• Title/Summary/Keyword: 장비성능 평가

Search Result 747, Processing Time 0.026 seconds

Simulation model for performance estimation of transport vehicle on automated container terminal (자동화 컨테이너 터미널의 이송장비 운영평가를 위한 시뮬레이션 모델)

  • 하태영;최용석;김우선
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.443-449
    • /
    • 2004
  • In this paper, we established a simulation model for transport vehicle that carries the container transportation between apron and yard block on automated container terminal with a perpendicular yard layout. Usually, the efficiency of container terminal is evaluated by productivity of container cranes at apron, and though there are enough support of transport vehicles and yard cranes, can improve the productivity of container cranes. Especially, transport vehicle is very important factor in productivity of container cranes and has variable work productivity according to loading and unloading situation of container cranes. Therefore, a method that can estimate work productivity of transport vehicle efficiently is required. We analyzed work productivity of transport vehicle using simulation model that has state transition of transport vehicle. We performed various simulation experiment and analyzed work productivity of transport vehicle and calculated the required number of transport vehicle by container crane additionally.

  • PDF

Plasma Processing Supervision Using Varing CUSUM Control Chart (가변 CUSUM 제어차트를 이용한 플라즈마 공정 감시 )

  • Kim, U-Seok;Kim, Byeong-Hwan
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.169-170
    • /
    • 2007
  • 본 연구에서 반도체 플라즈마 장비 감시를 위한 CUSUM 제어 차트 설계기법에 관해 연구하였다. CUSUM 제어차트에 관여하는 설계변수의 다양한 조합에 대하여 플라즈마 장비의 감시 성능을 평가하였다. 평가를 위해 RF 정합망 감시시스템을 이용하여 플라즈마 임피이던스 정합에 관여하는 정합변수에 대한 실시간 데이터를 수집하였으며, 여기에는 임피이던스와 상위치에 대한 전기적 정보, 그리고 반사전력에 대한 정보가 포함된다. CUSUM 설계변수에 따른 감시와 진단성능을 평가하였으며, 최적화된 설계변수의 결정으로 감시와 진단성능을 증진시킬 수 있었다. 한편, 고정설계변수에 비해 가변 설계변수가 감시성능을 증진하느데 더 효과적임을 알 수 있었다. 평가에 이용된 데이터는 소스전력이 500 W, 압력이 15 mTorr, $O_2$ 유량이 75 socm일 때 수집하였다.

  • PDF

Performance Evaluation of Road Stripe Removing Equipment Using High Pressure Water-Jet (워터젯을 이용한 노면표시 제거장비의 성능평가에 관한 연구)

  • Han, Jae-Goo;Kwon, Soon-Wook;Kim, Kyoon-Tai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.6
    • /
    • pp.79-89
    • /
    • 2006
  • Current removing process is labor intensive and time consuming, employing a conventional grinding type manual machine. From a social and economic point of views, these kinds of manual tasks bring about social inconvenience and economic loss including traffic jam and high labor costs. The objective of the study was to develop and evaluate a road stripe removal equipment using water jet technology. The following shows the results. First, It was analyzed that the obtainable productivity from the equipment developed in the study is 280% compared to the current equipment. In this study, it was also calculated the Benefit/Cost Ratio and the result showed that the ratio is 3.28, so it is expected that the equipment can produce great benefits for the relevant companies. Second, an analysis was also conducted on the traffic congestion cost, and the equipment could save about \2,550 million per day compared to the conventional equipment. Therefore, it is analyzed that the economic viability of the equipment is sufficient.

