• Title/Summary/Keyword: 자동조절

Search Result 788, Processing Time 0.031 seconds

Supplemental Lighting by HPS and PLS Lamps Affects Growth and Yield of Cucumber during Low Radiation Period (약광기 HPS와 PLS lamp를 이용한 오이의 보광재배효과)

  • Kwon, Joon-Kook;Yu, In-Ho;Park, Kyoung-Sub;Lee, Jae-Han;Kim, Jin-Hyun;Lee, Jung-Sup;Lee, Dong-Soo
    • Journal of Bio-Environment Control
    • /
    • v.27 no.4
    • /
    • pp.400-406
    • /
    • 2018
  • In this experiment the effect of supplemental lighting on the growth and yield of cucumber (Cucumis sativus L. 'Fresh') plants during low radiation period of winter season were investigated in glasshouses using common high-pressure sodium (HPS) lamps and newly developed plasma lighting system (PLS) lamps. Plants grown without supplemental lighting were considered as a control. Supplemental lighting was provided from November 20th, 2015 to March 15th, 2016 to ensure 14-hour photoperiod (natural+supplemental light), also lamps were operated automatically when the outside sun radiation levels were less than $100W{\cdot}m^{-2}$. Spectral analysis showed that HPS lamp had a discrete spectrum, lacked of the radiation in the 400-550 nm wave band (blue-green light), but had a high output in the orange-red region (550-650 nm). A higher red light output resulted in an increased red to far-red (R/FR) ratio in HPS lamp. PLS had a continuous spectrum and had a peak radiation in green region (490-550 nm). HPS has 12.6% lower output in photosynthetically active radiation (PAR) but 12.6% higher output in near infra-red (NIR) spectral regions compared to PLS. Both HPS and PLS lamps emitted very low levels of ultra-violet radiation (300-400 nm). Supplemental lighting both from HPS and PLS lamps increased plant height, leaf number, internode number and dry weight of cucumber plants compared to control. Photosynthetic activity of cucumber plants grown under two supplemental lighting systems was comparable. Number of fruits per cucumber plant (fruit weight per plant) in control, PLS, and HPS plots were 21.2 (2.9 kg), 38.7 (5.5 kg), and 40.4 (5.6 kg), respectively, thereby increasing yield by 1.8-1.9 times in comparison with control. An analysis of the economic feasibility of supplemental lighting in cucumber cultivation showed that considering lamp installation and electricity costs the income from supplemental lighting increased by 37% and 62% for PLS and HPS lamps, respectively.

Determination of Appropriate Location for Baby Leaf Vegetable in Multi Bench System of Rice Seedling Nursery Facility During High Temperature Periods (다단식 벼육묘시설을 활용한 고온기 어린잎채소 재배 적정 위치 선발)

  • Kim, Jae Kyung;Kim, Il Seop;Kang, Ho Min;Choi, Ki Young
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.286-292
    • /
    • 2019
  • This study aimed to investigate the suitable of layer on growth of six baby leaf vegetables using existing facilities and equipment in rice seedling nursery. Three kinds of Lactuca(lettuce 'Jinppallola' and 'Romain white', and indian lettuce), two of Brassica(tatsoi and red tatsoi) and amaranth were used as the materials. After sowing, the rice seedling tray was placed in multi bench system($L120{\times}W60{\times}H195cm$, 10th floor), which were low(1st) layer above 15cm, middle(4th) layer above 115cm and high(7th) layer above 175cm apart from ground. Irrigation was sprayed 2~3 times a day using a automatic irrigation system. The growth characteristics and leaf color were investigated when leaf vegetables were reached the optimum size(within 10cm of plant height). During the culture periods(29th Jun.~31th Jul. 2017), daytime average temperature was $27.4{\sim}28.3^{\circ}C$ regardless of layers but solar irradiance was higher in the high-layer than low and middle-layer of 37% and 22%, respectively. The leaf length, leaf width and number of leaves in middle and high-layer have a tendency to increase but, fresh weight was different according to the layer. When the correlation between accumulation radiation and growth was analyzed, all of growth factor of Amaranth showed a high correlation and other cultivars showed correlation with each growth factors. As a result, It is suitable that amaranth and red tatsoi for high-layer, Indian lettuce and tatsoi for middle and high-layer and 'Romain white' for middle-layer. The growth of red lettuce 'Jinppallola' was good at low layer, but leaf color expression was poor. So the high layer is suitable for 'Jinppallola'.

