• Title/Summary/Keyword: 장치이용현황

Search Result 178, Processing Time 0.033 seconds

GMT FSM Prototype의 개발 현황

  • Kim, Yeong-Su;Go, Ju-Heon;Jeong, In-U;Yang, Ho-Sun;Kim, Ho-Sang;Lee, Gyeong-Don;An, Hyo-Seong;Cho, Myung;Han, In-U;Cheon, Mu-Yeong;Park, Byeong-Gon;Gyeong, Jae-Man;Yun, Yang-No
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.63.1-63.1
    • /
    • 2012
  • 한국천문연구원은 GMT (Giant Magellan Telescope)의 부경 중의 하나인 FSM (Fast Steering Mirror)의 시험모델을 개발 중이다. 구경 1.06m의 반사경을 가공하는 중인데, 뒷면 경량화 가공을 마쳤다. 다음 작업으로 비축 비구면의 앞면을 가공하기 위해 반사경의 지지셀을 제작 중이다. 또한 tip-tilt 제어를 위한 test-bed를 제작하여 스프링과 진공을 이용한 무게 상쇄실험을 마쳤다. 미러 셀을 제작하여 실제 상황과 비슷한 환경에서 시험하고자 한다. 또한 tip-tilt의 최종 성능시험을 위한 장치를 개발하고 있다. 이 발표에서는 FSM 시험모델의 개발 현황에 대해 논한다.

  • PDF

Trends of Technical Regulations on Terminal Equipment for Giga-Class Internet Service (기가 인터넷 서비스 단말장치 기술기준 동향)

  • Choi, M.H.;Cho, P.D.;Lee, S.M.;Park, J.Y.;Kim, H.J.
    • Electronics and Telecommunications Trends
    • /
    • v.31 no.2
    • /
    • pp.63-72
    • /
    • 2016
  • 기가 코리아 실현을 위한 다양한 정부 시책에 따라 우수한 기술이 적용된 새로운 통신서비스 기술의 개발과 함께 네트워크 고도화를 위한 노력이 활발하다. 또한, 오래된 기축 건물에 설치된 낮은 전송 특성의 전화선을 이용하여 기가 급의 전송속도를 갖는 기가 인터넷 기술이 개발되어 상용 서비스를 제공하고 있다. 본고에서는 이러한 기가 인터넷 기술에 대한 국제 표준화 동향과 기술/시장동향을 분석하고, 신뢰성 있는 서비스의 제공과 이용자의 안전을 위한 기가 인터넷 서비스 단말장치의 세부 기술기준의 도입 현황을 알아본다. 최근 국내 통신사업자를 중심으로 다양한 국제 표준이 적용된 기가 인터넷 서비스 기술개발이 완료되거나 완료단계에 있어 향후 전화선 기반의 VDSL 서비스를 대체할 수 있는 서비스로 자리잡을 것으로 것으로 예상된다.

  • PDF

비진공 코팅 방식에 의한 CIGS 박막 태양전지 개발

  • An, Se-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.28-28
    • /
    • 2010
  • 칼코파라이트 구조의CuInSe2 (CIS) 계 화합물은 직접천이형 반도체로서 높은 광흡수 계수($1{\times}10^5\;cm^{-1}$)와 밴드갭 조절의 용이성 및 열적 안정성 등으로 인해 고효율 박막 태양전지용 광흡수층 재료로 많은 관심을 끌고 있다. CIS 계 물질에 속하는 $Cu(InGa)Se_2$ (CIGS) 태양전지의 경우 박막 태양전지 중 세계 최고 효율인 20%를 달성한 바 있다. 그러나 이러한 우수한 성능에도 불구하고 CIS 계 박막 증착시 동시증발장치나 진공 스퍼터링 장치와 같은 고가 진공장비를 사용해야 한다는 점이 CIS 박막 태양전지 상용화의 걸림돌이 되고 있는데, 이는 장비 특성 상공정단가가 높고 대면적화가 어렵기 때문이다. 따라서 기술개발 이후의 상용화 단계를 고려할 때 CIS 박막 제조 공정단가를 획기적으로 낮추면서도 대면적화가 용이한 신공정 개발이 필수적이다. 이러한 관점에서 용액 및 나노 입자 전구체를 비진공 방식으로 코팅하여 CIS 광흡수층을 제조하는 기술이 CIS 태양전지의 저가화 및 대면적화를 가능케 하는 차세대 기술로 인식되고 있다. 본 세미나에서는 다양한 형태의 용액 또는 입자 전구체를 이용한 CIS 광흡수층 제조 기술개발 현황 및 각 기술별 특징을 소개하고자 한다.

