• Title/Summary/Keyword: 재건오차

Search Result 8, Processing Time 0.024 seconds

Proper Orthogonal Decomposition Analysis of Dynamic Wind Pressures Acting on a Tall Tower Model (고층 타워에 작용하는 동적 풍압력의 POD 방법을 이용한 시공간적 특성 해석)

  • Yi, Mee-Hwa;Ham, Hee-Jung
    • Journal of Industrial Technology
    • /
    • v.24 no.B
    • /
    • pp.29-36
    • /
    • 2004
  • The wind and wind-induced dynamic wind pressures fluctuate irregularly according to time and space. In this study, the proper orthogonal decomposition(POD) technique is applied to wind pressures acting on a tall tower model, and the following results are found: the along-wind and across-wind forces can be reconstructed by only four dominant POD modes, and the reconstructed errors are 4.71% and 22%, respectively for across-wind and along-wind directions. The physical meanings for dominant modes are also presented in the paper. The POD analysis can compress complex wind pressure data only by a few dominant modes and interpret spatio-temporal characteristics of wind pressure by novel way while existing statistical methods do not have such benefits.

  • PDF

Band-pass Filter based Artificial Filter Bank for Structural Health Monitoring (구조 건전도 모니터링을 위한 대역통과필터 기반 인공필터뱅크)

  • Heo, Gwanghee;Jeon, Joonryong;Jeon, Seunggon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.12
    • /
    • pp.843-855
    • /
    • 2015
  • This study developed a band-pass filter based artificial filter bank(BAFB) based on that in order to efficiently obtain the significant dynamic responses. The BAFB was then optimized about the El-centro earthquake wave which was often used in the construction research, and the software implementation of BAFB was finally embedded in the wireless unified management system(WiUMS). For the evaluation of the developed BAFB, a real time dynamic response experiment was performed on a cable-stayed bridge model, and the response of the cable-stayed bridge model was measured using both the traditional wired system and the developed BAFB-based WiUMS. The experiment results showed that the compressed dynamic response acquired by the BAFB-based WiUMS matched significantly with that of the traditional wired system while still carrying sufficient modal information of the cable-stayed bridge. Finally, the developed BAFB was able to reconstruct or re-sample the dynamic response wholly from the compressed response signal, and it can be applied as a new kind of measurement system for a wireless sensor networks based structural health monitoring system that secures both economy and efficiency.

Computer-Assisted Orthopaedic Surgery in Bone Tumor (항법장치를 이용한 골종양 수술)

  • Cho, Hwan-Seong;Park, Il-Hyung;Mun, Jong-Uk;Kim, Han-Soo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.15 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • The usefulness and accuracy of computer-assisted surgery have been evaluated clinically in many orthopedic fields, such as, joint replacement arthroplasty, cruciate ligament reconstruction, and pedicle screw placemen. Recently several preliminary reports have been issued on the application of navigation to bone tumor surgery. The main advantage of navigation-assisted bone tumor surgery is that it provides highly accurate three-dimensional radiological information for intraoperative guidance. In particular, distances from tumors to resection margins can be precisely determined using intraoperative three-dimensional images. Accordingly, the technique allows preservation of function to be maximized by minimizing unnecessary resection. However, surgeons should recognize that the accuracies of navigation systems in bone tumor surgery have some hidden pitfalls. Here, based on our clinical results, we describe the surgical techniques used and include some cautionary notes.

  • PDF

Barrier Techniques for Spinal Cord Protection from Thermal Injury in Polymethylmethacrylate Reconstruction of Vertebral Body : Experimental and Theoretical Analyses (Polymethylmethacrylate를 이용한 척추체 재건술에서 척수의 열 손상을 방지하기 위한 방어벽 기법 : 실험적 및 이론적 분석)

