• Title/Summary/Keyword: 자연방사선

Search Result 215, Processing Time 0.026 seconds

A Calculation of Effective Dose Equivalent from Data of Environmental Monitoring around the Karlsruhe Nuclear Research Center (Karlsruhe 원자력연구소 주변의 환경방사능 측정자료로부터 실효선량당량계산)

  • Lee, Chang-Woo;Lee, Jeong-Ho;Wicke, A.
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.75-85
    • /
    • 1990
  • The dose calculations were carried out using environmental montoring data around Karlsruhe Nuclear Research Center(KfK). Ingestion of plant foods was the most important pathway, and the K-40 and Pb-210 natural radioisotopes in food were the most effective radiation source to man. The dose received from artificial nuclides were mostly emitted by gamma irradiation of Cs-134 and Cs-137 deposited on the ground. The effective dose equivalent in the KfK environment was far less than the dose equivalent limit recommended by ICRP.

  • PDF

Electronic Circuit System of a Portable Rl Gauge for Compaction Control (성토다짐용 휴대용 Rl 계기의 전자회로 시스템)

  • 김기준
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.4 no.2
    • /
    • pp.32-38
    • /
    • 1999
  • In this study, an objection is to develop a electronic circuit of a gauage using radioisotope for compaction control to be needed at public works The developed gauage makes use of radioisotope with the activity exempted from domestic atomic law and consists of measuring circuits for gamma-rays and thermal neutrons, a high voltage supply unit and a microprocessor. To obtain meaningful numbers of pulse counts, parallel five and tow circuits are provided for gamma-rays and thermal neutrons, respectively. Also, to minimize effects of natural environmental radiation and electrical noise, circuits are electrostatically shielded and pulses made by ripples are eliminated by taking frequency of high voltage supplied to the circuit and pulse height of ripples into consideration One-chip microprocessor is applied to process various counts, results are stored, Enough and meaningful numbers of pulses are counted with the prototype gauage for compaction control.

  • PDF

Management of an Open Comminuted Fracture of the Metacarpus using Circular External Skeletal Fixation in a Korean Water Deer (Hydropotes inermis argyopus) (고라니에서 발생한 손허리뼈 개방 복합골절의 원형 외부골격고정법 적용)

  • Heo, Su-Young;Jeong, Seongmok;Lee, Haebeom
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.359-362
    • /
    • 2015
  • A Korean water deer was rescued after being hit by a motor vehicle. Clinical and radiographic examination revealed a grade III open fracture of the right metacarpus with severe soft tissue injury. The water deer underwent closed reduction of the fracture, which was stabilized by the application of the Ilizarov method of 4-ring circular external skeletal fixation (CESF) as a minimally invasive technique. The water deer was successfully released into the wild. CESF was advantageous for the stabilization of open comminuted fracture and the management of a severely contaminated wound in a Korean water deer. CESF can be used successfully in wild deer with good tolerance and minimal complications.

Counting Strategies in Radioactivity Measurement for the Monitoring and Screening (방사능 존재확인과 정량분석시 최적화된 측정시간의 결정을 위한 계측전략)

  • Seo, Kyung-Won
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.2
    • /
    • pp.65-74
    • /
    • 1998
  • One of the important things in low level radioactivity measurement is determination of the optimized counting time. Counting strategy has to be established, in order to count the radioactivity of the sample by condition of optimized measurement. There were three kinds of counting strategies in this report ; about fixed time, about fixed count, to compared sample, background, and reference level. The best of them was satisfied rendition to give about condition of instrument and process, as an example, efficiency of detector, counter capacity, maximum and average background count rate of counter, reference level and limit of derision and detection, etc. Therefore, we can decide the optimized counting time in the screening and monitoring. And we can save the time for courting the sample of course the data of count will be counted by optimized accuracy finally, in rountine measurement of radioactivity these strategies will be used available.

