• Title/Summary/Keyword: 잔류 강도

Search Result 830, Processing Time 0.027 seconds

Flexural Performance Characteristics of High Performance Slurry Infiltrated Fiber Reinforced Cementitious Composite according to Fiber Volume Fraction (섬유혼입률에 따른 고성능 슬러리 충전 강섬유보강 시멘트 복합체의 휨성능 특성)

  • Kim, Seung-Won;Cho, Hyun-Myung;Lee, Hak-Yong;Park, Cheol-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.109-115
    • /
    • 2015
  • High performance fiber reinforced cementitious composite (HPFRCC) can provide high fracture energy absorption as well as high strength with high fiber volume fraction. The increased fracture energy helps resisting high frequency loadings, such as earthquake, impact or blast. This study investigates the flexural performance of slurry infiltrated fiber concrete (SIFCON), one of the important HPFRCC, with respect to varying fiber volume fraction. The maximum fiber volume fraction was 8.0 % and reduced to 6.0% by 0.5% and the maximum volume fraction is obtained by packing fibers with simple tapping by hands. The used fiber was a steel fiber with the length 30 mm and the diameter of 0.5 mm. The flexural strengths were 48.7 MPa at 8.0 % and 22.8 MPa at 6.0 %. The measured flexural strength is much higher compared to other cememtitious composite materials but decreased proportional to the fractions. This result implies that for SIFCON considered herein the reduced amount of steel fibers may affect its flexural performance in a negatively way. The flexural toughness, an index to represent the fracture energy absorption, also decreased with the reduced fiber amount.

Seismic Performance and Flexural Over-strength of Circular RC Column (원형 RC 기둥의 내진성능과 휨 초과강도)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.49-58
    • /
    • 2013
  • Eight small scale circular reinforced concrete columns were tested under cyclic lateral load with constant axial load. Test specimens were designed with 4.5 aspect ratio. The selected test variables are longitudinal steel ratio, transverse steel ratio, yielding strength of longitudinal steel and axial load ratio. The test results of columns with different longitudinal steel ratio, transverse steel ratio and axial load ratio showed different seismic performance such as equivalent damping ratio, residual displacement and effective stiffness. It was found that the column with low strength of longitudinal steel showed significantly reduced seismic performance, especially for equivalent damping ratio and residual displacement. The regulation of flexural over-strength is adopted by Korea Bridge Design Specifications (Limited state design, 2012). The test results are compared with nominal strength, result of nonlinear moment-curvature analysis and the design specifications such as AASHTO LRFD and Korea Bridge Design Specifications (Limited state design).

A Study on Inelastic Behavior of Monosymmetric Singly Stepped Beam Subjected to Uniform Load (등분포 하중을 받는 일축대칭 일단 스텝보의 비탄성 거동 특성 고찰)

  • Park, Yi-Seul;Park, Jong-Sub
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.738-740
    • /
    • 2012
  • 최근 변단면 거더의 경제성을 고려하여 장경간 거더 교량과 강골조 구조물에 변단면보의 사용이 증가하고 있으며, 고강도 강의 등장으로 인해 변단면보의 정확한 좌굴 강도의 평가가 매우 중요시 되고 있다. 본 논문에서는 기존에 연구된 탄성 횡-비틀림 좌굴 강도에 관한 연구를 바탕으로하여 별로 비탄성 구간에 비지지 길이가 존재하는 일축대칭 I형 변단면보의 횡-비틀림 좌굴 강도 해석을 실시하였다. 해석에는 유한요소해석프로그램인 ABAQUS(2007)가 사용되었으며, MINITAB(2006)을 이용하여 간편한 설계식을 제안하고 있다. 일단 계단식 단면을 가지는 보에 대하여 고려하였으며, 플랜지 길이 방향 비, 너비방향 비, 두께의 비로 계단식 I형 보를 나타내었다. 집중 하중을 적용시켰으며 비선형 해석을 위해 잔류응력 및 초기변형과 재료비선형을 고려하였다. 본 연구 결과에서 제안된 식은 향후 다양한 하중이 작용하는 비탄성 횡-비틀림 좌굴 강도에 대한 연구에 많은 도움이 될 것이다.

