• Title/Summary/Keyword: 자세재현성

Search Result 94, Processing Time 0.022 seconds

The evaluation of usefulness of Electronic Portal Imaging Device(EPID) (Electronic Portal Imaging Device(EPID)의 유용성 평가)

  • Lee, Yang-Hoon;Kim, Bo-Kyoum;Jung, Chi-Hoon;Lee, Je-Hee;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.19-31
    • /
    • 2005
  • Purpose : To supply the information of EPID system and to analyze the possibility of substitution EPID for film dosimetry. Materials & Methods : With amorphous silicon(aSi) type EPID and liquid filled lonization chamber(LC) type EPID, the reproducibility according to focus detector distance(FDD) change and gantry rotation was analyzed, and also the possible range of image acquisition was analyzed with Alderson Rando phantom. The resolution and the contrast of aSi type EPID image were analyzed through Las Vegas phantom and water phantom. DMLC image was analyzed with X-Omat V film and EPID to see wether it could be applied to the qualify assurance(QA) of IMRT. Results : The reproducibility of FDD position was within 1mm, but the reproducibility of gantry rotation was ${\pm}2,\;{\pm}3mm$ respectively. The resolution and the contrast of EPID image were affected by dose rate, image acquisition time, image acquisition method and frame number. According to the possible range of image acquisition of EPID, it is verified that the EPID is easier to use than film. There is no difference between X-Omat V film and EPID images for the QA of IMRT. Conclusion : Through various evaluation, we could obtain lots of useful information about the EPID. Because the EPID has digital data, also we found that the EPID is more useful than film dosimerty for the periodical Qualify Assurance of IMRT. Especially when it is difficult to do point dose measurement with diode or ionization chamber, the EPID could be very useful substitute. And we found that the diode and ionization chamber are difficult to evaluate the sliding window images of IMRT, but the EPID was more useful to do it.

  • PDF

Evaluation on the Usefulness of 6DoF Couch in V-MAT on Patients with Long length of Target (표적의 길이가 긴 환자의 용적회전변조 방사선치료 시 6DoF Couch의 유용성 평가)

  • Choi, Young Se;Park, Hyo Kuk;Kim, Se Young;Kim, Joo Ho;Lee, Sang Kyoo;Yoon, Jong Won;Cho, Jung Heui
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.53-64
    • /
    • 2017
  • Purpose: To evaluate the usefulness of the $HexaPOD^{TM}$ evo RT system(6DoF couch) and the tendency of dose difference according to size of rotational direction error for volumetric rotational modulated radiotherapy(V-MAT) in patients with long target lengths. Therefore, it is suggested to recommend the need for rotational error correction. Materials and Methods: Ten patients with Esophagus cancer or Breast cancer including SCL treated with HexaPOD 6DoF(Six-Degree of Freedom) couch were included in this study. 6DoF couch was used to measure the difference in dose according to the rotation error in the directions of Rx(pitch), Ry(roll), and Rz(yaw). Each rotation error was applied. Positioning variation on x, y and z axis was verified and random variations were made by 6DoF couch with positioning variation. Modified DQA is conducted and point dose and gamma value are analyzed and compared. In addition, after applying the rotation error every $1^{\circ}$ to treatment plans of each target with a diameter of 3 cm, 5, 10, 15, and 20 cm respectively, gamma passing rate is being monitored by its aspect of change according to types and sizes of the target length and rotation error. Results: Mean error of the point dose and Gamma passing rate when the position variation was applied were $2.50{\pm}1.11%$ and $84.1{\pm}7.39%$ in the Rx direction, $2.36{\pm}1.16%$, and $81.0{\pm}8.49%$ in the Ry, $2.35{\pm}1.10%$ and $84.4{\pm}6.99%$ in the Rz direction, respectively. As a result of analysis on gamma passing rate according to types and sizes of the target length and rotation error, the gamma passing rate tended to decrease with increasing rotation error in the Rx and Rz directions except Ry direction. In particular, the lowest gamma passing rate (74.2 %) was in the case of $2.5^{\circ}$ rotation error in Rz direction of the target of 10 cm. Conclusion: The correction of the rotational error is needed for volumetric modulated radiotherapy of the treatment area with a long target length, and the use of 6DoF couch will improve the reproducibility of the patient position and the quality of the treatment.

  • PDF

Study on 3D Printer Production of Auxiliary Device for Upper Limb for Medical Imaging Test (의료영상 검사를 위한 상지 보조기구의 3D 프린터 제작 연구)

  • Kim, Hyeong-Gyun;Yoon, Jae-Ho;Choi, Seong-Dae
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.389-394
    • /
    • 2015
  • There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cases of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are $120{\times}150{\times}190mm$, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be recorded per patient for traceability and dual examination.

