• Title/Summary/Keyword: 자세 획득

Search Result 334, Processing Time 0.027 seconds

Jungian Interpretation of Creation Myths Focused on Egg Symbolism (분석심리학적 관점으로 고찰한 창조신화 : '알(卵)'의 상징성 중심으로)

  • Jin-Sook Kim
    • Sim-seong Yeon-gu
    • /
    • v.27 no.1_2
    • /
    • pp.28-70
    • /
    • 2012
  • In Jungian psychology, creation myths regard as the story of unconscious and preconscious processes(projection of archaic identity) which describe not necessary the origin of our cosmos, but the origin of man's conscious awareness of the world. Therefore projections have nothing to do with matter itself but experience of one's own unconscious. Jung emphasizes importance to understand projection in individual's conscious experience rather than in philosophical doctrine. The purpose of this thesis is to explore unconscious process of creation myths with egg symbolism in clinical cases to present universal feature of Cosmic/alchemical egg. Psychologically, creation myths retold when human mind needs new order. Depending on the attitude of ego, it can be sudden expansion of consciousness or contamination of ego by unconscious. In this study, 'chaos(messa confusa)' in creation myths as archaic identity, experience of uroboros or infant, and nigredo state in alchemy. 'Separation of primordial parents' as beginning of consciousness refers to separatio operation in alchemical process. 'Light' as attainment of consciousness. Discussion of psychological meaning of egg starts with amplification which include the concept of cosmic/alchemical/philosophical egg. Egg symbolism in this study refers to emergence of egg, tapas/brooding of egg, and separation of egg. Emergence of egg as a state of preconscious totality, psychic wholeness conceived as the thing which came before the rise of ego consciousness. Discussion of conceptssuch as Shiva bindu, hiranyagharba, germ of gold, Tathāgatagarbha follows. 'Tapas/brooding of egg' as concentration of all psychic energy into one point for self reflection. Discussion includes The I Ching Hexagram 61, image of brooding egg identified with inner truth, Wonhyo's concept of jikwansasang, and Gnostic idea of Ennoia, introverted act of thinking, as well as the concept of 'Night Sea Journey'. 'Separation or hatching of egg' regarded as the idea of sudden illumination, Phanes, the shining God, and "sun-point," in alchemy. Birth of fledgling as birth of new personality. As a conclusion, psychological meaning of cosmic egg/creation myths is the story of separating from 'Not-I'(unconscious, object, undifferentiated) to 'I'(ego, subject, differentiated) which shares the same meaning as individuation process.

Study the Analysis of Comparison with AROI and MROI Mode in Gated Cardiac Blood Pool Scan (게이트심장혈액풀 스캔에서 자동 관심영역 설정과 수동 관심영역 설정 모드의 비교 분석에 관한 고찰)

  • Kim, Jung-Yul;Kang, Chun-Koo;Kim, Yung-Jae;Park, Hoon-Hee;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.222-228
    • /
    • 2008
  • Purpose: The objectives of this study were to compare the left ventricle ejection fraction (LVEF) from gated cardiac blood pool scan (GCBP) for analysis auto-drawing region of interest mode (AROI) and manual-drawing region of interest mode (MROI), respectively. To evaluation the relationships between values produced by both ROI modes. Materials and Methods: Gated cardiac blood pool scan using in vivo method Tc-99m Red Blood Cell were performed for 33 patients (mean age: $53.2{\pm}13.2\;y$) with objective of chemotherapy using single head gamma camera (ADAC Laboratories, Milpitas, CA). Left ventricular ejection fraction was automatically and manually measured, respectively. Results: There was significant difference statistically between AROI and MROI ($LVEF^{AROI}$: $71.4{\pm}12.4%$ vs. $LVEF^{MROI}$: $65.8{\pm}5.9%$, p=0.003). Intra-observer agreements in AROI was higher than MROI ($\gamma^{AROI}=0.964$, Cronbach's $\alpha^{AROI}=0.986$ vs. $\gamma^{MROI}=0.793$, Cronbach's $\alpha^{MROI}=0.911$), either. Additionally, there was no significant difference statistically at best septal view (${\Delta}LVEF^{BSV}=0.7{\pm}2.3%$, p=0.233), however statistically significant difference was found at badly separated septal view (${\Delta}LVEF=10.9{\pm}11.4%$, p=0.001). Moreover, Intra-observer agreements in best septal view was higher than badly separated septal view ($\gamma^{BSV}=0.939$, Cronbach's $\alpha^{BSV}=0.978$; $\gamma=0.948$, Cronbach's $\alpha=0.981$ at AROI, $\gamma^{BSV}=0.836$, Cronbach's $\alpha^{BSV}=0.936$; $\gamma=0.748$, Cronbach's $\alpha=0.888$ at MROI). Conclusion: When best septal view was acquired, LVEF by AROI and MROI indicated not different. Comparing Intra-observer agreements with AROI and MROI, the AROI tended to show higher. Therefore, it is considered that the AROI than MROI is valuable in reproducibility and objective when ROI analysis by acquire left ventricular of best septal view.

