis of Ultrasonic Characteristics (초음파특성 분석에 의한 원자로 재료의 중성자 조사량 예측)

  • Lee, Sam-Lai;Chang, Kee-Ok;Kim, Byoung-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.3
    • /
    • pp.307-312
    • /
    • 2001
  • Ultrasonic signals from Charpy impact test specimen have been analyzed in order to evaluate the integrity of reactor pressure vessel. Base and weld metal that were extracted from reactor vessel doting plant outages according to the schedule of the surveillance test required by the related regulations have been used and the ultrasonic test parameters including velocity, attenuation, etc. showed a close correlations with the amount of neutron irradiation for base metal, relatively homogeneous materials. This result showed certain possibility where a nondestructive method could be used to predict the fluence of the Irradiation due to neutron in nuclear reactor vessel materials.

  • PDF

Experimental Study on the Nondestructive Evaluation of Udimet 720Li Disc (Udimet 720Li 디스크의 비파괴 평가에 관한 실험적 연구)

  • Won, Sun-Ho;Jo, Gyeong-Sik
    • 연구논문집
    • /
    • s.28
    • /
    • pp.229-238
    • /
    • 1998
  • Materials and parts required for nondestructive testing should be evaluated using with standard block. And it is ruled that standard blocks should be fabricated from same or similar material with test specimen. In order to manufacture and export materials and parts, quality assurance system should be required. In this paper, ultrasonic characteristics of ASTM 4340 steel ultrasonic standard block are investigated for nondestructive evaluation of udimet 720Li disc. Microstructures of udimet 720Li alloy are investigated using with optical and transmission electron microscope. Also ultrasonic transit time and attenuation are measured from high power ultrasonic analysis system with phase adjustment method. Conclusively, it is proved that 4340 steel ultrasonic standard block can be use for nondestructive evaluation of udimet 720Li disc.

  • PDF

Finite Element Eigen Analysis of Undamped Beam Structure with Composite Sections (복합단면을 갖는 비 감쇠 보 구조물의 유한요소 고유치 해석)

  • Park, Keun-Man;Cho, Jin-Rae;Jung, Weui-Bong;Bae, Soo-Ryong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.691-697
    • /
    • 2007
  • Numerical eigen analysis of beam-like structure can be easily and effectively done by various conventional beam theory-based methods. However, in case of the structures composed of composite-sectioned beams, the application of conventional numerical methods requires one to derive both equivalent material and geometry properties. In the present paper, these equivalent properties are derived by the transformed section method and the test FEM program is coded. The numerical accuracy of the proposed method is verified through the comparison with the ANSYS 3-D model.

Vertical Vibration Isolator for Reducing Structural Vibration (구조물의 진동저감을 위한 수직형 면진장치)

  • Choi, Sanghyun;Baek, Joon-Ho;Lee, You In
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.2
    • /
    • pp.197-203
    • /
    • 2012
  • In these days, the design of a structure for reducing or eliminating noise and vibration is getting more important, as the social demands for reducing environmental pollution rise. In this paper, the basic concept and performance verification test results of the recently developed vertical vibration isolator are presented. The isolator attenuates vibration using the damping action from the friction plane made of PTFE and provides the restoring force from the polyurethane springs arranged in vertical and horizontal directions. The performance verification tests consist of a test for identifying performance change during load rate variation and a test for confirming the force-displacement relationship assumption in vibration force range.

The Structural Design and Analysis of Spring Stabilizer for Aircraft Surveillance and Reconnaissance EO/IR Equipment (감시정찰 전자광학장비용 스프링 안정화 장치 구조 설계 및 해석 연구)

  • Yoonju Jung;Suhyeon Kim;Sanghyun Nam;Injae Park;Mingyun Park;Taekyun Kim;Hwanseok Yang;Seungwook Park;Seungha Lee
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.5
    • /
    • pp.28-33
    • /
    • 2023
  • In this research, the isolator and the inner gimbal inside of typical EO/IR equipment were replaced with a spring stabilizer. This Spring stabilizer system revealed an internal platform capable of external vibration damping and 6-DOF driving. This system was designed based on machined springs and spring modules of the spring stabilizer, structure, and other fixture. Through modal vibration analysis, suitable material for the spring was determined. Structural stability of the spring stabilization device was determined through random vibration analysis.