The evaluation of image guide system in case of rectal cancer (직장암 치료시 영상유도 시스템의 유용성 평가)

  • Jang, Sewuk;Ahn, Seungkwon;Lee, Sangkyoo;Kim, Jooho;Lee, Wonju;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.85-92
    • /
    • 2017
  • purpose: Image Guide System offers therapy precise, especially Intensity Modulated Radiation Therapy. However, organs at pelvis have variation and uncertainties each therapy. it brings IG system for verifying patient's position. In this study, analysis the variation at pelvis during rectal cancer radiation therapy. Moreover design the patient re-setup technique and apply to patients. Material and Method: 40 rectal cancer patient who have radiation therapy. The 530 image which acquired from IG system are analyzed. The bone structure, bladder, gas in the rectum, small bowel, soft tissue, weigh loss are evaluated by the criterion. The criterion are classified by best, good, bad and figure out the ratio with count. The re-setup proceed in case of one or over the two get the bad criterion and figure out the ratio of re-setup results: The ideal of therapy ratio is 19.2 % each criterion. And the good for therapy ratio is 54.9 %, the cases of bad for therapy is 25.8 %. The bad cases are have therapy after re-setup with post process. conclusion: Each pre-treatment image that acquired IG system has different results despite of same patients. The 25.8 % need to re-setup in order to unsuitable therapy. It is implies that the IG system is necessary establishing precise treatment plan like IMRT especially rectal cancer.

  • PDF

Applicability of Different E-book Production Methods for Books No Longer in Print (절판(絶版)서적의 전자책 제작방법에 따른 효용성 비교 연구)

  • Kim, So-Ra;Kim, Dong-Eon
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.4
    • /
    • pp.157-168
    • /
    • 2017
  • This thesis will select one of the books that went out of print, and republish it using the ePub and PDF format to observe the effective and economic method to republish it as an e-book. Conclusively, e-book in PDF format was advantageous over ePub production. The ePub has limitations of electronically publishing the books went out of print prior to 21st century when storing the original text was not common, as well as book with complex layouts. The PDF format was able to capture and recreate the sensitivity that can only be presented by vintage books, also adding to the cultural value. To publish PDF e-books, the foremost requirement is to prepare a standardized system that allows comprehensive browsing of the current status of the book, and also creating an environment for copyrighted publishers to more actively publish e-books by diversifying the distribution platforms and properly allocating the profit generated by use of the copyright. This thesis provides a simulation of e-book publications, for small and medium size publishers and writers who are hesitant to publish e-books, to take more aggressive approach in entering the business.

Property of Wireless Clip-type Pulsimeter by Using a Hall Device and a Permanent Magnet (영구자석과 홀소자를 이용한 무선 집게형 맥진기 특성 연구)

  • Yoon, Woo-Sung;Ji, Jong-Ok;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.6
    • /
    • pp.179-185
    • /
    • 2014
  • The existing USB connection type of the clip-type pulsmeter equipped with a Hall sensor and a permanent magnet does not have any error or malfunction to measure the pulse wave. The property of the wireless networking system communicating the pulse wave data through the wireless LAN communication by combination USB with Ethernet and Ethernet to Wi-Fi converting system instead of existing USB connection method was investigated. There are exited that the patient needs to stay at close site of the desktop PC without USB connector and the wireless transfer and receiver networking system has pulse wave measurement SW to receive the pulse wave data. Thus it is expected that the study becomes helpful to measure and transfer the exact pulse wave of the patient in a comfortable pose at close range.

The evaluation of dose of TSEI with TLD and diode dector of the uterine cervix cancer (열형광선량계와 반도체검출기를 이용한 전신피부전자선조사의 선량평가)

  • Je Young Wan;Na Keyung Su;Yoon IL Kyu;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2005
  • Purpose : To evaluate radiation dose and accuracy with TLD and diode detector when treat total skin with electron beam. Materials and Methods : Using Stanford Technique, we treated patient with Mycosis Fungoides. 6 MeV electron beam of LINAC was used and the SSD was 300 cm. Also, acrylic speller(0.8 cm) was used. The patient position was 6 types and the gantry angle was 64, 90 and $116^{\circ}$. The patient's skin dose and the output were detected 5 to 6 times with TLD and diode. Result : The deviations of dose detected with TLD from tumor dose were CA $+\;6\%$, thigh $+\;8\%$, umbilicus $+\;4\%$, calf $-\;8\%$, vertex $-\;74.4\%$, deep axillae $-\;10.2\%$, anus and testis $-\;87\%$, sole $-\;86\%$ and nails shielded with 4mm lead $+4\%$. The deviations of dose detected with diode were $-4.5\%{\sim}+5\%$ at the patient center and $-1.1\%{\sim}+1\%$ at the speller. Conclusion : The deviation of total skin dose was $+\;8\%{\sim}-\;8\%$ and that deviation was within the acceptable range(${\pm}\;10\%$). The boost dose was irradiated for the low dose areas(vertex, anus, sole). The electron beam output detected at the sootier was stable. It is thought that the deviation of dose at patient center detected with diode was induced by detection point and patient position.

