• Title/Summary/Keyword: 자동 계측

Search Result 368, Processing Time 0.031 seconds

The Differences of Anthropometric and Polysomnographic Characteristics Between the Positional and Non-positional Obstructive Sleep Apnea Syndrome (체위 의존성 및 체위 비의존성 폐쇄성 수면 무호흡증후군의 신체계측인자 및 수면구조의 차이)

  • Park, Hye-Jung;Shin, Kyeong-Cheol;Lee, Choong-Kee;Chung, Jin-Hong;Lee, Kwan-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.6
    • /
    • pp.956-963
    • /
    • 2000
  • Backgrounds : Obstructive sleep apnea syndrome(OSA) can divided into two groups, positional(PP) and non-positional(NPP) obstructive sleep apnea syndrome, according to the body position while sleeping. In this study, we evaluated the differences of anthropometric data and polysomnographic recordings between the two types of sleep apnea syndrome. Materials : Fifty patients with OSA were divided two groups by Cartwright's criteria. The supine respiratory disturbance index (RDI) was at least two times higher than the lateral RDI in the PP group, and the supine RDI was less than twice the lateral RDI in the NPP group. This patients underwent standardized polysomnographic recordings. The anthropometric data and polysomnographic data were analyzed, statistically. Results : Of all 50 patients, 30% were found to be positional OSA. BMI was significantly higher in the PP group(p<0.05). Total sleep time was significantly longer in the PP group (350.6$\pm$28.2min, 333.3$\pm$46.0min, (p<0.05). Sleep efficiency was high in the PP group(89.6$\pm$6.4%, 85.6$\pm$9.9%, p<0.05). Deep sleep was significantly higher and light sleep was lower in the PP group than in the NPP group but no difference was observed in REM sleep between the two groups. Apnea index(AI) and RDI were significantly lower( 17.0$\pm$10.6, 28.5$\pm$13.3, p<0.05) and mean arterial oxygen saturation was higher in the PP group(92.7$\pm$1.8%. p<0.05) than in the NPP group. Conclusion : Body position during sleep has a profound effect on the frequency and severity of breathing abnormalities in OSA patients. A polysomnographic evaluation for suspected OSA patients must include monitoring of the body position. Breathing function in OSA patients can be improved by controlling their obesity and through postural therapy.

  • PDF

The Clinical Usefulness Measurement of the Whole Body Percent Fat Calculated by the Part Bone Mineral Density Measurement (부분골밀도 측정을 통해 산출되는 체지방률의 임상적 유용성에 대한 평가)

  • Kang, Young-Eun;Kim, Eun-Hye;Kim, Ho-Sung;Choi, Jong-Sook;Choi, Woo-Jun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.3-9
    • /
    • 2011
  • Purpose: Generally dual energy X-ray absorptiometry has been used for the purpose of evaluation of osteoporosis and treatment. Recently the interest of obesity came to be high and body percent fat test is increasing. Existing measure of body fat have to scan the whole body can be evaluated, but only lumbar spine and hip measurements was assumed to be whole body fat as well as improving the software. It tries to check whether the part measured value not being whole body measurement has the validity or not compared with the value calculated with the method that it is different, it forgives through a correlation with a (BIA) and (BMI). Materials and Methods: In 2010, the body percent fat was measured among the examinee coming to the Asan Medical Center public health care center from March till August against 90 females more than 40 years old through (DXA) and BIA. BMI utilized the value which wrote an hight and weight measured through the body measuring instrument in the examinee information and is automatically calculated. In addition, it classified as the low weight ($13-18.5kg/m^2$), normal ($18.5-25kg/m^2$), and corpulence ($25-30kg/m^2$) based on BMI and so that it could check whether there was the difference according to the weight or not BMI and BIA and correlation between DXA were analyzed in each group. The statistical program for the analysis used SPSS 12.0. Results: The comparison of DXA at 3 which it divides into the low weight and normal and corpulence groups and BIA did not show the difference noted statistically in all groups and the between group comparison was exposed to do not have a meaning. The body percent fat measured by the correlation analysis result DXA at the state that it doesn't divide into the group showed the high correlation (r=0.908, p0.01) noted statistically compared with BMI and showed the high correlation noted statistically in a comparison with BIA (r=0.927, p0.01). Conclusion: It confirmed that the whole body percent fat presumed from the part bone density measurement showed the excel correlation compared with BIA and BMI and information is high. There is still no clear standard about the presumed whole body percent fat and it is difficult to evaluate the fat evaluation by the bone mineral density measurement. However, it is determined that the information offering which is more objective through the comparative study with the body percent fat which is very efficient and in that it can obtain till the information about a fat as well as diagnosis of the osteoporosis through the bone density checkup is measured by the afterward telegraph bone density checkup and is clinically useful is possible.

