• Title/Summary/Keyword: 잡음 대 신호비

Search Result 1,297, Processing Time 0.027 seconds

A Performance of a Remote Speech Input Unit in Speech Recognition System (음성인식 시스템에서의 원격 음성입력기의 성능평가)

  • Lee, Gwang-seok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.723-726
    • /
    • 2009
  • In this research, We simulated performances of error reduction algorithm for the speech signal based on the microphone array-based beamforming method in speech recognition system and analyzed its performance. Also, we processed speech signal adopted from microphone array and maximum signal to noise ratio for each channel, and then compared them with signal to noise ratio of speech signal. Speech recognition rate is improved from 54.2% to 61.4% in case 1 and is improved from 41.2% to 50.5% in case 2 of the lower signal to noise ratio. Therefore the average reduction rates are showed 15.7% in case 1.

  • PDF

A Study on the P Wave Arrival Time Determination Algorithm of Acoustic Emission (AE) Suitable for P Waves with Low Signal-to-Noise Ratios (낮은 신호 대 잡음비 특성을 지닌 탄성파 신호에 적합한 P파 도달시간 결정 알고리즘 연구)

  • Lee, K.S.;Kim, J.S.;Lee, C.S.;Yoon, C.H.;Choi, J.W.
    • Tunnel and Underground Space
    • /
    • v.21 no.5
    • /
    • pp.349-358
    • /
    • 2011
  • This paper introduces a new P wave arrival time determination algorithm of acoustic emission (AE) suitable to identify P waves with low signal-to-noise ratio generated in rock masses around the high-level radioactive waste disposal repositories. The algorithms adopted for this paper were amplitude threshold picker, Akaike Information Criterion (AIC), two step AIC, and Hinkley criterion. The elastic waves were generated by Pencil Lead Break test on a granite sample, then mixed with white noise to make it difficult to distinguish P wave artificially. The results obtained from amplitude threshold picker, AIC, and Hinkley criterion produced relatively large error due to the low signal-to-noise ratio. On the other hand, two step AIC algorithm provided the correct results regardless of white noise so that the accuracy of source localization was more improved and could be satisfied with the error range.

Voice Activity Detection in Noisy Environment using Speech Energy Maximization and Silence Feature Normalization (음성 에너지 최대화와 묵음 특징 정규화를 이용한 잡음 환경에 강인한 음성 검출)

  • Ahn, Chan-Shik;Choi, Ki-Ho
    • Journal of Digital Convergence
    • /
    • v.11 no.6
    • /
    • pp.169-174
    • /
    • 2013
  • Speech recognition, the problem of performance degradation is the difference between the model training and recognition environments. Silence features normalized using the method as a way to reduce the inconsistency of such an environment. Silence features normalized way of existing in the low signal-to-noise ratio. Increase the energy level of the silence interval for voice and non-voice classification accuracy due to the falling. There is a problem in the recognition performance is degraded. This paper proposed a robust speech detection method in noisy environments using a silence feature normalization and voice energy maximize. In the high signal-to-noise ratio for the proposed method was used to maximize the characteristics receive less characterized the effects of noise by the voice energy. Cepstral feature distribution of voice / non-voice characteristics in the low signal-to-noise ratio and improves the recognition performance. Result of the recognition experiment, recognition performance improved compared to the conventional method.

Underwater Transient Signal Detection Using Higher-order Statistics and Wavelet Analysis (고차통계 기법과 웨이브렛을 이용한 수중 천이신호 탐지)

  • 조환래;오선택;오택환;나정열
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.8
    • /
    • pp.670-679
    • /
    • 2003
  • This paper deals with application of wavelet transform, which is known to be good for time-frequency analysis, in order to detect the underwater transient signals embedded in ambient noise. A new detector of acoustic transient signals is presented. It combines two detection tools: wavelet analysis and higher-order statistics. Using both techniques, the detection of the transient signal is possible in low signal to noise ratio condition. The proposed algorithm uses the wavelet transform of a partition of the signal on frequency domain, and then higher-order statistics tests the Gaussian nature of the segments.

