• Title/Summary/Keyword: 자구구조

Search Result 52, Processing Time 0.022 seconds

Thermal Stability and the Effect of Substrate Temperature on the Structural and Magnetic Properties of Pd/Co Multilayer Films (Pd/Co 다층박막의 구조 및 자기적 특성에 미치는 기판온도 및 열적안정성에 관한 연구)

  • 허용철;김상록;이성래;김창수
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.4
    • /
    • pp.298-304
    • /
    • 1993
  • The effects of the substrate temperature and the Pd underlayer on the structure and the magnetic properties of Pd/Co multilayer films prepared by the thermal evaporation were studied. As the substrate temperature increases up to $150^{\circ}C$, the crystallinity of sublayers, (111) texture and the interface sharpness of Pd/Co multilayers were improved due to the enhanced mobility of adatoms. As results of that, the perpendicular and surface anisotropy energies were increased but the coercivity was decreased because the pinning sites of domain wall decreased due to the grain growth. The grain size of the multilayers increased with Pd underlyer thickness. Thermal degradation was enhanced at above $200^{\circ}C$ due to interdiffusion at the Pd/Co interface. The intensity of the main diffraction peak rapidly decayed in the initial stage of aging and then decreased slowly. The rapid change of the intensity in the initial stage was speculated to be due to the structural relaxation phenomena and the later stage change was due to the interdiffusion. The activation energy for the interdiffusion in Pd4/Co1 multilayers was 14.9 KCal/mole.K.

  • PDF

Formation of a Narrow Domain Wall Using Local Exchange Coupled System (국소적 교환상호작용을 이용한 좁은 자벽의 생성)

  • You, Chun-Yeol
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.4
    • /
    • pp.221-225
    • /
    • 2005
  • Formation of a narrow magnetic domain wall is demonstrated by micromagnetics simulations. It is found that the domain wall width can be shrunk in a local exchange coupled system. The local exchange coupled system means that only a part of a ferromagnetic layer has an exchange coupling with another ferromagnetic layer. The system can be considered as two parts in the lateral dimensions: one is an exchange coupled region and another is a free region. Since the two regions have quite different local switching fields, the domain wall will be formed at the interface between the two regions at moderate field ranges.

Necessity for Establishing International Certification Authority System for Global Electronic Commerce (인증 관련 주요 국제기구 및 국가인증제도 현황 분석)

  • Lee, Ho-Gun;Park, Seung-Lak;Yoon, Young-Han
    • International Commerce and Information Review
    • /
    • v.1 no.2
    • /
    • pp.123-143
    • /
    • 1999
  • 전자상거래는 비대면(非對面) 거래로 모든 제반과정이 진행되기 때문에 상대에 대한 신뢰성의 문제가 크며, 거래 당사자와 거래 내역에 대한 입증을 해줄 인증기관이 필요하게 된다. 현재 미국의 베리사인 등 사설인증업체가 국내전자상거래 업체의 인증업무를 담당하고 있는 실정이다. 또한, 인중은 필연적으로 관련 기술의 표준화가 수반되는데 이에 대한 국내기술이 미흡하므로 국제동향을 고려한 국내인증기술의 개발이 시급하다. 특히, 글로벌 전자상거래에서는 인증기관에 대한 문제가 더욱 절실한데 문제는 어떠한 형태로 어떤 기관이 주축이 되어 인중체계를 구축하는가 하는 것이다. 현재, 인증체계는 네트워크 방식, 계층구조, 혼합형의 세가지가 논의되고 있으며, 각각의 장단점이 존재하므로 이에 대한 심도있는 논의가 필요하다. 이러한 체계는 국가별로 상이할 수 있지만, 문제는 글로벌 전자상거래를 활성화하기 위해서는 보다 일관된 형태의 인증체계 구축이 필요하다는 점이다. 현재까지 이와 관련한 심도있는 논의는 미흡한 실정이며, 미국 EU 등 일부국가와 UNCITRAL, OECD, ICC 등 관련 기구에서 다양한 의견을 제시하고 있는 상태이다. 이러한 문제는 단시일 내에 해결되기는 어려울 것으로 보인다. 다만, 단기적으로는 관련국가들간의 상호인증을 통한 해결이 가능할 것으로 판단되며, 이러한 상호 인증이 전세계적으로 확산되어감에 따라 글로벌 전자상거래를 위한 인증체계가 심도있게 논의될 것으로 판단된다. 이와 관련하여 상호 인증과 관련한 국내관련 법제의 보완이 필요하며, 실제로 인증을 담당할 관련 당사자들의 자구노력이 매우 시급한 시정이라 하겠다.