  • Park, Choon Keun;Ji, Chul;Hwang, Jang Hoe;Kwun, Sung Oh;Sung, Jae Hoon;Choi, Seung Jin;Lee, Sang Won;Park, Sung Chan;Cho, Kyeung Suok;Park, Chun Kun;Yuan, Hansen;Kang, Joon Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.3
    • /
    • pp.272-277
    • /
    • 2001
  • Objective : Polymethylmethacrylate(PMMA) is often used to reconstruct the spine after total corpectomy, but the exothermic curing of liquid PMMA poses a risk of thermal injury to the spinal cord. The purposes of this study are to analyze the heat blocking effect of pre-polymerized PMMA sheet in the corpectomy model and to establish the minimal thickness of PMMA sheet to protect the spinal cord from the thermal injury during PMMA cementation of vertebral body. Materials & Methods : An experimental fixture was fabricated with dimensions similar to those of a T12 corpectomy defect. Sixty milliliters of liquid PMMA were poured into the fixture, and temperature recordings were obtained at the center of the curing PMMA mass and on the undersurface(representing the spinal cord surface) of a prepolymerized PMMA sheet of variable thickness(group 1 : 0mm, group 2 : 5mm, or group 3 : 8mm). Six replicates were tested for each barrier thickness group. Results : Consistent temperatures($106.8{\pm}3.9^{\circ}C$) at center of the curing PMMA mass in eighteen experiments confirmed the reproducibility of the experimental fixture. Peak temperatures on the spinal cord surface were $47.3^{\circ}C$ in group 2, and $43.3^{\circ}C$ in group 3, compared with $60.0^{\circ}C$ in group 1(p<0.00005). So pre-polymerized PMMA provided statistically significant protection from heat transfer. The difference of peak temperature between theoretical and experimental value was less than 1%, while the predicted time was within 35% of experimental values. The data from the theoretical model indicate that a 10mm barrier of PMMA should protect the spinal cord from temperatures greater than $39^{\circ}C$(the threshold for thermal injury in the spinal cord). Conclusion : These results suggest that pre-polymerized PMMA sheet of 10mm thickness may protect the spinal cord from the thermal injury during PMMA reconstruction of vertebral body.

  • PDF

A STUDY ON ACCURACY OF MAXILLARY REPOSITIONING BY EXTERNAL MEASURING TECHIQUE (외부계측법에 의한 상악골 이동의 위치적 정확도에 대한 평가 연구)

  • Park, Hyung-Sik;Cha, In-Ho;Park, Hyung-Rae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.1
    • /
    • pp.44-52
    • /
    • 1991
  • Internal measurement technique has been commonly and classically used to guide down-fractured maxilla by Le Fort I osteotomy into its new position during intraoperative procedure for correlating preoperative model works with surgery. However, It has been challenged now by several authors due to some problems as its inaccuracy in three-dimensional changes at surgery, difficulty to measure during surgery and impossibility of rechecking at the end of surgery etc. The purpose of this study was to evaluate the accuracy of maxillary movement by external measuring technique and to determine its accuracy between the prediction tracing and a new maxillary position. The results indicate that the external measuring technique was predictable in the vertical, horizontal and transverse change of the maxilla as its prediction, however, it has a tendency to shift the maxilla more anterior and inferior in overall direction than prediction. Post-operative canting difference were mimic, however Ehange of the maxillary dental midline was large and had a right-shifting tendency.1 The precise methods to keep maxillary dental midline as same as prediction and the avoidance of uneven force applied to the mandible for autorotation should be necessary during surgery in use of external measurement technique.

  • PDF

Mitral Reconstruction Using Prosthetic Ring in Mitral Valvular Heart Disease (승모판막질환에 있어서 인공판륜을 이용한 승모판막재건술의 임상적 고찰)

  • 나명훈;황경환
    • Journal of Chest Surgery
    • /
    • v.30 no.6
    • /
    • pp.598-606
    • /
    • 1997
  • Among 136 patients having undergone mitral valve surgery from September of 1994 through August of 1995 in Sejong Heart Institute, forty four patients(18 males, 26 females) underwent mitral valve reconstruction using prosthetic rings and their clinical results were evaluated. Patients'ages ranged from 5 to 63 years(mean age 38.2 years). Mitral valvular diseases were due to rheumatic origin in 30 patients(68%), degenerative in 13(30%), and congenital in one patient(2%). Mitral regurgitation(MR) was in 33 patients(76%), mitral stenosis 2(5%), and mitral stenoinsufaciency 9 patients(19%). The patients were divided into Carpentier's functional groups : type I, 5 patients(11%) : type I, 24 patients(55%) ; type III, 4 patients (9%) i and mixed(II + III), 11 patients(25%). Average number of anatomic lesions of mitral valve per patient was 3.7. The techniques included prosthetic ring amluloplasty(44 patients, 32 Carpentier ring and 12 Duran ring), leaflet mobilization(24, 55%), chordae shortening(23, 52%), chordae transposition(23, 52%), commissurotomy(16, 35%), leaflet resection(9, 20%), papillary muscle splitting(8, 18%), and chordae reimplantation(1, 2%). Average 3.4 surgical procedures were applied on mitral valve per patient. There were two hospital mortality and one reoperation due to development of MR(grade III) after 2 weeks. During the mean follow up of 12 months, patients improved in terms of functional class of the New York Heart Association, which was mean 3.0 preoperatively and 1.3 postoperatively. Doppler echocardiographic studies showed adequate valve area(2.07$\pm$0.11 cm2 mean $\pm$standard error), improved ventricular contractiliy in 41 patients(93%), ab ence of MR in 23(53%), trace MR in 18(42%), and garde II MR in 2 patients(5%).

