• Title/Summary/Keyword: 재부착 길이

Search Result 93, Processing Time 0.023 seconds

A Study on the Behavior of Reinforced Clay Subjected to Direct Shear (직접전단을 받는 보강점토의 거동에 관한 연구)

  • 유한규
    • Geotechnical Engineering
    • /
    • v.10 no.4
    • /
    • pp.67-82
    • /
    • 1994
  • In this study, a reinforced clay model based on the limit equilibrium of forces under direct shear was proposed to predict shear strength increase in clays induced by the steel inclusion. The model accounted for the effects of orientation of inclusion, length, bonding stress between clay and indclusion and passive soil resistance 1 induced by the inclusion movement, on the behavior of reinforced clays. In order to compare with the theoretical predictions, direct shear tests were performed using a direct shear apparatus formed of an open shear box. Also pull-out tests were conducted to determine the bonding stress between the inclusion and clay. From the experimental results, the increase or decrease in shear strength of reinforced clay samples was found to depend on the orientation of inclusionas well as water content of clay samples. From the comparison of theoretical predictions and experimental results, it was found that the theore tical model predicted reasonably well the influence of orientation of the inclusion as well as passive soil resistance induced by the inclusion movement on the mechanical behavior of reinforced clays.

  • PDF

An Experimental Study on the Bond Strengths for Concrete Filled Steel Tube Columns using a Push-Out Test (단순가력실험을 통한 콘크리트충전 강관기둥의 부착응력에 관한 연구)

  • Woo, Hae Sung;Kim, Jin Ho;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.4
    • /
    • pp.481-487
    • /
    • 2002
  • Currently, the load transfer's mechanism from a beam to a column has yet to ve clarified in a concrete filled steel tubular (CFT) structure with a connection type of an exterior diaphragm. The loads for each floor are transferred to the concrete core from a steel beam through ha contacted face between an in-filled concrete and the interior surface of a steel tube. Thus, a Push-Out test was performed to investigate the load transfer mechanism. A total of 30 samples were tested to confirm the bond stress and/or axial load distribution between a steel tube and in-filled concrete for CFT column. The main parameters considered for this study included concrete type, steel tube-shape/length, and the effect of a weld joint wit ha backing strip for a column splice. Test results were summarized to confirm load transfer behavior between a concrete and steel tube for each experimental parameter, using the analytical approach to verify experimental results.

Dynamic Behavior of Pretensioned Concrete Member during Detensioning (긴장재 절단에 따른 프리텐션 부재의 동적 거동 고찰)

  • Kim, Jangho;Mun, Do Young;Ji, Goangseup;Kim, Gyuseon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.747-756
    • /
    • 2008
  • The purpose of this paper is to investigate the effect of the important parameters on the transfer length during the dynamic flame cutting of tendon experimentally. The considered parameters were strand diameter, concrete cover thickness, stirrup, debonding strand and release method. Ten pretensioned concete beam specimens were cast and tested. Time history curves for the axial strain of tendon were measured by electrical resistance strain gauges mounted on the strands. Experimental results indicated that large dynamic shock effects occurred near cut-end during the sudden release. The prestressing forces are dependent on the parameters above considered. The ratio of residual prestressing forces of 12.7 mm strands is greater than 15.2 mm strands. Using debonding strand and gradual release are more efficient for applying prestressing forces.