  • PDF

The evaluation of usefulness of Electronic Portal Imaging Device(EPID) (Electronic Portal Imaging Device(EPID)의 유용성 평가)

  • Lee, Yang-Hoon;Kim, Bo-Kyoum;Jung, Chi-Hoon;Lee, Je-Hee;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.19-31
    • /
    • 2005
  • Purpose : To supply the information of EPID system and to analyze the possibility of substitution EPID for film dosimetry. Materials & Methods : With amorphous silicon(aSi) type EPID and liquid filled lonization chamber(LC) type EPID, the reproducibility according to focus detector distance(FDD) change and gantry rotation was analyzed, and also the possible range of image acquisition was analyzed with Alderson Rando phantom. The resolution and the contrast of aSi type EPID image were analyzed through Las Vegas phantom and water phantom. DMLC image was analyzed with X-Omat V film and EPID to see wether it could be applied to the qualify assurance(QA) of IMRT. Results : The reproducibility of FDD position was within 1mm, but the reproducibility of gantry rotation was ${\pm}2,\;{\pm}3mm$ respectively. The resolution and the contrast of EPID image were affected by dose rate, image acquisition time, image acquisition method and frame number. According to the possible range of image acquisition of EPID, it is verified that the EPID is easier to use than film. There is no difference between X-Omat V film and EPID images for the QA of IMRT. Conclusion : Through various evaluation, we could obtain lots of useful information about the EPID. Because the EPID has digital data, also we found that the EPID is more useful than film dosimerty for the periodical Qualify Assurance of IMRT. Especially when it is difficult to do point dose measurement with diode or ionization chamber, the EPID could be very useful substitute. And we found that the diode and ionization chamber are difficult to evaluate the sliding window images of IMRT, but the EPID was more useful to do it.

  • PDF

Evaluation on Usefulness of Applying Body-fix to Liver Cancer Patient in Tomotherapy (간암환자의 토모치료시 Body-fix 사용유무에 따른 유용성 평가)

  • Oh, Byeong-Cheon;Choi, Tae-Gu;Kim, Gi-Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.11-18
    • /
    • 2010
  • Purpose: In every time radiation therapy set up errors occur because internal anatomical organs move due to breathing and change of patient's position. These errors may affect the change of dose distribution between target area and normal structure. This study investigates the usefulness of body-fix in clinical treatment. Materials and Methods: Among 55~60 aged male patients who has hepatocellular carcinoma in area of liver's couinaud classification, we chose 10 patients and divided two groups by using body-fix or not. When applying body-fix, we maintained a vacuum of 80 mbar pressure by using vacuum pump (Medical intelligence, Germany). Patients had free breathing with supine position. After working to fuse and consist MV-CT (megavoltage computed tomography) with KV-CT (kilovoltage computed tomography) obtained by 5 times treatments, we compared and analyzed set up errors occurred to (Right to Left, RL) of X axis, (Anterioposterio, AP) of Z axis, (Cranicoudal, CC) of Y axis. Results: Average Set up errors through image fusion showed that group A moved $0.3{\pm}1.1\;mm$ (Cranicoudal, CC), $-1.1{\pm}0.7\;mm$ (Right to Left, RL), $-0.2{\pm}0.7\;mm$ (Anterioposterio, AP) and group B moved $0.62{\pm}1.94\;mm$ (Cranicoudal, CC), $-3.62{\pm}1.5\;mm$ (Right to Left, RL), $-0.22{\pm}1.2\;mm$ (Anterioposterio, AP). Deviations of X, Y and Z axis directions by applying body-fix indicated that maximum X axis was 5.5 mm, Y axis was 19.8 mm and Z axis was 3.2 mm. In relation to analysis of error directions, consistency doesn't exist for every patient but by using body-fix showed that the result of stable aspect in spite of changes of everyday's patient position and breathing. Conclusion: Using body-fix for liver cancer patient is considered effectively for tomotherapy. Because deviations between group A and B exist but they were stable and regular.

