• Title/Summary/Keyword: 자동주입장치

Search Result 31, Processing Time 0.031 seconds

A Study on the Automatic Fuel-Filling-Recognition system for a city bus (자동인식 주유량 처리 시스템에 관한 연구)

  • 김현수;안병원;박중순;박영산;배철오;김철홍
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.414-417
    • /
    • 2001
  • In this paper the fuel filling system for a city bus was investigated in order to improve the system. The suggested fuel filling system was designed to have functions of identifying a bus arrival tine, and measuring volume of fuel filled. The system consisted of four parts of bus identification, IBM PC, interface card, fuel filling control system and program for integrating all parts. It is believed that the information obtained by this system can be used for analysing driver's driving habits and performance of engine of a bus, and accordingly the prime cost can be reduced.

  • PDF

Design of an Automatic Titration System for Caustic Soda Treatment System Using the Equivalent Point Estimation Algorithm (당량점 예측 알고리듬에 의한 가성소다 처리 섬유감량 시스템용 자동적정 장치 설계)

  • Cho, Jin-Ho;Jin, Kyoung-Chan;You, Byoung-Heui;Koo, Sung-Mo;Kim, Myoung-Nam;Lee, Jong-Hyun;Lee, Heung-Lark
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.3
    • /
    • pp.28-35
    • /
    • 1994
  • Caustic Soda Treatment Systems need a concentration measurement device in order to monitor the weight reduction amount of polyester fabrics. Since the reduction process requires several concentration measurements, we have to do the unit titration fast and exactly. Therefore, a proposition of estimation algorithm for finding the equivalent point in the titration process is needed. In this paper, we used the cardinal spline algorithm, to estimate the proper curve with the measured pH-values after each injection of titration sdution, to predict the equivalent point. While the processing time is elapsed, several equivalent points are estimated and drawed the line graph of fabrics weight reduction automatically. Finally, we designed the hardware and the software of an automatic titration system that can generate the reduction ending signal of Caustic Soda Treatment System.

  • PDF

Development and Evaluation of a Rapid BOD Measurement System (신속 BOD 측정장치의 개발 및 시험)

  • Oh, Hyuk;Choi, Don-Soo;Jeong, Hyuk;Choi, Ju-Hwan;Kim, Hai-Dong
    • Analytical Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.146-152
    • /
    • 1997
  • A rapid BOD measurement system using a microbial membrane electrode has been developed. Culture of microorganism and the preparation of microbial membrane, the effect of sample flow rate on the BOD measurement, the effect of solution pH and response characteristics of the microbial membrane electrode were investigated. The rapid BOD measurement system developed by us was connected to a personal computer and the whole BOD measurement procedures were carried out automatically. The best results were obtained when the solution flow rate was 7.8mL/min and the data were obtained 5 minutes after sample injection.

  • PDF

Automatic On-line BOD Measurement System Using A Microbial Membrane Electrode (미생물막 전극을 이용한 BOD 자동화 측정장치)

  • Oh, Hyuk;Kim, Hai Dong
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.335-340
    • /
    • 1995
  • Automatic biochemical oxygen demand(BOD) measurement system has heen developed using a microbial membrane electrode, prepared from Bacillus subtilis and polyvinyl alcohol(PVA). The automatic BOD measurement system showed a linear response curve up to BOD 60 ppm using a glucose/glutamic acid standard solution, and all the BOD measurement processes are carried out automatically to calculate BOD whithin 10 min after each sample injection. The response times of the microbial electrode was 5 minutes with a 5 min recovery time between measurements and the relative error of the BOD estimation was within 10%.

  • PDF

Laboratory Tests for Trichloroethylene (TCE) and Toluene Remediation in Soil Using Soil Vapor Extraction (토양증기추출(Soil Vapor Extraction)을 이용한 토양 내 Trichloroethylene (TCE)과 Toluene정화 실험)

  • 이민희;강현민
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.221-227
    • /
    • 2002
  • Column experiments were performed to evaluate the removal efficiency of soil vapor extraction (SVE) iota TCE (trichloroethylene) and toluene in soil. Homogeneous Ottawa sands and real soils collected from contaminated area were used to investigate the effect of soil properties and SVE operation conditions on the removal efficiency. In column teats with two different sizes of Ottawa sand, the maximum effluent TCE concentration in a coarse sand column was 442 mg/L and 337 mg/L in a fine sand column. However, after 20 liter gas flushing, the effluent concentrations were very similar and more than 90% of initial TCE mass were removed from the column. For two real contaminated soil columns, the maximum effluent concentration decreased 50% compared with that in the homogeneous Ottawa coarse sand column, but 99% of initial TCE mass were extracted from the column within 40 liter air flushing, suggesting that SVE is very available to remove volatile NAPLs in the contaminated soil. To investigate the effect of contaminant existing time on the removal efficiency, an Ottawa sand column was left stable for one week after TCE was injected and the gas extraction was applied into the column. Its effluent concentration trend was very similar to those for other Ottawa sand columns except that the residual TCE after the air flushing showed relatively high. Column tests with different water contents were performed and results showed high removal efficiency even in a high water content sand column. Toluene as one of BTEX compounds was used in an Ottawa sand column and a real soil column. Removal trends were similar to those in TCE contaminated columns and more than 98% of initial toluene mass were removed with SVE in both column.

