• 제목/요약/키워드: 자성체

Search Result 257, Processing Time 0.021 seconds

초음파 리니어액츄에이터 및 전동기

  • 장석명
    • 전기의세계
    • /
    • v.39 no.9
    • /
    • pp.27-34
    • /
    • 1990
  • 초음파 구동장치는 기존 액츄에이터나 전동기의 우너리나 구조와는 전혀 다른 형태로, 여자전류를 흘리는 권선과 자성체로 이루어진 자기회로등의 기존 전동기에서의 필수 구성요소가 전혀 없이도 필요한 구동 토오크를 발생시키는 가장 구조가 간단한 형태이다. 즉, 압전재료에 교류전원을 인가하면 진동하는 성질을 이용하는 것으로 압전재료를 고정자로 하고 회전자 또는 이동자(리니어 액츄에이터의 경우)를 접촉시켜 놓고 고정자에 초음파 전원을 인가하면 상호간의 마찰에 의하여 힘을 받게 되어 회전자/이동자가 운동하게 되는 원리를 이용한 것이다.

  • PDF

A Study of Magnetic Properties for Recycling Laser Printer Developer Roller (재활용 Laser Printer 현상기 Roller의 자성체 특성 연구)

  • Cho, Hyun-Seob
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.11a
    • /
    • pp.67-70
    • /
    • 2007
  • Developer roller of laser printer cartridge made with magnetic substance and density of magnetic flux was decreased with the elapse of a year. Owing to this reason, quality of printing was decreased with decreasing of magnetic flux. This study investigated about the elapse of a year of magnetic substance and possible about usage of recycling production.

  • PDF

Flaw Detection in a Conductor Using Sensor Head of Amorphous Wire (비정질 와이어를 센서헤드로 이용한 금속의 미세결함 검출)

  • Kim, Y.H.;Shin, K.H.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.5
    • /
    • pp.174-178
    • /
    • 2002
  • Ac magnetic field was changed in the vicinity of a flaw because of the distribution of eddy current within a conductor, when the magnetic field was applied to a conductor having a flaw. The flaw detection was performed by using Co-based amorphous wire sensor head. The wire has almost 0 magneto-striction and high permeability. An comparative uniform magnetic field was applied to a 1㎜ thick copper plate and a 25㎛ thick aluminum sheet conductor using spiral typed coil. The size of the coil has 40㎜$\times$40㎜ outer width and 8㎜$\times$8㎜ inner width. The copper plate and the aluminum sheet has 0.5㎜ and 0.1㎜ wide gap, respectively. The frequency range of applied field was 100㎑∼600㎑. The induced voltage difference of 2.5㎷ was obtained in the maximum voltage and minimum one measured across the gap of the 1mm thick conductor. In the case of aluminum sheet, 0.4㎷ was obtained. From this results, the effectiveness of Co-based amorphous wire was confirmed in the ECT technique.

Effects of magnetic ion exchange resin with PACI coagulation on removal of natural organic matter and MF fouling (자성체 이온교환 수지와 PACI 응집에 의한 국내 주요 수계 내 자연유기물 제거 특성 및 막오염 저감 효과)

