• Title/Summary/Keyword: 잡음원

Search Result 813, Processing Time 0.023 seconds

Preliminary Study on the Relationship between Self-Induced Mental Imagery and GSR - Comparison among Mental Imageries Inducing Pleasantness or Unpleasantness and Mental Arithmetic (심상자극과 GSR의 관계에 대한 예비연구 - 쾌.불쾌를 유발하는 심상자극과 암산과제에 대한 SCL 반응비교)

  • 이봉건;정인원;김재진;신철진
    • Science of Emotion and Sensibility
    • /
    • v.5 no.2
    • /
    • pp.11-22
    • /
    • 2002
  • This study investigated the effects of mild mental imagery inducing pleasantness or unpleasantness and cognitive mental arithmetic task on skin conductance level. Subjects were f undergraduates(male 5, female 4). They were given the list of the words and asked to write down the liked objects and the disliked ones freely associated with these words. Among these objects the most-liked one and the most disliked one were selected as the self-induced mental imageries. Data-collection procedures were as follows ; first baseline, pleasant imagery, 2nd baseline, unpleasant imagery, finally 3rd baseline, and mental arithmetic task subtracting continuously 7 from the number 500. During these trials, the SCLs were recorded every 10 seconds. The results indicated that there were nonsignificant differences between the 3 trial-baselines ot each condition. This suggested that unlike the procedures used in the previous studies, our procedures would give the stability of the baseline level necessary for the comparison of the effects of several stimuli. Also, the level of skin conductance in mental arithmetic condition was significantly higher than that of the emotional mental imagery. This suggested the possibility that mental arithmetic task would gave rise to the higher physiological arousal in comparison to mental imageries. Overall, it was suggested that the procedures and the stimulus presentation methods used in this preliminary study could be useful for the data-collection techniques for The future study. Implications for the future study were presented.

  • PDF

A Study on the Optimal Angle as Modified Tangential Projection of Knee Bones (무릎뼈의 변형된 접선방향 검사 시 최적의 입사각에 관한 연구)

  • Oh, Wang-Kyun;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.919-926
    • /
    • 2021
  • In this study, we wanted to find out the optimal angle as a modified tangential projection of the patella. In the experiment, we used Kyoto Kagaku's PBU-50 phantom. In the supine position, the F-T angle was set to 95°, 105°, 115°, 125°, 135°, 145°, and Patella tangential projection images were obtained by varying the X-ray tube angle by 5° so that the angle between the X-ray centerline and tibia at each angle was 5~20°. Image J was used for image analysis and the congruence angle, lateral patellofemoral angle, patellofemoral index and contrast to noise ratio(CNR) were also measured. SPSS 22 was used for statistical analysis, and the mean values of congruence angle, patellofemoral angle, patellofemoral index, and CNR were compared with Merchant method through one-way batch analysis and corresponding sample t-test. As a result of the study, in the case of congruence angle, the angle of incidence of the knee-angle X-ray centerline was 105°-72.5° (20° tangential irradiation), 115°-72.5°, 77.5° (15, 20° tangential irradiation), 125°-82.5° (20° tangential irradiation), lateral patellofemoral angle is 115°-72.5°, 77.5° (15, 20° tangential irradiation), 125°-72.5° (10° tangential irradiation), patellofemoral index is 115°-72.5° (15° tangential irradiation) and 125°-72.5° (10° tangential irradiation) were not significantly different from Merchant method (p> .05). In case of CNR, it is not different from Merchant method at 105°-67.5°, 72.5° (15, 20° tangential irradiation), 115°-67.5°, 72.5°, 77.5° (10, 15, 20° tangential irradiation). (P> .05). Based on the results of this study, high diagnostic value images can be obtained by setting the knee angle and the angle of incidence of the X-ray tube to 115°-72.5° (15° tangential irradiation) during the modified tangential examination of the knee bone. It was confirmed.

Uncertainties of SO2 Vertical Column Density Retrieval from Ground-based Hyper-spectral UV Sensor Based on Direct Sun Measurement Geometry (지상관측 기반 태양 직달광 관측장비의 초분광 자외센서로부터 이산화황 연직칼럼농도의 불확실성 분석 연구)

  • Kang, Hyeongwoo;Park, Junsung;Yang, Jiwon;Choi, Wonei;Kim, Daewon;Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.2
    • /
    • pp.289-298
    • /
    • 2019
  • In this present study, the effects of Signal to Noise Ratio (SNR), Full Width Half Maximum (FWHM), Aerosol Optical Depth (AOD), $O_3$ Vertical Column Density ($O_3$ VCD), and Solar Zenith Angle (SZA) on the accuracy of sulfur dioxide Vertical Column Density ($SO_2$ VCD) retrieval have been quantified using the Differential Optical Absorption Spectroscopy (DOAS) method with the ground-based direct-sun synthetic radiances. The synthetic radiances produced based on the Beer-Lambert-Bouguer law without consideration of the diffuse effect. In the SNR condition of 650 (1300) with FWHM = 0.6 nm, AOD = 0.2, $O_3$ VCD = 300 DU, and $SZA=30^{\circ}$, the Absolute Percentage Difference (APD) between the true $SO_2$ VCD values and those retrieved ranges from 80% (28%) to 16% (5%) for the $SO_2$ VCD of $8.1{\times}10^{15}$ and $2.7{\times}10^{16}molecules\;cm^{-2}$, respectively. For an FWHM of 0.2 nm (1.0 nm) with the $SO_2$ VCD values equal to or greater than $2.7{\times}10^{16}molecules\;cm^{-2}$, the APD ranges from 6.4% (29%) to 6.2% (10%). Additionally, when FWHM, SZA, AOD, and $O_3$ VCD values increase, APDs tend to be large. On the other hand, SNR values increase, APDs are found to decrease. Eventually, it is revealed that the effects of FWHM and SZA on $SO_2$ VCD retrieval accuracy are larger than those of $O_3$ VCD and AOD. The SZA effects on the reduction of $SO_2$ VCD retrieval accuracy is found to be dominant over the that of FWHM for the condition of $SO_2$ VCD larger than $2.7{\times}10^{16}molecules\;cm^{-2}$.