  • PDF

Optimization Design of Damping Devices for a Super-Tall Building Using Computational Platform (전산플랫폼을 이용한 초고층구조물의 감쇠장치 최적화 설계)

  • Joung, Bo-Ra;Lee, Sang-Hyun;Chung, Lan;Choi, Hyun-Chul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.2
    • /
    • pp.145-152
    • /
    • 2015
  • In the study, the effects of damping devices on damping ratio increase and wind-load reduction were investigated based on the computational platform, which is one of the parametric modeling methods. The computational platform helps the designers or engineers to evaluate the efficacy of the numerous alternative structural systems for irregular Super-Tall building, which is crucial in determining the capacity and the number of the supplemental damping devices for adding the required damping ratios to the building. The inherent damping ratio was estimated based on the related domestic and foreign researches conducted by using real wind-load records. Two types of damping devices were considered: One is inter-story installation type passive control devices and the other is mass type active control devices. The supplemental damping ratio due to the damping devices was calculated by means of equivalent static analysis using an equation suggested by FEMA. The optimal design of the damping devices was conducted by using the computational platform. The structural element quantity reduction effect resulting from the installation of the damping devices could be simply assessed by proposing a wind-load reduction factor, and the effectiveness of the proposed method was verified by a numerical example of a 455m high-rise building. The comparison between roof displacement and the story shear forces by the nonlinear time history analysis and the proposed method indicated that the proposed method could simply but approximately estimate the effects of the supplemental damping devices on the roof displacement and the member force reduction.

Study on the histomorphometry of guided bone regeneration using automated image analysis system (자동 영상분석 계기를 이용한 골 유도재생능력의 분석에 관한 조직계측학적 연구)

  • Kim, T.I.;Ku, Y.;Rhyu, I.C.;Chung, C.P.;Han, S.B.;Choi, S.M.;Son, S.H.
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.3
    • /
    • pp.771-778
    • /
    • 1996
  • The assessment of alveolar bone changes on dental radiographs to indicate progression of periodontal diseases or healing response to therapy is routine procedure. However, the diagnostic accuracy in detecting small alveolar bone changes is very limited. Recently, guided bone regeneration therapy is popular, but the quantification of new bone is somewhat difficult with conventional evaluation method. To quantificate the amount of new bone, various evaluating methods have been introduced including histomorphometry, radiomorphometry, biochemical analysis, X-ray probe microanalysis, scanning electron microscope backscatter method. In this study, guided bone regeneration using resorbable membrane with & without PDGF-BB is quatificated through histomorphmetry to evaluate the efficacy of histomorphometric analysis. 4 beagle dogs and 8 Sprague-Dawley rats were selected as experimental animals. In beagle dog experiment, $4{\times}4mm$ Class II defects were created in maxillary both second premolars, and biodegradable membrane containing PDGF-BB(experimental group) were covered over one defect, and same membrane without PDGF-BB(control group) were covered over the other defect. At 2 weeks, 5 weeks after surgery, each beagle dogs were sacrificed, and the tissues were treated by undecalcified fixation. In Sprague-Dawley rat experiment, 5mm round defect were created in temporal bone, the same membranes were covered on the defects. At 1 week, 2 weeks after surgery, each rats were sacrificed, and undecalcified fixation were taken. After grinding tissue specimen, we analyse them histomorphometrically using image analysis system. In beagle dog 2 weeks specimens, new bone formation area were $0.03123mm^2$ in experimental group,and $0.03012mm^2$ in control group. At 5 weeks specimens, $0.15324mm^2$ in experimental group, and $0.09123mm^2$ in control group. In Sprague-Dawley rat specimens, new bone fomation area were $0.20448mm^2$ in 1 week experimental group, $0.03604mm^2$ in 1 week control group. At 2 weeks specimens, $0.46349mm^2$ in experimental group, $0.17741mm^2$ in control group. The results indicated that histomorphometric analysis of new bone formation using image analysis system is very effective quantification method to evaluate the efficacy of treatment modalities.

