• Title/Summary/Keyword: 자기호흡

Search Result 96, Processing Time 0.034 seconds

Assessment of Effect of Pulmonary Rehabilitation on Skeletal Muscle Metabolism by $^{31}P$ Magnetic Resonance Spectroscopy (호흡재활치료 전후 $^{31}P$ 자기공명분석법을 이용한 골격근대사의 변화에 관한 연구)

  • Cho, Won-Kyung;Kim, Dong-Soon;Choe, Kang-Hyeon;Park, Young-Joo;Lim, Tae-Hwan;Shim, Tae-Sun;Lim, Chae-Man;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1040-1050
    • /
    • 1997
  • Pulmonary rehabilitation has been known to improve dyspnea and exercise tolerance in patients with chronic lung disease, although it does not improve pulmonary function. The mechanism of this improvement is not clearly explained till now; however some authors suggested that the improvement in the skeletal muscle metabolism after the rehabilitation could be a possible mechanism. The metabolc changes in skeletal muscle in patients with COPD are characterized by impaired oxidative phosphorylation which causes early activation of anaerobic glycolysis and excess lactate production with exercise. In order to evaluate the change in the skeletal muscle metabolism as a possible cause of the improvement in the exercise tolerance after the rehabilitation, noninvasive $^{31}P$ magnetic resonance spectroscopy(MRS) of the forearm flexor muscle was performed before and after the exercise training in nine patients with chronic lung disease who have undertaken intensive pulmonary rehabilitation for 6 weeks. 31p MRS was studied during the sustained isometric contraction of the dominant forearm flexor muscles up to the exhaustion state and the recovery period. Maximal voluntary contraction(MVC) force of the muscle was measured before the isometric exercise, and then 30% of MVC force was constantly loaded to each patient during the isometric exercise. After the exercise training, exercise endurance of upper and lower extremities and 6 minute walking distance were significantly increased(p<0.05). There were no differences of baseline intracellular pH (pHi) and inorganic phosphate/phosphocreatine(Pi/PCr). After rehabilitation pHi at the exercise and the exhaustion state showed a significant increase($6.91{\pm}0.1$ to $6.99{\pm}0.1$ and $6.76{\pm}0.2$ to $6.84{\pm}0.2$ respectively, p<0.05). Pi/PCr at the exercise and the recovery rate of pHi and Pi/PCr did not show significant differences. These results suggest that the delayed intracellular acidosis of skeletal muscle may contribute to the improvement of exercise endurance after pulmonary rehabilitation.

  • PDF

Comparison of In-Phase and Opposed-Phase FMPSPGR Images in Breath-hold T1-weighted MR IMaging of Liver (호흡정지 T1 강조 간 자기공명영상에서 동위상 역위상 FMPSPGR 영상의 비교)

  • 김명진;김만득;정재준;이종태;유형식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.142-147
    • /
    • 1997
  • Purpose: To compare the effectiveness of the in-phase (IP) sequence and the opposed-phase (Op) sequence in the detection of focal hepatic lesions in the single breath-hold hepatic MR imaging with fast gradient T1-weighted pulse sequences. Materials and Methods: IP and OP T1-weighted breath-hold imaging was performed using fast gradient echo sequences in 45 patients referred for known focal hepatic lesions, in which 78 lesions were detected. Three blind readers independently reviewed the images for lesion detectability. The signal-to-noise ratio (SNR) of the liver, the lesion-to-liver contrast-to-noise ratio (CNR) and the liver-to-spleen CNR were also compared. A consensus was reached by three readers to determine which sequence is better in image quality. Results: On OP images, 61(78%), 61(78%), and 63(89%) lesions were correctly identified for reader 1, 2 and 3, respectively. On IP images, 66(85%), 65(83%), and 65(93%) lesions were detected for each reader, respectively. When two image sets were combined, 71(91 %), 69(88 %), and 76(97%) lesions respectively were detected for each reader. In cases of hepatocellular carcinoma, liver-to-Iesion CNR was greater on the OP images(p (0.05), but in other lesions significant difference was not demonstrated. Liver-to-spleen CNR was higher on OP images(p ( 0.1), but the SNR of the liver was higher on the IP images. Conclusion: Use of both IP and OP imaging can be helpful to avoid erroneous missing of some focal hepatic lesions.