Growth and Quality of the Strawberry (Fragaria annanassa Dutch. cvs. 'Sulhyang') as affected by Complex Nutrient Solution Supplying Control System using Integrated Solar Irradiance and Substrate Moisture Contents in Hydroponics (수경재배 시 적산 일사량과 배지 수분 함량 복합 급액 제어에 의한 '설향' 딸기(Fragaria annanassa Dutch. cvs. 'Sulhyang')의 생육 및 품질)

  • Choi, Su Hyun;Kim, So Hui;Lee Choi, Gyeong;Jeong, Ho Jeong;Lim, Mi Young;Kim, Dae Young;Lee, Seon Yi
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.367-376
    • /
    • 2021
  • Strawberry cultivation in Korea is grown in greenhouse, but most farms manage their water supply using a timer control method based on the experience of growers. The timer control has problems in that it is difficult to consider the weather condition, the growth stage of crops, and the moisture content of the substrate, so that the crops cannot be managed at an optimal level, and the accuracy of cultivation management are lacking. The watering methods using integrated solar irradiance and substrate moisture contents are control systems that provide eco-friendly and precise water supply considering the growth conditions of crops. The purpose of this study was to compare the combined water supply control with integrated solar irradiance and substrate moisture contents and timer control method in hydroponic cultivation of strawberries using coir, and to set the optimal integrated solar irradiance level for complex water supply control. The irrigation system was automatically watered when it reached 100, 150, 250 J·cm-2 based on the external solar irradiance, and forced irrigation was performed at a substrate moisture content of less than 60% in all treatments. The amount of irrigation at once was 50 mL. The timer treatment was applied as a control. The smaller the level of integrated radiation to start watering, the greater the daily amount of irrigation. Both the fresh weight and dry weight per plant were higher in the complex irrigation control method than the timer control, and the 100 and 150 J·cm-2 treatment had the highest fresh weight, and the 100 J·cm-2 treatment showed a significantly higher dry weight. The yield was also significantly higher in the complex control method than in the timer, and the early yield increased as the level of integrated solar irradiance was smaller. The fresh weight of fruit was the lowest in the timer-controlled irrigation. As a result of this study, the possibility of combined control irrigation method using integrated solar irradiance and substrate moisture content was confirmed for precise water supply management of strawberries in hydroponics.

Comparisons of Soil Water Retention Characteristics and FDR Sensor Calibration of Field Soils in Korean Orchards (노지 과수원 토성별 수분보유 특성 및 FDR 센서 보정계수 비교)

  • Lee, Kiram;Kim, Jongkyun;Lee, Jaebeom;Kim, Jongyun
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.401-408
    • /
    • 2022
  • As research on a controlled environment system based on crop growth environment sensing for sustainable production of horticultural crops and its industrial use has been important, research on how to properly utilize soil moisture sensors for outdoor cultivation is being actively conducted. This experiment was conducted to suggest the proper method of utilizing the TEROS 12, an FDR (frequency domain reflectometry) sensor, which is frequently used in industry and research fields, for each orchard soil in three regions in Korea. We collected soils from each orchard where fruit trees were grown, investigated the soil characteristics and soil water retention curve, and compared TEROS 12 sensor calibration equations to correlate the sensor output to the corresponding soil volumetric water content through linear and cubic regressions for each soil sample. The estimated value from the calibration equation provided by the manufacturer was also compared. The soil collected from all three orchards showed different soil characteristics and volumetric water content values by each soil water retention level across the soil samples. In addition, the cubic calibration equation for TEROS 12 sensor showed the highest coefficient of determination higher than 0.95, and the lowest RMSE for all soil samples. When estimating volumetric water contents from TEROS 12 sensor output using the calibration equation provided by the manufacturer, their calculated volumetric water contents were lower than the actual volumetric water contents, with the difference up to 0.09-0.17 m3·m-3 depending on the soil samples, indicating an appropriate calibration for each soil should be preceded before FDR sensor utilization. Also, there was a difference in the range of soil volumetric water content corresponding to the soil water retention levels across the soil samples, suggesting that the soil water retention information should be required to properly interpret the volumetric water content value of the soil. Moreover, soil with a high content of sand had a relatively narrow range of volumetric water contents for irrigation, thus reducing the accuracy of an FDR sensor measurement. In conclusion, analyzing soil water retention characteristics of the target soil and the soil-specific calibration would be necessary to properly quantify the soil water status and determine their adequate irrigation point using an FDR sensor.