  • Choi, Yang Hun;Jeong, Young Mi;Kim, Young Sam;Lee, Seung Ryul;Kweon, Ji Hyang;Kwon, Soon Buhm
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.131-140
    • /
    • 2008
  • The application of magnetic ion exchange resin($MIEX^{(R)}$) is effective for natural organic matter(NOM) removal and for control of the formation of disinfection byproducts(DBPs). NOM removal is also enhanced by adding $MIEX^{(R)}$ with coagulant such as polyaluminium chloride(PACl) in conventional drinking water treatment systems. In the application of $MIEX^{(R)}$, it is important to understand changes of NOM characteristics such as hydrophobicity and molecular weight distributions with $MIEX^{(R)}$ or $MIEX^{(R)}$+coagulant treatment.To observe characteristics of NOM by treatment with $MIEX^{(R)}$ or $MIEX^{(R)}$+coagulant, four major drinking water sources were employed. Results showed that the addition of $MIEX^{(R)}$ to coagulation significantly reduced the amount of coagulant required for the optimum removal of dissolved organic matter(DOC) and turbidity in the all four waters. The DOC removal was also increased approximately 20%, compared to coagulant treatment alone. The process with $MIEX^{(R)}$ and coagulant showed that complementary removal of hydrophobic and hydrophilic fraction of DOC. The combined processes preferentially removed the fractions of intermediate (3,000-10,000 Da) and low (< 500 Da) molecular weight. The microfiltration test showed that membrane cake resistance was decreased for waters with flocs from $MIEX^{(R)}$+coagulant. A porous layer was formed to $MIEX^{(R)}$ on the membrane surface and the layer consequently inhibited settling of coagulant flocs, which could act on a foulant.

Inductive Micro Thin Film Sensor for Metallic Surface Crack Detection (금속 표면결함 검출용 자기유도 마이크로 박막 센서)

  • Kim, Ki-Hyeon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.5
    • /
    • pp.395-400
    • /
    • 2008
  • Alternating magnetic field was used for detection of surface flaws on nonmagnetic and magnetic metallic specimens. The nondestructive sensor probe was composed of the planar coil with inductive magnetic thin film yoke as a sensing component and a single straight typed exciting coil. The planar inductive coil sensor with magnetic yoke was fabricated by sputtering, electroplating, dry etching and photolithography process. The alternative currents with the range of 0.1A to 1.0A (0.7 MHz to 1.8 MHz) were applied to the exciting coil. The specimens were prepared with the slit shaped artificial surface flaws (minimum depth and width; 0.5 mm) on metallic plate (Al; nonmagnetic metal and FeC; magnetic metal). The detected signal for the positions and shapes of surface flaws on specimens were obtained with high sensitivity and high signal to ratio. The measured output signals by the non-contacted scanning on surface of FeC specimen with micron-sized crack were converted to the images of the flaws. And these results were compared with the optical images, respectively.

Effect of Orientation on Magnetic Tape Properties (도포형 자기기록 매체의 자성층에서 자성체의 배향거동과 배향상태에 따른 Tape 특성의 변화)

  • 김상문;김태옥;신학기;여운성
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.6
    • /
    • pp.314-320
    • /
    • 1997
  • We have observed the orientation behavior of acicular iron oxides in magnetic layer of the particular magnetic tape after magnetic paint was coated on polyester film. As results of the static orientation, orientation of iron oxides come to the maximum at the front and the back of orientation magnets, but it was a litter lower at the back than at the front, and it slowly decreases and come to the constant level after passing through the orientation magnets. In case of edge portion to be futher away from center in the coated film, the orientation of iron oxides in magnetic layer come to worse than that of the center. We think it is owing to the shape and the magnetic magnitude of orientation magnets. The results of the dynamic orientation are as follows. As the orientation of iron oxides in the particulated magnetic tape is higher, the output properties of tape come to better than ever. And the orientation of iron oxides can be changed by drying condition, as result, the output properties of tape can be also. Therefore we think the considrations of the design of orientation magnets and the control of drying condition are needed to improve output properties of the particulated magnetic tape.

  • PDF

Microwave Absorbing Properties of Fe-Si-Al Alloy Flaky Powder-Rubber Composites (Fe-Si-Al 합금 분말 · 고무 복합 자성체의 전파 흡수 특성)

  • Lee Kyung-Sub;Yoon Yeo-Choon;Choi Gwang-Bo;Kim Sung-Soo;Lee Jun-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.2 s.93
    • /
    • pp.228-234
    • /
    • 2005
  • A magnetic composite as noise absorber of quasi-microwave band was developed. The Fe-Si-Al alloy powder were forged by attrition mill to get flaky shape. The magnetic composite sheet was fabricated in which powders are dispersed in polymer and aligned in the direction perpendicular to electromagnetic wave propagation. The permittivity of magnetic composite is increased as forging time increasing, while the permeability is decreased slightly. The maximum attenuation peak of reflection loss is shifted to lower fiequency range as milling time increasing, and the value of maximum attenuation peak is to get smaller gradually. From these result, we could designed a noise absorber sheet (t=1.0 mm) for quasi-microwave band, which is impedance matched at 1.4 GHz with respect to -8.2 dB reflection 1055.