  • PDF

Analysis on Psychological Self-regulation and Arousal Variation of Actors on Performance (공연 시 배우의 각성변화와 심리적 자기조절 분석)

  • Hong, Kil-Dong;Lee, Hong-Sik;Lee, Hyung-Kook;Oh, Jin-Ho;Lee, Ki-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.12
    • /
    • pp.176-189
    • /
    • 2008
  • The purpose of this study was to analyze self-regulation about changing heart rate and perceived arousal variation when actors start their performance. Object of this study were 5 actors who belong to the theater selected using the purposive sampling method. This study used a measuring instrument of heart rate to measure arousal status, used behavior observation paper to observe and record self-regulation behavior and executed personal consultation after ending performance. There was graph mad by variation transition which calculated average and standard deviation about variation of heart rate each time of performance. The results of this study were as follows. First, there were high variation of awake level that actor's heart rates were rising before starting performance and the most high level of arousal was from 20minutes to 5minutes before starting performance. Second, there were self-regulation behaviors appeared such as deep breathing, breath controling, self talking, talking with other actors, concentrating an script, going to toilet, smoking, checking closes before starting performance. Third, when performance start, actors used psychological self-regulational method such as relaxation, self concentration, confidence reinforcement, coping with state or accommodation for controling raised arousal status.

Assessment of subjective symptoms by 60Hz magnetic field in electromagnetic hypersensitivity (60Hz 자기장에 대한 과민 증후군의 자각증상 원인 평가)

  • Yang, Dong-In;Nam, Ki-Chang;Kwon, Min-Kyung;Kim, Deok-Won
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.721-732
    • /
    • 2010
  • As increasing of electrical device usage, social concerns about the possible effects of 60Hz electromagnetic fields (EMF) on human health have increased. The number of people with self-attributed electromagnetic hypersensitivity (EHS) who complain of subjective symptoms such as headache, insomnia etc. also increased. However, we don't know whether the EHS results from psychological factor or real perception to the electromagnetic field. In this study, we simultaneously investigated physiological changes(heart rate, respiration rate, heart rate variability, alpha and beta waves in EEG), subjective symptoms and perception accuracy to assess origins of subjective symptoms according to the EMF exposure. Experiment consists of real and sham sessions and 60Hz 12.5uT magnetic field was on(real) or off(sham) to 15 EHS and 16 nonEHS. As the results, EMF exposure did not have any effects on physiological parameters or subjective symptoms for both groups. There was also no evidence that EHS group perceived the EMFs correctly than the control group. Therefore, the origins of subjective symptoms is not the 60Hz magnetic field but psychological factors.

  • PDF

Performance evaluation by flow channel effect for a passive air-breathing Direct Methanol Fuel Cell (수동급기 직접 메탄올 연료전지의 유로에 따른 성능 평가)

  • Chang, Ikw-Hang;Ha, Seung-Bum;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.45-48
    • /
    • 2008
  • This paper presents a passive air-breathing direct methanol fuel cell (DMFC) which has been designed and tested. The single cell is fuelled by methanol vapor that is supplied through flow channel from a methanol reservoir at the anode, and the oxygen is supplied via natural air-breathing at the cathode. The methods for supplying the methanol vapor to the single cell were parallel channel and chamber. This research investigates various methods to identify the effects of using flow channels for providing the methanol vapor at the anode, and the opening ratio between the inlet and outlet ports for the methanol flow at the anode. The best flow channel condition for passive DMFC was a chamber, and the opening ratio was 0.8. Under these conditions, the peak power was 10.2mW/$cm^2$ at room temperature and ambient pressure. The key issues for the Passive DMFCs for using methanol vapor are that sufficient methanol needs to be supplied using a large as possible opening ratio. However, it is shown that the performance of the passive DMFC, which has a channel at the anode,is low due to the low differential pressure and insufficient methanol supply rate.

  • PDF

Ferucarbotran-Enhanced Hepatic MRI at 3T Unit: Quantitative and Qualitative Comparison of Fast Breath-hold Imaging Sequences (간의 3T 자기공명영상에서 초상자성산화철 조영증강 급속호흡정지영상기법들간의 양적 및 질적 비교평가)