  • PDF

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

Analysis on Relation between Rehabilitation Training Movement and Muscle Activation using Weighted Association Rule Discovery (가중연관규칙 탐사를 이용한 재활훈련운동과 근육 활성의 연관성 분석)

  • Lee, Ah-Reum;Piao, Youn-Jun;Kwon, Tae-Kyu;Kim, Jung-Ja
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.6
    • /
    • pp.7-17
    • /
    • 2009
  • The precise analysis of exercise data for designing an effective rehabilitation system is very important as a feedback for planing the next exercising step. Many subjective and reliable research outcomes that were obtained by analysis and evaluation for the human motor ability by various methods of biomechanical experiments have been introduced. Most of them include quantitative analysis based on basic statistical methods, which are not practical enough for application to real clinical problems. In this situation, data mining technology can be a promising approach for clinical decision support system by discovering meaningful hidden rules and patterns from large volume of data obtained from the problem domain. In this research, in order to find relational rules between posture training type and muscle activation pattern, we investigated an application of the WAR(Weishted Association Rule) to the biomechanical data obtained mainly for evaluation of postural control ability. The discovered rules can be used as a quantitative prior knowledge for expert's decision making for rehabilitation plan. The discovered rules can be used as a more qualitative and useful priori knowledge for the rehabilitation and clinical expert's decision-making, and as a index for planning an optimal rehabilitation exercise model for a patient.

The Study of Effectiveness in a Modified Rib Oblique Projection View Using a Chest Phantom (흉부팬텀을 이용한 변형된 늑골 사방향 검사의 유용성에 관한 연구)

  • Um, Ki-Tae;Lee, Min-Su;Kang, Sung-Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.525-532
    • /
    • 2018
  • This study is filmed by applying the axial angle variation of the X-ray tube instead of the patient's position change during the perimetric examination of the ribs. A Reference image with the rib oblique examination using a chest phantom and experimental images applied with a six-phase variation in the axial angle by increasing $5^{\circ}$ tube angle each from $5^{\circ}{\sim}30^{\circ}$ from the vertical incident direction of the chest phantom to the right horizontal axis were obtained. For the quantitative comparative evaluation of the images, SNR and CNR were calculated for regions of interest in the experimental images based on the reference image. Also, the left-right rib ratio in the reference image and the left-right rib ratio in the experimental images are measured and compared. As a result of the study, the experimental images with a tube angle of $25^{\circ}$ were best shown in the measurements of the SNR, CNR and left-right rib ratio compared to the reference image with a standard examination method. The modified rib examinations will consider useful, if it is difficult to maintain the patient's examination position.

3D Face Modeling based on 3D Morphable Shape Model (3D 변형가능 형상 모델 기반 3D 얼굴 모델링)

  • Jang, Yong-Suk;Kim, Boo-Gyoun;Cho, Seong-Won;Chung, Sun-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.1
    • /
    • pp.212-227
    • /
    • 2008
  • Since 3D face can be rotated freely in 3D space and illumination effects can be modeled properly, 3D face modeling Is more precise and realistic in face pose, illumination, and expression than 2D face modeling. Thus, 3D modeling is necessitated much in face recognition, game, avatar, and etc. In this paper, we propose a 3D face modeling method based on 3D morphable shape modeling. The proposed 3D modeling method first constructs a 3D morphable shape model out of 3D face scan data obtained using a 3D scanner Next, the proposed method extracts and matches feature points of the face from 2D image sequence containing a face to be modeled, and then estimates 3D vertex coordinates of the feature points using a factorization based SfM technique. Then, the proposed method obtains a 3D shape model of the face to be modeled by fitting the 3D vertices to the constructed 3D morphable shape model. Also, the proposed method makes a cylindrical texture map using 2D face image sequence. Finally, the proposed method builds a 3D face model by rendering the 3D face shape model with the cylindrical texture map. Through building processes of 3D face model by the proposed method, it is shown that the proposed method is relatively easy, fast and precise than the previous 3D face model methods.

