• Title/Summary/Keyword: 자연증발

Search Result 181, Processing Time 0.03 seconds

Study on Heat Transfer Characteristics of Evaporator with Horizontal Small Diameter Tubes using Natural Refrigerant Propane (자연냉매 프로판을 이용한 수평세관 증발기의 열전달 특성에 관한 연구)

  • Ku, H.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.4
    • /
    • pp.11-16
    • /
    • 2010
  • The evaporation heat transfer characteristics of propane(R-290) in horizontal small diameter tubes were investigated experimentally. The test tubes have inner diameters of 1 mm and 4 mm. Local heat transfer coefficients were measured at heat fluxes of 12, $24\;kW/m^2$, mass fluxes of 150, $300\;kg/m^2s$, and evaporation temperature of $15^{\circ}C$. The experimental results showed that the evaporation heat transfer coefficient of R-290 has an effect on heat flux, mass flux, tube diameter, and vapor quality. The evaporation heat transfer of R-290 has an influenced on nucleate boiling at low quality and convective boiling at high quality. The evaporation heat transfer coefficient of R-290 increases with decreasing inner tube diameter. And the evaporation heat transfer coefficient of R-290 is about 1~3 times higher than that of R-134a.

Simulation of a natural circulation evaporative concentrator (자연순환형 소형 진공증발농축장치 시뮬레이션)

  • Park, Ji-Hoon;Kim, Nae-Hyun;Choi, Young-Min;Oh, Wang-Kyu
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1283-1287
    • /
    • 2009
  • In this study, an analysis was performed on an evaporative steam generator (concentrator), where natural circulation convective boiling occurs on tube-side by condensing hot steam on shell-side. Existing correlations on two-phase pressure drop, boiling or condensation heat transfer were used for the analysis. The effect of number of tubes, tube length, etc. on thermal performance was investigated. Simulation results reveal that steam generation rate increases almost proportionally to the tube length, or number of tubes. It is also shown that water circulation rate decreases as tube length increases.

  • PDF

A Study on the Evaporation of Radioactive Liquid Waste (방사성(放射性) 폐액(廢液)의 자연증발(自然蒸發)에 관한 연구(硏究))

  • Kang, I.S.;Kim, T.K.;Yoo, S.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.1
    • /
    • pp.18-26
    • /
    • 1993
  • The performance of the evaporation facility of low radioactive liquid waste is studied experimentally. The evaporation facility comprises storage pools, feeding pumps, evaporation units with 1,040 sheets of cloth and air handling units. As the results of this study, it is found that the evaporation rate increases as the waste feed rate increases, the relative humidity of induced air decreases, and the air velocity increases. The modified Dalton's evaporation equation derived from experimental data is $E_h=(0.0168+0.0141V){\Delta}H$. The optimum operating conditions of the evaporation facility are waste feed rate of $4.5./hr.m^2$ and air velocity of 1.47m/sec.

  • PDF

Effects of Air Flow Nonuniformity on the Thermal Performance of a Compact Evaporator for Natural Working Fluids (밀집형 자연냉매 증발기의 열성능에 미치는 불균일 공기유동분포의 영향)

  • 박병규;김근오;김무근
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1114-1124
    • /
    • 2001
  • The application of carbon dioxide as an attractive natural working fluid in air cooling and heating system is increasingly important in view of the CFC substitution problem. The thermal performance of compact evaporator was analyzed using section-by-section method. The effects of the two-dimensional nonuniformity of air flow through the evaporator is presented. The detrimental effect of the aid flaw nonuniformity on the thermal performance of the evaporator is found to be significant for many typical applications. It is shown that total heat transfer rate of evaporator using $CO_2$ is higher than that using R134a at the simulation conditions.

  • PDF

The Production and Geochemistry of Evaporite from the Acid Mine Drainage (산성 광산배수로부터 형성되는 증발잔류광물의 생성량과 지구화학)

