• Title/Summary/Keyword: 재이용수

Search Result 36, Processing Time 0.016 seconds

Determinant Factor Analysis for the Spread of Water Reuse (물재이용 활성화를 위한 결정요인분석)

  • Park, Hyunju;Kim, Tschungil;Han, Mooyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.271-276
    • /
    • 2014
  • The purpose of this study was to survey Suwon citizens over the age of 20 in order to provide basic data on the extent of coverage of the city's water reclamation system and to set guidelines for a policy on water reuse. The survey used a questionnaire with two fields, rainwater use and wastewater recycling, for analyzing factors that influenced water reuse. A factor analysis of 19 questionnaires gave a Cronbach's alpha coefficient greater than 0.4. Factors that influenced rainwater use were environmental protection, water charges, and the risk of climate change. Of the total explanatory power, the share of rainwater use and environmental protection was 39.7% and 28.1% respectively. Environmental protection (explanatory power 24.2%) had an effect on the explanatory power of wastewater reuse. When factors influencing wastewater recycling, like cost of recycling, water management policy, climate change, and suspension of tap water supply were included, the explanatory power of each of these factors went up by 4.3%, 2.8%, 3.3%, and 1.1%, respectively. For more effective wastewater recycling, a water management policy that factors in the above is required, along with a campaign to educate citizens on water management and environment conservation. Additionally, it may be necessary to improve the reliability and the quality of water supply.

Effect of Trans-Membrane Pressure on Reversible and Irreversible Fouling Formation of Ceramic Membrane (막간차압이 세라믹막의 가역막오염과 비가역막오염 형성에 미치는 영향)

  • Lee, Heewon;An, Kwangho;Choi, Juneseok;Kim, Seogku;Oh, Hyunje
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.9
    • /
    • pp.637-643
    • /
    • 2012
  • This study was carried out to investigate how reversible and irreversible fouling were distributed in the filtration using ceramic membrane of 300 kDa pore size for secondary effluent of wastewater. It was performed by calculating fouling as numerical method for diverse TMPs and measured F-EEM and SEC for raw water, treated water and backwashed water. Water quality was also checked to know whether treated water quality was stable or not. The results showed that reversible fouling formation was increased when lower TMP was applied and it is caused by protein like organic matters having higher molecular weights. The secondary wastewater effluent had diverse molecular weight materials, especially contaminants lower than 0.5 kDa and bigger than 12 kDa. Decreasing TMP induced contaminants above 12 kDa and below 1 kDa to become reversible fouling.

A Study of Antibiotic Resistance of Enterococci Isolated from Recycling Water of Floor Fountains in Gwangju Area (광주지역내 바닥분수 재이용수에서 분리한 장구균의 항생제 내성 연구)

  • Kim, Yeon-Hee;Song, Hyeong-myeong;Choi, Yeong-Seop;Lee, Yoon-Kook;Park, Jin-Hwan;Kim, Sun-Jung;Kim, Ha-Ram;Kang, Yu-Mi;Bae, Seok-Jin;Cho, Yong-Gwan
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.3
    • /
    • pp.222-230
    • /
    • 2019
  • Objectives: This study aims to evaluate water quality in terms of microorganisms and identify the antibiotic resistance of Enterococci isolated from the recycling water in floor fountains at three parks and one reservoir in the Gwangju area. Methods: Water samples were analyzed for Enterococci using membrane Enterococcus indoxyl ${\beta}$ d glucoside agar (mEI) as described in USEPA Method 1600. The vancomycin-resistant Enterococci with VanA and VanB were identified by PCR. An examination of the antibiotic resistance of isolates against 14 antibiotics was performed by the disk diffusion method. Results: The drinking water quality criterion was exceeded for total colony counts in 68% of all recycling water samples. The average concentration of total califorms and fecal coliforms was 139,325 and 413 CFU/100 mL, respectively. VanA and VanB were not detected from the isolates. We found the antibiotic resistant Enterococci strains to be E. faecalis, E. faecium, E. durans, E. mundtii, E. hirae, and E. thailandicus. The isolates were resistant to Rifampin (50%), Erythromycin (25.8%), Tetracycline (10.2%), Nitrofurantoin (8.1%), Minocycline (3.1%), Erythromycin (1.2%), Penicillin (0.7%), Norfloxacin (0.5%), and Teicoplanin (0.5%) among the 14 antibiotics tested. Antibiotic resistance tests for Enterococci from the recycling water of floor fountains resulted in 30.2% showing resistance to two or more antibiotics. Conclusions: These results showed that the multi-antibiotic resistance of Enterococci, E. coli, and others should be investigated continuously in each environment field.