  • PDF

Transgastric Endoscopic Cholecystectomy in a Dog : Natural Orifice Transluminal Endoscopic Surgery (개에서 내시경을 이용한 경위장관 담낭절제술 1예 : 자연개구부 내시경수술)

  • Jeong, Seong-Mok;Kim, Young-Ill;Lee, Jae-Yeon;Jee, Hyun-Chul;Park, Ji-Young;Park, Jong-Heon;Kim, Ji-Yeon;Lee, Sang-Il;Kim, Myung-Cheol;Shin, Sang-Tae;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.24 no.3
    • /
    • pp.315-319
    • /
    • 2007
  • Transgastric endoscopic cholecystectomy was successfully accomplished in a 1-year-old, 15 kg, female, mongrel dog. Single-working channel flexible gastric endoscope was used with the aid of one abdominal laparoscopic port. Gastrotomy was performed using endoscopic needle knife at the ventral antral region. Through the gastric incision endoscope was advanced and retroflexed for the visualization of gallbladder. For the better exposure of surgical field, gentle traction was applied at the fundus of the gallbladder using laparoscopic grasping forceps. Cystic duct and artery was ligated using endoclips. After transecting the duct and artery, gallbladder was dissected using endoscopic coagulating grasping forceps and needle knife. Resected gallbladder was retrieved through the mouth and gastric incision site was sutured using endoclips. There was no evidence of bile leakage or stomach leakage on postoperative day (POD) 3. On POD 16, gastric endoscopy and laparoscopy was performed. Gastric endoscopy revealed complete adhesion of incision site. The content of the peritoneum appeared healthy, with no sign of infection, bile staining, or organ injury. The omentum was adhered over resected gallbladder fossa and the serosal surface of gastrotomy site. This is the first report of NOTES cholecystectomy in the dog and provides new concept of cholecystectomy of the dog.

Radiological Projection for Diagnosis of Shoulder Subluxation in Patients with Post-Stroke Hemiplegia (편마비 환자에서의 견관절 아탈구 진단에 유용한 촬영법)

  • Cho, Kwang-Ho;Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.253-259
    • /
    • 2009
  • Purpose : The purpose of this study was to find out useful radiological projection of shoulder subluxation in patients with post-stroke hemiplegia. Methods : A total of 33 patients with post-stroke hemiplegia were included(20 men and 13 women, mean age 62.3 years) and having the subluxed shoulder over one finger breath. The shoulder subluxation was determined as the ratio of the radiographic vertical and horizontal distance. The vertical distance was determined by measuring the distance between the most inferolateral point of the acromion and the central point of the humeral head. The horizontal distance was determined by measuring the distance between the central point of the glenoid fossa and the central point of the humeral head. To measure of the shoulder subluxation, the shoulder AP, axial and transthoracic lateral projections were taken on both affected and unaffected shoulders. We analyzed the difference of subluxation distance by t-test. Results : When patients was in sitting position, the average time of being shoulder subluxation was 123 second. There was significant difference between supine($49.90{\pm}13.6\;mm$) and sitting position($60.72{\pm}16.3\;mm$) in the vertical distance of shoulder anterior-posterior projection. Also, there was significant difference on transthoracic lateral projections, Affected $35.92{\pm}6.2\;mm$, Unaffected $28.76{\pm}5.4\;mm$. But in case of shoulder axial projection(supine position), there was no significant difference (Unaffected and affected was $23.01{\pm}9.0\;mm$, $22.45{\pm}8.2\;mm$ each). Conclusion : Radiological projection of shoulder subluxation has diagnostic value when it goes after check out the process of subluxation through finger breadth test. For this, patients must be in sitting and shoulder neutral position about 2 minutes. In addition, Shoulder anterior-posterior and transthoracic projection were significant to diagnose subluxation. But in axial projection, there wasn't meaningful differences.

