Magnetic Switch Auto Control Method of the High-Voltage Pulse Power Supply (고압펄스 전원장치용 자기스위치 자동제어 방법)

  • Kim, Soo-Hong;Kim, Byung-Seob;Kim, Hyung-Joon;Kwon, Byung-Ki;Choi, Chang-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.117-118
    • /
    • 2010
  • 본 논문은 저온플라즈마를 이용한 탈황탈질 시스템에서 고압펄스압축을 위해 사용되는 자기스위치의 자동제어방법에 관한 것이다. 자기스위치를 부하변동에 따라 자동제어 함으로써 플라즈마 반응기에 전달되는 에너지의 전달효율을 최적화 시킬 수 있다.

  • PDF

Development of Individually Adapted Electromagnetic Therapy System in Incontinence (환자 맞춤형 전자기장 요실금 치료 시스템 개발)

  • Noh, Si-Cheol;Kang, Kyu-Hong;Lee, Jeong-Seok;Min, Kwon-Sik;Kwon, Jang-Woo;Choi, Heung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.4
    • /
    • pp.51-59
    • /
    • 2008
  • Incontinence is the urination disorder as the leakage of urine without her own volition and the woman's representative disease which reduce the life quality. The electromagnetic therapy has high possibility of development cause it has no needs of operant exercise, no arousing of shame and impossibility of infection. But, it has improvement points such as uniformity of the treatment protocol, patient dependance and absent of patient monitoring system. With these demands, the system which stimulate the pelvic flaw muscle with electromagnetic and monitoring the patient status during the therapy is proposed, in this study. And individually adapted electromagnetic therapy system for incontinence patient is also suggested. The proposed system consisted of electromagnetic generation device, cooling device, treating chair, patient monitoring device with pulsation and control software. The simulation for high power system and evaluation confirm was performed. With the development of control software, the convenience of using and maintenance are ensured and the patient adapted therapy protocol is applied. The developed patient adapted electromagnetic therapy system with monitoring device is regarded as the patient affinitive treating method by reducing the riskiness, improving the efficiency with patterned protocol and pre/post therapy. These results, in this study, can bring the safe and organized treatment method to incontinence patients and can lead the variable study for electromagnetic therapy in incontinence.

In-Band Full-Duplex Wireless Communication Using USRP (USRP 장치를 이용한 동일대역 전이중 무선통신 연구)

  • Park, Haeun;Yoon, Jiyong;Kim, Youngsik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.3
    • /
    • pp.229-235
    • /
    • 2019
  • The implementation of an in-band full-duplex wireless communication system is demonstrated in this study. In the analog/RF domain, the self-interference(SI) signal is reduced using a separate antenna for the transmitter and receiver paths, and most of the SI signal is canceled in the digital domain. A software defined radio(SDR) is used to implement the in-band full-duplex wireless communication system. The USRP X310 device uses transmitting and receiving antennas. By adjusting the gain of the transmitting and receiving ends of the SDR device, the magnitude of the SI signal entering the receiving antenna, and the size of the received signal from the outside, are both set to -64 dB. To verify the in-band full-duplex wireless communication performance, the source data is image and orthogonal frequency-division multiplexing is used for modulation. A WiFi standard frame with a carrier frequency of 2.67 GHz and bandwidth of 20 MHz is used. In the received signal, the SI signal is canceled by digital signal processing and the SI signal is attenuated by up to 34 dB. OFDM demodulation was impossible when the SI signal was not removed. However, the bit error rate is reduced to $2.63{\times}10^{-5}$ when the SI signal is attenuated by 34 dB, and no error is detected in the 100 Mbit data output as a result of passing through the Viterbi decoder.

Helmholtz Coil and Performance of Magnetic Compass (인공자장발생장치와 자기 컴퍼스의 성능)

  • Ahn, Young-wha;Jeong, Kong-heun;Ahn, Jang-young;Sin, Hyeong-il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.19 no.2
    • /
    • pp.111-116
    • /
    • 1983
  • In order to furnish the fundamental data for the domestic production of magnetic compass and the prescription of standardization about it in Korea, authors made the helmholtz coil and investigated the characteristics of them. Subsequently, the damping curves of T190 and T165 compasses in the helmholtz coil were measured and analyzed the performance of those compass. The results obtained are as follows; 1. The relation between electric current (I sub I) to flow in the helmholtz coils, that the thickness of coil is 1mm, diameter 1m, winding number 117, and intensity of magnetic field is presented as follows. Vertical magnetic force: Z(Gauss)=0.34+1.506 I sub(i) Horizontal magnetic force: H(Gauss)=0.183+1.506 I sub(i) 2. Period of T190 compass is longer than T165 compass in all horizontal magnetic force. In the amplitude, the former is larger than the latter above 0.08 Gauss, but this phenomenon is opposed to that below 0.08 Gauss. 3. As the porizontal magnetic force is intensive, period of magnetic compass is short, amplitude is large, and damping degree and damping factor are small. The time elapsed to the principal points of damping curve is proportional to the -0.65 power of the horizontal magnetic force.