  • PDF

기술현황분석 - 전기적 관성모멘트를 이용한 제동장치 성능시험기 소개

  • Jeong, Dong-Su
    • 기계와재료
    • /
    • v.25 no.3
    • /
    • pp.130-136
    • /
    • 2013
  • 철도차량용 제동장치 성능시험기는 제륜자의 마찰계수, 마모량, 열반점 등의 물리적 성질을 실차와 유사한 환경조건에서 시험을 수행함으로써 제륜자의 연구개발 및 성능평가의 목적으로 활용한다. 제륜자는 차량의 운동에너지를 열에너지로 변환한다. 성능시험기는 철도차량의 주행 운동에너지에 해당하는 관성질량으로부터 회전 운동에너지에 해당하는 관성모멘트를 조성하여야 한다. 공용 시험기에서 각종 철도차량에 대한 관성모멘트를 기계적 관성모멘트인 플라이휠로 모의하기에는 용량도 크고 구조가 복합하여 현실적으로 한계가 있다. 본 연구에서는 기계적 관성모멘트의 한계를 극복하고자 전기적 관성모멘트를 부가적으로 활용하는 기법을 제시하고 이를 적용한 시험기를 소개하고자 한다. 이러한 연구는 시험기의 외형적인 크기를 줄이고 또한 각종 철도차량에서 요구하는 정량적인 관성질량의 모의가 가능하리라고 사료된다.

  • PDF

문자인식에 관한 연구

  • Lee, Gwang-Ro;Jeong, Hui-Seong;Kim, Myeong-Won
    • Electronics and Telecommunications Trends
    • /
    • v.4 no.2
    • /
    • pp.124-142
    • /
    • 1989
  • 인간의 정보교환이나 기록의 매체로써 인간사회에서 중요한 문자는 시간이 경과함에따라 사용량이 비약적으로 증가해 왔으며, 앞으로도 증가 추세는 더욱 가증될 전망이다. 이러한 계속적인 정보의 증가는 활자를 매체로 하는 수용 한계를 넘어, 이미 computer를 활용하지 않으면 안되게 되었다. 특히, 기존의 문서화 되어있는 필요한 많은 data와 나날이 늘어나는 정보의 양을 database화 하여, 원하는 정보를 신속히 찾아내기 위해서는 기존의 key board를 이용하여 사람의 손으로 입력하는 방법보다 신속하고 정확한 입력장치개발이 요구된다. 이러한 data입력장치의 개발이 선행되지 않는다면 computer의 정보처리 속도와 연산속도가 아무리 향상되어도 효율적인 정보처리를 이룩할 수 없을것이다. 그러므로 이러한 것을 실현하기 위해서는 먼저 문자의 인식이 필요불가결하다. 본 논문에서는 문자인식의 현황과 문제점을 제시함으로써 효율적이고 경제적인 문자인식 sysyem 구축에 도움이 되기 바라며 이하 OCR(Optical Character Recognition)의 역사와 발전, 문자인식 방법과 문자인식 system의 구성, On-line 문자인식과 Off-line 문자인식에 관하여 논하고 결론을 맺는다.

