• 제목/요약/키워드: 자기 진단 신호

검색결과 163건 처리시간 0.032초

Differentiation of Malignant from Benign Soft-Tissue Solid Tumors: Clinical and MR Finding Complex (연조직고형종양의 악성과 양성 감별: 임상과 자기공명영상 복합소견)

  • Moon, Tae-Yong;Kim, Jung-Il;Shin, Su-Mi;Choo, Hye-Jeung;Choi, Hyun-Wook;Kim, Soo-Jin
    • The Journal of the Korean bone and joint tumor society
    • /
    • 제10권2호
    • /
    • pp.79-87
    • /
    • 2004
  • Purpose: The recent development of MR has made to possible radiological diagnosis in various soft tssue tumors. But multifarious components within soft tissue tumors and their periodic change have made to difficult even differentiation of malignant from benign soft tissue tumors solely on the MR. So authors retry to differentiate malignant from benign soft tissue tumors with clinical and MR finding complex. Materials and methods: We were analysed 82 pathologically confirmed soft tissue solid tumors (37 cases as malignancy including intermediate tumors and 45 cases as benign including inflammatory masses) which are correlated with clinical findings such as age, size, and location, MR findings such as tumor border, texture on T2 and contrast-T1 images, and enhancement area retrospectively. Many typical lipoma and cysts including of ganglion and abscess are rejected in the benign soft tissue tumor group because not difficult to diagnose on MR. Results: Malignant soft tissue tumors were more frequent in 21~40 and 61~80 years old of the age, above 3.0 cm of the size, trunk-pelvis-lower extremities of the location, and MR findings with irregular border and above 50% of the enhancement area than those of benign soft tissue tumors. Conclusion: The clinical finding that divided to two locations as trunk-pelvis-lower extremities and upper extremities-shoulder-spine was statistically significant to differentiate malignant from benign soft tissue solid tumors. However, the others would provide some useful informations to differentiate them never specific.

  • PDF

Development of multi-robot control system (다중 로보트 제어시스템의 개발)

  • 서일홍;현웅근;김태원;여희주;허우정;이경호;양승원;임준홍;오상록
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.497-501
    • /
    • 1990
  • 본 논문에서는 다중로보트의 제어를 위하여 비젼 센서 등 여러 가지 센서신호를 처리할 수 있고 로봇의 충돌회피 및 협조제어를 할 수 있는 제어시스템을 개발하였다. 본 제어장치는 시스템 전체를 관리하며 언어 및 로보트 동작의 교시 그리고 자기진단 등의 기능을 하는 Supervisory Processor, vision에 대한 정보를 담당하는 로보트 제어 processor 등 여러개의 프로세서로 나누어 분산처리 구조를 갖도록 하여 확장성 및 유연성이 높은 시스템이 되도록 하였다. 실험적으로 본 시스템을 이용하여 로보트로 하여금 puzzle을 맞추는 작업을 수행시킴으로써 본 시스템의 우수성을 입증하였다.

  • PDF

Canine MR Images from 3T Active-Shield MRI System (3T 능동차폐형 자기공명영상 장비로부터 얻어진 개의 자기공명영상)

  • Choe, Bo-Young;Park, Chi-Bong;Kang, Sei-Kwon;Chu, Myoung-Ja;Kim, Euy-Neyng;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • 제12권2호
    • /
    • pp.113-124
    • /
    • 2001
  • For veterinary imaging diagnosis, we obtained MR images of the canine brain, spine, kidney and pelvis from 3T MRI system which was equipped with the world first 3T active shield magnet. Spin echo (SE) and fast Spin Echo (FSE) images were obtained from the canine brain, spine, kidney and pelvis of normal and sick dogs using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. In addition, we employed a homemade saddle shaped RF coil. Typical common acquisition parameters were as follows: matrix=512$\times$512, field of view (FOV)=20cm, slice thickness=3 w, number of excitations (NEX)=1. For T1-weighted MR images, we used TR=500 ms, TE=10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE=108 ms. Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.57 system. The high resolution images acquired in this study represent more than a 4-fold increase in in-plane resolution relative to conventional images obtained with a 20 cm field of view and a 5 mm slice thickness. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter The present results demonstrate that the MR images from 3T system could provide better diagnostic quality of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods. Moreover, MRI technique could begin to apply for veterinary medicine in Korea.