  • PDF

Compression Sensing Technique for Efficient Structural Health Monitoring - Focusing on Optimization of CAFB and Shaking Table Test Using Kobe Seismic Waveforms (효율적인 SHM을 위한 압축센싱 기술 - Kobe 지진파형을 이용한 CAFB의 최적화 및 지진응답실험 중심으로)

  • Heo, Gwang-Hee;Lee, Chin-Ok;Seo, Sang-Gu;Jeong, Yu-Seung;Jeon, Joon-Ryong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.23-32
    • /
    • 2020
  • The compression sensing technology, CAFB, was developed to obtain the raw signal of the target structure by compressing it into a signal of the intended frequency range. At this point, for compression sensing, the CAFB can be optimized for various reference signals depending on the desired frequency range of the target structure. In addition, optimized CAFB should be able to efficiently compress the effective structural answers of the target structure even in sudden/dangerous conditions such as earthquakes. In this paper, the targeted frequency range for efficient structural integrity monitoring of relatively flexible structures was set below 10Hz, and the optimization method of CAFB for this purpose and the seismic response performance of CAFB in seismic conditions were evaluated experimentally. To this end, in this paper, CAFB was first optimized using Kobe seismic waveform, and embedded it in its own wireless IDAQ system. In addition, seismic response tests were conducted on two span bridges using Kobe seismic waveform. Finally, using an IDAQ system with built-in CAFB, the seismic response of the two-span bridge was wirelessly obtained, and the compression signal obtained was cross-referenced with the raw signal. From the results of the experiment, the compression signal showed excellent response performance and data compression effects in relation to the raw signal, and CAFB was able to effectively compress and sensitize the effective structural response of the structure even in seismic situations. Finally, in this paper, the optimization method of CAFB was presented to suit the intended frequency range (less than 10Hz), and CAFB proved to be an economical and efficient data compression sensing technology for instrumentation-monitoring of seismic conditions.

A Novel Volumetric Method for Quantitation of Titanium Dioxide in Cosmetics (용량분석법을 이용한 화장품 중 티타늄옥사이드의 정량)

  • Kim, Young-So;Kim, Boo-Min;Park, Sang-Chul;Jeong, Hye-Jin;Chang, Ih-Seop
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.4 s.54
    • /
    • pp.289-293
    • /
    • 2005
  • Nowadays there are many sun protection cosmetics including organic or inorganic UV filter as an active ingredient. Chemically stable inorganic sunsEreen agents, usually metal oxides, we widely employed in high SPF products. Titanium dioxide is one of the most frequently used inorganic UV filters. It has been used as pigments for a long period of cosmetic history. With the development of micronization techniques, it becomes possible to incorporate titanium dioxide in sunscreen formulations without whitening effect and it becomes an important research topic. However, there are very few works related to quantitations of titanium dioxide in sunscreen products. In this research, we analyzed amounts of titanium dioxide in sunscreen cosmetics by adapting redof titration, reduction of Ti(IV) to Ti(III) and reoxidation to Ti(IV). After calcification of other organic ingredients of cosmetics, titanium dioxide is dissolved by hot sulfuric acid. The dissolved Ti(IV) is reduced to the Ti(III) by adding aluminum metals. The reduced Ti(III) is titrated against a standard oxidizing agent, Fe(III) (ammonium iron(III) sulfate), with potassium thiocyanate as an indicator In order to test accuracy and applicability of the proposed method, we analyzed the amounts of titanium dioxide in four types of sunscreen cosmetics, such as cream, make-up base, foundation and powder, after adding known amounts of titanium dioxide $(1{\sim}25w/w%)$. The percent recoveries of the titanium dioxide in four types of formulations were in the range between 96 and 105%. We also analyzed 7 commercial cosmetic products labeled titanium dioxide as an ingredient and compared the results with those of obtained from ICP-AES (Inductively Coupled Plasma-Atomic Emission Spectrometry), one of the most powerful atomic analysis techniques. The results showed that the titrated amounts were well coincided with the analyzed amounts of titanium dioxide by ICP-AES. Although instrumental analytical methods, ICP-MS (Inductively Coupled Plasma-Mass Spectrometry) and ICP-AES, are the best for the analysis of titanium, it is hard to adopt because of their high prices for small cosmetic companies. It was found that the volumetric method presented here gat e quantitative and reliable results with routine lab-wares and chemicals.