진공 공정장비부품의 평가 연구

  • Song, Je-Beom;Sin, Jae-Su;Gang, Sang-U;Kim, Jin-Tae;Sin, Yong-Hyeon;Yun, Ju-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.33-33
    • /
    • 2011
  • 반도체 산업기술이 발달함에 따라 고청정 공정 환경이 요구되고 있으며, 반도체 공정용 장비에 이용되는 부품 중 양극산화피막법(Anodizing)으로 피막을 성장시킨 anodic aluminum oxide (AAO)부품은 플라즈마에 의해 화학적, 물리적 침식이 발생하여 코팅막과 모재에 손상을 일으키며 코팅막이 깨지거나 박리되면서 다량의 Particle이 생성됨으로써 공정상의 여러 가지 문제를 야기 시킨다고 알려져 있다. 하지만 코팅막을 평가하는 방법은 거의 전무하며 기본물성 측정방법인 피막두께, 내전압, 임피던스, 내식성 측정방법을 통하여 여러 기본물성측정방법으로 부품의 평가기술을 연구하였다. 본 연구에서는 이러한 진공 부품의 하나인 anodic aluminum oxide (AAO)부품샘플을 누설전류 및 내전압 측정하여 샘플의 전기적 특성을 측정하였고, 표면 미세구조의 변화를 관찰하였다. 부식실험으로는 HCl 가스를 발생시켜 부식정도를 알아봤으며, 부식처리와 플라즈마 처리 모두 코팅 막의 손상과 전기적 특성의 감소를 보였다. 진공장비 전극 부품평가의 유익한 평가 항목으로서 플라즈마 데미지를 주는 도중에 실시간으로 부품평가에 따른 Particle을 측정함으로써 ISPM 장비를 이용하여 진공 장비용 코팅부품이 플라즈마공정에서 발생하는 오염입자를 측정할 수 있는 방법을 연구하였다. 이러한 결과를 이용하여 진공공정에서 사용되는 코팅부품이 플라즈마에 의한 손상정도를 정량화 하고 평가방법을 개발하여 진공장비용 공정 중 실시간으로 부품의 성능평가가 가능하고 코팅부품 신뢰성 향상이 가능할 것으로 본다.

  • PDF

Establishment of Standard of Property Control for Angiographic Equipments (혈관조영장비의 성능관리 기준개발)

  • 임현수;김부길
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.6
    • /
    • pp.61-66
    • /
    • 2004
  • To make a guide line of property control of angiography equipments, we made standard evaluation sheet forms of facility and management of angiography suite, physical properties of angiography equipments, and image quality of film and then surveyed them at 29 hospital nationwide. Survey and development of standard evaluation sheet form of physical properties of angiography equipments. By using resolution & radiation dose, physical properties of angiography equipments of 49 in number nationwide were evaluated. Most of them (91%) had good performance.

Development of an Performance Evaluation Method for Vehicle Detector Speed Measurement Applying Uncertainty in Measurement (측정불확도를 적용한 차량검지기 속도측정 성능평가방법 개발)

  • Lee, Hwan-Pil;Kim, Yong-Man;Kang, Dong-Yun
    • International Journal of Highway Engineering
    • /
    • v.14 no.2
    • /
    • pp.165-174
    • /
    • 2012
  • In this study, a method for evaluating the performance of speed measurements was developed to assess the qualities of a vehicle detector. The evaluation method considers measurement errors that are reflected in a reference speed. For this, the concept of uncertainty in measurement was applied to the development method. Other factors such as precedent study, statistical processing techniques, and speed measurement performance method of traffic enforcement equipment and vehicle detection systems were also reviewed. Through this process, the problems of the existing evaluation methods were derived and developed for the new performance evaluation method. Vehicle detectors that are installed in the field were evaluated using the traditional assessment methods and the developed method. As a result, for traditional assessment methods, it was found that evaluation criteria are acceptable, while developed method's criteria are not acceptable. This means that traditional assessment methods do not sufficiently consider errors in measurement, so it has potential to over-estimate for performance of evaluation equipment. On the other hand, it was represented that the developed method should include variable factor such as errors in measurement and more precise compared to traditional assessment methods.

Control Techniques Micro-Vibration for Sensitive Mechanical Equipment (정밀기기의 미진동 제어기술)

  • 이홍기;이규섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.175-181
    • /
    • 1991
  • 정밀장비의 진동환경을 평가, 제어하기 위해서는 우선적으로 미진동 환경을 측정할 수 있는 장비와 기술이 필요하며, 방진 system 구성시 국내에서는 방진소재의 개발이 요구되고 있다. 그리고 진동에 민감한 정밀장비들을 사용 하는 반도체 및 정밀공장에서는 진동허용 기준을 나타내는 data sheet가 필 요하고 사용자측에서도 장비의 진동 test성적서를 장비구매시 제작사에 요구 할 필요성이 있다. TEM(투과형 전자현미경)의 경우 음압에 의한 가진문제도 대두되고 있으며 정밀장비가 최대의 성능을 발휘하기 위해서는 이러한 문제 를 검토해야 한다. 만일 국내에서 진동에 민감한 정밀장비를 제작시 장비의 진동 특성을 평가할 수 있는 실험장치와 기술이 필요하다.

