• Title/Summary/Keyword: 잡음 제거 여과

Search Result 10, Processing Time 0.027 seconds

Evaluation of Restoration Schemes for Bi-Level Digital Image Degraded by Impulse Noise (임펄스 잡음에 의해 훼손된 이진 디지탈 서류 영상의 복구 방법들의 비교 평가)

  • Shin Hyun-Kyung;Shin Joong-Sang
    • The KIPS Transactions:PartB
    • /
    • v.13B no.4 s.107
    • /
    • pp.369-376
    • /
    • 2006
  • The degradation and its inverse modeling can achieve restoration of corrupted image, caused by scaled digitization and electronic transmission. De-speckle process on the noisy document(or SAR) images is one of the basic examples. Non-linearity of the speckle noise model may hinder the inverse process. In this paper, our study is focused on investigation of the restoration methods for bi-level document image degraded by the impulse noise model. Our study shows that, on bi-level document images, the weighted-median filter and the Lee filter methods are very effective among other spatial filtering methods, but wavelet filter method is ineffective in aspect of processing speed: approximately 100 times slower. Optimal values of the weight to be used in the weighted median filter are investigated and presented in this paper.

Reducing Noise Using Degree of Scattering in Collaborative Filtering System (협력적 여과 시스템에서 산포도를 이용한 잡음 감소)

  • Ko, Su-Jeong
    • The KIPS Transactions:PartB
    • /
    • v.14B no.7
    • /
    • pp.549-558
    • /
    • 2007
  • Collaborative filtering systems have problems when users rate items and the rated results depend on their feelings, as there is a possibility that the results include noise. The method proposed in this paper optimizes the matrix by excluding irrelevant ratings as information for recommendations from a user-item matrix using dispersion. It reduces the noise that results from predicting preferences based on original user ratings by inflecting the information for items and users on the matrix. The method excludes the ratings values of the utmost limits using a percentile to supply the defects of coefficient of variance and composes a weighted user-item matrix by combining the user coefficient of variance with the median of ratings for items. Finally, the preferences of the active user are predicted based on the weighted matrix. A large database of user ratings for movies from the MovieLens recommender system is used, and the performance is evaluated. The proposed method is shown to outperform earlier methods significantly.

Elevation Mask와 CNR Mask가 GPS 보정정보에 미치는 영향 분석

  • Kim, Yeong-Gi;Jang, Won-Seok;Seo, Gi-Yeol
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2012.06a
    • /
    • pp.76-77
    • /
    • 2012
  • GPS 보정정보를 방송하는 우리나라의 DGPS 기준국에서는 IALA의 권고와 같이 $5^{\circ}{\sim}10^{\circ}$의 Elevation Mask를 사용한다. Elevation Mask는 GPS 수신기의 안테나를 기준으로 일정 앙각 이하의 고도에 위치한 위성의 신호를 여과하는 방법으로, 잡음이 많아 정확도가 낮은 위성신호를 측위에 사용하지 않기 위한 방법이다. 또한, CNR Mask는 신호대 잡음비가 작은 신호를 직접 제거하여 측위정확도를 향상시키는 방법이다. GPS 보정정보를 생산하는 DGPS 기준국에서 이들 Mask를 사용하는 것은 보정정보의 생산량에 영향을 미치고, 사용자 측위정확도에 각각 영향을 미친다. 본 연구에서는 Elevation Mask와 CNR Mask의 변화에 따른 잡음의 변화와 이를 기반으로 생성된 보정정보를 적용한 사용자 측위정확도의 변화를 살펴봄으로써, DGPS 기준국에서의 Elevation Mask와 CNR Mask 사용이 보정정보 사용자에게 어떤 영향을 미치는지를 살펴보고자 한다.

