• Title/Summary/Keyword: 입자 분리기

Search Result 182, Processing Time 0.027 seconds

Effect of internal pressure variation on the ceramic particle separation characteristics : computer simulation (분리기 내부 압력 변화에 따른 세라믹 입자 분리 거동 전산모사)

  • 우효상;심광보;정용재
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.6
    • /
    • pp.304-308
    • /
    • 2003
  • By controlling the internal pressure in the cyclone separator, we investigated the separation charateristics of $Al_2O_3$, $Fe_2O_3$ particles with the internal pressure variation. 3-dimensional Langrangian approach was applied for the analysis of the particles separation, and then the minimum cut diameter of the separated particles and the separation rate were calculated through tracking the particle trajectories. The density of the argon gas for transporting particles was decreased corresponding the pressure decrease, consequently, caused the internal pressure drop in the cyclone separator. For that reason the finer particles were separated as the pressure was changed from an atmospheric pressure to an low pressure. Specifically, at 50 torr pressure, $Al_2O_3$ particles of the size of about 4 $\mu\textrm{m}$ and $Fe_2O_3$particles of about 3 $\mu\textrm{m}$ could be separated.

Development of Solid Separator for Selective Solid Circulation in Two-interconnected Fluidized Beds System (2탑 유동층 시스템에서 선택적 고체순환을 위한 고체분리기 개발)

  • Ryu, Ho-Jung;Park, Young Cheol;Lee, Seung-Yong;Kim, Hong-Ki
    • Korean Chemical Engineering Research
    • /
    • v.47 no.2
    • /
    • pp.195-202
    • /
    • 2009
  • As a basic research of developing two-interconnected fluidized beds system for selective solid circulation, a solid separator was developed to separate fine and coarse particles by means of particle size difference with particle size separation system equipped with metal screen. The effects of gas velocity, height of solid separator, and separation area on the solid separation rate were investigated as well. The solid separation rate increased as the gas velocity, height of solid separator, and separation area increased. As the gas velocity and height of the solid separator increased, the variation of the solid separation rate was consistent with that of bubble size. Consequently, coarse($212{\sim}300{\mu}m$) and fine($63{\sim}106{\mu}m$) particles were separated using the solid separator and the solid separation rate was ranged from 4.4 to 127 g/min. We also proposed two interconnenced fluidized beds system for sorption enhanced water-gas shift process equipped with the developed solid separator.

Geant4를 이용한 STEIN 검출기의 입자 분리 검출 모의실험 예비 결과 분석

  • Park, Seong-Ha;Kim, Yong-Ho;U, Ju;Seon, Jong-Ho;Jin, Ho;Lee, Dong-Hun;Lin, Robert P.;Immel, Thomas
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.212.2-212.2
    • /
    • 2012
  • 지구 자기권에 존재하는 플라즈마 입자의 다중관측을 목적으로 개발된 초소형 탑재체 STEIN (SupraThermal Electron, Ion, Neutral) 은 경희대학교와 UC Berkeley가 공동으로 개발 중인 3대의 초소형 과학위성 TRIO-CINEMA (TRiplet Ionosphere Observatory - Cubesat for Ion, Neutral, Electron and MAgnetic fields) 에 탑재될 입자 검출기이다. 32개의 픽셀로 이루어진 STEIN 검출기는 2~300 keV의 전자, 4~300 keV의 이온과 중성입자(Energetic Neutral Atom: ENA) 를 분리 계측할 목적으로 설계되었으며, 하전입자가 정전장 편향기를 통과하여 서로 다른 검출기 픽셀에 도달함으로써 전자와 이온, 중성입자를 분리하여 계측할 수 있도록 하였다. 한편, STEIN 구조물에서 발생한 2차 입자의 검출을 방지하기 위해 정전 편향기 사이에 차단날(blade)을 설계하였다. 본 연구에서는 STEIN 모의실험 예비 결과로써 전기장에 크기 및 차단날에 의한 하전입자의 궤적과 이에 따른 분리 계측 성능을 알아보고자 Geant4 (GEometry ANd Tracking)를 사용하여 검출기 픽셀에 입사하는 전자의 초기 위치를 분석하였다. 전자의 입사 위치는 검출기로부터 5 cm 전방에서 6 mm * 20 mm 범위 내에서 무작위로 생성하여 검출기의 방향으로 수직 입사하였다. 분석 결과 전자들은 전기장의 방향에 따라 편향되는 결과를 보였으며, 저에너지 전자는 강한 전기장의 영향으로 차단날에 의해 차폐되어 검출되지 않았다. 따라서 전기장의 크기와 차단날에 따른 입자 분리 검출이 가능함을 본 모의실험을 통해 확인하였으며, STEIN 운용 시 입자 분리 검출 및 결과 분석 기반으로 본 연구 결과를 사용될 수 있을 것으로 기대된다.