  • Cho, Kyung-Eun;Yu, Jeong-Sik;Chung, Jae-Joon;Kim, Joo-Hee;Kim, Ki-Whang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.31-40
    • /
    • 2010
  • Purpose : To compare the relative values of various fast breath-hold imaging sequences for superparamagnetic iron-oxide (SPIO)-enhanced hepatic MRI for the assessment of solid focal lesions with a 3T MRI unit. Materials and Methods : 102 consecutive patients with one or more solid malignant hepatic lesions were evaluated by spoiled gradient echo (GRE) sequences with three different echo times (2.4 msec [GRE_2.4], 5.8 msec [GRE_5.8], and 10 msec [GRE_10]) for $T2^*$-weighted imaging in addition to T2-weighted turbo spin echo (TSE) sequence following intravenous SPIO injection. Image qualities of the hepatic contour, vascular landmarks and artifacts were rated by two independent readers using a four-point scale. For quantitative analysis, contrast-to-noise ratio (CNR) was measured in 170 solid focal lesions larger than 1 cm (107 hepatocellular carcinomas, nine cholangiocarcinomas and 54 metastases). Results : GRE_5.8 showed the highest mean points for hepatic contour, vascular anatomy and imaging artifact presence among all of the subjected sequences (p<0.001) and was comparable (p=0.414) with GRE_10 with regard to lesion conspicuity. The mean CNRs were significantly higher (p<0.001) in the following order: GRE_10 ($24.4{\pm}14.5$), GRE_5.8 ($14.8{\pm}9.4$), TSE ($9.7{\pm}6.3$), and GRE_2.4 ($7.9{\pm}6.4$). The mean CNRs of CCCs and metastases were higher than those of HCCs for all imaging sequences (p<0.05). Conclusion : Regarding overall performances, GRE using a moderate echo time of 5.8 msec can provide the most reliable data among the various fast breath-hold SPIO-enhanced hepatic MRI sequences at 3T unit despite the lower CNR of GRE_5.8 compared to that of GRE_10.

Usefulness of Breath-hold T2-weighted MR Imaging in Patients with Myocardial Infarction: Comparison with Delayed Enhancement (심근경색을 가진 환자에서 호흡정지 T2강조 자기공명영상의 유용성: 지연 조영증강 영상과의 비교)

  • Choi Sang Il;Kang Sung-Kwon;Ryu Won Hee;Lim Cheong;Choh Joong Haeng;Lee Whal;Jeong Jin-Wook;Park Jae-Hyung;Lee Kyung Won
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.132-136
    • /
    • 2003
  • Purpose : To evaluate the usefulness of breath-hold T2-weighted MR imaging in patients with myocardial infarction. Materials and Methods : We investigated 11 patients with myocardial infarction who shown delayed enhancement on MR imaging. Infarcted myocardium on T2-weighted MR imaging was classified as high, iso, and low signal area comparing with normal myocardium. The intensity and transmural extent of infracted myocardium was also analyzed. On the basis of clinical information, the stage of infracted myocardium on T2-weighted MR imaging was assessed. Results : It was observed high signal area in 12 segments of 5 patients, low in 12 segments of 6 patients on T2-weighted MR imaging. The high signal intensity of infarcted myocardium was shown as $175{\pm}9\%$ comparing with that of the normal myocardium, low signal intensity as $73{\pm}5\%\;(p\;<\;0.05)$. In the evaluation of transmural extent, the high signal areas on T2-weighted MR imaging were larger than infarct area on delayed enhancement imaging $(100\%\;vs.49\%{\pm}17\%)$, whereas low signal areas on T2-weighted MR imaging correlated. High signal area was visualized on T2-weighted MR imaging within 11 days, whereas low-signal area was seen after 7 months. Conclusion : Breath-hold T2-weighted MR imaging is useful in the evaluation of stage as well as edema and fibrous scar in patients with myocardial infarction.

  • PDF

Paradoxical Upper Airway Obstruction and Central Sleep Apnea Developed After Anterior Cervical Spine Fusion (전방경추융합술 후 발생한 역설상기도폐쇄 및 중추성 수면 무호흡)

  • Lee, Sang Haak;Choi, Young Mee;Park, Ye Ree;Kang, Ji Ho;Kim, Young Kyoon;Kim, Kwan Hyoung;Song, Jeong Sup;Park, Sung Hak;Moon, Hwa Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.3
    • /
    • pp.295-298
    • /
    • 2005
  • We report a case of a 48-year-old man with a paradoxic upper airway obstruction and central sleep apnea that developed after an anterior cervical spinal fusion. Nine months before being admitted to this hospital, he was diagnosed with a herniated intervertebral disc between the 5th and 6th cervical spine, and the first operation was carried out. Two months later, a pseudoarthrosis has developed and a second operation, an anterior interbody fusion of the C5 and C6 using autogenous strut bone graft, was performed. After the second operation, he began to complain of snoring, excessive daytime sleepiness, insomnia, and a bizarre sound heard near the upper airway during breathing. Nasopharyngoscope and magnetic resonance imaging disclosed a paradoxical narrowing of the nasopharynx during expiration. On the overnight polysomnography, the apnea index was 8.7/h (central apnea, 7.0/h; obstructive apnea, 1.7/h). Nasal continuous positive airway pressure was applied, but he complained of pressure-intolerance, and laser-assisted uvulopalatoplasty was then performed. Two months after surgery, clinical symptoms as well as the apneas had improved markedly. We suggest that this paradoxic upper airway obstruction might be associated with the anterior cervical spinal surgery even though the mechanism is unclear. This case also emphasizes that an upper airway obstruction can contribute to the development of central sleep apnea.

