• Title/Summary/Keyword: 재부착

Search Result 954, Processing Time 0.032 seconds

Theoretical Assessment of Flexural Strength of Unbonded FRP Prestressed Concrete Beams (비부착 FRP 프리스트레스트 콘크리트보의 휨내력 이론 산정)

  • Heo, Seo-Young;Lee, Cha-Don;Jeong, Sang-Mo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1045-1048
    • /
    • 2008
  • Fiber reinforced polymer (FRP) usually exhibits inherent brittleness under tensile stress. Application of FRP tendons to concrete beam leads to undesirable flexural behavior due to limited ductility compared to prestressed concrete beam with steel tendons. It has been experimentally observed that partial improvement of flexural behavior can be achieved by releasing FRP tendons' strain by unbonding FRP tendons. In order to estimate and apply the degree of improvement to the design, reasonable yet practical model predicting flexural strength as well as overall flexural behavior of unbonded FRP prestressed concrete beam is needed. In this study, an elaborated model in describing curvature distributions and flexural strength at ultimate stage of unbonded FRP tendons is described. There have been close agreements on the flexural strength of the FRP prestressed concrete beam between the predictions by nonlinear computer program and by the model.

  • PDF

Experimental Study on the Characteristics of Turbulent Wall Pressure Fluctuation Over Compliant Coatings (유연재 코팅 평판의 난류 변동압력 특성에 관한 실험적 연구)

  • Park, Kyung-Hoon;Lee, Seung-Jae;Shin, Ku-Kyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.6
    • /
    • pp.293-300
    • /
    • 2007
  • Turbulent boundary layer over an underwater vehicle is formed when it moves underwater and wall pressure fluctuation within the turbulent boundary layer generates flow-induced noise by exciting the elastic hull of the underwater vehicle. One of the methods to reduce this flow noise is to attach a compliant layer on the surface of the vehicle. In order to observe the possibility of noise reduction in the water when the compliant layer treatments are applied on the surface, three types of specimens those are a bare steel plate, a steel plate coated with neoprene and a steel plate with polyurethane coating material are tested at various flow speeds in a low noise cavitation tunnel. This paper presents the results of measurements and analysis of wall pressure fluctuations which is a main source of flow noise, within the turbulent boundary layer on three specimens. Its results could be shown that about 10dB reduction of wall fluctuation pressure at high frequencies was achieved due to the dissipation of turbulent energy by the compliant coating while it makes the turbulent boundary layer thicker and changes the behavior of turbulent flow in the layer.

Tests on Transfer Bond Performance of Epoxy Coated Prestressing Strands (에폭시 코팅 처리된 PS강선의 정착부착성능 실험)

  • 유승룡
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.1
    • /
    • pp.89-100
    • /
    • 1994
  • The current test procedure for transfer length, which determine transfer length by measuring concrete strain, has an actual bond stress state in the prestressed pretensioned member : however, it is difficult to determine the bond properties of maximum bond stress and bond stiffness with this method. It is also difficult for design engineer to understand and select a correct safety criterion from the widely distributed results of such a ransfer test alone. An alternative testing procedure is provided here to determine the bond properties without measuring the concrete strain. In this test the bond stress is measured directly by creating a similar boundary condition within the transfer length in a real beam during the transfer of prestressing force. The prestressing force was released step by step by step from the unloading side. The release of force induces a swelling of the strand at the unloading side of concrete block, bonding force in the block, and a bond slip of the strand toward the other side of the block. Two center-hole load cells are used to record the end loads until the point of general bond slip(maximum bond stress). It is suggested that this test procedure be performed with the ordinary transfer test when determining the transfer length in a prestressed, pretensioned concrete beam.

One-visit Apexification Using MTA and Reattachment of a Crown-root Fractured Tooth with Severe Coronal Damage: A Case Report (심한 치관 손상이 발생한 치관-치근 파절 치아의 일회 내원 치근관형성술 및 파절편 재부착 : 증례 보고)

  • Park, Youngjun;Lee, Jewoo;Ra, Jiyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.4
    • /
    • pp.521-527
    • /
    • 2018
  • In dental trauma, reattachment of the original tooth fragment improves the reproduction of original tooth shape, texture, color, and radiolucency; thus, it provides good aesthetics. A 9-year-old boy was referred due to complicated crown-root fracture of the maxillary right central incisor. Although it had poor prognosis due to severe coronal damage and subcrestal fracture, reattachment of the tooth fragment was chosen due to the patient's age. One-visit apexification with mineral trioxide aggregate (MTA) was performed, followed by osteotomy and reattachment of the tooth fragment with post placement. Regular observation revealed no clinical signs or symptoms and no radiologic complications.