  • PDF

Development of Android-Based Photogrammetric Unmanned Aerial Vehicle System (안드로이드 기반 무인항공 사진측량 시스템 개발)

  • Park, Jinwoo;Shin, Dongyoon;Choi, Chuluong;Jeong, Hohyun
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.3
    • /
    • pp.215-226
    • /
    • 2015
  • Normally, aero photography using UAV uses about 430 MHz bandwidth radio frequency (RF) modem and navigates and remotely controls through the connection between UAV and ground control system. When using the exhausting method, it has communication range of 1-2 km with frequent cross line and since wireless communication sends information using radio wave as a carrier, it has 10 mW of signal strength limitation which gave restraints on life my distance communication. The purpose of research is to use communication technologies such as long-term evolution (LTE) of smart camera, Bluetooth, Wi-Fi and other communication modules and cameras that can transfer data to design and develop automatic shooting system that acquires images to UAV at the necessary locations. We conclude that the android based UAV filming and communication module system can not only film images with just one smart camera but also connects UAV system and ground control system together and also able to obtain real-time 3D location information and 3D position information using UAV system, GPS, a gyroscope, an accelerometer, and magnetic measuring sensor which will allow us to use real-time position of the UAV and correction work through aerial triangulation.

Change of Groundwater-Streamflow Interaction according to Groundwater ion in a Green House Land (비닐하우스 지역의 지하수 양수에 따른 지하수-하천수 상호 유동 변화 분석)

  • Kim, Nam Won;Lee, Jeong Woo;Chung, Il Moon;Kim, Chang Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.10
    • /
    • pp.1051-1067
    • /
    • 2012
  • Increased use of water curtain facilities to keep green house warm during winter cultivation has been known to cause excessive groundwater ion which might lead to decline of groundwater level, resulting in streamflow depletion. Therefore it is required to quantitatively assess the effects of groundwater ion on the streamflow depletion such as magnitude and extent. The objective of this study is to assess the change of stream-aquifer interaction according to groundwater ion near stream. To this end, a green house cultivation land in Sooha-ri, Sindun-myun, Icheon-si, Gyonggi-do was selected as a field experimental site, and monitoring wells were established near and within stream to observe the water level and temperature changes over a long period of time. From the observed water level and temperature data, it was found that the river reach of interest changed to a losing stream pattern during the winter cultivation season due to groundwater level decline around pumping wells near the stream. The continuous exchange rates between stream and aquifer were estimated by plugging the observed water level data series into the experimental relation between head difference and exchange rate, showing the streamflow depletion by 16% of the groundwater pumping rate in Feb, 2011.

Study on Development of Patient Effective Dose Calculation Program of Nuclear Medicine Examination (핵의학검사의 환자 유효선량 계산 프로그램 제작에 관한 연구)

  • Seon, Jong-Ryul;Gil, Jong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.657-665
    • /
    • 2017
  • The aim of this study was to develop and distribute a dedicated program that can easily calculate the effective dose of a patient undergoing nuclear medicine examinations, and assist in the study of dose of nuclear medicine examinations and information disclosure. The program produced a database of the effective dose per unit activity administered (mSv/MBq) of the radiopharmaceuticals listed in ICRP 80, 106 Report and the fourth addendum, was designed through Microsoft Visual Basic (In Excel) to take the effect of 5 different (Area, Clark, Solomon(=Fried), Webster, Young) of pediatric dose calculation methods and 7 different body surface area calculation methods. The program calculates the effective dose (mSv) when the age, radionuclide, substance, and amount injected in the human body is inputted. In pediatric cases, when the age is entered, the pediatric method is activated and the pediatric method to be applied can be selected. When the BSA (Body Surface Area) formula is selected in the pediatric calculation method, a selection window for selecting the body surface area calculation method is activated. When the adult dose is input, the infant dose and the effective dose (mSv) are calculated automatically. The patient effective dose calculation program of the nuclear medicine examinations produced in this study is meaningful as a tool for calculating the internal exposure dose of the human body that is most likely to be obtained in nuclear medicine examinations, even though it is not the actual measurement dose. In the future, to increase the utilization of the program, it will be produced as an application that can be used in mobile devices, so that the public can access it easily.