Design and Electromagnetic Characteristics of Planar Transformer (평면변압기의 설계와 전자기적 특성)

  • Kim, Hyun-Sik;Lee, Hae-Yeon;Kim, Jong-Ryung;Oh, Young-Woo
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.3
    • /
    • pp.109-116
    • /
    • 2002
  • We designed the flyback planar transformer, which had 8 W capacity, with 70 V input voltage and 8.2 V output voltage for the establishment of design method and the confirmation of application possibility. The numerical value of inductance measured under the switching frequency of 120 kHz was 1650 $\mu$H, which was the inductance efficiency of'85∼87% against theoretical value. The A.C. resistance of primary and secondary coil was 4.2 Ω and 0.25 Ω respectively, On the other hand, the quality factor for each wound numbers showed quite a high value of 158 and 75 respectively. And the Coupling Factor was 0.96∼0.97 under 120 kHz switching frequency. The inductance rapidly increased as the thickness of the core plane increased until it became 1.4 mm but under the thickness more than 1.4 mm, there was no substantial change. Therefore, the critical value of the plane thickness of core was 1.4 mm. And the shape of the output wave of the planar transformer at 70V input voltage was a stable square wave.

Route Tracking of Moving Magnetic Sensor Objects and Data Processing Module in a Wireless Sensor Network (무선 센서 네트워크에서의 자기센서기반 이동경로 추적과 데이터 처리 모듈)

  • Kim, Hong-Kyu;Moon, Seung-Jin
    • The KIPS Transactions:PartC
    • /
    • v.14C no.1 s.111
    • /
    • pp.105-114
    • /
    • 2007
  • In sensor network processing environments, current location tracking methods have problems in accuracy on receiving the transmitted data and pinpointing the exact locations depending on the applied methods, and also have limitations on decision making and monitoring the situations because of the lack of considering context-awareness. In order to overcome such limitations, we proposed a method which utilized context-awareness in a data processing module which tracks a location of the magnetic object(Magnetic Line Tracer) and controlled introspection data based on magnetic sensor. Also, in order to prove its effectiveness we have built a wireless sensor network test-bed and conducted various location tracking experiments of line tracer using the data and resulted in processing of context-aware data. Using the new data, we have analyzed the effectiveness of the proposed method for locating the information database entries and for controlling the route of line tracer depending on context-awareness.

Separation Between Soil Particles and Magnetic Beads by Magnetic Force (자력을 이용한 토양입자와 마이크로자성체의 분리 연구)

  • So, Hyung-Suk;Shin, Hyun-Chul;Yoo, Yeong-Seok
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.76-80
    • /
    • 2005
  • It was evaluated whether magnetic beads able to add the functionality of environment purification can be employed in processing soil pollutants. In this study, the micro scale magnetic beads containing carboxyl groups were mixed with water and the soil $(<0.025{\cal}mm) filtered through a sieve, and then it was agitated before isolating the magnetic substances by the use of outer magnetic force. The factors considered at this step were the ratio of soil to magnetic beads, ratio of soil to water, size of the tube where the reaction occur, and intensity of the magnetic force. From the separation experiment between soil and magnetic beads, it was concluded that the magnetic beads and water quantity have an impact on the degree of separation, yet the size of the tube and magnetic force does not have a considerable effect upon that in this small-scaled experiment. Through this experiment, the reaction conditions were optimized to achieve $90\~100\%$ of separation. Therefore, it was concluded that when the functionalized magnetic beads is introduced to environmental processing, it is able to be adopted to the soil processing as well as the water processing.