  • PDF

Evacuation characteristic measurement of anti-suck back centering by mini vacuum system (미니 진공시스템을 이용한 역류방지 센터링의 배기 특성 측정)

  • Hong, Gwang-Gi;Go, Seok-Il;Do, U-Ri;Yang, Won-Gyun;Ju, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.05a
    • /
    • pp.255-256
    • /
    • 2009
  • The anti suck back centering (ASBC) for preventing backflow of oil for oil rotary pump was designed in the power failure. To evaluate the evacuation characteristics, we manufactured the mini vacuum system, personal computer, AD converter (National instrument, NI-6009), and automatic controller with touch panel for a basis. In this study, we measured the evacuation characteristics of ABSC and analyzed the flow field of viscous flow regime using a commercial software, CFD-ACE+. Also, the leakage of the advaced ASBC for leveling was measured.

  • PDF

Effects of Residual Magnetization on MEL Non-destructive Inspection of Gas Pipeline (가스관의 자속누설탐사에서 잔류자화의 영향에 관한 연구)

  • Jang, Pyung-Woo
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.4
    • /
    • pp.143-148
    • /
    • 2004
  • Effects of residual flux density M$_{res}$ and number of inspection on the detection voltage and flux density B of the gas pipeline were investigated in MFL inspection, which is widely used for the non-destructive inspection in a gas pipeline. A simulation equipment composed of the magnetizer and iron ring attached on an aluminum disc was constructed instead of a huge gas pipeline facility. With this system. the iron ring could be perfectly demagnetized and signals from the bolt screw stuck on the disc could be clearly detected so that the effects of M$_{res}$S and the inspection number on the detection voltage and B of iron ring were effectively investigated. With increasing the number of inspection, M$_{res}$, B of the iron ring and the detection voltage decreased and then kept at constant values while final M$_{res}$ increased with increasing initial M$_{res}$. If inspection condition were kept unchanged, the detection voltage was proportional to the last M$_{res}$ of the iron ring instead of B. This was probably due to magnetic hysteresis of the iron ring inherited from magnetic domain so that consideration on the magnetic hysteresis was inevitable in the analysis of MFL signal from defects of a gas pipeline. A new inspection scheme using the magnetizer with reversed magnetization in the subsequent inspection was proposed from the result that a high detection voltage could be obtained in the first inspection of gas pipeline with positive M$_{res}$.

Aerodynamic Characteristics of Giromill with High Solidity (높은 솔리디티를 갖는 자이로밀의 공기역학적 특성)

  • Lee, Ju-Hee;Yoo, Young-So
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1273-1283
    • /
    • 2011
  • A 3-dimensional unsteady numerical analysis has been performed to evaluate the aerodynamic characteristics of a Giromill. Generally, the structure of a Giromill is simple and therefore easy to develop. In addition, the high solidity of the Gironmill helps improve the self-starting capacity at a low tip speed ratio (TSR). However, contrary to the Darrieus wind turbine which has a TSR of 4-7, a Giromill has a low TSR of 1-3. In this study, the aerodynamic characteristics of the Giromill are investigated using computational fluid dynamics (CFD). Three straight-bladed wings are used, and the solidity of the Giromill is 0.75. In contrast to a Darrieus wind turbine having low solidity, the Giromill shows a sudden decrease in the aerodynamic performance because of the interference between the wings and an increase in the drag on the wings in the downstream direction where wind flow is significantly reduced. Consequently, the aerodynamic performance decreased at a TSR value lower than 2.4.

X-ray Magnetic Circular Dichroism

  • Kim, Jae-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.81-81
    • /
    • 2012
  • XMCD (X-ray Magnetic Circular Dichroism)는 원형 편광 X-선의 helicity 방향이 시료의 자화 방향과 평행, 또는 반평행할 때 시료의 색이 바뀌는 현상, 즉 흡수율이 달라지는 현상이다. XMCD측정이 가지는 장점은 첫째, 이 실험이 특정 원소의 흡수선에서 이루어지기 때문에 시료 전체에서 특정 원소에 의한 자기적 성질을 분리해서 측정할 수 있을 뿐만 아니라, 같은 원소라 하더라도 다른 화학적 환경에 있는 원자들의 자기적 성질의 분리가 가능하다는 점이다. 이러한 성질로 인해 XMCD는 다른 원소들로 이루어진 다층 박막(GMR, TMR 등의 자기저항박막 구조물)의 층별 자기적 성질 연구 및 신자성물질의 자기적 성질의 고유성 연구에 많이 이용되었다. XMCD가 가지는 두 번째 장점은 sum rule을 통하여 자기 모멘트의 두 가지 성분인 궤도 모멘트(orbital moment)와 스핀 모멘트(spin moment)의 구별이 가능하다는 점이다. 이러한 장점은 수직자기 메모리 연구 및 스핀과 격자 간의 상호작용이 중요한 역할을 하는 다강체 등의 연구에 많이 이용되어 왔다. XMCD 측정이 또 다른 장점이 될 수 있는 것은 표면에 대단히 민감하다는 점이다. VSM, SQUID 등의 측정방법으로는 시료의 체적이 대단히 작은 수 ${\AA}$ 정도의 초박막에 대해서는 충분한 민감도를 가질 수 없다. 그러나, XMCD의 측정 깊이는 수십 ${\AA}$ 정도로 표면에 민감하기 때문에 이러한 초박막에 대해서도 충분한 민감도를 가질 수 있어서 SMOKE(Surface Magneto-Optical Kerr Effect)와 표면 자성연구에 있어서 독보적인 장치로 이용되어 왔다. 이러한 장점으로 인해 XMCD는 1990년대 이후 분광학적으로 활발히 이용되어 왔을 뿐만 아니라, 대단히 빠르고 신호가 큰 현상이기 때문에 최근 들어서는 자구(magnetic domain) 관찰 등을 목적으로 한 자기 현미경 및 자기현상의 동역학 연구에도 많이 응용되고 있다. 이 강연에서는 이러한 X-선 자기 원형 이색성 현상의 원리 및 실험 방법 등을 설명하겠다. 또한 몇 가지 X-선 자기 원형 이색성을 이용한 최근 몇 가지 연구도 소개하려 한다.