원지점 차넣기 모타 적용 잠입노즐 기초 기술 개발

  • 노태호;황종선;조인현
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.32-32
    • /
    • 2000
  • 잠입노즐은 로케트 추진기관의 길이 및 중량을 감소시켜 체계설계의 관점에서 볼 때 많은 이점을 제공한다. 본 연구에서는 3단형 과학로케트 원지점 차넣기 모타(apogee kick motor)에 적용하기위한 잠입노즐의 기초기술 개발에 주안점을 두었다. 고고도에서 저속으로 회전하며 비행하는 원지점 차넣기 모타를 제작하기위해서 체계 요구성능에 의해 예상된 실물형의 50% 크기에 해당하는 축소형 잠입노즐을 제작하였다. 잠입노즐은 잠입부의 내외부가 고온의 추진제 연소가스에 노출된 상태에서 노즐 내부 압력 외에 연소실압에 의한 외부압력이 작용하므로 이를 고려한 열 및 구조설계가 중요하다. 본 연구에서는 노즐 수렴부와 목부에 일체형 그라파이트 소재를 적용하고 확장부 내열재 및 잠입부 배면내열재에 탄소/페놀 복합재를 노즐 내열재로 사용하였다. 그리고 이들의 구조적 지지를 위해 스틸구조물을 적용하였다. 적용된 스틸구조물에는 K형 열전쌍을 이용해 내열재와 구조물 온도를 측정할 수 있는 관통구멍 및 나사부를 구조물 외변에 가공하였다. 열전쌍은 노즐 목직경의 2, 4배 되는 확장부 내열재 단면위치의 2mm와 4mm 깊이와 구조물 내면 및 외면의 4개소에 열전쌍을 부착하여 지상연소시험시 노즐 내열재와 구조물의 온도분포를 관찰한다. 그리고 노즐 조립시 확장부 내열재와 구조물에 각 각 반원형 홈을 내어 여분의 접착제가 원형 홈에 밀려들어가 경화되어 노즐 기밀유지와 체결력을 향상시킬 수 있는 원형공간 접착제 충전 공법을 적용하여 실제모타에 대한 적용가능성을 지상연소시험을 통해 확인한다.

  • PDF

An Experimental Study on the Performance of Bond-Type Anchorage Systems with Various Dimensions of Steel Mold (CFRP 긴장재용 부착형 정착 장치의 강관 몰드 제원에 따른 정착 성능 실험 연구)

  • Jung, Woo-Tai;Park, Young-Hwan;Park, Jong-Sup
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.257-264
    • /
    • 2011
  • This paper contains the experimental performance evaluation results of bond-type anchorage systems with the CFRP(carbon fiber reinforced polymer) tendon. The preliminary tests were performed to find the appropriate filling materials in the steel molds. A total of five materials including epoxy or cement mortar have been used as fillers in the steel molds. Results of the preliminary tests showed that specimen filled with non-shrinkage mortar showed maximum tensile strength. Based on the finding, the non-shrinkage mortar was selected as filler for anchoring CFRP tendons. Additional tests were performed as a parametric study to select proper size of steel molds such as external diameter, thickness, and length. The proper size of steel molds with non-shrinkage mortar was selected based on the test results, which gave stable tensile performance.

Effect of the separating streamline curvature on the axisymmetric backward-facing step flow (박리 유선의 곡률 변화가 축대칭 후향계단 흐름에 미치는 영향)

  • Kim, K.C.;Boo, J.S.;Yang, J.P.;Jung, J.Y.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.4
    • /
    • pp.1510-1520
    • /
    • 1996
  • An experimental study on the flow over the axisymmetric backward-facing step was carried out. The purpose of the present study is to investigate the effect of the separating streamline curvature on the reattachment length and to understand the structure of recirculating flows. Local mean and fluctuating velocity components were measured in the separating and reattaching axisymmetric region of turbulent boundary layer on the wall of convex cylinder placed in a water tunnel by using 2-color 4-beam fiber optics laser Doppler velocimetry. The study demonstrates that the reattachment length increases with increasing separating streamline curvature. It is also observed that the reverse flow velocity and turbulent kinetic energy increase with an increase in the separating streamline curvature. In addition, the behavior of maximum turbulent stresses show that the effect of separating streamline curvature is larger in the region of recirculating zone(X/H<2) than in the region of reattachment point.