An alternative procedure for parameter design using desirability function in combined array (통합배열에서 기대함수를 이용한 파라미터설계 대체방안)

  • Kwon, Yong Man
    • Journal of the Korean Data and Information Science Society
    • /
    • v.27 no.5
    • /
    • pp.1263-1272
    • /
    • 2016
  • Product array approach which is used in the Taguchi parameter design has a number of advantages by considering the noise factor. However, a disadvantage of this method is that it requires an excessively large number of experiments. So combined array approach have been proposed to reduce the number of experiments. Taguchi has used the signal-to-noise ratio to find the optimum conditions in the Taguchi parameter design. In analyzing the data from the parameter design various problems tends occur by using an SN. In this paper, we propose an alternative solution for reducing the number of experiments without depending on the signal-to-noise ratio to overcome the shortcomings of the parameter design. Two examples illustrate this procedure in the two different experimental design (product array, combined array) approaches.

Error Performance Analysis of Digital Radio Signals in an Electromagnetic Interference (EMI) Environment of Impulsive Noise Plus Disturbance (임펄스 잡음과 방해파에 의한 전자파 장해(EMI) 환경하에서의 디지털 무선통신 신호의 오율해석)

  • Cho, Sung-Eon;Leem, Kill-Yong;Cho, Sung-Joon;Lee, Jin
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.3
    • /
    • pp.36-54
    • /
    • 1995
  • The error performance of digital radio signals (i.e., M-ary PSK signal, DQPSK signal, MSK signal, GMSK signal) interfered by impulsive noise and electromagnetic interference (EMI) is analyzed and discussed. In analysis at first, the error rate equations have been derived in an electromagnetic interference plus impulsive noise environment. And then, the error performance has been evaluated and shown in figures as a function of carrier-to-noise ratio, carrier-to-interference ratio, impu- lsive index, gaussian noise to impulsive noise power ratio, and interference index to measure the amount of error degradation in digital radio signals. From the obtained results we have known that in the presence of m-distributed tone interference plus inpulsive noise, the more significant the electromagnetic interference amplitude varies, the more significant performance degradation is produced. The listing the digital radio signals from the most degraded to the least is that DQPSK, GMSK, QPSK and MSK signal. In the constant amplitude tone interference plus impulsive noise environment, the effect of in- terference nearly disappears over about 20dB in CIR. The effect of constant tone interference on error rate performance is reduced more remarkably in the region from 10dB to 15dB in CIR. In both enviroments of m-distributed tone interference and constant amplitude tone interference, the more electromagnetic interference amplitude varies and CIR increases, the more error perfor- mance is improved. But it is found out that the performance can not be improved significantly even the electromagnetic interference becomes weak. This describes that the impulsive noise affects dominantly to the performance degradation.

  • PDF

Study of Miniature Fluorescence Detection System for Protein Chip (단백질 칩용 초소형 미세형광측정 시스템에 관한 연구)

  • Seong, Cheon-Ya;Kim, Ho-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1944-1946
    • /
    • 2003
  • 질병의 발현과 직접적인 관련이 있는 단백질의 검출, 정량화하는 분석 장비를 소형화 할 수 있는 방법을 소개하고 그 가능성을 실험적으로 확인하였다. 단백질 검출을 위한 형광측정방법에서 가장 큰 문제인 여기광과의 혼재로 인한 신호 대 잡음 비를 해결하기 위해 마이크로 프리즘을 이용한 여기 방식을 고안하고 설계, 시뮬레이션 하였으며, 선행 실험을 통해 프리즘의 이용한 형광검출방법이 신호 대 잡음 비의 향상과 분석 시스템의 소형화에 효과적임을 확인하였다.