The Comparison of Quantitative Indices by Changing an Angle of LAO View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 좌전사위상 각도의 변화에 따른 정량적 지표 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Ryu, Jae-Kwang;Kim, Seong-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.57-61
    • /
    • 2012
  • Purpose: The multi-gated cardiac blood pool scan is to evaluate the function of left ventricle (LV) and usefully observe a value of ejection fraction (EF) for a patient who is receiving chemotherapy. To calculate LVEF, we should adjust an angle of left anterior oblique (LAO) view to separate both ventricles. And by overlapped ventricles, it is possible to affect LVEF. The purpose of this study is to investigate and compare quantitative indices by changing an angle of LAO view. Materials and methods: We analyzed the 49 patients who were examined by multi-gated cardiac blood pool scan in department of nuclear medicine at Asan Medical Center from June to September 2011. Firstly, we acquired "Best septal" view. And then, we got images by addition and subtraction of angle for LAO view to anterior and lateral. We compared three LAO views for 20 people by 5 degrees and 39 people by 10 degrees. And we analyzed quantitative indices, EF, end diastole and end systole counts, by automated and manual region of interest (ROI) modes. Results: Firstly, we analyzed quantitative indices by automated ROI mode. In case of 5 degrees, the averages of EF are $61.0{\pm}7.5$, $62.1{\pm}7.1$, $60.9{\pm}6.7%$ ($p$=0.841) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $62.4{\pm}9.5$, $62.3{\pm}10.8$, $61.6{\pm}.9.3%$ ($p$=0.938) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Secondly, we analyzed quantitative indices by manual ROI mode. In case of 5 degrees, the averages of EF are $62.8{\pm}7.1$, $63.6{\pm}7.5$, $62.7{\pm}7.3%$ ($p$=0.903) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $65.5{\pm}9.0$, $66.3{\pm}8.7$, $63.5{\pm}.9.3%$ (p=0.473) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Conclusion: When an image is nearly "Best septal" view, the difference of LAO angle would not affect to change LVEF. Although there was no difference in quantitative analysis, deviations could happen when to interpret wall motion qualitatively by reading physicians.

  • PDF

The Comparative Analysis of Exposure Conditions between F/S and C/R System for an Ideal Image in Simple Abdomen (복부 단순촬영의 이상적 영상구현을 위한 F. S system과 C.R system의 촬영조건 비교분석)

  • Son, Sang-Hyuk;Song, Young-Geun;Kim, Je-Bong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.37-43
    • /
    • 2007
  • 1. Purpose : This study is to present effective exposure conditions to acquire the best image of simple abdomen in Film Screen (F.S) system and Computed Radiography (C.R) system. 2. Method : In the F.S system, while an exposure condition was fixed as 70kVp, images of a patients simple abdomen were taken under the different mAs exposure conditions. Among these images, the best one was chosen by radiologists and radiological technologists. In the C.R system, the best image of the same patient was acquired with the same method from the F.S system. Both characteristic curves from F.S system and C.R system were analyzed. 3. Results : In the F.S system, the best exposure condition of simple abdomen was 70kVp and 20mAs. In the CR system, with the fixed condition at 70kVp, the image densities of human organs, such as liver, kidney, spleen, psoas muscle, lumbar spine body and iliac crest, were almost same despite different environments (3.2mAs, 8mAs, 12mAs, 16mAs and 20mAs). However, when the exposure conditions were over or under (below) 12mAs, the images between the abdominal wall and the directly exposed part became blurred because the gap of density was decreased. In the C.R system, while the volume of mAs was decreased, an artifact of quantum mottle was increased. 4. Conclusion : This study shows that the exposure condition in the C.R system can be reduced 40% than in the F.S system. This paper concluded that when the exposure conditions are set in CR environment, after the analysis of equipment character, such as image processing system(EDR : Exposure Data Recognition processing), PACS and so on, the high quality of image with maximum information can be acquired with a minimum exposure dose.