A study on the standard for determining airborne sound insulation performance of sound barrier panels (방음판의 음향투과손실 측정규격에 관한 연구)

  • Oh, Yang Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.3
    • /
    • pp.302-311
    • /
    • 2022
  • Sound barrier walls are one of the most effective alternatives for reducing environmental noise on roads and railways in the city center. The insertion loss of the sound barrier against road traffic noise is the sum of the sound transmission loss, sound absorption loss, and sound energy reduction due to the diffraction attenuation of the sound barrier. The sound transmission loss of the sound barrier is one of the important factors that determine the insertion loss of the sound barrier and is a basic indicator that determines the performance of the sound barrier. Nevertheless, there is not a separate standard in Korea for measuring the acoustic transmission loss of sound barrier panels. There are only a few conditions in KS F 4770 series that stipulates on the general material of sound barrier panels. This thesis examines the necessity of the acoustic transmission loss measurement and evaluation standards of sound barrier walls, and seeks a measurement method in a free sound field (anechoic chamber) sound receiving room considering the characteristics of sound barrier walls installed in external spaces, unlike indoor building materials. In addition, a single number evaluation method using a reference spectrum was proposed so that the sound insulation effect according to various installation places such as roadside or railroad side can be easily displayed.

Dose modeling and its Application of Ir-192 for substitution of Ralstron Brachytherapy source (Ralstron 선원대체형 Iridium-192 선원의 선량모델링과 응용)

  • 김옥배;최태진;김진희;이호준;박정호;김성규;조운갑;한현수
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.131-139
    • /
    • 2000
  • We designed high dose rate Ir-192 source which was prepared for substitute the Co-60 source in Ralstron unit (Simatsu, Japan) which is supplied for cervical cancer treatment. The source dimension is 1.5 mm in a diameter and 1.5mm thickness of cylinder and encapsulated with 3 mm diameter of stainless steel(SUS316L) to substituted for the Co-60 source size. The Ir-192 source was prepared the dose model for tissue dose computation through the experimental determination of apparent activity and applied the empirical tissue correction factors extended to 20cm distance. The tissue dose model was applied the 4.69 R/cm-mCi-hr gamma constant and the ratio of energy absorption coefficient of water to that of air showed 1.112 include filteration of the self-absorptions. In this experiments, we prepared the dose computation software to clinical usefulness.

  • PDF

Development of a Duplexer Module for Remote Wireless Communication System of Guided Weapon System with Temperature-Insensitive Electrical Performances (온도변화에 둔감한 전기적 특성을 가지는 유도무기체계 원격무선통신시스템용 듀플렉서 모듈 개발)

  • Choi, Byung-Chang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.8
    • /
    • pp.709-716
    • /
    • 2016
  • In this paper, A duplexer module with temperature-insensitive electrical characteristics was proposed for remote wireless communication system. Duplexer modules are required to have performances of low insertion loss, high isolation between transmitted band and received band, harmonic suppression as well as high power durability in the system for transmitting guided information to missile flying a free space on the ground. The proposed duplexer module are consist of transmission bandpass filter and receiving bandpass filter which are connected to common antenna port, planar coupler for output power monitoring and low pass filter for harmonic attenuation of power amplifier and coaxial cavity resonator. The material and dimensions of the resonator are determined for minimum frequency shift by temperature variation using 3D EM simulation. The measured results of the prototype showed a good agreement with the simulation results, and it should be well applied not only for guided weapon systems but also for any other communication systems such as remote radio head.

A Study of Radiation Exposure in Proton Therapy Facility (양성자치료기 가속기 시설에서의 작업종사자의 방사선 피폭 연구)

  • Lee, Sang-Hoon;Shin, Dong-Ho;Yoon, Myong-Geun;Shin, Jung-Wook;Rah, Jeong-Eun;Kwak, Jung-Won;Park, Sung-Yong;Shin, Kyung-Hwan;Lee, Doo-Hyun;Ahn, Sung-Hwan;Kim, Dae-Yong;Cho, Kwan-Ho;Lee, Se-Byeong
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.37-42
    • /
    • 2009
  • Proton therapy facility, which is recently installed at National Cancer Center in Korea, generally produces a large amount of radiation near cyclotron due to the secondary particles and radioisotopes caused by collision between proton and nearby materials during the acceleration. Although the level of radiation by radioisotope decreases in length of time, radiation exposure problem still exists since workers are easily exposed by a low level of radiation for a long time due to their job assignment for maintenance or repair of the proton facility. In this paper, the working environment near cyclotron, where the highest radiation exposure is expected, was studied by measuring the degree of radiation and its duration for an appropriate level of protective action guide. To do this, we measured the radiation change in the graphite based energy degrader, the efficiency of transmitted beam and relative activation degree of the transmission beam line. The results showed that while the level of radiation exposure around cyclotron and beam line during the operation is much higher than the other radiation therapy facilities, the radiation exposure rate per year is under the limit recommended by the law showing 1~3 mSv/year.

  • PDF