Bond Behavior of Concrete According to Replacement Ratio of Fly Ash and Compressive Strength of Concrete (플라이애시 치환율 및 압축강도에 따른 콘크리트의 부착 거동)

  • Lee, Hyung-Jib;Suh, Jeong-In;Yoo, Sung-Won
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.1
    • /
    • pp.19-24
    • /
    • 2016
  • Several researches on high volume fly ash concrete have been conducted to investigate its fundamental material properties such as slump, strength and durability and however, research on the structural behavior of bond strength is essential for the application of this high volume fly ash concrete to structural members because of the necessity of reinforcement. But the exact design code for application and researches on the bond behavior of high volume fly ash concrete lack yet. To achieve such a goal, this paper evaluates experimentally the bond behavior of high volume fly ash concretes by direct pull-out test and compares between the current test results and existing research results. By the test results, it is shown that the bond behavior of high volume fly ash concrete is similar to that of general concrete. And by the comparison between test and existing research, it is shown that bond stress of high volume fly ash concrete is underestimated, as the embedment length gets longer.

Strength Characteristics in 3D-printed Concrete with Interlayer Reinforcements (층간 보강재로 보강한 3D 프린팅 콘크리트의 강도 특성)

  • Lee, Jung Woo;Park, Ji-Hun;Bui, The Quang;Jo, Changbin;Yang, In-Hwan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.3
    • /
    • pp.338-347
    • /
    • 2021
  • This paper aims to evaluating the interlayer strength of 3D-printed concrete with interlayer reinforcement. According to lap splices, two reinforcement methods were considered. One method did not include lap splices of interlayer reinforcement, but the other method included lap splices with length of 40mm. In addition, two different curing conditions were applied: air curing conditions and water curing conditions. The compressive, splitting tensile, and flexural tensile strengths of 3D-printed concrete specimens were measured in three loading directions with different reinforcement methods and curing conditions. Splitting and flexural tensile strengths decreased considerably when tensile stresses acted over the interlayers of 3D-printed concrete specimens. However, the flexural tensile strength or interlayer bonding strength of the printed specimens increased significantly at the interlayers when the longitudinal interlayer reinforcement penetrated printed layers. Interlayer bonding strength of printed concrete decreased after air curing treatment was applied because interlayers of printed concrete with more pores formed by the air cu ring conditions are more vulnerable to the load.

Acoustic Characteristics of Wedge-shaped Anechoic Tiles with Different Wedge-apex Angles (꼭지각이 다른 쐐기형 무반향 타일의 음향특성)

  • 김성기;이강일;윤석왕
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.5-11
    • /
    • 2001
  • Acoustic characteristics of the wedge-shaped anechoic tiles, used as absorbing lining materials for an anechoic water tank, were investigated for different wedge-apex angles. The anechoic tile base has the dimensions of 400mm x 385mm x 15.5mm. In order to investigate anechoic effect, the wedge-apex angles 30° and 60° were selected by using a ray-tracing method. The reflection loss of the anechoic tiles with and without wedges were experimentally studied at normal incident sound waves in water. In this experiment, the reflection loss of wedge-shaped anechoic tiles with the optimum wedge-apex angle 30° is larger than one with the angle 60° and one without wedges. The experimental results show that the wedge-shaped anechoic tiles with the wedge-apex angle 30°, optimized by using ray-tracing method, turn out better absorbing lining materials of an anechoic water tank.

  • PDF

An Experimental Study on the Bond Characteristic of GFRP Bars in PVA Fiber Reinforced Activated Hwangtoh Concrete (PVA 섬유보강 황토 콘크리트에 대한 GFRP 보강근의 부착성능에 관한 실험적 연구)

  • Park, Mi-Rae;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.134-141
    • /
    • 2017
  • Many studies have been conducted with respect to the materials to replace the cement in order to reduce the carbon dioxide emissions during the cement production. Activated hwangtoh as cement replacement material goes through calcination process of $850^{\circ}C$. PVA fibers and GFRP bars are used in order to compensate for the cracks of activated hwangtoh concrete(AHC). This paper presents an experimental study investigating the bond characteristic of GFRP bars in PVA fiber reinforced AHC under tensile loads. Experimental results showed that average bond strength factor of specimens with and without PVA fiber was 2.27~2.48 and was not significantly affected by the ratio of PVA fiber andactivated hwangtoh. In addition, as the bond length was increased, the bond strength was reduced.