  • PDF

Effects of Deletion of Supplementary Vitamins and Trace Minerals on Performance, Muscle Vitamin E and Fecal Trace Mineral Contents in Finishing Pigs (비육후기 사료에서 비타민-미량광물질 첨가제의 제거가 돼지의 성장 능력, 근육 내 비타민 E 및 분 중 미량광물질 함량에 미치는 영향)

  • Lee, S.C.;Lee, C.E.;Kim, K.I.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.543-550
    • /
    • 2003
  • Two experiments were conducted to determine the effects of deletion of vitamin and trace mineral premixes on growth, feed efficiency, backfat thickness, hemoglobin content, muscle vitamin E content, and fecal, serum and muscle trace mineral contents in finishing pigs raised under two different housing conditions. In Exp. 1, three pens (or experimental units) of five pigs each (average weight $\pm$ s.e., 70 $\pm$ 0.5 kg) were assigned to a control diet (with vitamin and trace mineral premixes) or diets with 50 or 100% of the premixes deleted. Pigs were fed to market weight under sub-optimal housing conditions with sawdust-covered concrete floor and no electrical ventilation. In Exp. 2, three pens of four pigs each (average weight $\pm$ s.e., 56 $\pm$ 1.1 kg) were assigned to a control (with vitamin and trace mineral premixes), Diet-P (100% of the premixes deleted) or Diet-P+E (Diet-P plus 100 mg $\alpha$-tocopherol acetate/kg diet fed for the last 2 wk before slaughter). Pigs were fed to market weight under optimal housing conditions with 70%-slatted concrete floor, electrical ventilation and temperature control. No significant differences were found in average daily gain (ADG), average daily feed intake (ADFI), and gain/feed among treatments in both experiments, but in Exp. 2 done with younger pigs, ADG and ADFI tended to be higher in the control group than in pigs fed diet without premixes. Hemoglobin content, hematocrit and red blood cell count were not influenced by the deletion of premixes. Backfat thickness was not different among treatments. Fecal Mn (twofold) and Zn (threefold) contents were higher in the control than in pigs fed diets without the premixes. Serum trace mineral contents were not influenced by diets. $\alpha$-Tocopherol content in gluteus maxima was decreased (P< 0.01) by deleting the dietary premixes, but increased to the level higher than the control by adding 100 mg $\alpha$-tocopheryl acetate/kg diet fed for the last 2 wk before slaughter. Results indicate that: 1) supplementary vitamins and trace minerals may not be necessary for optimum growth in finishing pigs, and 2) deletion of the dietary premixes reduces muscle vitamin E content, but the reduced content can be reversed by adding $\alpha$- tocopherol to diets fed for the last 2 wk before slaughter. The deletion may help to alleviate the environmental load of certain minerals from manure.

Predicting Powers of Spherical Rigid Gas-permeable Lenses Prescription (구면 RGP 렌즈의 처방 굴절력 예측)

  • Yu, Dong-Sik;Yoo, Jong-Sook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.219-225
    • /
    • 2010
  • Purpose: Usefulness in predicting the power of spherical rigid gas-pearmeable (RGP) lenses prescription using dioptric power matrices and arithmetic calculations was evaluated in this study. Noncycloplegic refractive errors and over-refractions were performed on 110 eyes of 55 subjects (36 males and 19 females, aged $24.60{\pm}1.55$years) in twenties objectively with an auto-refractometer (with keratometer) and subjectively. Tear lenses were calculated from keratometric readings and base curves of RGP lenses, and the power of RGP lenses were computed by a dioptric power matrix and an arithmetic calculation from the manifest refraction and the tear lens, and were compared with those by over-refractions in terms of spherical (Sph), spherical quivalent (SE) and astigmatic power. Results: The mean difference (MD) and 95% limits of agreement (LOA=$MD{\pm}1.96SD$) were better for SE (0.26D, $0.26{\pm}0.70D$) than for Sph (0.61D, $0.61{\pm}0.86D$). The mean difference and agreement of the cylindrical power between matrix and arithmetic calculation (-0.13D, $-0.13{\pm}0.53D$) were better than between the others (-0.24D, $0.24{\pm}0.84D$ between matrix and over-refraction; -0.12D, $0.12{\pm}1.00D$ between arithmetic calculation and over-refraction). The fitness of spherical RGP lenses were 54.5% for matrix, 66.4% for arithmetic calculation and 91.8% for over-refraction. Arithmetic calculation was close to the over-refraction. Conclusions: In predicting indications and powers of spherical RGP lens fitting, although there are the differences of axis between total (spectacle) astigmatism and corneal astigmatism, Spherical equivalent using an arithmetic calculation provides a more useful application than using a dioptric power matrix.