  • PDF

Noise Reduction Methods for the EMG Median Frequency Data in Fatiguing Isotonic Exercise (등장성 운동 시 근전도 중앙주파수 데이터의 잡음 제거 방법)

  • Cho, Sang-Hyun
    • Physical Therapy Korea
    • /
    • v.8 no.4
    • /
    • pp.31-43
    • /
    • 2001
  • 19명의 건강한 성인 남자의 우세팔쪽 위팔두갈래근에서 피로가 생길 때까지 2.4초를 하나의 주기로 팔꿉을 반복적 등장성으로 굽히고 펴서 표면근전도 신호를 얻었다. 처리과정 A 중앙주파수(MDF )는 이 신호의 0.5초 구간을 power spectrum analy sis (PSA)로 계산하였는데 상당량의 잡음이 있었다. 중앙주파수의 잡음 양을 비교하기 위해, 동일한 표면근전도에서 3번까지 신호를 받았다 (2.4초 구간을 PSA로 계산한 처리과정 B, 13 point 로 moving averages한 처리과정 C, digital low pass filter한 처리과정 D). 그리고 나서 그 신호의 주요 주파수 성분을 뽑아내었다. 위의 중앙주파수 자료와 시간간의 회귀직선을 분석하면 초기 중앙주파수, 회귀기울기, 그리고 피로지수와 같은 모수를 얻을 수 있다. 비모수 검정의 하나인 Kendall 기법으로 네 개의 처리과정간의 모수를 비교하였다. 통계결과 잡음이 처리과정 A보다 B, C, D에서 적었고, D에서 가장 적게 나타났다. 중앙주파수를 digital low pass로 여과(filtering)함으로써 앞으로 있게 될 동적 운동 시 근피로 모니터기의 신뢰도를 높일 수 있다.

  • PDF

A Study on Biomechanical Noise Reduction Technique Using Length Information (길이 정보를 이용한 생체 잡음 제거 기술에 관한 연구)

  • Gang, Sin-Gil;Yun, Yong-San;Park, Jae-Hui
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.7 s.178
    • /
    • pp.1643-1649
    • /
    • 2000
  • When markers attached to body segment are captured by camera, they generally have many noises due to intrinsic biomechanical characteristics. In this study, one technique to reduce these noises is suggested, which constructs a local coordinates of the markers using time-mean lengths of the measured markers and calculates a linear transformation matrix of the interesting body using least square error technique. This matrix is decomposed into two matrices of rotation and flexibility. Suggested method does well for 3 markers or more, and shows consistent results without regard to choice of reference axis.

Cluster Feature Selection using Entropy Weighting and SVD (엔트로피 가중치 및 SVD를 이용한 군집 특징 선택)

  • Lee, Young-Seok;Lee, Soo-Won
    • Journal of KIISE:Software and Applications
    • /
    • v.29 no.4
    • /
    • pp.248-257
    • /
    • 2002
  • Clustering is a method for grouping objects with similar properties into a same cluster. SVD(Singular Value Decomposition) is known as an efficient preprocessing method for clustering because of dimension reduction and noise elimination for a high dimensional and sparse data set like E-Commerce data set. However, it is hard to evaluate the worth of original attributes because of information loss of a converted data set by SVD. This research proposes a cluster feature selection method, called ENTROPY-SVD, to find important attributes for each cluster based on entropy weighting and SVD. Using SVD, one can take advantage of the latent structures in the association of attributes with similar objects and, using entropy weighting one can find highly dense attributes for each cluster. This paper also proposes a model-based collaborative filtering recommendation system with ENTROPY-SVD, called CFS-CF and evaluates its efficiency and utilization.

Automatic Detection of Foreign Body through Template Matching in Industrial CT Volume Data (산업용 CT 볼륨데이터에서 템플릿 매칭을 통한 이물질 자동 검출)

  • Ji, Hye-Rim;Hong, Helen
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.12
    • /
    • pp.1376-1384
    • /
    • 2013
  • In this paper, we propose an automaticdetection method of foreign bodies through template matching in industrial CT volume data. Our method is composed of three main steps. First,Indown-sampling data, the product region is separated from background after noise reduction and initial foreign-body candidates are extracted using mean and standard deviation of the product region. Then foreign-body candidates are extracted using K-means clustering. Second, the foreign body with different intensity of product region is detected using template matching. At this time, the template matching is performed by evaluating SSD orjoint entropy according to the size of detected foreign-body candidates. Third, to improve thedetection rate of foreign body in original volume data, final foreign bodiesare detected using percolation method. For the performance evaluation of our method, industrial CT volume data and simulation data are used. Then visual inspection and accuracy assessment are performed and processing time is measured. For accuracy assessment, density-based detection method is used as comparative method and Dice's coefficient is measured.