  • PDF

Basic RF Coils Used in Multi-channel RF Coil and Its B1 Field Distribution for Magnetic Resonance Imaging System (자기공명영상 촬영 장치에서 다채널 RF Coil에 이용되는 기본 구조 RF Coil의 B1 Field 분석)

  • Kim, Yong-Gwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4891-4895
    • /
    • 2010
  • RF coil is an important component of the Magnetic Resonance Imaging (MRI) system and the performance of RF coil is one of major factors for high SNR images. Sensitivity and RF field uniformity are parameters for evaluating RF coil performance. Since the B1 field is induced by RF coil, MR signal is strongly affected by RF coil structure and arrangement. In receiving MR signal, the RF coil sensitivity to MR Signal is also determined by the induced B1 field of RF coil. Therefore, the spatial distribution of B1 field must be verified. In this work, we performed computer simulation of the basic RF coil structures using Matlab and verified their sensitivity and uniformity through their B1 field distribution. This work will be useful for the advanced multi-channel RF coil design.

Development and application of the magnetic field device for single crystal growth (자기장 단결정 성장장치의 개발과 적용)

  • Kim, Shin Ae;Cho, Sang-Jin;Magay, Elena;Ryu, Sun-Young
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.23 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • The three-dimensional structure of the proteins, including the location of the hydrogen atoms can be analyzed by using neutron diffraction. In order to grow single crystals for neutron diffraction experiments, we developed a simple magnetic field device with the commercial magnets and succeeded in growing hen egg-white lysozyme single crystals of more than 1 $mm^3$ in volume using this device. The crystals grown with a magnetic field were larger and had perfect transparency, whereas the crystals grown without a magnetic field had micro-cracks. The result of the X-ray measurement showed a good resolution and small mosaicity for the crystals grown in the presence of a magnetic field.

Fashionable Technology in Contemporary Fashion (현대패션에서 패셔너블 테크놀로지 연구)

  • Lee, Seo-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.1
    • /
    • pp.246-253
    • /
    • 2009
  • Technology and fashion are not as distant from each other as it might first seem. Early wearables were functional but awkward to wear and to look at. Today wearables are rapidly rising to meet the fashion world on its own terms by producing garments that are both stylish and comfortable. Personalization of wearables allows for new modes of self-expression, which is an essential factor in making fashion items that appeal to the public. Embedded technologies in the garment and the functionalities integrated into the electronic textiles influence the ‘wearability', comfort and the aesthetic of a fashionable wearable. Considering these factors is an essential part of the design process when creating user-centered fashionable wearables. Designers have to have a comprehensive understanding of the purpose, the user, the interaction, and in commercial applications, the right price point. An appealing design in combination with an intuitive interface will make for a successful fashionable wearable.

자기 공명 영상술의 원리와 최근 연구 현황

  • 조장희;김영근
    • 전기의세계
    • /
    • v.38 no.8
    • /
    • pp.19-25
    • /
    • 1989
  • 현재 전세계적으로 퍼져있는 NMR-CT 시스템의 수를 살펴보면 약 370여기가 설치.운영되고 있으며 앞으로 계속 늘어날 전망이다. 국내에서는 1988 한국과학기술원과 금성통신에 의해 자체 개발된 2.0 Tesla 강자장 시스템이 최초로 서울대학병원에 설치 가동된 이래 여러병원에서 시스템들이 설치중에 있다. 첨단의로 진단장치로서의 핵자기 공명 영상법은 그 영상을 통하여 기존의 진단 장치보다 우월함을 증명하고 있으며 초음파 검사나 동위원소 검사 및 X선 전산화 단층 촬영술들을 장점을 두루 지니면서 그 영상법의 다양성 때문에 앞으로의 연구 및 발전에 대한 전망은 아주 밝다고 할 수 있다. 따라서 앞으로의 종합 영상 의료 진단 장치는 이 NMR-CT가 중심이 되어 발전할 것이라고 단언해도 무리한 생각은 아닐 것이다.

  • PDF

A Study of high frequency generator for large diameter (대구경을 이용한 초고주파 발생장치 연구)

  • Kim, Won-Sop
    • Proceedings of the KIEE Conference
    • /
    • 2008.05a
    • /
    • pp.135-136
    • /
    • 2008
  • 본 연구에서는 100GHz 이상의 높은 주파수에서 발진하는 초고주파 발생장치의 연구를 하였다. 전자파를 이용한 발진장치에서 대구경 후진파에 입사하는 전자빔의 크기와 상태를 좋게 하여 동작특성을 증진시키는 실험을 하여 그에 따른 변화 및 결과를 조사하였다. 출력의 증대와 방사할 때의 크기 및 그에 따른 주파수 교정, 그리고 마이크로파의 발진모드 특성을 분석하였다. 이는 주기의 크기에 따른 발진 주파수와의 관계를 분석하였으며 자기장의 변화 등 여러 가지 형태의 조건에 따른 결과를 나타내었다.