• Title/Summary/Keyword: 재동기

Search Result 105, Processing Time 0.029 seconds

Scale Thickness Measurement of Steam Generator Tubing Using Eddy Current Signal of Bobbin Coil (보빈코일 와전류신호를 이용한 증기발생기 세관 스케일 두께 측정)

  • Kim, Chang-Soo;Um, Ki-Soo;Kim, Jae-Dong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.545-550
    • /
    • 2012
  • Steam generator is one of the major components of nuclear power plant and steam generator tubes are the pressure boundary between primary and secondary side, which makes them critical for nuclear safety. As the operating time of nuclear power plant increases, not only damage mechanisms but also scaled deposits on steam generator tubes are known to be problematic causing tube support flow hole blockage and heat fouling. The ability to assess the extent and location of scaled deposits on tubes became essential for management and maintenance of steam generator and eddy current bobbin data can be utilized to measure thickness of scale on tubes. In this paper, tube reference standards with various thickness of scaled deposit has been set up to provide information about the overall deposit condition of steam generator tubes, providing essential tool for steam generator management and maintenance to predict and prevent future damages. Also, methodology to automatically measure scale thickness on tubes has been developed and applied to field data to estimate overall scale amount.

Research of High Efficiency Integrated Reforming System Using Separated Reforming System (분리형 개질기를 이용한 고효율 일체형 개질기 개발에 관한 연구)

  • PARK, SANG-HYOUN;KIM, CHUL-MIN;SON, SUNG-HYO;JANG, SE-JIN;KIM, JAE-DONG;BANG, WAN-KEUN;LEE, SANG-YONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.1
    • /
    • pp.11-18
    • /
    • 2018
  • A high efficiency integrated reforming system for improving the efficiency of the 5 kW PEMFC system used as the back up power of building was studied. The separated reforming system consisted of three parts - A steam reformer with two stage concentric circular shape, a heat exchanger type steam generator and a CO shift reactor. Temperature and steam carbon ratio (SCR) were control variables during operation. The operating conditions were optimized based on the thermal efficiency of the steam reformer as reformate gas composition changes at different temperature. In experiments, water was fully vaporized in the steam generator up to SCR 3.5 and the maximum thermal efficiency was achieved at the operating temperature around $700^{\circ}C$ in the steam reforming reactor. With the results of the separated reforming system research, we improved the shape of high efficiency integrated reformer. The performance evaluation of the integrated reformer was based on optimized operating conditions in SCR 3.5. As a result, the developed integrated reforming system maintained an efficiency of 76% and constant performance over 3,000 hours.

A Study on the characteristics of the bed porosity and organic wastewater treatment with the circulation velocity in the anaerobic fluidized bed biofilm reactorA Study on the characteristics of the bed porosity and organic wastewater treatment with the circulation velocity in the anaerobic fluidized bed biofilm reactor (혐기성 유동층 생물막 반응기에서 순환유속 증가에 따른 층공극률 및 유기성 폐수 처리특성에 관한 연구)

  • 김재우;안재동
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.3
    • /
    • pp.1.1-15
    • /
    • 1995
  • This study was performed to estimate the characteristics of the organic wastewater treatment and bed porosity with the circulation velocity in the anaerobic fluidized bed biofilm reactor. The results were as follows; 1. With Increasing circulation velocity the fluidized bed expanded smooth and with increasing initial particle volume the fluidized bed was increased. 2. With increasing circulation velocity the gasproduction was increased, but at 1.Scnt/sec of circulation velocity AFBBR showed the highest value of methane production rate per removed COD. Therefore, for the purpose of economical operation in AFBBR, 1.5cm/sec of circulation velocity was optimum 3. The microorganisms were colonized in the crevice of the media. 4. On fluidization, COD, VA,55 profiles with the reactor height were not showed. In conclusion, AFBBR suit the organic wastewater treatment's purpose, and at 1.5cm/sec of circulation velocity the system is economical in an energy Point of view.