Trends and Refractive Status of Cataract Surgery - An Optometry Clinic-Based Survey in Chungbuk (백내장 수술 경향과 굴절상태 - 충북 지역의 안경원 중심으로 조사)

  • Kim, Hyeong-Su;Son, Jeong-Sik;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.143-148
    • /
    • 2013
  • Purpose: The aim of this study was to investigate the distribution of age and gender, types of intraocular lens (IOL), and refractive errors in subjects who had cataract surgery. Methods: 2,217 subjects who had cataract surgery were surveyed at an optometry clinic in Chungbuk from 2010 to 2012. Information about IOL was obtained from case history, reflective and retroillumination images IOL by auto refracto-keratometer. Refractive errors were determined by objective and subjective refraction. Results: The mean age of the subjects was $71.74{\pm}10.62$ years. The number of cataract surgeries increased from 524 persons in 2010 to 888 persons in 2012. Of the subjects surveyed, 52 persons (2.3%) were under the 40 years of age, 144 persons (6.5%) were in 50s, 404 persons (18.2%) were in 60s, 1,132 persons (51.1%) were in 70s, 485 persons (21.9%) were in above 80s. Cataract surgery was significantly prevalent in more female (1,338 persons, 60.4%) than in male (879 persons, 39.6%). Types of IOL were 2,141 persons (96.6%) for monofocal lens, special IOLs such as multifocal, accommodative and toric lens were 76 persons (3.4%). The distribution of refractive errors after cataract operation were 1,588 eyes (38.5%) for simple myopic astigmatism, 327 eyes (7.9%) for simple hyperopic astigmatism, 601 eyes (14.6%) for mixed astigmatism, 1,240 eyes (30.0%) for myopia, 136 eyes (3.3%) for hyperopia, and 234 eyes (5.7%) for emmetropia. The uncorrected and best corrected visual acuity of the subjects were $0.55{\pm}0.25$ and $0.80{\pm}0.23$, respectively. Conclusions: The prevalence of cataract surgery increased with age until 70s years of age, it was more prevalent in men than women over 60s, and frequency of special types of IOL were low. Most cataract surgeries left residual refractive errors. Therefore even after cataract surgery it may need spectacles for better vision at either distance or near.

The Efficacy and Effect of Reverse Geometry Contact Lens on Cornea (역기하학 렌즈의 유효성과 각막에 미치는영향)

  • Kim, Kwang-Bae;Kim, Young-Hoon;Bark, Sang-Bai;Sun, Kyung-Ho;Jeong, Youn-Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.2
    • /
    • pp.1-12
    • /
    • 2007
  • Object of this research is to estimate the effect of myopia correction and safety on reverse geometry contact lens fitting in school children. This research include 53(106eyes) schoolchildren among 7 to 18 years who has low to moderate myopia(-1.00D~-5.00D) and prescribed reverse geometry contact lens for purpose on orthokeratology between January to July 2004 and had 3months full follow up examination. They were tested for slit lamp examinations, BUT(Break up time), direct ophthalmoscopy, retinoscopy, uncorrected visual acuity, best corrected visual acuity, autorefraction, autokeratometry and corneal topography in each examination(1day, 1week, 2weeks, 1, 2, and 3months) of before-and-after lens wearing to find out the effect of myopic correction and side effect. The results came out as follow. The average of uncorrected visual acuity was $0.0938{\pm}0.378$ before lens wear and $0.3136{\pm}0.283$ after 1day lens wear, and there was fast improvement after 1week($0.7925{\pm}0.301$) and little improvement after 2weeks period but still they shows better uncorrected visual acuity(p<0.01). The result of this study, the reverse geometry lens is very useful to correct refractive error and control the progression of myopia temporally among low to moderate myopic patient. The side effects were relatively rare but further study should be necessary with long term lens wear effect on eye health. For the lens prescription, the clinical fitting process had higher rate of success with consideration of eccentricity and corneal topography.

  • PDF