  • PDF

Characteristics of Shear Behavior According to State of Particle Bonding and Crushing (입자 결합 및 파쇄 형태에 따른 전단거동 특성)

  • Jeong, Sun-Ah;Kim, Eun-Kyung;Lee, Seok-Won
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.2
    • /
    • pp.1-12
    • /
    • 2011
  • In order to analyze the influence of particle bonding and crushing on the characteristics of shear behavior, especially residual shear behavior of granular soil, ring shear test was simulated by using DEM(Discrete Element Method)-based software program PFC(Particle Flow Code). Total four models including two non-crushing models and two crushing models were created in this study by using clump or cluster model built in PFC. The applicability of Lobo-crushing model proposed by Lobo-Guerrero and Vallejo(2005) was investigated. In addition, the results of ring shear test were analyzed and compared with those of direct shear test. The results showed that the modelling of ring shear test should be conducted to investigate the residual shear behavior. The Lobo-crushing model cannot be applied to investigate the residual shear strength. Finally, it can be concluded that the numerical models excluding Lobo-crushing model suggested in this study can be used extensively for other studies concerning the residual shear behavior of granular soil including soil crushing.

A Study on Fatigue Design Automation of Plug- and Ring-type Gas-welded Joints of STS301L Taking Welded Residual Stress into Account (용접잔류응력을 고려한 STS301L 플러그 및 링 용접부의 피로설계 자동화에 관한 연구)

  • Baek, Seung-Yeb;Yun, Ki-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1137-1143
    • /
    • 2010
  • This paper presents a fatigue design method for plug- and ring-type gas-welded joints, which takes into account the effects of welding residual stress. To develop this method, we simulated the gas-welding process by performing nonlinear finite element analysis (FEA) To validate the FEA results, numerically calculated residual stresses in the gas welds were then compared with experimental results obtained by the hole-drilling method. To evaluate the fatigue strength of plug- and ring-type gas-welded joints influenced by welding residual stresses, the use of stress amplitude $(\sigma_a)_R$, which includes the welding residual stress in gas welds, is proposed $(\sigma_a)_R$ on the basis of a modified Goodman equation that includes the residual stress effects. Using the stress amplitude $(\sigma_a)_R$ at the hot spot point of gas weld, the relations obtained as the fatigue test results for plug and ring type gas welded joints having various dimensions and shapes were systematically rearranged to obtain the $(\sigma_a)_R-N_f$ relationship. It was found that more systematic and accurate evaluation of the fatigue strength of plug- and ring-type gas-welded joints can be achieved by using $(\sigma_a)_R$.

Removal of Residual Stress and In-vitro Recording Test in Polymer-based 3D Neural Probe (폴리머 기반 3차원 뉴런 프로브의 잔류 스트레스 제거 및 생체 외 신호 측정)

  • Nam, Min-Woo;Lim, Chun-Bae;Lee, Kee-Keun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.2
    • /
    • pp.33-42
    • /
    • 2009
  • A polymer-based flexible neural probe was fabricated for monitoring of neural activities from a brain. To improve the insertion stiffness, a 5 ${\mu}m$ thick biocompatible Au layer was electroplated between the top and bottom polymer layers. The developed neural probe penetrated a gel whose elastic modulus is similar to that of a live brain tissue without any fracture, To minimize mechanical residual stress and bending from the probe, two new methods were employed: (1) use of a thermal annealing process after completing the device and (2) incorporation of multiple different layers to compensate the residual stress between top and bottom layers. Mechanical bending around the probe tip was clearly removed after employing the two processes. In electrical test, the developed probe showed a proper impedance value to record neural signals from a brain and the result remained the same for 72 hours. In simple in-vitro probe characterization, the probe showed a great removal of residual stress and an excellent recording performance. The in-vitro recording results did not change even after 1 week, suggesting that this electrode has the potential for great recording from neuron firing and long-term implant performance.