Hydrologic and Environmental Assessment of an Infiltration Planter for Roof Runoff Use (지붕 빗물이용을 위하여 개발된 침투화분의 환경·수문학적 평가)

  • Moon, So-Yeon;Choi, Ji-Yeon;Hong, Jung-Sun;Yu, Gi-Gyung;Jeon, Je-Chan;Flores, Precious Eureka D.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.17 no.4
    • /
    • pp.325-331
    • /
    • 2015
  • Due to urbanization and increase in impervious area, changes in natural water circulation system have become a cause of groundwater recharge reduction, streamflow depletion and other hydrological problems. Therefore, this study developed the infiltration planter techniques applied in an LID facility treating roof stormwater runoff such as, performance of small decentralized retention and infiltration through the reproduction of natural water circulation system and use of landscape for cleaning water. Assessment of an infiltration planter was performed through rainfall monitoring to analyze the water balance and pollutant removal efficiency. Hydrologic assessment of an infiltration planter, showed a delay in time of effluent for roof runoff for about 3 hours and on average, 79% of facilities had a runoff reduction through retention and infiltration. Based on the analysis, pollutant removal efficiency generated in the catchment area showed an average of 97% for the particulate matter, 94% for the organic matter and 86-96% and 92-93% for the nutrients and heavy metals were treated, respectively. Comparative results with other LID facilities were made. For this study, facilities compared the SA/CA to high pollutant removal efficiency for the determination to of the effectiveness of the facility when applied in an urban area.

Microbial Risk Assessment in Treated Wastewater Irrigation on Paddy Rice Plot (하수처리수를 관개한 후 벼재배 시험구에 대한 미생물 위해성 평가)

  • Jung, Kwang-Wook;An, Youn-Joo;Jang, Jae-Ho;Jeon, Ji-Hong;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.2 s.112
    • /
    • pp.225-236
    • /
    • 2005
  • The protection of public health In wastewater reclamation and reuse is one of the most important issues. Monitoring data of Escherichia coli were collected from paddy rice plots in 2003 and 2004 experiments. Five treatments were used and each one was triplicated to evaluate the changes of E. coli: surface water, biofilter effluent (secondary level), UV-disinfected water and pond treatment. Microbial risk was quantified to assess human health risk by exposure to E. coli in paddy rice plots, which were irrigated with reclaimed wastewater. Beta-Poisson model was used to estimate the microbial risk of pathogen ingestion that may occur to farmer and neighbor children. Monte-Carlo analysis (10,000 trials) was used to estimate the risk characterization of uncertainty. In the following analysis, two scenarios were related to the reduction of risk against direct ingestion and exposure times. Scenarios A and B were assumed that the risk was 1,000 and 10,000 times lower than direct ingestion.'Golfers were assumed to be 0.001 L of reclaimed water by contact with balls and their cloths. Opportunity of contact in paddy rice field with pathogens was more frequent than handing golf balls, because of agricultural activity was practiced in ponded water in paddy rice culture. As a result of microbial risk assessment using total data of experimental period, risk value of E. coli in 2003 and 2004 experiment ranged from $10^{-5}$ to $10^{-8}$ and $10^{-4}$ to $10^{-8}$, respectively. The risk values in biofilter effluent irrigation was the highest, which is $10^{-4}$ in 2003 and $10^{-5}$ in 2004 experiments with scenario A. Ranges of $10^{-6}$ to $10^{-8}$ were considered at reasonable levels of risk for communicable disease transmission from environmental exposure and the risk value above $10^{-4}$ was considered to be attributable to the risk of infection. Irrigation with UV-disinfected water in the paddy field during the agricultural Period showed significantly lower microbial risk than others, and their levels of risk value were within the range of actual paddy rice field with surface water.

A Study on Reuse of Reclaimed Water in Jeonbuk Province (전북지역 하수처리수 재이용 방안 연구)

  • Cho, Changwoo;Kim, Jintae;Park, Jeongjae;Song, Juhoon;Lee, Miseon;Jeong, Juri;Ryou, Jaewoong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.237-245
    • /
    • 2017
  • This study was aimed at investigating effluent water quality and proposing reuse possibilities for 12 sewage treatment plants discharged more than $5,000m^3/day$ in order to recycle the sewage treatment plant effluent of Jeollabuk-do effectively. Additionally, a laboratory scale test for reprocessing water discharge was performed. Categories of reclaimed sewage water reuse were divided into 7 topics and analyzed a total of 28 items including 16 heavy metals based on water quality standard. As a results, color, BOD, TN, chloride and Electrical Conductivity (EC) exceeded reused water quality standard. In particular, color and TN exceeded in 8 and 5 sewage treatment plants, respectively. The value of chloride and EC were high in sewage treatment plants including the food and industrial wastewater. At 4 sewage treatment plants were possible to reuse without re-treatment. The laboratory scale test was conducted to SandFilter (SF)-Granular Activated Carbon (GAC)-MicroFiltraion (MF)-Reverse Osmosis (RO). Both the removal efficiencies and economic feasibility of total E. coli., color and Suspended Solid (SS) suited in case using the SF-GAC treatment method. The removal of chloride and EC had little effect in the case of SF-GAC-MF system, but RO showed over 90% of removal efficiency. After using SF-GAC process only, the concentration of $UV_{254}$ decreased sharply from 0.3651 /cm to 0.0306 /cm and it showed over 92% of removal efficiency rate. In conclusion, for the effective reuse of sewage discharged water, water quality and the surrounding terrain of treatment plants should be all taken into account. If it needed for the reprocessing, both the selection for treatment and economic combination treatment methods will have to be considered.