  • PDF

Quantitative evaluation of MRI distortion using orthopedic prosthetic metal (정형보철용 금속을 이용한 자기공명영상왜곡의 정량적 평가)

  • Kim, Hyeonggyun
    • Journal of the Korean Society of Radiology
    • /
    • 제7권1호
    • /
    • pp.57-62
    • /
    • 2013
  • Despite the many advantages of magnetic resonance imaging in orthopedic prosthetic body image distortion to the differences in the magnetic susceptibility occurs. Attached to the phantom and pork produced by the same $65{\times}15{\times}2mm$ stainless steel and titanium specimen examined the relationship between magnetic resonance imaging and phantom images, the signal intensity changes of the subcutaneous tissue, fat-suppressed quantitative assessment of the degree through the length of image distortion and pig bones. Stainless steel to titanium to 2.8 times 4.4 times in the longitudinal direction than in the direction of the height of large image distortion, signal strength is relatively low 58.5%. Normal 56.2% compared to the subcutaneous tissue, fat-suppressed, were stainless steel 16.04%, 54.53% titanium. Experimental results than the diagnostic value of magnetic resonance imaging (MRI) images of stainless steel with a titanium metal if better could see.

Various MRI Findings of Toxocara canis Myelitis (개회충 척수염의 다양한 자기공명영상 소견)

  • Sun Young Park;Kyung Seok Park;Eugene Lee;Joon Woo Lee;Yun Jung Bae;Yusuhn Kang;Joong Mo Ahn;Heung Sik Kang
    • Journal of the Korean Society of Radiology
    • /
    • 제81권1호
    • /
    • pp.135-146
    • /
    • 2020
  • Purpose To describe magnetic resonance imaging (MRI) findings in 10 cases of Toxocara canis myelitis and to analyze these findings to aid in the diagnosis of this condition. Materials and Methods From June 2015 to March 2018, we retrospectively analyzed the electronic medical records and MR images of patients who were diagnosed with Toxocara canis myelitis. The analysis of the MR images was based on a discussion between an experienced spinal radiologist and a radiology resident. Results This study classified MRI findings into the following two types. Type 1 was defined as central and diffuse T2 high signal intensity on the axial plane, which was observed in 50% of all cases. All lesions showed avid enhancement, mostly in the posterolateral or posterior region (4 cases, 80%). Type 2 was defined as wedge-shaped or focal T2 high signal intensity in the posterolateral or posterior region and corresponded to the remaining 50% of the cases. In this case, the extent of the lesion was relatively small and contrast enhancement was observed in only one case. Conclusion This study revealed that various imaging findings could be observed in cases of Toxocara canis myelitis, and the findings were classified into two types.

Non-invasive MR Demonstration of the Fistula between Pancreatic Pseudocyst and Portal Vein: A Case Report (자기공명영상을 이용하여 비침습적으로 진단된 췌장 가성낭종과 간문맥 사이의 누공: 증례 보고)

  • Kim, Sung Min;Lee, Young Hwan;Kang, Ung Rae
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권2호
    • /
    • pp.171-175
    • /
    • 2014
  • Pancreatic pseudocyst rupture into the portal vein is a very rare complication and only three reported cases were confirmed using MRI. We report the case of a 50-year-old man with fistula formation between the pseudocyst and the portal vein, confirmed noninvasively by MRI. T2-weighted MR images and magnetic resonance cholangiopancreatography showed fluid signal intensity within the portal, superior mesenteric, and splenic veins, and a direct communication between the pseudocyst and the portal vein.