Virtual Reality Based Welding Training Simulator (가상현실 기반 용접 훈련 시뮬레이터)

  • Jo, Dong-Sik;Kim, Yong-Wan;Yang, Ung-Yeon;Lee, Gun-A.;Choi, Jin-Sung;Kim, Ki-Hong
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.49-49
    • /
    • 2010
  • 용접은 산업계의 기계 조립 및 접합을 위한 공정의 주요한 작업으로 조선, 중공업, 건설 등 산업현장에서 사람에 의한 수동적인 작업으로 대부분 수행된다. 이러한 용접 작업을 수행하는 용접 기술자는 산업 현장 훈련원과 직업 교육 학교에서 양성되지만 용접 훈련 과정은 실습 초보자에게 위험하고, 장시간 교육하기에 어려울 뿐 아니라 재료 낭비, 의사 소통의 한계, 즉석 결과 평가의 한계, 공간부족 등 다양한 문제가 있다. 그러므로, 안전하고 반복적인 실습 환경 제공하고 장시간 및 다수 교육참여 지원 등이 가능한 시스템을 구축하여 숙련된 우수 인력 조기 확보와 훈련 비용을 절감할 필요가 있다. 본 논문에서는 실제와 동일한 상호작용을 제공할 뿐만 아니라 고품질로 훈련 환경을 가시화하여 용접 상황을 동일하게 모사하는 가상 현실 기반 용접 훈련 시뮬레이터를 제시한다. 이 시스템은 용접의 형상과 환경의 고품질 가시화, 경험 DB를 통한 용접의 비드 형상 데이터 획득, 용접 토치를 이용하는 사용자 상호작용, 용접 훈련 결과 평가 및 최적 작업 가이드, 용접 콘텐츠 저작, 다양한 용접 훈련을 가시화하는 하드웨어 플랫폼으로 구성된다. 고품질 가상 용접 가시화는 경험 DB 기반 비드 형상 데이터와 신경회로망을 이용한 비드 형상 예측을 통해 실시간 비드 표현이 이루어지며 쉐이더 기반 고품질 모재 및 비드 표현, 아크 불꽃 효과 표현을 포함한다. 사용자 상호작용은 현장 작업 도구와 일치된 토치 인터페이스와 위치추적을 이용하여 토치의 작업각, 진행각, 속도, 거리 등을 반영할 수 있으며 진동과 소리 등 용접 훈련의 사실적 상호작용도 재현하였다. 용접 훈련 평가 및 최적 작업 가이드는 훈련자의 용접속도, 거리, 각도 등의 사용자 작업 결과를 그래픽으로 표현하고, 애니메이션을 통한 훈련 자세를 추후 분석할 수 있도록 하였고, 가상토치, 기준선, 수치계기 등을 이용한 최적 작업 훈련 가이드 제시하였다. 훈련 콘텐츠 저작은 메뉴UI 기반으로 용접의 전류, 전압 등의 조건과 상황을 선택하도록 제시하였고, 하드웨어 플랫폼은 워크벤치형 입체 디스플레이 방식으로 용접 환경을 가시화하였고, 위, 정면, 아래보기 등 다양한 용접 자세 변경을 지원 할 수 있도록 구축하였다. 이러한 가상현실 기반 훈련 시뮬레이터는 아크열 발생에 따른 장시간 훈련의 어려움을 극복할 수 있고, 다양한 실습 환경을 바꾸어 가며 반복적인 훈련이 가능하고, 실 재료를 사용하지 않아 재료의 낭비를 줄일 수 있는 환경 친화적인 안전하고 효율적인 훈련 실습 환경을 제공할 수 있다.

  • PDF

High-Quality Depth Map Generation of Humans in Monocular Videos (단안 영상에서 인간 오브젝트의 고품질 깊이 정보 생성 방법)

  • Lee, Jungjin;Lee, Sangwoo;Park, Jongjin;Noh, Junyong
    • Journal of the Korea Computer Graphics Society
    • /
    • v.20 no.2
    • /
    • pp.1-11
    • /
    • 2014
  • The quality of 2D-to-3D conversion depends on the accuracy of the assigned depth to scene objects. Manual depth painting for given objects is labor intensive as each frame is painted. Specifically, a human is one of the most challenging objects for a high-quality conversion, as a human body is an articulated figure and has many degrees of freedom (DOF). In addition, various styles of clothes, accessories, and hair create a very complex silhouette around the 2D human object. We propose an efficient method to estimate visually pleasing depths of a human at every frame in a monocular video. First, a 3D template model is matched to a person in a monocular video with a small number of specified user correspondences. Our pose estimation with sequential joint angular constraints reproduces a various range of human motions (i.e., spine bending) by allowing the utilization of a fully skinned 3D model with a large number of joints and DOFs. The initial depth of the 2D object in the video is assigned from the matched results, and then propagated toward areas where the depth is missing to produce a complete depth map. For the effective handling of the complex silhouettes and appearances, we introduce a partial depth propagation method based on color segmentation to ensure the detail of the results. We compared the result and depth maps painted by experienced artists. The comparison shows that our method produces viable depth maps of humans in monocular videos efficiently.