The Study on the Reduction of Patient Surface Dose Through the use of Copper Filter in a Digital Chest Radiography (디지털 흉부 촬영에서 구리필터사용에 따른 환자 표면선량 감소효과에 관한 연구)

  • Shin, Soo-In;Kim, Chong-Yeal;Kim, Sung-Chul
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.223-228
    • /
    • 2008
  • The most critical point in the medical use of radiation is to minimize the patient's entrance dose while maintaining the diagnostic function. Low-energy photons (long wave X-ray) among diagnostic X-rays are unnecessary because they are mostly absorbed and contribute the increase of patient's entrance dose. The most effective method to eliminate the low-energy photons is to use the filtering plate. The experiments were performed by observing the image quality. The skin entrance dose was 0.3 mmCu (copper) filter. A total of 80 images were prepared as two sets of 40 cuts. In the first set (of 40 cuts), 20 cuts were prepared for the non-filter set and another 20 cuts for the Cu filter of signal + noise image set. In the second set of 40 cuts, 20 cuts were prepared for the non-filter set and another 20 cuts for the Cu filter of non-signal image (noisy image) with random location of diameter 4 mm and 3 mm thickness of acryl disc for ROC signal at the chest phantom. P(S/s) and P(S/n) were calculated and the ROC curve was described in terms of sensitivity and specificity. Accuracy were evaluated after reading by five radiologists. The number of optically observable lesions was counted through ANSI chest phantom and contrast-detail phantom by recommendation of AAPM when non-filter or Cu filter was used, and the skin entrance dose was also measured for both conditions. As the result of the study, when the Cu filter was applied, favorable outcomes were observed on, the ROC Curve was located on the upper left area, sensitivity, accuracy and the number of CD phantom lesions were reasonable. Furthermore, if skin entrance dose was reduced, the use of additional filtration may be required to be considered in many other cases.

  • PDF

Quantitative Analysis of Artifactual Perfusion Defects due to the Cutoff Frequencies of Reconstruction Filters in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT에서 재구성필터의 차단주파수에 의한 인위적 관류결손의 정량적 평가)

  • Kwark, Cheol-Eun;Chung, June-Key;Lee, Myung-Chul
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.231-238
    • /
    • 1995
  • Tc-99m-MIBI (Sestamibi) myocardial SPECT along with TI-201 tomographic Imaging has demonstrated wide application and high image quality sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow. The qualitative values of myocardial SPECT with Tc-99m-MIBI as well ds the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection (FBP) Is the common standard method for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected litter parameters such as cutoff frequencies and order (Butterworth case) The cutoff frequencies used in clinicAl practice partially remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for Identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable threshold of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Wyquist frequency would reveal severe degradation of radioactive distribution near inferior and/or inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF

Artifactual Perfusion Defects due to the Parameters of Reconstruction Filter in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT 영상에서 재구성 필터에 의한 인위적 관류결손에 관한 연구)

  • Kwark, Cheol-Eun;Lee, Kyung-Han;Lee, Dong-Soo;Park, Yong-Woo;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.41-47
    • /
    • 1995
  • Tc-99m-MIBI(Sestamibi) myocardial SPECT along with T1-201 tomographic imaging has demonstrated wide application and high image qualify sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow, The qualitative values of myocardial SPECT with Tc-99m-MIBI as well as the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection(FBP) is the common standard for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it Is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected filter parameters such as cutoff frequencies and order(Butterworth case). The cutoff frequencies basically remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable thresh-old of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Nyquist frequency would reveal severe degradation of radio-active distribution near inferior and/or Inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF