• Title/Summary/Keyword: 잉여저항

Search Result 22, Processing Time 0.021 seconds

Prediction of Residual Resistance Coefficient of Low-speed Full Ships using Hull Form Variables and Model Test Results (선형변수 및 모형시험결과 데이터베이스를 활용한 저속비대선의 잉여저항계수 추정)

  • Kim, Yoo-Chul;Kim, Myung-Soo;Yang, Kyung-Kyu;Lee, Young-Yeon;Yim, Geun-Tae;Kim, Jin;Hwang, Seung-Hyun;Kim, JungJoong;Kim, Kwang-Soo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.5
    • /
    • pp.447-456
    • /
    • 2019
  • In the early stage of ship design, the rapid prediction of resistance of hull forms is required. Although there are more accurate prediction methods such as model test and CFD analysis, statistical methods are still widely used because of their cost-effectiveness and quickness in producing the results. This study suggests the prediction formula for the residual resistance coefficient (Cr) of the low-speed full ships. The formula was derived from the statistical analysis of model test results in KRISO database. In order to improve prediction accuracy, the local variables of hull forms are defined and used for the regression process. The regression formula for these variables using only principal dimensions of hull forms are also provided.

Self-Diagnosis of Damage in Carbon Fiber Reinforced Composites Using Electrical Residual Resistance Measurement (잉여 전기 저항 측정을 이용한 탄소 섬유 강화 복합재의 파손 측정)

  • Kang, Ji-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.323-330
    • /
    • 2009
  • The objective of this research was to develop a practical integrated approach using extracted features from electrical resistance measurements and coupled electromechanical models of damage, for in-situ damage detection and sensing in carbon fiber reinforced plastic(CFRP) composites. To achieve this objective, we introduced specific known damage (in terms of type, size, and location) into CFRP laminates and established quantitative relationships with the electrical resistance measurements. For processing of numerous measurement data, an autonomous data acquisition system was devised. We also established a specimen preparation procedure and a method for electrode setup. Coupon and panel CFRP laminate specimens with several known damage were tested. Coupon specimens with various sizes of artificial delaminations obtained by inserting Teflon film were manufactured and the resistance was measured. The measurement results showed that increase of delamination size led to increase of resistance implying that it is possible to sense the existence and size of delamination. A quasi-isotropic panel was manufactured and electrical resistance was measured. Then three different sizes of holes were drilled at a chosen location. The panel was prepared using the established procedures with six electrode connections on each side making a total of twenty-four electrodes. Vertical, horizontal, and diagonal pairs of electrodes were chosen and the resistance was measured. The measurement results showed the possibility of the established measurement system for an in-situ damage detection method for CFRP composite structures.

A Study on the Method of Giving Hysteresis Characteristics to the Digital input port of Microprocessors (마이크로프로세서 디지털 입력포트에 대한 히스테리시스 특성 부여방법에 관한 연구)

  • Lee, Hyun-Chang
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.2
    • /
    • pp.56-63
    • /
    • 2011
  • This paper presents the method of giving hysteresis characteristics to the digital input port of microprocessors or micro-controllers and it's design procedures. And this paper shows the example of circuit design and the effect of this method by experiments. Presented method has advantages : By the additional one port and two resistors, input port can have hysteresis characteristics and hysteresis band is larger than TTL, CMOS schmitt trigger gates.

The nitrogen doping effect on the Cr-C:H films deposited by the hybrid deposition proces (하아브리드 공정을 통한 Cr-C:H 박막의 질소 도핑에 관한 연구)

  • Jo, Yong-Gi;Kim, Gang-Sam;Jeong, Dong-Geun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.05a
    • /
    • pp.192-192
    • /
    • 2012
  • 플라즈마 CVD와 아크방전법을 혼합한 하이브리드 공정을 통하여 알곤과 메탄 그리고 질소를 인입하여 Cr을 타겟으로한 아크방전과 기판에 전극을 인가하는 방식의 플라즈마 CVD공정을 복합화하여 금속이 함유된 Cr-C:H 박막을 합성하고, 공정에 질소를 인입하여 박막에 질소를 도핑하여 부내식성과 전기적 전도성에 관한 고찰을 하였다. 내부식성은 동전위분극시험에서 $1{\mu}A/cm^2$을 보였고, 전기저항은 $1m{\Omega}-cm$ 이하로 측정되어 내식성과 전기전도성을 동시에 갖는 박막을 합성할 수 있었다. 내식성과 전기전도성에 대한 원인규명을 위하여 박막의 구조분석을 XPS, XRD, Raman 분석을 통하여 실시하였다. 흑연화 탄소(Graphitic carbon)와 금속콤포짓(Metal composite)은 내식성에 영향을 주었으며, 전도성물질의 percolation효과와 질소와 탄소의 단일 결합과정에서 생성되는 잉여전자에 의한 단일 결합(C-N) 분율이 전기전도성에 영향을 주었다.

