• Title/Summary/Keyword: 자가 계측

Search Result 614, Processing Time 0.032 seconds

Morphometric Characteristics of Torrent Catfish (Amblycipitidae) in Korea (퉁가리과(Amblycipitidae) 어류 계측형질 특징)

  • Park, In-Seok;Seol, Dong-Won;Kang, Eon-Jong;Kim, Chi-Hong
    • Korean Journal of Ichthyology
    • /
    • v.18 no.3
    • /
    • pp.209-215
    • /
    • 2006
  • A closely associated set of characteristics was analyzed using both classical and truss dimensions to discriminate the morphometric traits of three species of torrent catfish (Amblycipitidae) in Korea. After arcsine square root transformation, 18 measurements relative to the standard length and three measurements relative to the head length of each species of torrent catfish were compared statistically. Classical and truss dimensions of each of four morphometric traits showed higher values in the bullhead torrent catfish, Liobagrus obesus, than the Korean and south torrent catfish (L. andersoni and L. mediadiposalisa, respectively; P<0.05). Truss dimensions of three morphometric traits were higher in the bullhead and Korean torrent catfish than in the south torrent catfish (P<0.05). There were no significant differences in six morphometric traits among these Amblycipitidae. The dimensions used in this study may be useful as taxonomic indicators to discriminate species of Liobagrus in Korea.

해양플렌트를 위한 4륜구동 청소 로봇 시스템 개발

  • Kim, Min;Choi, Myoung-Hoon;Jeong, Jae-Hoon;Kim, Hyun-Jo;Kang, Min-Woo;Park, Won-Hyeon;Kim, Gwan-Hyung;Byun, Gi-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.919-920
    • /
    • 2014
  • 따개비(barnacle)는 선저부에 붙어서 번식하며 딱딱한 석회질 껍데기로 덮여있다. 이로 인하여 선박의 속도를 저하시키고 도료기능을 상실시키는 주요인이 된다. 이를 제거하기 위해 작업자가 직접 액체를 분사하고 브러쉬로 세척해야 한다는 불편함과 위험에 노출되기 때문에 선박작업용 로봇이나 기계들이 많이 개발되고 있다. 현재 연구 중이거나 개발이 완료된 것 중에는 영구자석 또는 전자석 휠을 사용하거나 공압을 이용하여 수직벽면에서 작업을 한다. 특히 공압 방식을 많이 사용하였는데 수직벽면에 로봇이 밀착될 만큼 강한 공압이 필요하게 되기 때문에 부가적인 장치가 많이 필요하다. 본 논문에서는 부가적인 장치를 최소화하고 효과적인 동작을 하기위해 전자석 방식을 선택 하였으며 간편하게 선박의 수직벽면을 작업할 수 있는 전자석 방식의 4륜 로봇을 개발하고자 한다. 선박의 수직벽면 작업용 4륜구동 로봇을 전자석을 이용하여 수직벽면에 부착할 수 있도록 설계하였으며 자력의 세기와 방향을 제어하여 로봇이 선박의 수직면에 밀착되어 자유롭게 이동이 가능하도록 개발 하고자 한다.

  • PDF

Mid-term Results of Arthroscopic Anterior Cruciate Ligament Reconstruction using Autologous Bone-Patellar tendon-Bone versus Hamstring tendon (자가 골-슬개건-골과 슬괵건을 이용한 관절경적 전방 십자 인대 재건술의 중기 추시 결과)

  • Sim, J.A.;Kwak, J.H.;Lee, B.K.
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.1
    • /
    • pp.45-49
    • /
    • 2006
  • 목적: 자가 골-슬개건-골과 슬괵건을 이용한 전방 십자 인대 재건술의 5년 중기 추시 결과를 비교 분석하고자 한다. 대상 및 방법: 전방 십자 인대 재건술을 시행한 후 5년 이상 추시 관찰이 가능한 65예를 대상으로 하였고, 골-슬개건-골이 38예, 슬괵건이 27예였다. 술 후 평가는 Lysholm 점수, 관절 운동 범위, 대퇴부 중간 부위 둘레 길이, Lachman 검사, 축 이동 검사, KT 2000 관절 계측기를 시행하였고, 술 후 합병증을 평가하였다. 결과: Lysholm 점수는 골-슬개건-골군과 슬괵건국에서 각각 평균 91점, 94.2점으로 슬괵건군이 우수하였고, 대퇴부 중간 부위 둘레 길이는 건측에 비해 각각 평균 1.7cm, 1.3cm의 차이를 보였다. 양 군간에 관절 운동 범위, Lachman 검사, 축 이동 검사 및 KT 2000 관절 계측 결과는 통계적으로 유의한 차이가 없었으나, 술 후 합병증은 과도한 보행이나 운동 후 슬관절 동통이 골-슬개건-골군에서 7예, 슬괵건 군에서 4예 관찰되었고, 전방 슬관절 동통이 골-슬개건-골군에서 4예 관찰되어, 골-슬개건-골군에서 더 많이 발생하였다. 결론: 5년 중기 추시에서 자가 슬괵건군이 우수한 슬관절 기능, 적은 합병증 등 임상적으로 우수하였으나 장기 추시가 요할 것으로 사료된다.

