• Title/Summary/Keyword: 자동 검사

Search Result 989, Processing Time 0.03 seconds

Relationship Between Carotid Intima-Media Thickness Using Ultrasonography and Diagnostic Indices of Metabolic Syndrome (초음파를 이용한 경동맥 내-중막 두께와 대사증후군 진단지표의 연관성)

  • Ko, Kyung-Sun;Heo, Kyung-Hwa;Won, Yong-Lim;Lee, Sung-Kook;Kim, Ki-Woong
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.285-291
    • /
    • 2009
  • The aim of the present study was undertaken to investigate the association between diagnostic indices of metabolic syndrome(MetS) with carotid intima-media thickness using ultrasonography. The participants in the study were 315 male employees without carotid atherosclerosis and other cardiovascular disease. This study was approved by the Institutional Review Board of Occupational Safety and Health Research Institute. Written informed consent for the participants in this study was obtained from all individuals. Anthropometric parameters and biochemical characteristics were done using each specific equipments and the NCEP-ATP III criteria were used to define MetS. They were examined by B-mode ultrasound to measure the carotid intima-media thickness(carotid IMT) at the near and far walls of common carotid and bifurcation(bulb). The mean carotid IMT was $0.739{\pm}0.137\;mm$ and it's thickness significantly increased with the increase in age. Also, amounts of systolic and diastolic blood pressure, triglyceride and fasting glucose were significantly increased with the increase in age. Carotid IMT were significantly correlated with BMI(r=0.170, p=0.004), systolic(r=0.148, p=0.011) and diastolic blood pressure(r=0.123, p=0.036) and HDL-cholesterol(r=-0.164, p=0.005). On multiple logistic regression analysis for the diagnostic indices of MetS, carotid IMT were significantly associated with blood pressure(OR=4.220, p<0.01) and MetS(OR=1.301, p<0.05). The results indicate that blood pressure and MetS are important risk factors for carotid atherosclerosis.

  • PDF

Changes in Quality of Citron Juice by Storage and Extraction Conditions (유자과즙의 저장 및 착즙조건에 따른 품질변화)

  • Park, Kee-Jai;Jung, Sung-Won;Kim, Jong-Hoon;Jeong, Jin-Woong
    • Applied Biological Chemistry
    • /
    • v.38 no.2
    • /
    • pp.141-146
    • /
    • 1995
  • Changes of physicochemical properties of citron juice prepared by two different extraction methods, rotary-crushing and belt-pressing method, were investigated during the storage at $5^{\circ}C$ and $-20^{\circ}C$. Temperature drop of citron juice extracted by belt-pressing method was faster than that of citron juice prepared by rotary-crushing method and its freezing point was $0.8{\sim}0.9^{\circ}C$. During the storage, pH of stored citron juice with rotary-crushing method was increased up to 3.5 after 6 months storage while that of citron juice extracted by belt-pressing method was not changed significantly during the same storage time. Acidity of rotary-crushed citron juice was reduced a little more than that of belt-pressed citron juice during the storage. However, changes of soluble solid content were influenced largely by the storage temperature than by the extraction method. Contents of formol nitrogen and vitamin C were reduced remarkably in all of stored citron juice and $92{\sim}82%$ of farmol nitrogen and $72{\sim}43%$ of vitamin C were remained after 6 months of storage. Among the changes of color value, L values were reduced in the whole stored citron juice and a and b value had a different change pattern respectively according to the extraction and storage temperature. Changes in the content of both amino acid and fatty acid compositions was also observed after same storage period. Especially, in the case of change of fatty acid composition, content of linoleic acid and linolenic acid were reduced after 6 months storage, while those of palmitic acid, stearic acid and oleic acid were increased.

