• Title/Summary/Keyword: 작동 온도

Search Result 930, Processing Time 0.025 seconds

Electrochemical Stability of Co-Mo and Ni-Mo Intermetallic Compound Electrodes for Hydrogen Electrode of Alkaline Fuel Cell (알칼리형 연료전지의 수소극용 Co-Mo 및 Ni-Mo 금속간화합물 전극의 전기화학적 안정성)

  • Lee C. R.;Kang S. G.
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.3
    • /
    • pp.150-155
    • /
    • 1999
  • The Electrochemical stabilities of the Brewer-Engel type intermetallic compounds of Co-Mo $(35 wt\%)$ and Ni-Mo$(35 wt\%)$ manufactured by the arc-melting method for the hydrogen electrode of $H_2-O_2$ alkaline fuel cell were investigated. Effects of temperature and concentration on the electrochemical behavior of the electrodes in the $80^{\circ}C$ 6 N KOH solution deaerated with $N_2$ gas were studied by electrochemical methods. The effect of overpotential on the electrochemical stabilities of Co-Mo and Ni-Mo intermetallic compounds was also discussed under the normal operation condition of AFC. It was shown that Co-Mo electrode had lower electrochemical stability as compared to Ni-Mo. In the case of Co-Mo electrode, a simultaneous dissolution of cobalt and molybdenum has occurred at low anodic overpotential form equilibrium hydrogen electrode potential, but the dissolution of cobalt was serious, and Co(OH)l layer on the electrode surface formed at the high anodic overpotential. In contrast the Ni-Mo electrode had high electrochemical stability because formation of the dense and thin protective $Ni(OH)_2$ layer prevented the dissolution of molybdenum.

Multistable Microactuators Functioning on the Basis of Electromagnetic Lorentz Force: Nonlinear Structural and Electrothermal Analyses (전자기 로렌츠력을 이용한 다중안정성 마이크로 액추에이터의 비선형 구조 및 전기-열 해석)

  • Han, Jeong-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.8
    • /
    • pp.1119-1127
    • /
    • 2010
  • In this paper, the design and nonlinear simulation of a multistable electromagnetic microactuator, which provides four stable equilibrium positions within its operating range, have been discussed. Quadstable actuator motion has been made possible by using both X- and Y-directional bistable structures with snapping curved beams. Two pairs of the curved beams are attached to an inner frame in both X- and Y-directions to realize independent bistable behavior in each direction. For the actuation of the actuator at the micrometer scale, an electromagnetic actuation method in which Lorentz force is taken into consideration was used. By using this method, micrometer-stroke quadstability in a plane parallel to a substrate was possible. The feasibility of designing an actuator that can realize quadstable motion by using the electromagnetic actuation method has been thoroughly clarified by performing nonlinear static and dynamic analyses and electrothermal coupled-field analysis of the multistable microactuator.

Evaluating the Success Factors of Microfinance : A Case Study of Grameen Bank (마이크로파이넨스 성공요인 연구 : 그라민 은행 사례)

  • Nargis, Farhana;Lee, Sang-Ho;Kwon, Kyung-Sup
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.7 no.3
    • /
    • pp.65-73
    • /
    • 2012
  • Microfinance has been an important tool for the economic growth and poverty alleviation. But the success factors and risk factors have not been synthesized in academic literature. This article has paid attention to success factors and potential risk of the Grameen Bank. Grameen Bank methodology is almost the reverse of the conventional banking methodology. Conventional banking is based on the principle that the more you have, the more you can get. Founder of Grameen Bank, Professor Yunus pointed out that, "The least you have the highest you have the priority to receive a loan". On the basis of theoretical literature, there have been different kinds of success factors of microfinance observed in this paper. Key success factors of Grameen Bank are like these: innovation, strict administrative structure, adaptation and learning practice, incentive system. Complementary services such as business consulting and brokerage will contribute to borrowers' economic performance development.