  • PDF

Smart meter data transmission device and power IT system using LTE and IoT technologies (LTE와 IoT 기술을 이용한 스마트미터 데이터 전송장치와 전력 IT 시스템)

  • Kang, Ki-Beom;Kim, Hong-Su;Jwa, Jeong-Woo;Kim, Ho-Chan;Kang, Min-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.117-124
    • /
    • 2017
  • A Smart Grid is a system that can efficiently use energy by exchanging real-time information in both directions between a consumer and a power supplier using ICT technology on an existing power network. DR(Demand response) is an arrangement in which electricity users can sell the electricity they save to the electricity market when the price of electricity is high or the power system is crisis. In this study, we developed a power meter data transmission device and power IT system that measure the demand information in real-time using a smart meter and transmit it to a cloud server. The power meter data transmission device developed in this study uses alight sensor connected to a Raspberry Pi 3 to measure the number of blinking lamps on the KEPCO meter per unit of power, in order to provide reliable data without any measurement errors with respect to the KEPCO power data. The power measurement data transmission device uses the standard communication protocol, OpenADR 2.0b. The measured data is transmitted to the power IT system, which consists of the VEN, VTN, and calculation program, via the LTE WiFi communication network and stored in its MySQL DB. The developed power measurement data transmission device issues a power supply instruction and performs a peak reduction DR when a power system crisis occurs. The developed power meter data transmission device has the advantage of allowing the user to adjust it every 1 minute, where as the existing smart metering time is fixed at once every 15 minutes.

A STUDY ON ACCURACY OF MAXILLARY REPOSITIONING BY EXTERNAL MEASURING TECHIQUE (외부계측법에 의한 상악골 이동의 위치적 정확도에 대한 평가 연구)

  • Park, Hyung-Sik;Cha, In-Ho;Park, Hyung-Rae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.1
    • /
    • pp.44-52
    • /
    • 1991
  • Internal measurement technique has been commonly and classically used to guide down-fractured maxilla by Le Fort I osteotomy into its new position during intraoperative procedure for correlating preoperative model works with surgery. However, It has been challenged now by several authors due to some problems as its inaccuracy in three-dimensional changes at surgery, difficulty to measure during surgery and impossibility of rechecking at the end of surgery etc. The purpose of this study was to evaluate the accuracy of maxillary movement by external measuring technique and to determine its accuracy between the prediction tracing and a new maxillary position. The results indicate that the external measuring technique was predictable in the vertical, horizontal and transverse change of the maxilla as its prediction, however, it has a tendency to shift the maxilla more anterior and inferior in overall direction than prediction. Post-operative canting difference were mimic, however Ehange of the maxillary dental midline was large and had a right-shifting tendency.1 The precise methods to keep maxillary dental midline as same as prediction and the avoidance of uneven force applied to the mandible for autorotation should be necessary during surgery in use of external measurement technique.

  • PDF

THE LATERAL CEPHALOMETRIC STUDY OF THE GROWING CHILDREN WITH CLASS III MALOCCLUSION BY MCNAMARA ANALYSIS (McNamara분석법에 의한 III급 부정교합 아동의 두부방사선 계측학적 연구)

  • Yang, Ku-Ho;Kim, Ji-Young;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.412-420
    • /
    • 2001
  • In the growing children with normal occlusion and class III malocclusion who need the early treatment to be helped to diagnose and to set up treatment plan by calculating the mean values of the lateral cephalometric measurements, cephalometric measurements by McNamara alalysis were achieved and compared on both the 84 elementary school children with normal occlusion and 83 class III malocclusion children at the age of 7 to 9 in Kwangju city and the results were as follows: 1. On the boys group, between normal occlusion and class III malocclusion, Effective maxillary length, Maxillomandibular differential, Facial axis, Nasion perpendicualr to pogonion, Point A perp to Mx 1, and A-Pog line to Mn 1 showed significant differences(p<0.05). 2. On the girls group, between normal occlusion and class III malocclusion significant differences were shown in Effective Maxillary length, Maxillomandibular differential, Mandibular plan angle, Nasion perpendicualr to Point A, Point A perp to Mx 1, A-Pog line to Mn 1(p<0.01). 3. There were no significant differences between normal occlusion and class III malocclusion of boys group but significant differences between them of girls group in Effective mandibular length(P<0.01). On the boys and girls group, Effective maxilla length of class III malocclusion was shorter than that of normal occlusion. 4. There were no significant differences between normal occlusion and class III malocclusion both in boys and girls at Anterior lower facial height. 5. There were significant differences between boys and girls both in class III malocclusion and normal occlusion at Anterior lower facial height and Mandibular plane angle(p<0.01).