  • PDF

The Number and Distribution of Bacteria falling in the Air of Dental Clinics (치과의원 공기중의 공중낙하세균수와 세균분포)

  • Jang, Gye-won;Kang, Yong-ju
    • Journal of dental hygiene science
    • /
    • v.4 no.1
    • /
    • pp.7-11
    • /
    • 2004
  • The purpose of this study was to investigate the distribution of microorganisms and the degree of contamination in the air of the dental clinics and to offer basic data as to the contamination of medical equipment and the prevention of the clinics. With this in mind, the researcher gathered air samples from the waiting rooms and medical offices of nine dental clinics in the city of J, South Korea with the use of a method of natural inattention and an air sampler and cultivated the samples on the plain table and drew from it bacteria falling and separated and sorted out the colony with the help of ATB and detected the distribution of the germs. The results are following, The number of bacteria falling in the air of the dental clinics was less than 10(CFU/Plate) with the exception of one dental clinic. This implies that they fit in with standards for hygiene. The number of bacteria falling in the air of the medical offices was less than 10(CFU/Plate) with the exception of one dental clinic. This implies that they fit in with standards for hygiene. The survey on the detection of staph. aureus reveals that all the dental clinics with the exception of B dental clinic proving to be positive had non-pathogenic staphylococci detected. The survey on the detection of pathogenic gram negative bacilli indicates that all the dental clinics but one were none detected. The survey on the distribution of germs shows that germs in 7 out of 9 dental clinics were none detected, and that they in four out of 9 waiting rooms were none detected. All the germs detected in the others were mostly non-pathogenic. The study shows that all the subject dental clinics but one were hygienically controlled and that there was a difference in accordance with cleaning and sterilization. This means that dental clinics should be equipped with systematic programs for cleaning and sterilization designed to prevent infection.

  • PDF

Design of Translator for generating Secure Java Bytecode from Thread code of Multithreaded Models (다중스레드 모델의 스레드 코드를 안전한 자바 바이트코드로 변환하기 위한 번역기 설계)

  • 김기태;유원희
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2002.06a
    • /
    • pp.148-155
    • /
    • 2002
  • Multithreaded models improve the efficiency of parallel systems by combining inner parallelism, asynchronous data availability and the locality of von Neumann model. This model executes thread code which is generated by compiler and of which quality is given by the method of generation. But multithreaded models have the demerit that execution model is restricted to a specific platform. On the contrary, Java has the platform independency, so if we can translate from threads code to Java bytecode, we can use the advantages of multithreaded models in many platforms. Java executes Java bytecode which is intermediate language format for Java virtual machine. Java bytecode plays a role of an intermediate language in translator and Java virtual machine work as back-end in translator. But, Java bytecode which is translated from multithreaded models have the demerit that it is not secure. This paper, multhithread code whose feature of platform independent can execute in java virtual machine. We design and implement translator which translate from thread code of multithreaded code to Java bytecode and which check secure problems from Java bytecode.

  • PDF

프렌차이점에서 사용되는 튀김류의 산패도 및 트랜스지방의 함량 비교

  • Kim, Yeong-Seong
    • Proceedings of the Korean Sanitation Conference
    • /
    • 2005.12a
    • /
    • pp.76-97
    • /
    • 2005
  • As the recent change of multiformity and taste in clination in eating habit culture is yearly in creasing foods used oil and fats. Because the frying food is especially important snack , it's safty is very essential. In order to know the safty and harmfulness of frying oil and fats. The 20 kinds samples were purchased chicken fried food shops around the north of seoul and kyunggi. The acid value, iodine value, peroxide value, TBA value, fatty acid, carbonyl value, and smoke point of deep fat fried oils were analyzed. Results of analyzed, A company of deep fat frying oil showed stability state and C company and B company of deep fat frying oil is acidification to turned. But D company of deep fat frying oil showed quite a bit acidification progressived of used hydrogenated oil.

  • PDF

RPC Correction of KOMPSAT-3A Satellite Image through Automatic Matching Point Extraction Using Unmanned AerialVehicle Imagery (무인항공기 영상 활용 자동 정합점 추출을 통한 KOMPSAT-3A 위성영상의 RPC 보정)

