• Title/Summary/Keyword: 장비비

Search Result 2,438, Processing Time 0.03 seconds

A Study on the Buckling Strength and Effective Length of Tubular Member with Gusset Plate Considering End Restraints (단부구속효과를 고려한 관통 가셋트 부착 강관부재의 좌굴내력 및 유효세장비 산정에 관한 연구)

  • Kim, Woo Bum
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.2
    • /
    • pp.159-165
    • /
    • 2003
  • A tubular member with through-gusset plate is often used to transmit axial compression in an electric transmission towers. In current code, the strength of tubular member is evaluated with an effective length factor k=0.9 without considering the deformation of boundary element. A buckling strength of member with end gusset plate is affected by stiffness ratio($\beta$) and the length ratio(G) between main tubular member and end gusset plate. In this study theoretical mechanism based on the elastic buckling behavior was investigated, and finite element analysis was performed to propose a formula for the buckling strength and effective length factor of tubular member in elsatic and inelastic ranges.

항공 야시장비체계의 필요성과 적용실례

  • Lee, Dae-Yeol;Gwon, Jong-Gwang
    • Defense and Technology
    • /
    • no.9 s.247
    • /
    • pp.74-79
    • /
    • 1999
  • 과거는 항공기의 야간임무 수행시 항법장비와 계기에 의존하여 작전을 수행하였다. 이것은 조종사로 하여금 비행 안정감을 주지 못하여 심리적 작전 저해요소로 작용하였다. 따라서, 야간 비행시에도 낮과 유사한 비행조건을 만들어주는 장비 즉, 야시장비체계 개발이 본격화 되었다. 야시장비가 장착된 항공기를 탑승하기 위해서는 야간 투시경(NVG)이 필요하며 항공기 내, 외부 조명의 개조가 전제되어야 한다. 이 글에서는 항공기 야시장비체계 개조의 필요성과 적용실례를 들어 야시장비체계에 대하여 소개하고자 한다.

  • PDF

Feasibility Study on Diagnosis of Material Damage Using Bulk Wave Mixing Technique (체적파 혼합기법을 이용한 재료 손상 진단 적용 가능성 연구)

  • Choi, Jeongseok;Cho, Younho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.1
    • /
    • pp.53-59
    • /
    • 2016
  • Ultrasonic nonlinear evaluation is generally utilized for detection of not only defects but also microdamage such as corrosion and plastic deformation. Nonlinearity is determined by the amplitude ratio of primary wave second harmonic wave, and the results of its comparison are used for evaluation. Owing to the experimental features, the experimental nonlinearity result contains system nonlinearity and material nonlinearity. System nonlinearity is that which is unwanted by the user; hence, it acts as an error and interrupts analysis. In this study, a bulk wave mixing technique is implemented in order to minimize the system nonlinearity and obtain the reliable analysis results. The biggest advantage of this technique is that experimental nonlinearity contains less system nonlinearity than that for the conventional nonlinear ultrasonic technique. Theoretical and experimental verifications are performed in this study. By comparing the results of the bulk wave mixing technique with those of the conventional technique, the strengths, weaknesses, and application validity of the bulk wave mixing technique are determined.

An Experimental Study on the Trenchless Construction Method For Small Diameter Cable Conduits (소구경 비개착 관로건설 기술연구)

  • Seo, Dong-Seob
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2005.08a
    • /
    • pp.217-221
    • /
    • 2005
  • 도시의 기능이 날로 커져가고 땅속 지하매설물은 포화상태에 이르렀다. 또한 시민들의 의식 수준이 높아가면서 도시에서의 굴착시공은 민원유발과 교통소통장애 문제로 날로 어려워지고 있는 것이 현실이다. KT에서는 무인 및 유인 통신구를 건설할 수 있는 장비를 이미 개발한바 있으며, 본 연구를 통해 도심지에서 보다 효율적으로 통신관로 ${\Phi}50mm,\;{\Phi}150mm,\;{\Phi}300mm$를 시공할 수 있는 장비를 개발하게 되었다. 도시는 복잡하기 때문에 비개착 시공에 있어서 시공 점용면적이 상대적으로 많을 경우 어려움을 겪게된다. 소구경 비개착 장비인 XS-300은 길이 1.45m 폭 0.8m 높이 0.97m 이며 중량은 700kg인 소형장비인 것이 특징이다. XS-300은 도심지에서 통신맨홀 터파기 부분을 압입구로 활용할 수 있으며 경제적인 비용으로 개착식 시공이 불가한 구간에 대한 인입관로 구성과 지하장애물 하월시공, 도로횡단 시공 시에 적합한 장비이다. 특히 타 시설물을 관통한 불량통신시설과 재해에 취약한 통신시설에 대해 안전하고 경제적인 비용으로 이설시공을 할 수 있으며 통신인프라 기초시설 안정화 및 품질고도화에 기여할 수 있을 것이다.