  • PDF

Reaction Gas Composition Dependence on the Properties of SnO2 Films on PET Substrate by ECR-MOCVD (반응가스조성이 PET기판위에 ECR 화학증착법에 의해 제조된 SnO2 박막특성에 미치는 영향)

  • Kim, Yun-Seok;Lee, Joong-Kee
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.3
    • /
    • pp.139-145
    • /
    • 2005
  • [ $SnO_x$ ] films on the flexible substrate of PET film were prepared at ambient temperature under a $(CH_3)_4Sn(TMT: tetra-methyl tin)-H_2-O_2$ atmosphere in order to obtain transparent conductive polymer by using ECR-MOCVD(Electro Cyclotron Resonance Metal Organic Chemical Yfpor Deposition) system. The prepared $SnO_x$ thin films show generally over $90\%$ of optical transmittance at wavelength range of 380-780nm and about $1\times10^{-2\~3}ohm{\cdot}cm$ of electrical resistivity. In the present study, effects of $O_2/TMT\;and\;H_2/TMT$ mole ratio on the properties of $SnO_x$ films are investigated and the other process parameters such as microwave power, magnetic current power, substrate distance and working pressure are fixed. Based on our experimental results, the $SnO_x$ film composition ratio of Sn and O directly influences on the electrical and optical properties of the films prepared. The $SnO_x$ film with low electric resistivity and high transmittance could be obtained by controlling the process parameters such as $O_2/TMT\;and\;H_2/TMT$ mole ratio, which play an important role to change the composition ratio between Sn and O. An increase of $O_2/TMT$ mole ratio brought on the increases 0 content in the $SnO_x$ film. On the other hand, an increase of $H_2/TMT$ mole ratio lead to decreases the oxygen content in the film. The optimized composition ratio of oxygen : tin Is determined as 2.4: 1 at $O_2/TMT$ of 80 and $H_2/TMT$ of 40 mole ratio, respectively.

The Study on the Separation Characteristics of ion with ion Exchange Membrane - I.The Characteristics of ion Exchange Membrane with the Separator of All-Vanadium Redox Flow Battery - (이온교환막을 이용한 이온의 분리특성에 관한 연구 - I. 전바나듐계 레독스-흐름 전지의 격막용 이온 교환막의 특성 -)

  • Kang, An-Soo
    • Applied Chemistry for Engineering
    • /
    • v.4 no.2
    • /
    • pp.393-402
    • /
    • 1993
  • Redox flow secondary battery have been studied actively as one of the most promising electrochemical energy storage devices for a wide range of applications, such as electric vehicles, photovoltaic arrays, and excess power generated by electric power plants. In all-vanadium redox flow battery using solution of vanadium-sulfuric acid as a active material, the difficulty in developing an efficient ion selective membrane can still be identified. The asymmetric cation exchange membrane(M-30) as a separator of all-vanadium redox flow battery which were obtained by the reaction of chlorosulfonation for 30 minutes under the irradiation of UV, showed its superiority in the transport number of 0.94 and electrical resistivity of $0.5{\Omega}{\cdot}cm^2$. The base membrane were prepared by lamination a low density polyethlene film of $10{\mu}m$ thickness on polyolefin membrane(HIPORE 120). The electrical resistivity of M-30 membrane in real solution of vanadium-sulfuric acid was $3.79{\Omega}{\cdot}cm^2$ and it was similar to that of Nafion 117 membrane. Also the cell resistivity was $6.6{\Omega}{\cdot}cm^2$and lower than that of Nafion 117. In considertion of electrochemical properties and costs of membranes, M-30 membrane was better than that of Nafion 117 and CMV of Asahi glass Co. as a separator of all-vanadium redox flow battery.

  • PDF

Characteristics of ITO with surface treatment by N2, O2, Ar Plasma and UV (질소, 산소, 아르곤 플라즈마와 자외선에 의하여 표면 처리한 ITO의 특성)

  • Bae, Gyeong-Tae;Jeong, Seon-Yeong;Gang, Seong-Ho;Kim, Hyeon-Gi;Kim, Byeong-Jin;Ju, Seong-Hu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.90-90
    • /
    • 2018
  • 디스플레이는 다수의 가로 전극과 세로 전극으로 구성되고, 전극에 신호를 주어 동작하도록 하는 원리이다. 이 디스플레이에는 전기가 통하고 투명한 전극이 필수적으로 사용되고 있고, 대표적인 투명 전극으로 ITO (Indium Tin Oxide)가 있다. ITO 박막은 $In_2O_3$에 Sn을 첨가하여 $Sn^{4+}$ 이온이 $In^{3+}$ 이온을 치환하고 이 과정에서 잉여 전자가 전기전도에 기여하는 구조이다. ITO 박막은 표면 처리 방법에 따라 표면 상태가 크게 변화한다. 플라즈마를 이용한 표면 처리는 환경오염이 적으며 강도, 탄성률 등과 같은 재료의 기계적 특성을 변화시키지 않으면서 표면 특성만을 변화시킬 수 있는 방법으로 알려져 있다[1]. UV (Ultraviolet)를 조사한 표면처리는 ITO 표면의 탄소를 제거하고, 표면 쌍극자를 형성하며, 표면의 조성을 변화시킬 수 있으며, 페르미 에너지 준위를 이동시킬 수 있어 ITO의 일함수를 증가시킬 수 있다[2]. ITO에 대한 다양한 연구가 수행되었음에도 불구하고 보다 다양한 관점에서의 연구가 지속될 필요가 있다. 따라서 본 연구에서는 다양한 조건으로 표면 처리한 ITO 표면의 일함수, 면저항, 표면 형상, 평탄도, 접촉각 등에 대해 알아보고자 한다. 세정한 ITO, 세정 후 UV 처리한 ITO (UV 처리 시간 2분, 4분 6분, 8분), 세정 후 $N_2$, $O_2$, Ar의 공정 가스를 사용하여 Plasma 처리한 ITO로 표면 처리 조건을 변화하였다. 표면 처리한 ITO의 특성은 Kelvin Probe를 이용한 일함수, 물방울 형상의 각도를 측정한 접촉각, AFM (Atomic Force Microscope)을 이용한 평탄도, 가시광선 (380~780 nm) 파장에 대한 투과도와 면저항을 측정하였다. 접촉각은 세정한 ITO의 경우 $45.5^{\circ}$에서 세정 후 UV를 조사한 ITO의 경우 UV 8분 조사 시 $27.86^{\circ}$로 감소하였고, $N_2$, $O_2$, Ar 가스를 사용하여 Plasma 처리한 ITO는 모두 $10^{\circ}$ 미만을 나타내었다. 플라즈마 처리에 의하여 접촉각이 현저하게 개선되었다. ITO의 면저항은 표면 처리 조건에 따라 $9.620{\sim}9.903{\Omega}/{\square}$로 그 차이가 매우 적어 표면처리에 의하여 면저항의 변화는 없는 것으로 판단된다. 가시광선 영역에서의 투과도는 공정 조건에 따라 87.59 ~ 89.39%로 그 차이가 적어 표면처리에 의한 변화를 나타내지는 않은 것으로 판단된다. 표면 처리 조건에 따른 평탄도 $R_{rms}$는 세정한 ITO의 경우 4.501 nm로부터 UV 2, 4, 6, 8분 처리한 경우 2.797, 2.659, 2.538, 2.584 nm로 평탄도가 개선되었다. $N_2$, $O_2$, Ar 가스를 사용하여 플라즈마 처리한 ITO의 경우 평탄도 $R_{rms}$는 2.49, 4.715, 4.176 nm로 사용한 가스의 종류에 따라 다른 경향을 나타내었다. 표면 처리 조건에 따른 평탄도 Ra는 세정한 ITO의 경우 3.521 nm로부터 UV 2, 4, 6, 8분 처리한 경우 1.858, 1.967, 1.896, 1.942 nm를, $N_2$, $O_2$, Ar 가스를 사용하여 플라즈마 처리한 ITO의 경우는 1.744, 3.206, 3.251 nm로 평탄도 $R_{rms}$와 유사한 경향을 나타내었다.

  • PDF

Assessment of Immune Quality and Pathogen Contamination of Colostrums Collected from Colostrum Banks in Korea (초유은행에서 수거한 초유의 병원체 오염과 면역수준의 평가)

  • Kim, Won-Il;Park, Sang-Yul;Kim, Sang-Jin;Cho, Yong-Il;Hur, Tai-Young;Kim, Nam-Soo
    • Journal of Veterinary Clinics
    • /
    • v.30 no.4
    • /
    • pp.223-229
    • /
    • 2013
  • Because colostrum is considered to be the sole source of passively acquired maternal antibodies for calves, newborn calves must consume colostrum to gain disease resistance during their early years of life. Storage of surplus colostrum from dairy cows right after calving and feeding newborn calves in deficiency of colostrum to assure adequate uptake of IgG for protection of the calf has been a common practice in the bovine production. In the current study, 35 colostrums were randomly collected from 3 colostrum banks located in different regions of Korea and monitored for general bacterial contamination and major bovine pathogens. Immunoglobulin concentrations and BVDV-specific antibodies were also determined to evaluate the immune quality of the colostrums. Moderate to severe bacterial contamination (up to 72,000,000 CFU/ml) was observed in most of the colostrums collected from colostrum banks. General immune quality of the colostrums was under the satisfactory level since most of the colostrums contained less than 50 g/L of IgG, which is the minimum concentration for good quality colostrums. Therefore, colostrum for colostrum bank should be collected at the first 2-3 post-partum milkings according to proper harvesting and handling procedures to guarantee the safety and quality of colostrum. In addition, it was recommended that colostrum should be heat-treated before frozen and stored in the bank because pasteurization at $63^{\circ}C$ for 30 min was very effective reducing the risk of disease transmission without causing significant degradation of immunoglobulins.

Effect of Nb, V and Cr on the High Temperature Oxidation of Ti-(42, 44)% Al Alloys (Ti-(42, 44)%Al 합금의 고온내산화성에 미치는 Nb, V 및 Cr의 영향)

  • Lee, Yeong-Chan;Kim, Mi-Hyeon;Kim, Seong-Hun;Lee, Won-Uk;Baek, Jong-Hyeon;Lee, Dong-Bok
    • Korean Journal of Materials Research
    • /
    • v.9 no.10
    • /
    • pp.1025-1031
    • /
    • 1999
  • Alloys of TiAl with six different compositions. i. e., Ti-(42, 44)Al-2Nb-4V. Ti-(42, 44)Al-4Nb-2V and Ti -(42, 44)Al-4Nb-2Cr, were manufactured by arc-melting. and their oxidation behavior was studied. Both isothermal and cyclic oxidation tests were performed at 700, 800 and $900^{\circ}C$ in air for 50hr. The oxidation resistance increased in the order of Ti-(42, 44)Al-2Nb-4V, Ti-(42, 44)Al-4Nb-ZV and Ti-(42, 44)Al-4Nb-2Cr. It was found that V was a deleterious element, while Cr was a beneficial element in terms of oxidation resistance. During oxidation, a simultaneous interdiffusion was observed. All the constituent elements in the base alloys diffused outward. whereas oxygen from the atmosphere diffused inward, to form triple oxide layers composed of an outermost $\textrm{TiO}_2$ layer. upper ($\textrm{TiO}_2+\textrm{Al}_2\textrm{O}_3$) mixed layer, and lower $\textrm{TiO}_2$-rich layer.

  • PDF

Estimation of Response Modification Factor and Nonlinear Displacement for Moment Resisting Reinforced Concrete Frames (철근콘크리트 연성 모멘트골조에 대한 반응수정계수와 비선형 변위량의 평가)

  • 김길환;전대한;이상호
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.29-37
    • /
    • 2002
  • The purpose of this study is to provide a fundamental data of earthquake resistant design through the estimation of the response modification factor and nonlinear displacement for moment resisting reinforced concrete frames by linear and nonlinear static analysis. The analysis models are designed in accordance with AIK code and then, estimated the response modification factor and nonlinear displacement of the buildings. The parameters such as story numbers(10, 20, 30), plan ratios(1:1, 1:2) and analysis types(2D, 3D) of building structure are chosen for use in this study. After comparing the results of linear and nonlinear static analysis, the response modification factor is obtained as the product of four factors: ductility factor, strength factor, damping factor and redundancy factor. The response modification factor are close to 3.5 in case of 2 span, 4.3 in case of 3 span and 5.0 in case 4 or more span models regardless number of stories and plan ratios. The nonlinear displacement is evaluated from the ratio of story drift angle(nonlinear drift/linear drift). The ratio of story drift angle increases as story numbers increase and the value varies from 5.85 to 9.34.