Technology Trends of Indoor Air quality for Public transportation (대중교통 실내공기질 기술 동향)

  • Park, Mijeong;Choi, Jinsik;Park, Byung Hyun
    • Prospectives of Industrial Chemistry
    • /
    • v.23 no.4
    • /
    • pp.13-19
    • /
    • 2020
  • 수년간 고농도 미세먼지 발생으로 인한 실내공기질 관리방안에 관한 논의가 계속되고 있다. 특히, 시민들이 하루에 1.75시간 이상 지하철 및 버스 등의 대중교통 내에서 머물고 있는 것으로 발표되고 있어 환경부에서는 2019년 대중교통에서의 공기질 관리 방안을 강화하는 것으로 발표한 바 있다. 최근 철도차량 등의 대중교통 차량에서 공기질 개선장치가 도입되고 있는 추세이긴 하나, 대부분의 기존 대중교통차량에서는 공기질 개선장치가 적용되어 있지 않고 대기질이 나쁨인 경우 실내 환기가 어려워 이용 시민들의 건강을 해칠 수 있는 상황이다. 이러한 상황에서 강화되는 실내공기질관리법을 만족하기 위해서는 다양한 대중교통 차량에서의 공기질 관리기술을 토대로 신규차량 뿐만 아니라 기존차량에서 적용할 수 있는 실제적인 논의가 필요하다. 본 기고문에서는 대중교통에서의 공기질 현황을 알아보고 효율적인 공기질개선을 위한 미세먼지 및 이산화탄소 저감에 관한 연구동향을 정리하고자 한다.

Research on the Actual Condition of the radiation Safety Management(RSM) for the Educated Training of the Dental Diagnostics X-ray Generators (교육용 치과 엑스선 발생장치에 대한 방사선 안전 관리 실태 조사)

  • Lee, Mihyeon;Yu, Yunsik;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.467-477
    • /
    • 2014
  • The purpose of this study is to offer data base for establishment of dental training x-ray generator based safety usage through surveying real radiation safety management state of radiation worker's in plan of operations that have dental training x-ray generators and use it. For it, comprehensive references were surveyed referring reports of current state of regulation technique development and domestic radiation safety evaluation and nuclear related legislation regarding radiation safety management of dental training x-ray generators. On the basis of it, questionnaires were filled in about respondent's general characteristic radiation safety manager's status current state of radiation safety management and the level of knowledge & consciousness. For the study, the survey was conducted to 224 people of radiation safety managers and university graduates training assistants and full-time professors who can treat dental training x-ray generators in education center. through this survey 95 questionnaires were used as analysis materials except the insufficient and omitted responses. As a method of analysis, the frequency and percentage were figured out with the general characteristics and safety manager's status. Chi-square test for frequency and correlation per question analysis and Pearson correlation analysis for crosslevel correlation were done with current state of radiation safety management and knowledge & consciousness level. As a result, running dental training x-ray generators was dealt with by 20's to 40's who have high education level over post undergraduate degree and major in dental hygienic. In addition, female have higher consciousness level for radiation safety management than male. It shows significal linear relation statistically(${\chi}^2$ >5, 0.1${\chi}^2$ >5, 0.3${\chi}^2$ >5, 0.3

A Study for Adopting the Temperature Control Unit on Memory Device Tester Based on Principle of Thermoelectric Semiconductor (열전소자 원리를 이용한 부품 Tester용 온도공급 장치 연구 (메모리 Device Tester용 온도제어장치 도입을 위한 연구))

  • Kim, Sun-Ju;Hong, Chul-Ho;Shin, Dong-Uk;Seo, Seong-Bum;Lee, Moo-Jea
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.414-416
    • /
    • 2003
  • As environmental conditions for memory products are increasingly high speed/high density, adopting diverse system configuration, it's more and more difficult for current component tester to adopt the actual condition of field application. If system test screening is realized in component level, test coverage failure can be made more secured in the initial stage, evaluation cost can be reduced and the effectiveness of investment for the facility can be maximized. Based on the above background, component automatic system tester was developed and showed off satisfactory results per each memory device family. In this paper, component quality stabilization strategy and cost saving for tester investment through future Quality monitoring and application to mass production will be presented.