  • PDF

Evaluation of the Efficiency of the Foxtail Millet Vacuum Cushion in Skin Cancer Radiation Treatment (자체 제작한 Foxtail Millet Vacuum Cushion의 광자선 피부암 치료 시 유용성 검증)

  • Choi, Shin-Cheol;Lee, Kyung-Jae;Jung, Sung-Min;Oh, Tae-Seong;Park, Jong-Il;Shin, Hyun-Kyo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.189-196
    • /
    • 2012
  • Purpose: The sufficiency of skin dose and the reemergence of patient set-up position to the success of skin cancer radiation treatment is a very important element. But the conventional methods to increase the skin dose were used to vacuum cushion, bolus and water tank have several weak points. For this reason, we producted Foxtail Millet Vacuum Cushion and evaluated the efficiency of the Foxtail Millet Vacuum Cushion in skin cancer Radiation treatment. Materials and Methods: We measured absolute dose for 3 materials (Foxtail Millet Vacuum Cushion, bolus and solid water phantom) and compared each dose distribution. We irradiated 6 MV 100 MU photon radiation to every material of 1 cm, 2 cm, 3 cm thickness at three times. We measured absolute dose and compared dose distribution. Finally we inspected the CT simulation and radiation therapy planing using the Foxtail Millet Vacuum Cushion. Results: Absolute dose of Foxtail Millet Vacuum Cushion was similar to absolute dose of bolus and solid water phantom's result in each thickness. it Showed only the difference of 0.1~0.2% between each material. Also the same result in dose distribution comparison. About 97% of the dose distribution was within the margin of error in the prescribed ranges ($100{\pm}3%$), and achieved the enough skin dose (Gross Tumor Volume dose : $100{\pm}5%$) in radiation therapy planing. Conclusion: We evaluated important fact that Foxtail Millet Vacuum Cushion is no shortage of time to replace the soft tissue equivalent material and normal vacuum cushion at the low energy radiation transmittance. Foxtail Millet Vacuum Cushion can simultaneously achieve the enough skin dose in radiation therapy planing with maintaining normal vacuum cushion' function. Therefore as above We think that Foxtail Millet Vacuum Cushion is very useful in skin cancer radiation treatment.

  • PDF

Cephalometric study on head posture according to the Classification of Malocclusion (부정교합 분류에 따른 두경부 위치의 두부방사선 계측학적 연구)

  • Hwang, Chung-Ju;Kim, Suk-Hyun;Kil, Jae-Kyung
    • The korean journal of orthodontics
    • /
    • v.27 no.2
    • /
    • pp.221-230
    • /
    • 1997
  • It has been known that head posture may influence directly and/or indirectly the growth and development of craniofacial morphology and can also be influenced by the funtional demand of physiologic activity. It was reported that facial morphology has close relationships with hyoid bone position and head posture. In many previous studies, Natural Head Posture(NHP) was guided, and also it was shown that NHP has high degree of reproducibility. Otherwise, There was few study about the relationship of head posture, with routine cephalometric film which is used for clinical orthodontic purpose. In this study, according to the Wits and ANB of initial cephalometric film which was taken with vertical pendulum as representative of true vertical reference line. We classified the subjects which is comprised of 60 adult female patients into Class I, II, III (Cl I, II, III)and we tried to find out the correlation of head posture and hyoid bone position according to the classification of malocclusion. As a result of our research, we found the followigs. 1. In comparison of vertical position of hyoid bone relative to the cranial base. the position of hyoid bone of Cl III was lower than that of Cl II. 2. In comparison of anteriorpostes or position of hyoid bone, relative to the cervical column. The position of hyoid bone of Cl III was more anterior than that of a II 3. in comparison of vertical position of hyoid bone relative to mandible. There was no significant correlation aumoug the groups of malocclusion. 4. ANB and Wits showed no significant correlation with hyoid bone position. 5. The relative extension of head, which was noted in Cl II, showed negative with Sum, ANB. 6. In Cl II and Cl III, Post to Ant facial height showed positive correlation with NSL/VER.

  • PDF

Accuracy and radiation exposure from image-guidance in Tomotherapy Hi-Art System (토모테라피 Hi-Art System의 영상유도 정확성 평가와 환자 피폭에 관한 연구)

  • Jang, Jae-Uk;Lim, Hyun-Soo;Han, Man-Seok;Kim, Yong-Kyun;Jeon, Min-Cheol
    • Journal of Digital Convergence
    • /
    • v.11 no.10
    • /
    • pp.577-584
    • /
    • 2013
  • IGRT(Image Guided Radiation Therapy) in radiation therapy is a very useful technique in order to increase setup of patient and position reproducibility. Tomotherapy can increase accuracy of setup to take IGRT by MVCT, but it be for verified accuracy of Image guided, and MVCT occurs the exposure of patient. Through this study, IGRT accuracy of Tomotherapy is very accurate within 1.0mm. When MVCT using Tomotherapy phantom for QA, QC be taken, exposure dose is Fine(2mm Slice thickness) 3cGy, Normal(4mm Slice thickness) 1.5cGy, Corse(6mmSlice thickness) 1.0cGy. Measurement value of spatial resolution using AAPM CT performance phantom did't cause a big difference. As a result, ability of IGRT in Tomotherapy is very accurate. While obtaining image for IGRT, we should minimize expose range because patient's be exposed to radiation. We should make an effort to do accurate radiation therapy to minimize exposure of patient by selecting the appropriate thickness of MVCT depending on patient's body and treat area.