  • PDF

Normal MR Spectroscopic Findings of the Cerebellum and Pons: Comparison of the Results between Intra-Unit and Inter-Unit Studies (소뇌와 뇌교의 정상 자기공명분광 소견: 같은 장비내 및 다른 장비간의 결과 비교)

  • 최준일;장기현;송인찬;도강현;이준우
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.2
    • /
    • pp.123-129
    • /
    • 2001
  • Purpose: The purposes of this study are to evaluate normal MR spectroscopy (MRS) data of the cerebellum and pons, and to evaluate intra-unit and inter-unit differences of the results. Materials and methods: Nine normal volunteers (mean age 23 years) were studied with two 1.5 Tesla MR units (A and B units). A total of four sessions of MRS study were performed with two sessions in ea.ch MR unit in each volunteer. In each session, MRS data were obtained from bilateral cerebellar hemisphere and pons. MRS was performed using spin-echo single voxel technique with repetition time of 2000 ms, echo time of 288ms and 128 averagings. Voxel size was $2{\;}{\times}{\;}2{\;}{\times}{\;}1.5{\;}cm$ in the cerebellum and $1.5{\;}{\times}{\;}1.5{\;}{\times}{\;}1.5{\;}cm$ in the pons. Metabolite ratios of NAA/Cho, NAAcCr, NAAc(Cho+Cr) and Cr/Cho (both peak heights and the peak areas) were compared among the results of four sessions of MRS for evaluation of intra-unit and inter-unit differences. Results: In the cerebellum, mean (SO values of peak height NAA/Cho, NAA/Cr, NAA/(Cho+Cr) and Cr/Cho ratios obtained in the first session of A unit were $1.08{\pm}O.16,{\;}1.44{\pm}O.286,{\;}0.61{\pm}O.09{\;}and{\;}O.76{\pm}0.13$, respectively. Comparing with the results of the second session, intra-unit differences were 3-7%. In B unit intra-unit differences were 1-9%, except for 22% of Cr/Cho ratio. Inter-unit differences between A and B units were 1-26%. In the pons, mean ISD values of peak height NANCho, NANCr, NANICho + Cr) and Cr/Cho ratios obtained in the first session of A unit were $1.51{\pm}O.35,{\;}3.35{\pm}O.78,{\;}1.02{\pm}0.16{\;}and{\;}0.47{\pm}O.14$, respectively. Mean NAAfCho, NANCr and NAAI(Cho+ Cr} ratios of the pons were significantly higher than those of the cerebellum. Intra-unit differences were 2-21 % in A unit and 4-18 % in B unit. Inter-unit differences between A and B units were 1-18%. The mean values obtained by using peak area were generally higher and wider in range than those of peak height in both units. Conclusion: Mean NAAfCho, NAAlCr and NAAf(Cho+Cr) ratios of the cerebellum were significanHy lower than those of the pons. Intra-unit differences of most metabolites ratios were generally not significant, whereas inter-unit differences were greater than intra-unit differences in more metabolite ratios. Therefore, normal MRS data of the cerebellum and the pons should be obtained in every MR unit, before MRS applications in the diseases of the cerebellum and the pons.

  • PDF

Equipment Management System based on Wire and Wireless Internet (유무선 인터넷 기반 장비관리시스템)

  • 박상국;문상호
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2003.05b
    • /
    • pp.663-666
    • /
    • 2003
  • 기근의 산업현장에서는 장리관리 자가 장비의 모니터링과 제어를 위하여 항상 대기하고 있어야 하므로, 인력 낭비와 시간 손실이 많으므로 비효율적이다. 본 논문에서는 이러한 문제점을 해결하기 위하여 유무선 인터넷을 기반으로 하는 실시간 장비관리시스템을 개발한다. 이 시스템에서는 장비에 이상 발생시 고장을 자동으로 감지하여 장비관리자의 휴대폰으로 통보하고, 관리자가 유무선 인터넷을 통하여 고장 장비에 대한 응급조치를 한다. 이를 위하여 세부적으로 로컬 장비 제어시스템, 장비관리시스템, 모바일 시스템, 웹 시스템을 각각 개발한다.