  • PDF

A Study on the Treatment of Phenol Wastewater in an Anaerobic Fluidized-Bed Reactor (혐기성 유동층 반응기에서 페놀 폐수 처리에 관한 연구)

  • 박동일;안재동;신승훈;장인용
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.2
    • /
    • pp.96-103
    • /
    • 1996
  • The objectives of this study were to examine the biodegradation of phenol using the anaerobic fluidized bed reactor(AFBR). Mixed microorganisms were selected from the anaerobic digestion tank, and could be adapted to high concentration of phenol by increasing the phenol concentration 600-3600 mg/l step by step. The results were summarized as follows: 1. The average removal efficiency of phenol was 90%, decreased by increasing concentration of phenol, and then a shock range was 1200~2400 ppm. 2. The production rate of biogas in overall limits was proportional to the concentration of influent phenol. 3. At steady state, compositions of gases were $CH_4$ 55~60%, $C0_2$ 34~43%, respectively. These were similar to that of the theoretical estimates. 4. The production rates of biogas and methane per the molarity of phenol removed were linearly increased, 56.45 l gas/mol-phenol and 29.20 l $CH_4/mol$-phenol. Using this biogas, the recoverable energy was 269.1 kcal/mol phenol. It was 120.2 kcal/g-COD, transforming into the chemical oxygen demand. 5. The bulk of microorganisms existed in suspended section of fluidized bed with type of biofilm and its concentration was 340 mg/g-media. In conclusion, the anaerobic treatment of pure phenol was possible and its removal efficiency, introducing the AFBR, was successful. Also toxic organic compound such as phenol was biodegradable and was recoverable as resource of energy.

  • PDF

The High Rate Denitrification of Nitric Acid Wastewater in a Fluidized Bed Biofilm Reactor (유동층 생물막 반응기를 이용한 고농도 질산성 폐수의 탈질화에 관한 연구)

  • 신승훈;김민수;박동일;안재동;장인용
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.1
    • /
    • pp.95-104
    • /
    • 1997
  • The objectives of this study are to investigate the effect of media on the removal efficiency of nitrate-nitrogen and the biofilm thickness in the fluidized bed biofilm reactor(FBBR) used for the high rate denitrification of nitric acid wastewater. Granular activated carbon(GAC) of 1.274 mm diameter and sand of 0.455 mm diameter were used as the media in the FBBR of 0.05 m diameter and 1.5 m height. As the nitrate-nitrogen concentration of the influent was increased stepwise from 600 to 4800 mg/l, the nitrate- and nitrite-nitrogen concentration of the effluent, biofilm thickness and biofilm dry density were measured to study the effects of media on the denitrification efficiency. The biofilm thickness increased with the substrate loading rate, and the biofilm dry density decreased with the increase of the biofilm thickness. At the influent nitrate-nitrogen concentration of 2400 mg/l, the removal efficiency in the FBBR with GAC was 88%, while that in the FBBR with sand was 99.6%. The biofilm in the FBBR with GAC was so thick, 754.9 $\mu$m, as to increase the mass transfer resistance, compared to that, 143.7 $\mu$m, in the FBBR with sand. The maximum specific denitrification rate in the FBBR with GAC was 15.0 kg-N/m$^3\cdot$ day, while that in the FBBR with sand was 18.0 kg-N/m$^3\cdot$ day. The biomass concentration in the FBBR with sand exhibited the high value 37 kg/m$^3$.

  • PDF

The Characteristics of Attached Biomass and Biogas Production in an Anaerobic Packed Bed Bioreactor with Several Carriers (혐기성 고정상 생물반응기에서 담체의 종류에 따른 Biogas 생성 및 미생물 부착 특성에 관한 연구)

  • 안재동;강동수;장인용
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.2
    • /
    • pp.75-81
    • /
    • 1992
  • An experimental investigation has been carried out to evaluate the characteristics in wastewater treatment using an anaerobic packed bed bioreactor with ceramics, rubber sponge, soft stone A, and soft stone B as carrier. The results of the work have shown that soft stone A as a carrier was superior to other carriers in methane production, then the content of methane for soft stone A was about 70%. First of all, soft stone A had higher efficiency of the COD removal than the others in response of passing the operation, as well as it had a low volatile acid in reactor. In addition, the slope of methane production with respect to the removal of COD ($m^{3}CH_{4}$/kgCOD) was 0.58 for soft stone A. In biomass hold-up equation for each carriers, the equation of soft stone A was m$_{p}$=714 ($C_{o}/0.41+C_{o}$) and it was the largest in this experimented carriers. Based upon the results obtained, it is suggested that the major effective carrier in wastewater treatments within the packed bed bioreactor used in this experimental work by soft stone A.