  • PDF

Performance Testing of Medical US Equipment Using US Phantom(ATS-539) (Focusing on Daegu Region) (초음파팬텀(ATS-539)을 이용한 의료용 초음파장비의 성능검사(대구지역을 중심으로))

  • Kim, Do-Hyung;Kwon, Deok-Moon
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.295-305
    • /
    • 2014
  • This study is to provide accurate information as medical imaging equipment to check for the presence of body disease US equipment. We investigated the status of medical US equipment performance in Daegu and criteria US phantom (ATS-539) for US equipment performance measurements. The results in this study, 1. US phantom measurement results: The test passed rate were 88.6% and the failed rate were 11.4%. 2. The difference between the group of mean and the pass/failed groups were statistically significant. Focal zone and 4 mm functional resolution in the two items that are not present the passing standard. 3. The difference was statistically significant number of years and used equipment and pass the failed equipment (4.13 vs 7.25 years). We investigated the performance status of US equipment used in the clinical area in Daegu. The basis for the two items are not present this proposed passing standard. Equipment performance was associated with the number of years of using US equipment. It is necessary to maintain the best performance of the equipment phantom measurements for performance testing of US equipment.

Usefulness of Non-Invasive Measurement Tool on Performance Evaluation of Inverter Type X-ray Unit (인버터식 X선장치의 성능평가 시 비접속형 측정기의 유용성)

  • Kang, Se-Sik;Kim, Chang-Soo;Ko, Sung-Jin
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.123-127
    • /
    • 2008
  • Purpose: As the demand of a simple and precise method increases to evaluate the performance of the inverter type x-ray unit, we evaluated the usefulness of the recently-introduced X-ray Multi-Function Test Device (moldel : Xi (unfors)-prestige). Method: We compared the performance of X-ray Multi-Function Test Device (XMFTD) which is non-inveasive type device with the performance of Dynalyzer III that has been most widely used inveasive type measure device. Result: X-ray output dose was increased a little in the XMFTD, but both devices were below the performance evaluation standard, 0.002 in the output reproducibility. Linearity of XMFTD were below 0.1 which means that Dynalyzer III showed more excellency in linearity. As the the accuracy of exposure factor, 1.8 and 2 tube voltage, 2.01 and 2.3 tube current were measured. The exposure time was also measured by 0.01 sec ${\pm}10%$. Both devices were within the acceptance of performance evaluatioin standard. Conclusion: We proved the usefulness of X-ray Multi-Function Test Device (model: Xi (unfors)-prestige) to evaluated the performance on reproductibility and linearity of X-ray output and accuracy of exposure factor of inverter type unit.

  • PDF

Implementation of the Platform for Performance Evaluation of Fingerprint Recognition System (지문 인식 시스템 성능 평가를 위한 플랫폼 구현)

  • 문지현;안도성;김학일
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2001.04b
    • /
    • pp.601-603
    • /
    • 2001
  • 지문 인식을 이용한 인증 시스템의 개발에는 장비와 알고리즘의 개발이 선행되어야 하며, 목표로 하는 대상 사용자들의 요구를 만족시키기 위한 시스템의 성능 평가에 많은 노력을 기울여야 한다. 본 연구는 지문 인식을 이용한 개인인증 시스템의 개발 및 평가에 있어 필요한 성능 평가 플랫폼을 구현하고, 기 보유한 알고리즘을 바탕으로 한 실험결과를 해외의 테스트 플랫폼의 그것과 비교함으로써 평가의 신빙성을 확보함과 동시에, 개발에 드는 금전적, 시간적 비용을 줄여 최적의 시스템 개발 방향을 제시할 수 있도록 하였다.

  • PDF