  • Park Cheon-Young;Cho Kap-Jin;Kim Seoung-Ku
    • Journal of the Korean earth science society
    • /
    • v.26 no.6
    • /
    • pp.524-540
    • /
    • 2005
  • This study has focused on the amount of evaporites and geochemical characteritics of evaporites from the acid mine drainage and on the variation of constituents in acid mine drainage during evaporation. The various colors of evaporites are frequently observed at the rock surfaces contacting acid mine drainage. In order to produce evaporites in the laboratory, acid mine drainages were sampled from the abandoned mine areas (GTa, GTb, GH and GB) and air-dried at room temperature. During the evaporation of acid mine drainages, TDS, EC values and the concentrations of major and minor ions increased, whereas ER and DO values decreased with time. The concentration of Fe increased gradually with evaporation time in the GTb and GB, whereas GH founded in one day but rapidly not detected in the other day after due to removal of Fe by formation-precipitation of amorphous Fe hydroxide. The amounts of the evaporites were produced in amounts of 4 g (GTa), 5 g (GB), 15 g (GH), and 24 g (GTb) from 4 liter of acid mine drainage after 80 days of the evaporation, respectively. In linear analysis from the products with the parameters which are the EC, TDS, salinity, ER, DO and pH contents in field, the determination coefficients were 0.98, 0.99, 0.98, 0.88, 0.89, and 0.25 respectively. If we measure the parameters in field, it would be easy to estimate the amount of evaporites in acid mine drainage. Gypsum and epsomite were identified in all of the evaporites by x-ray powder diffraction studies. Evaporite (GTb) was heated at 52, 65, 70, 95, 150, 250, and 350oC for one hour in electrical furnaces. Gypsum, $CaSO_4\cdot1/2H_2O$ and kieserite were identified in the heated evaporite by XRD. With increased heating temperature, the intensity of the peak at $7.66/AA$ (diagnostic peak of gypsum), the peak at 5.59A ($CaSO_4{\cdot}1/2H_2O)$ and the peak at $4.83{\AA}$ (kieserite) decreased in x-ray diffraction due to dehydration. In the SEM and EDS analysis for the evaporite, gypsum of well-crystallized, radiating cluster of fibrous, acicular, and columnar shapes were observed in all samples. Ca was not detected in the EDS analysis of the flower structures of GTb. Because of that, the evaporite with flower structures is thought to be eposmite.

Assessment of Remote Sensing-based Hydrological Drought Indices (인공위성영상 기반의 수문기상변수를 활용한 수문학적 가뭄지수 개발 및 평가)

  • Sur, Chanyang;Park, Seo-Yeon;Kim, Tae-Woong;Lee, Joo-Heon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.22-22
    • /
    • 2018
  • 본 연구에서는 수문학적 가뭄을 분석하기 위해 두가지 지수를 개발하여 소개하고자 한다. 첫번째는, 물수지식을 기반으로 산정된 Water Budget-based Drought Index(WBDI)로 강우와 증발산의 차이를 이용하여 산정한다. 두 번째는 에너지 수지식을 기반으로 산정된 Energy-based Water Deficit Index(EWDI)로 에너지 수지 기반의 증발산, 태양복사에너지와 토양수분 등을 이용하여 산정한다. 두가지 지수 모두 인공위성 영상 자료를 활용하였다. WBDI 산정을 위한 강수량 자료는 Tropical Rainfall Measuring Mission(TRMM)과 Global Precipitation Mission(GPM)를 활용하였으며, 증발산 자료는 Moderate Resolution Imaging Spectroradiometer (MODIS) 자료를 활용하였다. EWDI 산정에 필요한 입력자료는 모두 MODIS 자료를 활용하였다. 산정된 두 가뭄지수의 수문학적 가뭄 분석을 위해 자연유출지점인 6개 지점을 선정하여 유출량 자료와 비교하였다. 유출량 자료를 활용하여 Error matrix 기법을 적용하여 두 수문학적 가뭄지수의 우리나라에서의 적용성을 파악하였다.

  • PDF

Analysis of Flow Reduction for improving Urban Water Cycle Using SWMM-LID Model (SWMM-LID모델을 이용하여 도시 물순환 개선을 위한 유량 저감 효과 분석)

  • Lee, Tae Woo;Woo, Won Hee;Choi, Gye-woon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.217-217
    • /
    • 2017
  • 물 순환이란 물이 지표면으로부터 증발하거나 바다로부터 증발하여 습한 공기가 기단을 형성한 후 적합한 조건이 형성되면 강수를 초래하는 과정이라고 볼 수 있다. 여기서 강수는 여러 경로 즉, 증발산, 지표흐름, 침투, 침루 등을 통해 다시 순환과정을 거친다. 최근 도시화로 인한 불투수면적의 증가로 기후변화, 홍수지체시간 감소, 첨두 및 유출총량의 증가, 침투능 및 증발산량의 감소 등 자연하천의 유출특성과는 다른 유출특성이 나타나며, 물 순환 체계가 왜곡되어 지하수위는 낮아지고, 하천의 유량은 감소되는 등 하천의 정상적인 기능이 저하되고 있다. 이에 우리나라에서는 환경부 및 국토교통부 등 정부기관과 지방자치단체에서 법과 조례를 제정하여 저영향개발기법 (LID, Low Impact Development)을 적용하도록 권고하고 있으며 신도시 개발사업 시 왜곡된 도시의 물 순환체계를 개선하기 위하여 저영향개발기법을 적용하고 있다. 저영향개발 기법의 정량적인 효과를 검증하기 위해서는 미환경청 (U.S. EPA., United States Environmental Protection Agency)에서 개발한 SWMM모델을 이용하여야 한다. 본 연구에서는 도시화로 인해 왜곡된 물순환체계 개선을 위하여 다양하게 설계된 저영향개발기법의 정량적인 효율을 SWMM 모델을 통해 산정하고, 장기적인 측면에서 물순환 회복에 적합한 저영향개발기법의 배치 최적화를 제안하고자 한다.