  • PDF

A Study of the Cooling Effect of an Evaporation-Type Cool Roof Fan (기화방열식 Cool Roof Fan의 냉풍효과에 대한 연구)

  • Kim, Yeong Sik;Chung, Hanshik;Jeong, Hyomin;Choi, Soon-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.191-200
    • /
    • 2016
  • The ventilation effect of a ventilation system, which is classified as the forced ventilation and natural ventilation, is predominantly dependent on the combination of air supply and discharge. Perhaps the simplest ventilation is merely supplying the air as it is. However, to improve the indoor working environment during the summer, an air supply that is cooled to some extent has been widely adopted. Recently, a cooling method utilizing the vaporization of water was introduced. In this study, the performance of an evaporation-type air supply unit that was produced by Japan K-company and was installed in a shoe-manufacturing plant in Busan was investigated. The purpose of the experiment was to measure how much the supplied air could be cooled. From this experimental study, we confirmed that the evaporation-type air supply system is efficient, capable of improving the working environment during the summer while minimizing the energy cost.

Effect of Ultra-thin Catalyst Deposited upon $In_2O_3$ Thin Film on CO Sensitivity ($In_2O_3$ 박막위에 증착된 초박막 촉매가 CO의 검출 감도에 미치는 영향)

  • Lee, Hye-Jung;Song, Jae-Hoon;Kwon, Soon-Nam;Kim, Tae-Song;Kim, Kwang-Ju;Jung, Hyung-Jin;Choi, Won-Kook
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.430-439
    • /
    • 2000
  • $In_2O_3$-based thin film sensor with 500-600 nm thick was fabricated for the detection of CO gas by rf magnetron sputtering. In order to improve both sensitivity to CO gas and selectivity to hydrogen gas containing -CH, ultra-thin transition metal Co catalyst was sputtered over $In_2O_3$ thin film and annealed at $500^{\circ}C$. Sensitivity to CO was maximum at the thickness of Co 2.1 nm and $300^{\circ}C$, and that to $C_3H_8$ was at the thickness of Co 1.4 nm and $350-400^{\circ}C$. From the x-ray photoelectron spectroscopy (XPS) result, ultra-thin Co was existed into CoO covered with $Co_2O_3$ on $In_2O_3$ particles, and thus p-n junction of $In_2O_3(n-type)$-CoO(p-type) was thought to be formed. In this p-n junction type sensors, sensing mechanism with reducing gases can be explained by the variation of depletion layer thickness formed in the interface.

  • PDF

A Study on the Test and Installation Standards of the Video Fire Detector (영상화재감지기 시험과 설치기준에 관한 연구)

  • Lee, Jeong-Hyun;Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.1-5
    • /
    • 2016
  • This research performed tests of Video Fire Detector and criteria of installation to make suggestions regarding the criteria that must be reflected in NFSC 203 by comparing the standards of FM Approvals, UL, ISO7240 and NFPA 72. FM Standard related to Video Fire Detector test has been classified as Smoke, Flame type, but the UL Standard has classified only as a Smoke type. This research examined 6 cases of fire phenomenon detection case in ISO 7240 and 3 cases in NFPA 72, respectively. There are 15 items required for the installation standard of a Video Fire Detector and each field standard is presented as a per installation method. To apply a Video Fire Detector, the pertinent items (the definition of term, detector's classification, structure and function among its test item) must be inserted. In addition, 7 items of the fire test, i.e., the sensitivity adjustment, prevent false alarm, ambient temperature test, the effective sensitivity and detection distance and viewing angle, aging test, flood test, must be applied to the actual test. For installation in the field, the operation environment and levels of illumination, and NFSC 203 must be set, and standards relevant to the sound system, indicators' installation distance, etc. need to be inserted.

Method for Preventing Asphyxiation Accidents by a CO2 Extinguishing System on a Ship (선박 내 CO2 소화설비에 의한 질식사고 방지 기법)

  • Ha, Yeon-Chul;Seo, Jung-Kwan;Hwang, Jun-Ho;Im, Kichang;Ryu, Sang-Hoon
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.57-64
    • /
    • 2015
  • Carbon dioxide extinguishing systems are broadly used for onshore and offshore fire accidents because of excellent performance and low cost. However, there is risk with carbon dioxide systems, which have caused many injuries and deaths by suffocation associated with industrial and marine fire protection applications. In this study, a numerical analysis was performed to predict the fire suppression characteristics of a carbon dioxide system in the compressor room of ships. A double protection safety system is suggested to prevent suffocation accidents from carbon dioxide extinguishing systems. Four scenarios were selected to study the variation of the heat release rate, maximum temperature, a $CO_2$ and $O_2$ mole fraction, and fire suppression characteristics with the carbon dioxide system. The importance of proper design is suggested for a ventilation system in the compressor room of ships.