Extraction and Complement of Hexagonal Borders in Corneal Endothelial Cell Images (각막 내피 세포 영상내 육각형 경계의 검출과 보완법)

  • Kim, Eung-Kyeu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.3
    • /
    • pp.102-112
    • /
    • 2013
  • In this paper, two step processing method of contour extraction and complement which contain hexagonal shape for low contrast and noisy images is proposed. This method is based on the combination of Laplacian-Gaussian filter and an idea of filters which are dependent on the shape. At the first step, an algorithm which has six masks as its extractors to extract the hexagonal edges especially in the corners is used. Here, two tricorn filters are used to detect the tricorn joints of hexagons and other four masks are used to enhance the line segments of hexagonal edges. As a natural image, a corneal endothelial cell image which usually has regular hexagonal form is selected. The edge extraction of hexagonal shapes in corneal endothelial cell is important for clinical diagnosis. The proposed algorithm and other conventional methods are applied to noisy hexagonal images to evaluate each efficiency. As a result, this proposed algorithm shows a robustness against noises and better detection ability in the aspects of the output signal to noise ratio, the edge coincidence ratio and the extraction accuracy factor as compared with other conventional methods. At the second step, the lacking part of the thinned image by an energy minimum algorithm is complemented, and then the area and distribution of cells which give necessary information for medical diagnosis are computed.

Output-Only System Identification and Model Updating for Performance Evaluation of Tall Buildings (초고층건물의 성능평가를 위한 응답의존 시스템판별 및 모델향상)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.19-33
    • /
    • 2008
  • Dynamic response measurements from natural excitation were carried out for 25- and 42-story buildings to evaluate their inherent properties, such as natural frequencies, mode shapes and damping ratios. Both are reinforced concrete buildings adopting a core wall, or with shear walls as the major lateral force resisting system, but frames are added in the plan or elevation. In particular, shear walls in a 25-story building are converted to frames from the 4th floor level downwards while maintaining a core wall throughout, resulting in a fairly complex structure. Due to this, along with similar stiffness characteristics in the principal directions, significantly coupled and closely spaced modes of motion are expected in this building, making identification rather difficult. By using various state-of-the-art system identification methods, the modal parameters are extracted, and the results are then compared. Three frequency-domain and four time-domain based operational modal identification methods are considered. Overall, all natural frequencies and damping ratios estimated from the different identification methods showed a greater consistency for both buildings, while mode shapes exhibited some degree of discrepancy, varying from method to method. On the other hand, in comparison with analysis results obtained using the initial finite element(FE) models, test results exhibited a significant difference of about doubled frequencies, at least for the three lower modes in both buildings. To improve the correlation between test and analysis, a few manual schemes of FE model updating based on plausible reasons have been applied, and acceptable results are obtained. The advantages and disadvantages of each identification method used are addressed, and some difficulties that might arise from the updating of FE models, including automatic procedures, for such large structures are carefully discussed.

Estimation of Suspended Sediment Concentration in Small Stream with Acoustic Backscatter from Horizontal ADCP based on Real-Scale Field Experiment (실규모 현장 실험 기반 H-ADCP 초음파 산란도 활용 소하천용 하천 부유사 농도 측정 기법 개발)

  • Seo, Kanghyeon;Kim, Dongsu;Son, Geunsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.1023-1035
    • /
    • 2016
  • Suspended sediment concentration (SSC) is a crucial riverine parameter in terms that it can be utilized for analyzing sediment transport, stability assessment of river and structure and so on. However, in case of domestic, sediment discharge data are not enough because of using conventional sediment samplers. This study aimed at developing a practical technique for estimating suspended sediment concentration in high spatial and temporal resolution by building relationship between acoustic backscatter (or SNR) from H-ADCP with actually observed data using LISST-100X. In this regard, a dedicated correction algorithm was proposed particularly for the adapted H-ADCP (SonTek SL-3000). Then, a SNR-SSC relation was built based upon a real-scale field experiment, where both H-ADCP and LISST-100X were concurrently operated to observe SNR and SSC, respectively. The coefficient of determination for the developed regression equation of SNR-SSC relation was around 0.85~0.88, thereby the relation could be evaluated to be highly correlated. The result of this study might be potentially applied for real-time and simultaneous observation of SSC when H-ADCP could be applied.