  • PDF

Performance Analysis of 2-Stage Compression and 1-Stage Expansion Refrigeration System using Alternative Natural Refrigerants (암모니아 대체 자연냉매를 이용하는 2단압축 1단팽창 냉동시스템의 성능예측)

  • Roh, Geon-Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.42-47
    • /
    • 2012
  • In this paper, alternative natural refrigerant R290(Propane), R600(Butane), R717(Ammonia), R1270(Propylene) for freon refrigerant R22 were used working fluids for 2-stage compression and 1-stage expansion refrigeration system. The operating parameters considered in this study included evaporation temperature, condensation temperature, subcooling degree, superheating degree, mass flow rate ratio of inter-cooler. The main results were summarized as follows : The COP of 2-stage compression and 1-stage expansion refrigeration system increases with the increasing subcooling degree and mass flow rate ration of inter-cooler, but decreases with the increasing evaporating temperature, condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of 2-stage compression and 1-stage expansion refrigeration system using natural refrigerants have an effect on COP of this system. The COP of natural refrigerants was higher than the COP of freon R22 in this study, so points to be considered are the security, the attached facilities for natural refrigerants than COP.

Analysis on the Ventilation Performance of Single-span Tomato Greenhouse with Roof Windows (천창을 설치한 토마토 재배 단동 온실의 환기성능 분석)

  • Nam, Sang-Woon;Kim, Young-Shik;Both, Arend-Jan
    • Journal of Bio-Environment Control
    • /
    • v.20 no.2
    • /
    • pp.78-82
    • /
    • 2011
  • Ventilation rates, inside and outside weather data were measured in a arch-shape single-span plastic greenhouse growing tomatoes. On the roof of the experimental greenhouse, round windows which have a diameter of 0.6 m were installed at intervals of 8m. It showed that the number of air changes in this greenhouse were average 0.17 volumes per minute and in the range of 0.02 to 0.32 volumes per minute. These air changes are insufficient to meet the recommended ventilation rate for commercial greenhouses, and it is estimated that interval of 6 m is appropriate for spring or fall season. For summer season, it is necessary to narrow the space or to enlarge the open area of roof windows. Using the heat balance model, the evapotranspiration coefficients of greenhouse tomatoes were estimated from experimental ventilation data, overall heat transfer and solar radiation. It showed that the evapotranspiration coefficients were average 0.62 and in the 0.39 to 0.85 range. We suggest applying 0.6 as the evapotranspiration coefficient in design of ventilation for the single-span tomato greenhouses.

Water cycle of an urbanized catchment, taking the case of Tancheon (탄천을 통해 살펴본 도시유역의 물순환)

  • Yoo, Sanghyun;Paik, Kyungrock
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.123-123
    • /
    • 2022
  • 자연유역 내에 도시가 자리잡고 발달해 나가면 유역의 특성에 급격한 변화를 가져온다. 이러한 변화로 인해 도시유역은 자연유역과는 상이한 수문학적 특성을 나타낸다. 그 동안 도시수문학의 주된 관심사는 도심지 홍수예방, 상수관망 등에 주어졌고, 장기적인 관점에서 도시유역의 물순환에 대한 정량화는 별로 다루어지지 않았다. 이 연구에서는 비교적 최근에 급격하게 도시화가 이루어진 탄천 유역에 대해 도시유역의 장기적인 물순환에 대해 정량화하고 자연유역과의 차이를 분석하고자 한다. 강수량, 유출량, 증발산량, 상수공급량, 하수처리량 등의 가용한 자료를 동원하여 탄천 유역의 물수지 분석을 수행하였다. 탄천유역은 유역 외부에서 상수를 공급받고 사용된 용수는 하수처리시설을 통해 하천으로 방류되고 있으며 이로 인해 유출 특성이 자연유역과 많은 차이를 보이고 있다.

  • PDF