  • PDF

The Status and prospect of Pohang Synchrotron Light Source at PAL on its 25th Anniversary

  • Jo, Mu-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.61.2-61.2
    • /
    • 2013
  • 우리나라 최초의 거대과학 장치인 포항방사광가속기(PLS)는 지난 16년(1994~2010) 동안 국내외 이용자에게 제3세대 방사광을 제공했다. 최초 2기의 빔라인을 시작으로 꾸준하게 빔라인 증설과 성능개선을 위해 노력해 왔다. 지속해서 늘어나는 방사광 이용자 수와 더욱더 좋은 수준의 방사광 요구에 부응하기 위하여 2009년부터 3년 동안 가속장치의 성능향상사업(PLS-II)을 마쳤다. PLS-II는 PLS 대비에너지와 빔전류는 3 GeV, 400 mA로 늘리는 반면 빔의 크기는 크게 줄이고 빔안정성을 개선한 고품질 X-선 방사광 발생장치이다. 2012년부터 16기의 삽입장치 빔라인을 포함한 30기의 빔라인을 가동하여 이용자 지원을 하고 있으며 초전도케비티 설치를 포함한 목표 성능의 확보에도 많은 노력을 기울이고 있다. 현재는 6 nm-rad의 빔에 미턴스, 3-GeV전자빔, 약 0.5 ${\mu}m-rms$ 빔안정도를 가진 200 mA Top-up 운전으로 빔을 제공 하고 있으며 2014년 말에는 저장전류 400 mA급의 PLS-II 목표치로 운전할 계획이다. 본 발표에서는 포항가속기의 25년 역사를 돌아보고 가속장치의 건설에 얽힌 이야기, 중요장치 그리고 운전과 빔제공에 관한 내용, 특히 핵심 운전가치인 빔안정성을 개선하고 유지하기 위한 노력을 빔운전 측면과 진공을 포함한 엔지지어링 측면에서 언급하고자 한다. PLS 건설부터 현재 운용 중인 30기의 빔라인에서 수행된 연구 성과의 통계에 대하여 훑어보고 X-선 산란과 광전자분광을 이용한 구조, 성분 및 물성분석, 그리고 이미징 등의 분야에서 나온 탁월한 연구 결과를 살펴본다. 앞으로 건설될 신규 빔라인과 빔라인의 향후 운영 방향을 소개한다. 마지막으로 지금 포항가속기연구소에서 건설 중인 제4세대 가속기(X-선 자유전자레이저) 프로젝트의 개요 및 건설 현황과 함께 앞으로 기대되는 새로운 과학에 대하여도 소개하고자 한다.

  • PDF

An ability test for the use of indirect radiographic unit (간접촬영용 X-선 발생장치 성능 평가)

  • Im, In-Cheol
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.37-41
    • /
    • 2004
  • Purpose : Raise ability cultivation in presence at a sicked business by performance management estimation of device through measurement. Also Learn a technology that measure exact tube voltage, exposure time, output dose. And it is to grasp photofluorography X-ray generator existing circumstances using at hospital. Material & Method : Investigated Photofluorography X-ray generator(inside, outside each 10) of 10 university hospitals using tube voltage, exposure time, output dose measuring instrument. Result : Photofluorography device that tube voltage correctness is incongruent by examination PAE decision came out 3, and at exposure time correctness examination 2 incongruent, Also 3 that calculate coefficient of variation about exposure in repeatability examination of exposure were incongruent. Inappropriate photofluorography device is 5 outside hospital(mobile unit) and the thing in hospital was 3 in 3 kind of efficiency test. It appeared high that photofluorography device outside hospital is more incongruent than thing in hospital. Conclusion : May ready situation that can offer patient medical service of good quality by radiation exposure reduction, image quality administration, retake decrease etc. by keeping performance of Photofluorography device. Therefore, is considered that need on-time efficiency test.

  • PDF