  • PDF

Dynamic MR Imaging in Gastric Cancer : Comparison Between Precontrast and Postcontrast Images (위암의 역동적 자기공명영상: 조영증강 전 후 영상의 비교)

  • 홍성환;한준구;장기현;최병인
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.130-134
    • /
    • 1997
  • Purpose: To analyze contrast-enhancement pattern of stomach cancer on dynamic MRI and to verify the efficacy of intravenous contrast agent in the evaluation of stomach cancer. Materials and Methods: Twelve patients with proven stomach cancer underwent dynamic MRI. By using l.OT scanner, we obtained precontrast FLASH images, and 30, 60, 90 second delay FLASH images after intravenous contrast injection. All patients ingested one liter of water and had intramuscular injection of Buscopan just before MR study. For quantitative analysis we measured signal to noise ratio (SiN) of stomach cancer on each image, and signal difference to noise ratio (SD/N) between cancer and intraluminal fluid, cancer and the pancreas. For qualitative analysis two radiologists evaluated lesion conspicuity on each image by grading system(grade 0, 1, 2, 3: poor, fair, good, excellent). Results: SiN of stomach cancer increased gradually by time(precontrast, 30, 60, 90 second delay: 38.7, 42.5, 57.4, 65.7). SD/N between cancer and intraluminal fluid significantly increased after contrast enhancement(l.24, 25.01, 39.30, 45.89). SD/Ns between cancer and the pancreas were 10.5, 9.33, 9.99, 10.66, respectively. In qualitative analysis, precontrast images were better than postcontrast images for delineation of stomach cancer. Postcontrast images showed clear endo-Iuminal side of stomach cancer, but outer margin of stomach cancer was more distinct on precontrast images. Conclusion: Precontrast MR images are better than postcontrast MR images in the depiction of stomach cancer. Intravenous contrast agent is not imperative in the evaluation of stomach cancer.

  • PDF

Comparative assessment of a 1.5T endorectal coil and a 3.0T phased-array coil available for prostate MRI (전립선 MRI에서 사용하는 1.5T 경직장 코일과 3.0T 위상 배열 코일의 성능 비교 평가)

  • Cho, Jae-Hwan
    • Journal of Digital Contents Society
    • /
    • v.11 no.3
    • /
    • pp.283-290
    • /
    • 2010
  • The effectiveness of 3.0T phase array coil images was tested by comparing signal-to-noise ratios for the same coil images relative to 1.5T endorectal coil images. Signal intensities were measured in the three regions of prostate, central and peripheral (right and left) after 40 patients with prostate cancer were imaged during the period between Jan. 2008 and Oct. 2009 with T2 W, T1 W, and DW images obtained respectively using endorectal coil on a 1.5T MR scanner and phase array coil on a 3.0T MR scanner. For quantitative analysis, comparisons of average SNRs for the same ROIs were made between groups scanned with a 1.5T and a 3.0T MR scanner. The signal-to-noise ratios were shown to increase more sharply when using a phase array coil at a 3.0T MR scanner compared to using an endorectal coil at a 1.5T MR scanner.

Hardware Design of SNR Estimator for Adaptive Satellite Transmission System (적응형 위성 전송 시스템을 위한 신호 대 잡음비 추정 회로 구현)

  • Lee, Jae-Ung;Kim, Soo-Seong;Park, Eun-Woo;Im, Chae-Yong;Yeo, Sung-Moon;Kim, Soo-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.2A
    • /
    • pp.148-158
    • /
    • 2008
  • This paper proposes an efficient signal to noise ratio (SNR) estimation algorithm and its hardware implementation for adaptive transmission system using M-ary modulation scheme. In this paper, we present the implementation results of the proposed algorithm for the second generation digital video broadcasting via satellite (DVB-S2) system, and the proposed algorithm can be tailored to the other communication systems using adaptive transmissions. We built a look-up table (LUT) using the theoretical background of the received signal distribution, and by using this LUT we need just two comparators and a counter for the hardware implementation. For this reason, the hardware of the proposed scheme produces accurate estimation results even with extremely low complexity. The simulation results investigated in this paper reveal that the proposed method can produce estimation results within the specified SNR range in the DVB-S2 system, and it requires a few hundreds of samples for average estimation error of about 1 dB.