  • PDF

Measurement of shoulder motion fraction and motion ratio (견관절 운동 분율의 측정)

  • Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.57-62
    • /
    • 2006
  • Purpose : This study was to understand about the measurement of shoulder motion fraction and motion ratio. We proposed the radiological criterior of glenohumeral and scapulothoracic movement ratio. Materials and Methods : We measured the motion fraction of the glenohumeral and scapulothoracic movement using CR(computed radiological system) of arm elevation at neutral, 90 degree, full elevation. Central ray was $15^{\circ},\;19^{\circ},\;22^{\circ}$ to the cephald for the parallel scapular spine, and the tilting of torso was external oblique $40^{\circ},\;36^{\circ},\;22^{\circ}$ for perpendicular to glenohumeral surface. Healthful donor of 100 was divided 5 groups by age(20, 30, 40, 50, 60). The angle of glenohumeral motion and scapulothoracic motion could be taken from gross arm angle and radiological arm angle. We acquired 3 images at neutral, $90^{\circ}$ and full elevation position and measured radiographic angle of glenoheumeral, scapulothoracic movement respectively. Results : While the arm elevation was $90^{\circ}$, the shoulder motion fraction was 1.22(M), 1.70(W) in right arm and 1.31, 1.54 in left. In full elevation, Right arm fraction was 1.63, 1.84, and left was 1.57, 1.32. In right dominant arm(78%), $90^{\circ} and Full motion fraction was 1.58, 1.43, in left(22%) 1.82, 1.94. In generation 20, $90^{\circ} and Full motion fraction was 1.56, 1.52, 30' was 1.82, 1.43, 40' was 1.23, 1.16, 50' was 1.80, 1.28, 60' was 1.24, 1.75. There was not significantly by gender, dominant arm and age. Conclusion : The criterior of motion fraction was useful reference for clinical dignosis the shoulder instability.

  • PDF

FRACTURE RESISTANCE OF THE THREE TYPES OF UNDERMINED CAVITY FILLED WITH COMPOSITE RESIN (복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구)

  • Choi, Hoon-Soo;Shin, Dong-Hoon
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.177-183
    • /
    • 2008
  • It was reported that esthetic composite resin restoration reinforces the strength of remaining tooth structure with preserving the natural tooth structure. However, it is unknown how much the strength would be recovered. The purpose of this study was to compare the fracture resistance of three types of undermined cavity filled with composite resin with that of non-cavitated natural tooth. Forty sound upper molars were allocated randomly into four groups of 10 teeth. After flattening occlusal enamel. undermined cavities were prepared in thirty teeth to make three types of specimens with various thickness of occlusal structure (Group $1{\sim}3$). All the cavity have the 5 mm width mesio-distally and 7 mm depth bucco-lingually. Another natural 10 teeth (Group 4) were used as a control group. Teeth in group 1 have remaining occlusal structure about 1 mm thickness, which was composed of mainly enamel and small amount of dentin. In Group 2, remained thickness was about 1.5 mm, including 0.5 mm thickness dentin. In Group 3, thickness was about 2.0 mm, including 1 mm thickness dentin. Every effort was made to keep the remaining dentin thickness about 0.5 mm from the pulp space in cavitated groups. All the thickness was evaluated with radiographic Length Analyzer program. After acid etching with 37% phosphoric acid, one-bottle adhesive (Single $Bond^{TM}$, 3M/ESPE, USA) was applied following the manufacturer's recommendation and cavities were incrementally filled with hybrid composite resin (Filtek $Z-250^{TM}$, 3M/ESPE, USA). Teeth were stored in distilled water for one day at room temperature, after then, they were finished and polished with Sof-Lex system. All specimens were embedded in acrylic resin and static load was applied to the specimens with a 3 mm diameter stainless steel rod in an Universal testing machine and cross-head speed was 1 mm/min. Maximum load in case of fracture was recorded for each specimen. The data were statistically analyzed using one-way analysis of variance (ANOVA) and a Tukey test at the 95% confidence level. The results were as follows: 1. Fracture resistance of the undermined cavity filled with composite resin was about 75% of the natural tooth. 2. No significant difference on fracture loads of composite resin restoration was found among the three types of cavitated groups. Within the limits of this study, it can be concluded the fracture resistance of the undermined cavity filled with composite resin was lower than that of natural teeth, however remaining tooth structure may be supported and saved by the reinforcement with adhesive restoration, even of that portion consists of mainly enamel and a little dentin structure.