An Analytical Study for Structural Behaviors of Unbonded Precast Rectangular Hollow Section Concrete Piers (비부착 프리캐스트 중공 사각 단면 교각의 구조거동에 관한 해석적 연구)

  • Choi, Seung-Won;Kim, Ick-Hyun;Cho, Jae-Yeo;Chang, Sung-Pil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1A
    • /
    • pp.61-69
    • /
    • 2010
  • Unbonded precast concrete piers have better seismic performances than conventional reinforced concrete piers. In this research, seismic performances of unbonded precast prestressed concrete piers are analyzed using OpenSEES. Main parameters of analysis are concrete strength, jacking force ratio, ratio of tendon, and size of precast segment. In results, as the ratio of tendon and jacking force ratio increase, the flexural strength increases at softening state and ultimate state. Concrete strength and size of precast segment are negligible. But initial jacking force ratio leads to early yielding of prestressing tendon. Since compressive strain in core concrete is much less than ultimate strain, it can be expected that the amount of transverse steel reinforcement is to be reduced in comparison with conventional reinforced concrete column.

The Effects of Tooth Bleaching Agents on Microhardness of Enamel in situ (수종 치아미백제가 구강내에서 법랑질의 미세경도에 미치는 영향)

  • Park, Yoon-Woo;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.470-476
    • /
    • 2006
  • The objective of this in situ study was to evaluate the effects of whitening strip (Claren, LG Household & Health Care Ltd, 2.6% hydrogen peroxide) and gel (Opalescence, Ultradent, 10% carbamide peroxide) on microhardness of enamel in comparison with untreated control. Extracted twenty human upper incisors were disinfected, cleaned, and labial side of each incisor sectioned into 3 fragments by 2 ${\times}$ 2 mm size. After sectioning, labial sides of fragments were flattened and fixed to orthodontic bracket using flowable composite resin. Specimens prepared from each tooth were attached to the labial side of upper incisors of twenty volunteers one by one and treated by three different methods: (1) untreated control (2) treated with whitening strip for 14 days (3) treated with whitening gel for 14 days. Microhardness (Microhardness tester, Zwick) of each specimen was measured at the baseline of pre-treatment, immediate after bleaching treatment, 14 days after bleaching treatment and Knoop Hardness Number was determined. Microhardness changes of experimental groups were compared. The results show that tooth whitening strip and gel used in this study does not effect the microhardness of enamel during bleaching procedure.

Bond Behavior of GFRP Rebars Embedded in Concrete Under Cyclic Loading (반복하중을 받는 GFRP 보강근의 부착특성)

  • Cheong, Yeon-Geol;Yi, Chong-Ku;Lee, Jung-Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.101-104
    • /
    • 2008
  • The cost of repairing the deterioration of concrete structures due to corrosion of the reinforcement steel has been the prominent figure in the maintenacne of the reinforced-concrete infrastructures. As an alternative material to steel reinforcement, the use of Fiber Reinforced Polymer (FRP) bar in concrete is being actively studied for the high resistance of chemical environment and high strength to weight ratio properties of FRP. However, there remain various aspects of FRP properties that still need to be studied before the standard design criteria can be established. One of the imminent issues is the bond between FRP and concrete. In this study, the bond-behavior of FRP bars in concrete is investigated via the pullout test with three varying parameters: surface condition of FRP bars, concrete compression strength, and cyclic loading patterns. As a result of experiment, the bond strength of GFRP increased with the concrete compression strength increasing and decreased with applying cyclic load.

  • PDF

Experimental Examination of Influential Variables on Unbonded Tendon Stresses (비부착 긴장재의 응력에 영향을 미치는 중요변수에 대한 실험연구)

  • Lim, Jae-Hyung;Moon, Jeong-Ho;Lee, Li-Hyung
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.1
    • /
    • pp.209-219
    • /
    • 1999
  • This paper describes an experimental study planned to examine the effects of important design variables which were used in the proposed equation by authors. Fourteen beams and slabs were designed with the variables, such as effective prestress, concrete strength, amount of tendons, amount of bonded reinforcements, loading type, and span/depth ratio. Then, deflections and tendon stresses were measured and compared according to the parametric variations of the selected variables. It was found that the tendon stress increment decreases as the level of effective prestress or the amount of unbonded tendons and bonded reinforcements increases. Also, the contributions of concrete strength, and loading type were observed to affect on the tendon stresses. However, the stress increments of unbonded tendon were minimal alt high values of span/depth in contrast with the ACI code.