Detrended Fluctuation Analysis of Sleep Electroencephalogram between Obstructive Sleep Apnea Syndrome and Normal Children (소아기 수면무호흡증 환자와 정상 대조군 수면 뇌파의 탈경향변동분석)

  • Kim, Eui-Joong;Ahn, Young-Min;Shin, Hong-Beom;Kim, Jong-Won
    • Sleep Medicine and Psychophysiology
    • /
    • v.17 no.1
    • /
    • pp.41-49
    • /
    • 2010
  • Unlike the case of adult obstructive sleep apnea syndrome (OSAS), there was no consistent finding on the changes of sleep architecture in childhood OSAS. Further understanding of the sleep electroencephalogram (EEG) should be needed. Non-linear analysis of EEG is particularly useful in giving us a new perspective and in understanding the brain system. The objective of the current study is to compare the sleep architecture and the scaling exponent (${\alpha}$) from detrended fluctuation analysis (DFA) on sleep EEG between OSAS and normal children. Fifteen normal children (8 boys/7 girls, 6.0${\pm}4.3$2.2 years old) and twelve OSAS children (10 boys/2 girls, 6.4${\pm}4.3$3.4 years old) were studied with polysomnography (PSG). Sleep-related variables and OSAS severity indices were obtained. Scaling exponent of DFA were calculated from the EEG channels (C3/A2, C4/A1, O1/A2, and O2/A1), and compared between normal and OSAS children. No difference in sleep architecture was found between OSAS and normal controls except stage 1 sleep (%) and REM sleep latency (min). Stage 1 sleep (%) was significantly higher and REM latency was longer in OSAS group (9.3${\pm}4.3$4.3%, 181.5${\pm}4.3$59.9 min) than in controls (5.6${\pm}4.3$2.8%, 133.5${\pm}4.3$42.0 min). Scaling exponent (${\alpha}$) showed that sleep EEG of OSAS children also followed the 'longrange temporal correlation' characteristics. Value of ${\alpha}$ increased as sleep stages increased from stage 1 to stage 4. Value of ${\alpha}$ from C3/A2, C4/A1, O1/A2, O2/A1 were significantly lower in OSAS than in control (1.36${\pm}4.3$0.05 vs. 1.41${\pm}4.3$0.04, 1.37${\pm}4.3$0.04 vs. 1.41${\pm}4.3$0.04, 1.37${\pm}4.3$0.05 vs. 1.41${\pm}4.3$0.05, and 1.36${\pm}4.3$0.07 vs. 1.41${\pm}4.3$0.05, p<0.05). Higher stage 1 sleep (%) in OSAS children was consistent finding with OSAS adults. Lower $'{\alpha}'$ in OSAS children suggests decrease of self-organized criticality or the decreased piling-up energy of brain system during sleep in OSAS children.

  • PDF

Effectiveness of 32-element Surface Coil Array for Accelerated Volume-Targeted Breath-Hold Coronary MRA (체적 지향형 호흡정지 자기공명 조영술의 가속화에 대한 32채널 코일 어레이의 효용성)

  • Lee, Hyun-Yeol;Suh, Jin-Suck;Park, Jae-Seok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.137-145
    • /
    • 2009
  • Purpose : To compare 12 and 32-element surface coil arrays for highly accelerated coronary magnetic resonance angiography (MRA) using parallel imaging. Materials and Methods : Steady state free precession coronary MRA was performed in 5 healthy volunteers at 1.5 T whole body MR scanner using both 12 and 32-element surface coil arrays. Left anterior descending and right coronary artery data sets were acquired for each volunteer. Data sets were sub-sampled for parallel imaging using reduction factors from 1 to 6. Mean geometry factor (g-factor), maximum g-factor, and artifact level were calculated for each of the two coil arrays. Results : Over all reduction factors, the mean and maximum g-factors and artifact level were significantly reduced using the 32-element array compared to the 12element array (P << 0.1). The mean g-factor was sensitive to the imaging orientations of coronary arteries while the maximum g-factor and artifact level were independent of orientation. Conclusion : The 32-element surface coil array significantly improves artifact and noise suppression for highly accelerated coronary MRA using parallel imaging. The increased acceleration factors made feasible with the 32-element array offer the potential to enhance spatial resolution or increase volumetric coverage for 3D coronary MRA.

  • PDF