  • PDF

Analysis of a Pollutant Flow Tracer Test in River using Radioactive Isotope (하천에서 추적자를 이용한 오염물질 거동분석)

  • Kim, Ki-Chul;Lee, Jong-Seok
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.1
    • /
    • pp.400-406
    • /
    • 2009
  • In this study, in order to find the movement of polluted substance that is flown into the river and the characteristics of dispersion, the experiment that used the RI (Radioactive Isotope) tracer in the river was undertaken, and by using the experiment result, the figure modelling was undertaken to analyze the general type of pollutant dispersion. In addition, in order to calculate more accurate dispersion range and moving time, the experiment was done in about 2km from the measuring points of Namdae Stream around the Yongdam Dam of the upper Geum River to the lower stream. In order to find out the flow of river and dispersion of polluted substance, RMA (Resource Modeling Associates)-2 and RMA-4 program are used in study. The site experiment using the RI was implemented for the experiment in the applied area and the same area, and the distance between each zone was set for 1km with the slight difference for site situation and measured the density date of one second distance through the NaI apparatus to measure the density data of one second interval. On the basis of this measured data, it is compared and analyzed with the result of figure copy of the models to make the comparison and analysis of density distribution following the change in expansion coefficient that makes great influence on expansion range and dispersion in natural rivers.

The Study for Establishing the Criteria of Measurement Items in the Monitoring System for the Steel-Box Girder Bridge by FEM Analysis (구조해석에 의한 강상자형교 상시계측시스템 계측항목별 관리기준치 설정 연구)

  • Joo, Bong-Chul;Park, Ki-Tae;You, Young-Jun;Lee, Chin-Hyung;Hwang, Yoon-Koog
    • Journal of Korean Society of societal Security
    • /
    • v.2 no.4
    • /
    • pp.35-41
    • /
    • 2009
  • If any bridge has the monitoring system, the bridge manager can check the history of bridge behavior and the progress of the damage more exactly. When the unexpected event (ex: earthquake and flood) happens, the manager can check the safety condition of the bridge and make the pertinent action for bridge management which is reduction of vehicle speed or traffic control through the system. Additionary the manager can make the well-timed repair or reinforcement through the system, so he can save the management cost or the life cycle cost. This study presents the method of setting the criteria by FEM analysis in bridge monitoring system, and the standard progress for setting the criteria about measurement items of monitoring system for the steel box type bridge.

  • PDF

Application of the Detection of External Contamination on Radiation Workers for Bed Type Whole Body Counting Using Monte Carlo Method (몬테카를로 방법을 적용한 bed type 전신계측기의 방사선작업종사자 외부오염 검출 응용)

  • Kim, Jeong-In;Lee, Byoung-Il
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.242-245
    • /
    • 2013
  • Monte Carlo method was applied to discriminate the external contamination on radiation workers in nuclear power plants for internal dose assessment generally used with a bed type scanning detector whole body counter. Korean voxel model with internal contamination was used to estimate the detection patterns of whole body scanning. Also, the BOMAB model with various external contamination was assumed to compare with detection of radionuclides inside the human body. From the comparison of detection efficiency between front and back side up, external contamination was easily distinguished.

Distance measurement systems implemented for ASV (ASV를 위한 차량탑재용 거리계측기술)

  • 장경영
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.18 no.3
    • /
    • pp.45-54
    • /
    • 1996
  • 최근 자동차의 안전성을 한층 강조하는 ASV 개념의 도입이 보편화되면서 이를 구현하기 위한 여러가지 기능들이 고안되어 지고 있는데, 그 중에서도 추돌경보 및 회피기능, 야간보행자 검지기능, 후측방 장애물검지 기능, 차간거리 일정유지 제어기능 등에 있어서 공통적으로 주행중 거리계측이 필요하다. 본고에서는 ASV기술에서 필요하고 또한 중요한 핵심기술인 차량탑재용 거리계측기술에 대하여 현재 실용화되어 있거나 실용가능성이 있는 기술을 수단과 방식으로 나누어 각각의 원리와 특징에 대해 소개하였다. 수단으로서는 초음파, 레이저, 밀리파를 제시하였으며, 방식으로는 펄스시간차방식, 진폭변조 및 위상복조방식, 주파수변조방식을 소개하였다. 또한 비젼은 이들과는 계측원리와 신호처리가 매우 상이하고 본특집에서 별도로 상세히 소개될 것이기 때문에 간략히 소개하였다.

  • PDF