• Title/Summary/Keyword: 재가동

Search Result 34, Processing Time 0.021 seconds

The Changes of Cerebral Metabolic Parameters, Serum Levels of Neuron-Specific Enolase and S-100$\beta$ Protein During Retrograde Cerebral Perfusion Under Profound Hypothermic Total Circulatory Arrest (초저체온하 완전순환정지 시에 이용되는 역행성 뇌관류의 시간에 따른 뇌대사 지표, 혈청 내 neuron-specific enolase, 및 S-100 베타단백의 변화)

  • 김경환
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.653-661
    • /
    • 2001
  • Background: Retrograde cerebral perfusion(RCP) is one of the methods used for brain protection during aortic arch surgery. The author previously published the data, however, for the safety of it, there still remains many controversies. The author performed RCP and checked various parameters to clarify the possibility of early detection of cerebral injury. Material and Method: The author used pigs(Landrace species) weighing 25 to 30kg and performed RCP for 120 minutes. After weaning of cardiopulmonary bypass, we observed pigs for another 120 minutes. Rectal temperature, jugular venous oxygen saturation, central venous pressure were continuously monitored, and the hemodynamic values, histological changes, and serum levels of neuron-specific enolose(NSE) and S100$\beta$ protein were checked. Central venous pressure during RCP was maintained in the range of 20 to 25 mmHg. Result: Flow rates(ml/min) during RCP were 224.3$\pm$87.5(20min), 227.1$\pm$111.0(40min), 221.4$\pm$119.5(60min), 230.0$\pm$136.5(80min), 234.3$\pm$146.1(100min), and 184.3$\pm$50.5(120min). Serum levels of NSE did not increase after retrograde cerebral perfusion. Serum levels of S100$\beta$ protein(ng/ml) were 0.12$\pm$0.07(induction of anesthesia), 0.12$\pm$0.07(soon after CPB), 0.19$\pm$0.12(20min after CPB), 0.25$\pm$0.06(RCP 20min), 0.29$\pm$0.08(RCP 40min), 0.41$\pm$0.05(60min), 0.49$\pm$0.03(RCP 80min), 0.51$\pm$0.10(RCP 100min), 0.46$\pm$0.11(RCP 120min), 0.52$\pm$0.15(CPBoff 60min), 0.62$\pm$0.15(60min after rewarming), 0.76$\pm$0.17(CPBoff 30min), 0.81$\pm$0.20(CPBoff 60min), 0.84$\pm$0.23(CPBoff 90min) and 0.94$\pm$0.33(CPBoff 120min). The levels of S100$\beta$ after RCP were significantly higher than thosebefore RCP(p<0.05). The author could observe the mitochondrial swellings using transmission electron microscopy in neocortex, basal ganglia and hippocampus(CA1 region). Conclusion: The author observed the increase of serum S100$\beta$ after 120 minutes of RCP. The correlation between its level and brain injury is still unclear. The results should be reevaluated with longterm survival model also considering the confounding factors like cardiopulmonary bypass.

  • PDF

Clinical Application of Stent-graft in Thoracic Aortic Diseases (흉부 대동맥 질환에서 스텐트-그라프트의 임상적 적용)

  • Kim, Kyung-Hwan;Lee, Cheul;Chang, Ji-Min;Chung, Jin-Wook;Ahn, Hyuk;Park, Jae-Hyung
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.698-703
    • /
    • 2001
  • Background: Endovascular stent-graft insertion in aortic diseases is now generally accepted as an attractive alternative treatment modality. We reviewed our clinical experiences of endovascular stent-graft insertion in thoracic aorta. Material and Method: Since 1995, we performed 8 cases of endovasclar stent-graft insertion. Preoperative diagnoses were aortic aneurysms in 4, traumatic aortic ruptures in 3, and ruptured aortic pseudoaneurysm in 1. All procedures were performed in angiography room with the guidance of fluoroscopy. The stent-graft device is a custom-made 0.35mm thickness Z-shaped stainless steel wires, intertwined with each other using polypropylene suture ligation. It is covered with expanded Dacron vascular graft. Result: All procedures were performed successfully. Follow-up studies revealed 2 minimal perigraft leakages. There was no significant leakage or graft migration. 2 patients expired due to multiple organ failure and fungal sepsis. Other survivors(6) are doing well. Conclusion: Endovascular stent-graft insertion is relatively saft and effective treatment modality in the managment of various types of aortic diseases. In may be an effective alternative in aortic diseases of great surgical risk.