Reflection Signal Analysis for Time Division Multiplexing of Fiber Optic FBG Sensors (광섬유 FBG 센서의 시간 분할 다중화를 위한 반사 신호의 분석)

  • Kim, Geun-Jin;Kwon, Il-Bum;Yoon, Dong-Jin;Hwang, Du-Sun;Chung, Young-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.1
    • /
    • pp.6-12
    • /
    • 2010
  • Fiber optic sensor using fiber Bragg grating(FBG) probes is used for monitoring strain and temperature distributed on the wide surfaces of large structures. In this paper, in order to use many FBG probes in one optical fiber line, we propose a complex multiplexing technology which is composed of two techniques, one is time division multiplexing and another is wavelength division multiplexing. However, we only investigate the characteristics of time division multiplexing because FBG sensors basically can be operated by wavelength division multiplexing. We calculate the optimal reflectivities and the lengthwise location of five FBG probes in serial connection in order to obtain the unique reflected intensities from the FBG probes. We fabricate five FBG probes with the reflectivities of 13%, 16%, 25%, 40% and 80%, which are determined by the theoretical calculation, and observe the signal reflected from each FBG in the time domain from the experiment. There are differences between experimental and theoretical results caused by the signal noise and the differences of reflectivities of FBG probes. But the experimental results shows the reflected signals of five FBG probes which prove the availability of complex multiplexing.

A Study on the contamination measurement of spacecraft components under High Vacuum Environment (고진공하에서의 위성체 부품의 오염측정에 관한 연구)

  • 이상훈;서희준;문귀원;최석원
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.2
    • /
    • pp.87-96
    • /
    • 2002
  • Outgassing from such sources as paints, coatings, adhesives and other non-metallic surfaces can contaminate satellites, especially second surface mirror and optical lens, it cause satellite to fail in own missions. The vacuum bake-out test using high temperature(more than $85 ^{\circ}C$)and high vacuum(less than $5.0{\times}1-^{-3}$ Pa) certify that the components of satellite work properly and can survive and operate in space environment like high vacuum. In the bake-out chamber installed at SITC of KARI, Rotary vacuum pump and Booster pump produce low vacuum of 5.0 Pa, and then two cryopumps produce high vacuum of below $5.0{\times}10^{-3}$ Pa. Also 48 ceramic heaters were provided to simulate high temperature. During the vacuum bake-out test, we detected contaminants using RGA(Residual Gas Analyzer) and measure the outgassing rate of the contaminant using the TQCM(Thermoelectric Quartz Crystal Microbalance). Also, IR/UV Spectrometer and witness plate be used to certify that the components were suitable for the spacecraft. This paper includes the preparation and procedures of the bake-out test for SAR(Solar Array Regulator) and MLI(Multi Layer Insulator), which were the components of the spacecraft. Especially, we discussed the methods and results of the contamination measurement. In the bake-out for SAR, the contamination was measured continuously although it was on the decrease from TQCM results. And RCA established that it is a highly polymerized compound. In the MLI bake-out using RGA and witness plate, we didn't detect any contamination materials.

Low Temperature Structural Tests of a Composite Wing with Room Temperature-Curing Adhesive Bond (상온접합 본딩이 있는 복합재 날개의 저온 구조시험)

  • Ha, Jae Seok;Park, Chan Yik;Lee, Kee Bhum
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.10
    • /
    • pp.928-935
    • /
    • 2015
  • This paper presents low temperature structural tests of a UAV wing which has room temperature-curing adhesive bond. The wing structure is made of carbon fiber reinforced composites, and the skins are bonded to the inner structures (such as ribs and spars) using room temperature-curing adhesive bond. Also, to verify damage tolerance design of the wing structure, barely visible impact damages are intentionally created in the critical areas. The attachment fittings of the wing are fixed in a specially designed chamber which can simulate the low temperature environments of the operating altitudes. The test load is applied by hydraulic actuators which are placed outside the chamber. The structural tests consist of strain survey tests and a durability test for 1-life fatigue load spectrum. During the tests, strains of major parts are measured by strain gauges and FBG sensors. The change of the initial impact damages is also monitored using piezoelectric sensors. The 1-life damage tolerance of the composite structure is verified by the structural tests under the simulated environments.