  • PDF

FRACTURE RESISTANCE OF THE THREE TYPES OF UNDERMINED CAVITY FILLED WITH COMPOSITE RESIN (복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구)

  • Choi, Hoon-Soo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.177-183
    • /
    • 2008
  • It was reported that esthetic composite resin restoration reinforces the strength of remaining tooth structure with preserving the natural tooth structure. However, it is unknown how much the strength would be recovered. The purpose of this study was to compare the fracture resistance of three types of undermined cavity filled with composite resin with that of non-cavitated natural tooth. Forty sound upper molars were allocated randomly into four groups of 10 teeth. After flattening occlusal enamel, undermined cavities were prepared in thirty teeth to make three types of specimens with various thickness of occlusal structure (Group $1{\sim}3$). All the cavity have the 5 mm width mesiodistally and 7 mm depth bucco-lingually. Another natural 10 teeth (Group 4) were used as a control group. Teeth in group 1 have remaining occlusal structure about 1 mm thickness, which was composed of mainly enamel and small amount of dentin. In Group 2, remained thickness was about 1.5 mm, including 0.5 mm thickness dentin. In Group 3, thickness was about 2.0 mm, including 1 mm thickness dentin. Every effort was made to keep the remaining dentin thickness about 0.5 mm from the pulp space in cavitated groups. All the thickness was evaluated with radiographic Length Analyzer program. After acid etching with 37% phosphoric acid, one-bottle adhesive (Single $Bond^{TM}$, 3M/ESPE, USA) was applied following the manufacturer's recommendation and cavities were incrementally filled with hybrid composite resin (Filtek $Z-250^{TM}$, 3M/ESPE, USA). Teeth were stored in distilled water for one day at room temperature, after then, they were finished and polished with Sof-Lex system. All specimens were embedded in acrylic resin and static load was applied to the specimens with a 3 mm diameter stainless steel rod in an Universal testing machine and cross-head speed was 1 mm/min. Maximum load in case of fracture was recorded for each specimen. The data were statistically analyzed using one-way analysis of variance (ANOVA) and a Tukey test at the 95% confidence level. The results were as follows: 1. Fracture resistance of the undermined cavity filled with composite resin was about 75% of the natural tooth. 2. No significant difference in fracture loads of composite resin restoration was found among the three types of cavitated groups. Within the limits of this study, it can be concluded the fracture resistance of the undermined cavity filled with composite resin was lower than that of natural teeth, however remaining tooth structure may be supported and saved by the reinforcement with adhesive restoration, even if that portion consists of mainly enamel and a little dentin structure.

Batch Scale Storage of Sprouting Foods by Irradiation Combined with Natural Low Temperature - I. Storage of Potatoes - (방사선(放射線) 조사(照射)와 자연저온(自然低溫)에 의한 발아식품(發芽食品)의 Batch Scale 저장(貯藏)에 관(關)한 연구(硏究) - 제(第) 1 보(報) : 감자의 저장(貯藏) -)

  • Cho, Han-Ok;Byun, Myung-Woo;Kwon, Joong-Ho;Yang, Ho-Sook;Lee, Chul-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.355-363
    • /
    • 1982
  • In order to develop the commercial storage method of potatoes by irradiation combined with natural low temperature, storage room($450{\times}650{\times}250cm$; year round temperature change, $2-17^{\circ}C;\;70-85%\;R.H.$) on a batch scale followed by irradiation with optimum dose level. Irish cobbler and Shimabara were 100% sprouted after 3 months storage in control, whereas in 15 Krad irradiated group, sprouting was completely inhibited at Irish cobbler for 9 months storage, and at Shimabara for 12 months. The extent of loss due to rot attack after 9 months storage was 6% in control, 6-8% in 10-15 Krad irradiated group at Irish cobbler and weight loss was 16.5% in control, 5.1-5.6% in irradiated group, whereas rotting rate of Shimabara after 12 months storage was 100% in control, 15% in irradiated group and the weight loss of its was 12.6% in control, $7.3{\sim}7.4%$ in irradiated group. The moisture content in whole storage period of two varieties were $72{\sim}82%$ without remarkable changes. The total sugar and ascorbic acid contents were slightly decreased according to the dose increase and elapse of storage period, whereas reducing sugar content was increased. Irish cobbler was 90% marketable after 9 months storage and 85% in Shimabara after 12 months storage.

  • PDF