  • PDF

Detection of Respiratoiry Tract Viruses in Busan, 1997-2000 (1997-2000년 부산지역 호흡기계 바이러스의 탐색)

  • 조경순;김영희
    • Korean Journal of Microbiology
    • /
    • v.37 no.4
    • /
    • pp.284-288
    • /
    • 2001
  • Respiratory viruses are one of the most infectious agent in human. Six different respiratory tract viruses were detected from Busan while working on the preventive surveillance in 1997-2000. The isolation rate from suspected specimens were 8.4%. Influenza virus A, B type, parainfluenza virus, adenovirus, mumps virus, and measles virus were examined from throat swabs, serum, and secretions of patients. Influenza A/Sydney/05/97(H3N2)-like, A/Johanesburg/33/94(H3N2)-like, A/Beijing/262/95(H1N1)-like and Influenza B/Beijing/262/95-like, B/Harbin/07/94-like, B/Guangdong/08/93-like were found. Adenovirus serotype 1, 2, 3 and 5 were detected, antibody of mumps both IgM and IgG were shown and outbreaks of measles were confirmed. Different antigenic types of influenza virus were detected every year, one outbreak of parainfluenza in 1999, mumps outbreak in 1999 and 2000, and incidence of measles in 2000 were noticeable. Monthly outbreaks were November through following March with influenza virus, January through June with adenovirus, February through May and December with mumps, April through August and November, December with measles, respectively. The size of isolated viruses were 130 nm with influenza virus B type, non-enveloped, icosahedron with 70 nm with adenovirus, 170 nm with mumps virus and 180 nm with parainfluenza virus in diameter, respectively.

  • PDF

A Numerical Study for Effective Operation of MSW Incinerator for Waste of High Heating Value by the Addition of Moisture Air (함습공기를 이용한 고발열량 도시폐기물 소각로의 효율적 운전을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Shin, Na-Ra;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.115-123
    • /
    • 2013
  • Stoker type incinerator is one of the most popular one used as municipal solid waste (MSW) incineration because, in general, it is quite suitable for large capacity and need no preprocessing facility. Nowadays, however, since the combustible portion of incoming MSW increases together with the decrease of the moisture content due to prohibition of directly burying food waste in landfill, the heating value of waste is remarkably increasing in comparison with the early stage of incinerator installation. Consequently, the increased heating value in incinerator operation causes a number of serious problems such as reduction of waste amount to be burned due to the boiler heat capacity together with the significant NO generation in high temperature environment. Therefore, in this study, a series of numerical simulation have been made as parameters of waste amount and the fraction of moisture in air stream in order to investigate optimal operating condition for the resolution of the problems associated with the high heating value of waste mentioned above. In specific, a detailed turbulent reaction flow field calculation with NO model was made for the full scale incinerator of D city. To this end, the injection method of moisturized air as oxidizer was intensively reviewed by the addition of moisture water amount from 10% and 20%. The calculation result, in general, showed that the reduction of maximum flame temperature appears consistently due to the combined effects of the increased specific heat of combustion air and vaporization heat by the addition of water moisture. As a consequence, the generation of NOx concentration was substantially reduced. Further, for the case of 20% moisture amount stream, the afterburner region is quite appropriate in temperature range for the operation of SNCR. This suggests the SNCR facility can be considered for reoperation. which is not in service at all due to the increased heating value of MSW.