  • PDF

Application of Resistivity Seismic Flat Dilatometer (RSDMT) System for Multiple Evaluation of the Soft Soil Site (연약지반의 복합적 평가를 위한 전기비저항 탄성파 Flat DMT 장비 적용)

  • Bang, Eun-Seok;Kim, Young-Sang;Park, Sam-Gyu;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.12
    • /
    • pp.111-122
    • /
    • 2012
  • Resistivity seismic dilatometer (RSDMT) system is introduced. The resistivity module for obtaining resistivity-depth plot and seismic module for obtaining wave velocity-depth plot are attached to the conventional flat dilatometer testing equipment. To enhance the reliability and repeatability of seismic part in RSDMT, automatic testing system including automatic surface source, PC based data acquisition system and operating program was constructed. To obtain real resistivity value of soil, geometric factor for the array of electrodes in RSDMT was derived empirically. The verification studies for the developed RSDMT system were performed with SPT, CPTu, bender element test and DC resistivity survey. Through one penetration of RSDMT, various soil parameters were obtained and the reliability and repeatability of developed RSDMT system could be checked.

비접촉 3차원 검사장비의 기술동향 및 시장동향

  • 유인상
    • The Optical Journal
    • /
    • v.14 no.4 s.80
    • /
    • pp.56-58
    • /
    • 2002
  • 최근들어 FPD(평판 디스플레이), MEMS, 반도체, 광부품 등의 분야에서 극미세화의 경향이 보이고 있다. 이들의 가공기술과 더불어 검사장비 역시 2차원 마이크로미터의 수준에서 3차원 나노미터 정밀도를 갖는 장비로 급속도로 교체되고 있는 것이 현실이다. 본 고에서는 반도체에 이어 한국의 기술력을 세계 1위로 끌어올린 FPD 분야에서 3차원 검사장비의 활용을 중심적으로 기술 및 시장동향을 살펴보고자 한다.

  • PDF

Overview of Korean Broadcasting Equipment Market (방송장비산업의 현황 및 전망)

  • Kim, S.M.;Park, K.M.;Koh, S.J.
    • Electronics and Telecommunications Trends
    • /
    • v.26 no.3
    • /
    • pp.111-121
    • /
    • 2011
  • 급변하는 디지털방송 시장 환경과 향상된 국내 디지털방송 기술을 고려할 때, 국내 방송장비산업을 육성할 수 있는 좋은 기회들이 다가오고 있으나 실효성 높은 방송장비 육성정책을 마련하기 위한 체계적인 연구가 제대로 마련되어 있지 않은 상황이다. 본 연구는 이러한 방송장비산업에 대한 체계적인 연구를 위한 첫 걸음으로 방송장비산업의 범위를 정하고 분류체계를 구성하였으며, 이를 기반으로 방송장비 보유 현황 및 국산화율을 파악하였다. 방송장비는 170여 개의 다양한 품목을 4대 분류, 23개의 중분류로 나누었다. 이들 장비 중 영상장비들의 보유비중 및 보유대수는 높으나 국산장비 이용률은 매우 낮은 것으로 나타났다. 품목별로는 호환성, 예산규모, 장비대당 가격, 핵심장비의 기준에서 중요한 품목들이 제조사들의 주요 생산장비에는 속하지 않는 것으로 나타났다. 시장규모 추정 결과, 그간 별로 논의되지 않았던 비방송사의 방송장비 투자규모와 수입규모가 매우 큰 것으로 추정되었다.

  • PDF

Design of a Torque Application Device in Test Rig for a Wind Turbine Gearbox (풍력발전기용 증속기 시험 장비의 토크 인가 장치 설계)

  • Kim, Jeong-Gil;Park, Young-Jun;Lee, Geun-Ho;Nam, Yong-Yun;Oh, Joo-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.5
    • /
    • pp.507-515
    • /
    • 2015
  • This study was conducted to develop and verify a torque application device for use in a mechanical power-circulation test rig for 5.5 MW wind turbine gearboxes. The design and analysis of the torque application device was conducted. In addition, the torsional stiffness of the test rig was calculated using the rotational angle measurements for each of the components. The calculated stiffness of the test rig was $231.13kN{\cdot}m/rad$ for a clockwise torque application. The rated torque can be applied when the stiffness of the gearbox is greater than $1,064,400kN{\cdot}m/rad$ for a clockwise torque application. Because of the limited rotational angle of the test rig, the potential application of the rated torque is determined according to the torsional stiffness of the test gearbox.