  • Park, Jueon;Kim, Taeheon;Lee, Changhui;Han, Youkyung
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_1
    • /
    • pp.1135-1147
    • /
    • 2021
  • In order to geometrically correct high-resolution satellite imagery, the sensor modeling process that restores the geometric relationship between the satellite sensor and the ground surface at the image acquisition time is required. In general, high-resolution satellites provide RPC (Rational Polynomial Coefficient) information, but the vendor-provided RPC includes geometric distortion caused by the position and orientation of the satellite sensor. GCP (Ground Control Point) is generally used to correct the RPC errors. The representative method of acquiring GCP is field survey to obtain accurate ground coordinates. However, it is difficult to find the GCP in the satellite image due to the quality of the image, land cover change, relief displacement, etc. By using image maps acquired from various sensors as reference data, it is possible to automate the collection of GCP through the image matching algorithm. In this study, the RPC of KOMPSAT-3A satellite image was corrected through the extracted matching point using the UAV (Unmanned Aerial Vehichle) imagery. We propose a pre-porocessing method for the extraction of matching points between the UAV imagery and KOMPSAT-3A satellite image. To this end, the characteristics of matching points extracted by independently applying the SURF (Speeded-Up Robust Features) and the phase correlation, which are representative feature-based matching method and area-based matching method, respectively, were compared. The RPC adjustment parameters were calculated using the matching points extracted through each algorithm. In order to verify the performance and usability of the proposed method, it was compared with the GCP-based RPC correction result. The GCP-based method showed an improvement of correction accuracy by 2.14 pixels for the sample and 5.43 pixelsfor the line compared to the vendor-provided RPC. In the proposed method using SURF and phase correlation methods, the accuracy of sample was improved by 0.83 pixels and 1.49 pixels, and that of line wasimproved by 4.81 pixels and 5.19 pixels, respectively, compared to the vendor-provided RPC. Through the experimental results, the proposed method using the UAV imagery presented the possibility as an alternative to the GCP-based method for the RPC correction.

Safety and Efficacy of Ultrasound-Guided Percutaneous Core Needle Biopsy of Pancreatic and Peripancreatic Lesions Adjacent to Critical Vessels (주요 혈관 근처의 췌장 또는 췌장 주위 병변에 대한 초음파 유도하 경피적 중심 바늘 생검의 안전성과 효율성)

  • Sun Hwa Chung;Hyun Ji Kang;Hyo Jeong Lee;Jin Sil Kim;Jeong Kyong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1207-1217
    • /
    • 2021
  • Purpose To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy (USPCB) of pancreatic and peripancreatic lesions adjacent to critical vessels. Materials and Methods Data were collected retrospectively from 162 patients who underwent USPCB of the pancreas (n = 98), the peripancreatic area adjacent to the portal vein, the paraaortic area adjacent to pancreatic uncinate (n = 34), and lesions on the third duodenal portion (n = 30) during a 10-year period. An automated biopsy gun with an 18-gauge needle was used for biopsies under US guidance. The USPCB results were compared with those of the final follow-up imaging performed postoperatively. The diagnostic accuracy and major complication rate of the USPCB were calculated. Multiple factors were evaluated for the prediction of successful biopsies using univariate and multivariate analyses. Results The histopathologic diagnosis from USPCB was correct in 149 (92%) patients. The major complication rate was 3%. Four cases of mesenteric hematomas and one intramural hematoma of the duodenum occurred during the study period. The following factors were significantly associated with successful biopsies: a transmesenteric biopsy route rather than a transgastric or transenteric route; good visualization of targets; and evaluation of the entire US pathway. In addition, the number of biopsies required was less when the biopsy was successful. Conclusion USPCB demonstrated high diagnostic accuracy and a low complication rate for the histopathologic diagnosis of pancreatic and peripancreatic lesions adjacent to critical vessels.

Effect of the Angle of Ventricular Septal Wall on Left Anterior Oblique View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 심실중격 각도에 따른 좌전사위상 변화에 대한 연구)