The Development of an Automatic Molten Metal Supplier for an Aluminum Thermal Furnace (알루미늄 보온로 용탕 자동공급 시스템 개발)

  • Lee, Jun-Ho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.5
    • /
    • pp.483-490
    • /
    • 2009
  • The objective of this development project is to localize an automatic molten metal supplier that has been distributed by WESTOMAT, Germany, throughout the world. To achieve this purpose, an energy-saving pressurized dosing furnace and molten metal differential pressure control system that Is able to automatically supply a determined quantity of aluminum molten metal were developed. The localized equipment was installed in a site. Also, the results of the test operation of this equipment can be summarized as follows: It was able to improve the productivity because there were small decreases in supplying speeds and small losses in wastes compared to the existing mechanical molten metal supplier. Also, it was able to minimize the cost in maintenances due to the direct application of high temperature molten metals to molds. In addition, there were small energy losses due to the use of high thermal insulators compared to the existing reverberating furnace and able to prolong the life-time of furnaces and produce good quality nonferrous metals because it represented small carbon refractories and alumina in applied molten metals. Furthermore, it demonstrated no particular differences by objectively comparing it with the product by WESTOMAT.

  • PDF

A study on IV-set Monitering System Development using by ISM Band (ISM 소출력 무선통신을 이용한 수액세트 감시 시스템 개발에 관한 연구)

  • Cho, Young-Seok
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2010.07a
    • /
    • pp.289-292
    • /
    • 2010
  • 본 연구에서는 ISM 밴드 소출력 무선 통신을 이용한 수액세트 감시시스템 개발에 대하여 연구하였다. 사회가 발전하면서 복지 수요가 증가되고 있으며 특히 의료 서비스에 대한 수요의 증가가 예상되고 있다. 유비쿼터스를 이용한 각종 의료장비들이 개발되고 있다. 본 논문에서는 병원의 응급실이나 중환자실과 같이 수액공급시 수액의 주입여부, 종료여부를 감시하는 수액세트 자동 감시시스템을 개발하고자 한다. 수액세트 감시장치는 센서부와 수신부로 구성되며, 센서부는 수액 백으로부터 수액이 공급중인지 여부를 검출하고 검출된 신호를 처리한 후 447MHz ISM 밴드의 무선주파수를 이용하여 중앙통제실로 전송한다. 센서부는 동전형 리튬전지를 이용하여 3개월 사용하도록 설계 구현하였고 실내에서최대 65m까지 전송이 가능하였다. 수신부는 센서부에서 전송된 데이터를 표시하는 기능을 한다.

  • PDF

Simultaneous Determination of Various Pesticides (I): Analysis by GC with ECD and NPD Dual Detectors (잔류농약 다성분 동시분석법에 관한 연구(I): GC-ECD 및 NPD를 병렬 사용한 분석)

  • Rho, Kyoung-Ah;Kim, Jin-Ho;Kim, Hyeon-Wee;Lee, Yoon-Kyoung;Park, Ki-Moon
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.427-431
    • /
    • 1997
  • A simultaneous and rapid gas chromatographic determination of organophosphorus, organo-chlorine, carbamate, and pyrethroid pesticides in polished rice was developed. The pesticides were extracted from samples with acetone by automated soxhlet apparatus and this extract was evaporated to dryness. The residue was dissolved in hexane, the solvent was applied to a Sep-Pak florisil catridge, was eluted with 50% ethyl acetate in n-hexane, and was injected to dual GC-ECD/NPD system. This simple method affords a high recovery of hydrophilic pesticides, allows rapid analysis, and is cheap to perform. Except for dichlorvos and captan, recoveries of 46 pesticides were over 60%.

  • PDF

Simultaneous Determination of Various Pesticides : Analysis Utilizing GC/MSD (SIM mode) (잔류농약 다성분 동시분석법 : GC-MSD (SIM mode)를 사용한 분석)

  • Rho, Kyoung-Ah;Kim, Hyeon-Wee;Lee, Yoon-Kyoung
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.721-727
    • /
    • 1998
  • An analytical method for simultaneous and rapid determination of organophosphorus, organochlorine, carbamate, and pyrethroid pesticides in polished rice was developed. The analysis is performed by gas chromatograph with mass selective detector (GC/MSD) in selected ion monitoring (SIM) mode. Pesticides were extracted from samples with acetone by automated Soxhlet apparatus and this extract was evaporated to dryness for the analysis. The residue was dissolved in hexane, followed by a treatment with a Sep-Pak florisil catridge. Pesticides were positively confirmed by GC/MS, retention times, and ion ratios. This analytical method allows a rapid, reliable, and a good recovery of hydrophilic pesticides. Except far captafol, captan, dichlofluanid and dichlorvos, recoveries of 42 pesticides were over 70%.

  • PDF

Design of the Blood Pressure Measurement System Using the Inflatable Oscillometric Method (가압식 오실로메트릭 방법을 사용한 혈압측정 시스템의 설계)

  • 노동곤;이윤선;지정호;박성빈;이계형;김해관
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.281-286
    • /
    • 2003
  • Blood Pressure is one of the most fundamental Parameters which reflects physical conditions medically and the blood pressure measurement system using oscillometric method is a Non-Invasive Blood Pressure measurement device by measuring arterial Pressure through a cuff. In this paper. we designed a inflatable wrist blood pressure system which measures blood Pressure during the stepping inflation in the wrist cuff. The hardware system consists of a main power unit, a bladder in cuff unit, signal detection units, signal Processing units. a wireless data transmission unit, and a data display unit. We evaluated the reliability of this system by comparing and analyzing systolic. diastolic blood Pressure, and heart rate with other commercial blood Pressure measurement devices. Characteristic ratio values used to determine systolic and diastolic blood Pressure using MAA(Maximum Amplitude Algorithm) were 0.436 and 0.671 respectively.