Remote Measurement for Automobile′s ECU Diagnostic Signals based on the PDA (PDA 기반의 차량 진단신호의 원격 계측)

  • 윤여흥;서지원;이현호;권대규;이영춘
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.279-282
    • /
    • 2002
  • In this paper, we present a new method for monitoring of ECU's self diagnostic signals of vehicle without wire. In order to measure the ECU's self diagnostic signals, the interfaced circuit is designed to communicate ECU and a designed display terminal according to the ISO, SAE regulation of communication protocol standard. A 80C196KC processor is used for communicating ECU's self diagnostic signals and the results are sent to PDA monitoring system. Software on PDA is developed to monitor the ECU's self diagnostic signals using the Embedded Visual C++ compiler in which RS232 port is programmed by half duplex method. The algorithms for measuring the ECU's self diagnostic signals are verified to monitor ECU's state. At the same time, the information to fix the vehicle's problem can be shown on the developed PDA software. The possibility for remote measurement of ECU self diagnostic signal using PDA is also verified through the developed systems and algorithms.

  • PDF

A Study on Selection of Optimal Imaging Diagnostic Device for Cerebral Angiography: Focusing on MRA, CTA, and DSA Imaging Diagnosis Devices (뇌혈관 검사 시 최적의 영상 진단장치 선정에 관한 연구: MRA, CTA, DSA, 영상 진단장치 중심으로)

  • Byun, Jung-Su;Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • 제11권7호
    • /
    • pp.637-645
    • /
    • 2017
  • The objective of this study was to find the optimum test device for the cerebral blood vessels by comparing and analyzing the SNR and CNR methods for images of three devices (i.e., MRA, CTA, and DSA). The study targeted 90 patients who underwent cerebral angiography from November 2016 to May 2017. The measuring parts were measured by using Rt MCA, Lt MCA, and ACA Image J. The results of quantitative analysis showed that the mean SNR of MRA, the CNR of MRA, the signal strength of MRA, the mean SNR of CTA, the CNR of CTA, the signal strength of CTA, the SNR of DSA, the CNR of DSA, and the signal strength of DSA were evaluated as 254.87, 178.13, 326.81, 74.75, 62.2, 356.66, 26.85, 25.89, and 4400.69, respectively (p<0.05). As a result, both SNR and CNR methods measured it in the order of MRA>CTA>DSA. Statistical significance was determined by using ANOVA analysis at p<0.05 and Bonferroni method was used as a post-hoc analysis SPSS. In conclusion, the results of this study revealed that the optimum imaging devices were MRA, CTA, and DSA after evaluating randomly selected patients with cerebrovascular disease.

Diagnosis of Insulation Deterioration in Cast-Resin Power Transformer using Acoustic Emission Techniques (음향방출법에 의한 몰드형 전력변압기의 절연열화 진단)

  • 이상우;김인식;이동인;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제14권6호
    • /
    • pp.35-42
    • /
    • 2000
  • In this paper, AE(Acoustic Emission) signals detected from the growth of the electrical tree in an epoxy resin under ac high-voltage application were analysed to diagnose the insulation deterioration of cast-resin power transformer. Frequency spectra of AE signals generated from the magnetizing and the load currents in the actual operating cast-resin power transformer of 500[kVA] under distribution system of 22.9[kV] were also analysed to distinguish the AE signals due to void discharges from the magnetic circuit noises in the core of the transformer. As the experimental results, we could distinguish the AE signals whether those signals were caused due to the void discharges or due to the magnetic circuit noises by analyzing the frequency spectrum of AE signals. The frequency spectra of AE signals generated from the cast-resin power transformer in operation due to both the magnetizing and the load currents appeared in the range of 40-120[kHz], but the frequency band of AE signals emitted from the void discharges in an epoxy resin sample was about 50[kHz] to 230[kHz].

  • PDF

An intelligent sun tracker with self sensor diagonosis system (자기 센서진단기능을 가진 지능형 태양추적장치)

  • 최현석;현웅근
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국해양정보통신학회 2002년도 추계종합학술대회
    • /
    • pp.452-456
    • /
    • 2002
  • The sensor based control system has some sensor fault while operating in the field. In this paper, a sensor fault detection and reconstruction system for a sun tracking controller has been researched by using polynomial regression and principle component analysis approach. The developed sun tracking system controls tow actuators with sensor based mechanism as on-line control and sun orbit information as off-line control, alternatively. To show the validity of the developed system, several experiments were illustrated.

  • PDF