  • You, Yeon Wook;Lee, Chung Wun;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae;Bang, Ji-In;Lee, Soo Jin;Kim, Tae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.13-19
    • /
    • 2016
  • Purpose In order to calculate the left ventricular ejection fraction (LVEF) accurately, it is important to acquire the best septal view of left ventricle in the multi-gated cardiac blood pool scan (GBP). This study aims to acquire the best septal view by measuring angle of ventricular septal wall (${\theta}$) using enhanced CT scan and compare with conventional method using left anterior oblique (LAO) 45 view. Materials and Methods From March to July in 2015, we analyzed the 253 patients who underwent both enhanced chest CT and GBP scan in the department of nuclear medicine at National Cancer Center. Angle (${\theta}$) between ventricular septum and imaginary midline was measured in transverse image of enhanced chest CT scan, and the patients whose difference between the angle of ${\theta}$ and 45 degree was more than 10 degrees were included. GBP scan was acquired using both LAO 45 and LAO ${\theta}$ views, and LVEFs measured by automated and manual region of interest (Auto-ROI and Manual-ROI) modes respectively were analyzed. Results $Mean{\pm}SD$ of ${\theta}$ on total 253 patients was $37.0{\pm}8.5^{\circ}$. Among them, the patients whose difference between 45 and ${\theta}$ degrees were more than ${\pm}10$ degrees were 88 patients ($29.3{\pm}6.1^{\circ}$). In Auto-ROI mode, there was statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=62.0{\pm}6.6%$ vs. LVEF ${\theta}=64.0{\pm}5.6%$; P = 0.001). In Manual-ROI mode, there was also statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=66.7{\pm}7.2%$ vs. LVEF ${\theta}=69.0{\pm}6.4%$; P < 0.001). Intraclass correlation coefficients of both methods were more than 95%. In case of comparison between Auto-ROI and Manual ROI of each LAO 45 and LAO ${\theta}$, there was no significant difference statistically. Conclusion We could measure the angle of ventricular septal wall accurately by using transverse image of enhanced chest CT and applied to LAO acquisition in the GBP scan. It might be the alternative method to acquire the best septal view of LAO effectively. We could notify significant difference between conventional LAO 45 and LAO ${\theta}$ view.

  • PDF

Clinical Implication of Cyclooxygenase-2 Expression for Rectal Cancer Patients with Lymph Node Involvement (림프절 전이를 동반한 직장암 환자들에서 Cyclooxygenase-2 발현의 임상적 의미)

  • Lee, Hyung-Sik;Choi, Young-Min;Hur, Won-Joo;Kim, Su-Jin;Kim, Dae-Cheol;Roh, Mee-Sook;Hong, Young-Seoub;Park, Ki-Jae
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.210-217
    • /
    • 2009
  • Purpose: To assess the influence of cyclooxygenase-2 (COX-2) expression on the survival of patients with a combination of rectal cancer and lymph node metastasis. Materials and Methods: The study included rectal cancer patients treated by radical surgery and postoperative radiotherapy at the Dong-A university hospital from 1998 to 2004. A retrospective analysis was performed on a subset of patients that also had lymph node metastasis. After excluding eight of 86 patients, due to missing tissue samples in three, malignant melanoma in one, treatment of gastric cancer around one year before diagnosis in one, detection of lung cancer after one year of diagnosis in one, liver metastasis in one, and refusal of radiotherapy after 720 cGy in one, 78 patients were analyzed. The immunohistochemistry for COX-2 was conducted with an autostainer (BenchMark; Ventana, Tucson, AZ, USA). An image analyzer (TissueMine; Bioimagene, Cupertino, CA, USA) was used for analysis after scanning (ScanScope; Aperio, Vista, CA, USA). A survival analysis was performed using the Kaplan Meier method and significance was evaluated using the log rank test. Results: COX-2 was stained positively in 62 patients (79.5%) and negatively in 16 (20.5%). A total of 6 (7.7%), 15 (19.2%), and 41 (52.6%) patients were of grades 1, 2, and 3, respectively for COX-2 expression. No correlation was found between being positive of COX-2 patient characteristics, which include age (<60-year old vs. $\geq$60), sex, operation methods (abdominoperineal resection vs. lower anterior resection), degrees of differentiation, tumor size (<5 cm vs. $\geq$5 cm), T stages, N stages, and stages (IIIa, IIIb, IIIc). The 5-year overall and 5-year disease free survival rates for the entire patient population were 57.0% and 51.6%, respectively. The 5-year overall survival rates for the COX-2 positive and negative patients were 53.0% and 72.9%, respectively (p=0.146). Further, the 5-year disease free survival rates for the COX-2 positive and negative patients were 46.3% and 72.7%, respectively (p=0.118). The 5-year overall survival rates were significantly different (p<0.05) for the degree of differentiation, N stage, and stage, whereas the 5-year disease free survival rates were significant for N stage and stage. Conclusion: Being positive for and the degree of COX-2 expression did not have a significant influence on the survival of rectal cancer patients with lymph node metastasis. However, N stage and stage did significantly influence the rateof survival. Further analysis of a greater sample size is necessary for the verification of the effect of COX-2 expression on the survival of rectal cancer patients with lymph node involvement.