  • PDF

On the Organechlorine Pesticide Residues in Downstream Area of Nakdong River (낙동강(洛東江) 하류지역(下流地域)에 있어서 유기염소계(有機鹽素系) 살충제(殺蟲劑) 농약(農藥)의 잔류평가(殘留評價))

  • You, Sun-Jae;Park, Chung-Kil
    • Applied Biological Chemistry
    • /
    • v.27 no.3
    • /
    • pp.187-197
    • /
    • 1984
  • Samples (river water, tap water, soil, sediment, fish and shellfish) collected in Downstream Area of Nakdong River were analyzed for organochlorine pesticides by G.C. equipped with electron capture detector. Residue levels of organochlorine pesticides in the river water and tap water ranged from less than detection limit (ND) to 56ppt. Total BHC concentration in the river water and tap water were found to increase in summer and decrease in winter. The variation appeared to be related to rain fall. ${\alpha}-BHC\;and\;{\beta}-BHC$ concentration in the soil were ND-3.3ppb and ND-769.7ppb, respectively. ${\alpha}-BHC\;and\;{\beta}-BHC$ concentration in the sediment were ND-2.0ppb and ND-409.9ppb, respectively. Concentration factor of total BHC in the sediment ranged from 83 to 3213. In fish, Carasssus carassius and shellfish, Anodonta woodiana(Lea) the concentration factor of ${\beta}-BHC$ and total BHC were 2,609, 435 and 3,261, 375, respectively.

  • PDF

Evaluation of Microscopic Deformation Behaviors of Metal Matrix Composite due to Heat Treatment by means of SFC Test and Acoustic Emission (음향방출과 SFC 시험법에 의한 금속복합재료의 기지재 열처리 효과에 따른 미시적 변형기구 특성 평가)

  • Kang, Moon-Phil;Lee, Joon-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.5
    • /
    • pp.381-389
    • /
    • 2000
  • Metal matrix composite(MMCs) have been rapidly becoming one of the strongest candidates for structural materials for high temperature application. It is well recognized that MMCs always experience at least one large cool-down from processing temperature before my significant applied service loading. Due to the large difference in thermal expansion coefficient between the fiber and matrix, large thermal residual stresses generally develop in composites. It was reported from many previous studies that the effects of thermal residual stress on mechanical properties and fracture behavior were much more complex and dramatic than conventional engineering materials. Therefore it is crucial to evaluate the effect of heat treatment which changes the characteristic of distribution of thermal residual stress in MMCs. Single fiber composite(SFC) test based on the balance in a micromechanical model is a quite convenient method to evaluate interfacial shear strength(IFSS) and the failure mode of composite. In this study the effect of heat treatment on IFSS and the microscopic failure mechanism of MMC is investigated by combining acoustic emission(AE) technique with SFC test. The characteristic of AE signal, IFSS and microscopic failure mechanism due to heat treatment condition is discussed.

  • PDF

Residual Stress Measurement for Circular Disk Using Fraction Mechanics Approach (파괴역학을 이용한 원판형 부재의 잔류응력 측정)

  • 강기주;최성렬
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1218-1226
    • /
    • 1993
  • A method, so called 'successive cracking method,' for measuring residual stresses in a circular disk is proposed. In this method residual stresses are evaluated using a fracture mechanics approach, that is, the strains measured at a point on a edge of the disk as a crack is introduced and extended from the edge are used to deduce the residual stress distribution which existed in the uncracked disk. Through finite element analysis and comparative experiments with generally used sectioning method, the successive cracking method is shown to be valid, simple and effective to measure 2-dimensional residual stress distribution in a circular disk.

Evaluation of weld joint properties with length of inserted short pipe at the time of pipeline welding (배관용접시 단관삽입길이에 따른 용접부 특성 평가)

  • Kim Cheol-man;Kim Woo-sik;Kim Young-seob;Kwon Jeong-rock
    • 한국가스학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.53-58
    • /
    • 2003
  • API 5L X65 배관에 50mm이상의 단관을 삽입하여 용접하였을 경우, 삽입된 단관 길이 변화에 따른 용접부 기계적 특성 평가 결과를 요약하면 다음과 같다. 1. 단관삽입 용접부위의 거시적 조직관찰, 미소경도측정, 인장시험, 굽힘시험을 수행한 결과, 단관삽입 용접부의 건전성에는 문제가 없는 것으로 평가되었다. 2. 단관삽입 용접부의 원주방향 최대 인장 잔류응력의 크기는 단관 삽입 길이에 관계없이 약 150MPa로서 그리고 최대 압축 잔류응축은 약 300MPa로 측정되었다. 모재의 항복강도가 492MPa인 것과 비교하여보면 단관 삽입 용접에 의한 잔류응력의 영향은 매우 작은 것으로 평가되었다.

  • PDF