  • PDF

Formation of Induced Anisotropy in Amorphous Sm-Fe Based Alloy Thin Films (비정질 Sm-Fe계 합금 박막의 유도자기이방성 형성)

  • 송상훈;이덕열;한석희;김희중;임상호
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.5
    • /
    • pp.261-269
    • /
    • 1998
  • Induced anisotropy with the energy of $6{\times}10^4\; J/m^3$ is obtained in amorphous Sm-Fe based thin films which are fabricated by rf magnetron sputtering under a magnetic field of 500~600 Oe. Compared with conventional thin films, the anisotropic thin films exhibit a similar "saturation" magnetostriction, but show a very large anisotropy in magnetorstiction which is of significant practical importance due to increased strain at a particular direction. It is shown from a systematic investigation over a wide composition range for binary Sm-Fe alloys that anisotropy is also induced, though small, during a normal sputtering procedure due to the stray field, and the largest anisotropy is observed in the composition range of 25~30 at.% Sm. Furthermore, induced anisotropy is also found to be formed by magnetic annealing, but the anisotropy energy is much smaller than that by magnetic sputtering. This may be because the volume diffusion by which atoms move during magnetic annealing to from induced anisotropy is much slower than the surface diffusion which is expected to be a dominant factor during magnetic sputtering.puttering.

  • PDF

Effects of Deposition Conditions on Magnetic Properties of SmCo/Cr (스퍼터 제조조건에 따르는 SmCo/Cr 박막의 자기적 특성에 관한 연구)

  • 나태준;고광식;이성래
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.6
    • /
    • pp.312-320
    • /
    • 1999
  • Effect of deposition conditions on the magnetic properties of SmCo/Cr prepared by a RF magnetron sputtering method was studied. We obtained the maximum coercivity of 3.2 kOe in the sample of Cr(50 nm)/SmCo(40 nm, 50W, 20 mT)/Cr(150 nm, 100 W, 30 mT). The coercivity of the SmCo/Cr depends largely on the roughness of the Cr underlayer and the composition of SmCo. The roughness of the Cr underlayer increased with increasing the Ar pressure and thickness, and promoted the isolation of SmCo grains which resulted in an enhanced coercivity. The composition of the SmCo was changed with RF power and Ar pressure due to the mass difference between Sm and Co and the resputtering phenomena. The maximum coercivity was obtained in the composition of about 20 at.% Sm. The mechanism of magnetization reversal of the present SmCo films changed from domain wall motion to domain rotation as the RF power and the Ar pressure increase. This was though to be due to the defects, such as the roughness of Cr surface, porous column boundaries etc., which inhibit domain wall movement.

  • PDF

Development of Magnetic Sensor for Measurement of the Cable Tension of Large Scale Bridge (대형교량 케이블 장력 측정을 위한 자기센서 개발)

  • Park, Hae-Won;Ahn, Bong-Young;Lee, Seung-Seok;Kim, Jong-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.339-344
    • /
    • 2007
  • Safety of large scale cable in bridge is very important because it may cause the unwanted catastrophic failure. Although the proof load were considered at the design stage, its soundness must be monitored continuously because the cable may be broken out without warning by the variable external load. The cable tension of in-use structures has been mainly measured by the resonance method and its use has been limited because of relatively large measurement uncertainty. Recently a new magnetic method was developed and its reliability is known to be good for evaluating the cable tension. In this study a system which can deliver the calibrated load to the cable was developed and the measurement reliability of developed magnetic sensor according to the change of external load was analyzed quantitatively. The effect of magnetization frequency, bias magnetic field, and temperature on the sensor output was also evaluated.