  • PDF

Sensorless speed control of a Switched Reluctance Motor using Fuzzy position estimation algorithm (퍼지회전자 위치평가 알고리즘을 이용한 SRM센서리스 속도제어에 관한 연구)

  • 최재동;김갑동;안재황;성세진
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.343-351
    • /
    • 2000
  • This paper introduces a new rotor position estimation algorithm for the Switched Reluctance Motor, based on the magnetizing curves only at aligned and unaligned rotor positions. The flux linkage is calculated by measured data from phase voltage and phase current, and calculated data are used as the input of magnetizing profiles for rotor position detection. The fuzzy flux observer using novel knowledge-based fuzzy controller are presented to achieve sensorless control of the SRM. The method for selecting optimal angle is proposed for the rotor position detection. The robustness of the proposed algorithm is proved through the comparison of the simulation and experimental results.

  • PDF

Development of VDS for Geosynchronous Satellite and Verification using PILS & HILS (정지궤도위성 실시간 동역학 시뮬레이터 개발 및 연동시험을 통한 검증)

  • Park, Yeong-Ung;Gu, Ja-Chun;Choe, Jae-Dong;Gu, Cheol-Hoe;Park, Bong-Gyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.1
    • /
    • pp.103-109
    • /
    • 2006
  • In this paper, VDS(Vehicle Dynamics Simulator) and ACS(Attitude Control Simulator) are developed and are verified using PILS(Process In-the Loop Simulation) between VDS and ACS. VDS is including the AOCS(Attitude & Orbit Control Subsystem) hardware modeling of geosynchronous satellite and consists of modulation concept. ACS performs the attitude determination using sensor data and generates the attitude control commands. In order to transfer the data between VDS and PCDU(Power Control & Distribution Unit), data acquisition boards were mounted. VDS performance is verified using HILS(Hardware In-the Loop Simulation) between VDS and PCDU.

Satellite Battery Cell Voltage Monitor System Using a Conventional Differential Amplifier (종래의 차동증폭기를 사용한 인공위성 배터리 셀 전압 감시 시스템)

  • Koo, Ja-Chun;Choi, Jae-Dong;Choi, Seong-Bong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.2
    • /
    • pp.113-118
    • /
    • 2005
  • This paper shows a satellite battery cell voltage monitor system to make differential voltage measurements when one or both measurement points are beyond voltage range allowed by a conventional differential amplifier. This system is particularly useful for monitoring the individual cell voltage of series-connected cells that constitute a rechargeable satellite battery in which some cell voltages must be measured in the presence of high common mode voltage.

Polarization Characteristics of Heat-treated Ni-based Self-flux Alloy Coating in Alkaline Solution (후열처리한 니켈기 자융성 합금 코팅의 알칼리 용액에서의 분극특성)

  • Kim, Tea-Yong;Kim, Jea-Dong;Kim, Yeong-Sik
    • Journal of Power System Engineering
    • /
    • v.18 no.2
    • /
    • pp.37-42
    • /
    • 2014
  • The purpose of this paper is to investigate polarization characteristics of heat-treated Ni-based self-flux alloy coating in alkaline solution. Ni-based self-flux alloy powder was sprayed to a steel substrate using flame spray process, and heat treatments were performed in a vacuum furnace at $800^{\circ}C$, $900^{\circ}C$, $1000^{\circ}C$ and $1100^{\circ}C$. After heat treatments, corrosion tests were carried out using potentiostat/galvanostat at solution with pH 8 and pH 13. Corrosion potential(Ecorr) and corrosion current density(Icorr) could be analyzed from polarization curve. Anticorrosive effect of heat-treated coating at solution with pH 8 was relatively greater than at solution with pH 13. Heat-treated coating at $1100^{\circ}C$ showed the greatest anti-corrosion characteristics in alkaline solution.