  • PDF

Numerical investigation of ceramic particle movement for injected gas flow rate in cyclone separator system (사이클론 분리기 시스템 내에서의 가스 주입 유속에 따른 세라믹 입자 거동 전산모사)

  • 우효상;심광보;정용재
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.3
    • /
    • pp.145-151
    • /
    • 2003
  • Using computational fluid dynamics (CFD) method, we investigated three-dimensional fluid flow field and particle movement with respect to the injected gas flow rate variation in typical cyclone separator system. The results of numerical investigation were deduced by coupling the analysis of fluid flow field with Wavier-stokes equation and the tracking of the particle trajectory with Langrangian approach. It was shown that the increasing of injected gas flow rate resulted in the increasing of pressure loss in the separator. This change of inner pressure had an effect on an aspect of the fluid flow in the separator. Particle movement was determined by fluid flow in the separator and was fully depended on a diameter of particles under the fixed flow rate. Increasing of injected gas flow rate was led to an increasing of the trace of particle, so the particles moved to the lower part of the separator. For this reason, the minimum diameters of the particles were decreased and increased the separation rate under the fixed particle diameter. In conclusion, the changes of injected gas flow rate have an important factor to the fluctuation of the fluid flow field and particle trajectory in the separator.

Effects of Operating Variables on Solid Separation Rate in Two-interconnected Fluidized Beds System for Selective Solid Circulation (선택적 고체순환을 위한 2탑 유동층 시스템에서 고체분리속도에 미치는 조업변수들의 영향)

  • Ryu, Ho-Jung;Jin, Gyoung-Tae;Bae, Dal-Hee;Kim, Hong-Ki
    • Korean Chemical Engineering Research
    • /
    • v.47 no.3
    • /
    • pp.355-361
    • /
    • 2009
  • Effects of operating variables on solid separation rate in two-interconnected fluidized beds system for selective solid circulation have been investigated. Coarse(212~300 or $425{\sim}600{\mu}m$) and fine($63{\sim}106{\mu}m$) particles were separated using the solid separator and the solid separation rate was ranged from 66 to 987 g/min. The solid separation rate increased as the gas velocity through the solid injection nozzle, solid height, diameter of solid injection nozzle, particle size of coarse particles, aperture of the solid separator, and weight fraction of fines in the solid mixture increased. However, the effect of the fluidization velocity was negligible.

Particle path and performance evaluation of differential mobility analyzer (Differential Mobility Analyzer(DMA)내의 입자운동 및 특성 분석)

  • An, Gang-Ho;Kim, Nam-Hyo;Lee, Jong-Ho;Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.6
    • /
    • pp.2005-2013
    • /
    • 1996
  • Particle paths and flow fields in a prototype differential mobility analyzer (DMA) were numerically analyzed solving Navier-Stokes equation, electric field equation and particle motion considering viscous drag force, Coulomb force and polarization force. Analytically predicted particle diameters for the prototype DMA are in good agreement with the measured particle diameters within $\pm$1%. And the analytically predicted particle diameters are also in good agreement with numerical results for the prototype DMA.

Smoothed Particle Hydro-dynamic Analysis of Improvement in Sludge Conveyance Efficiency of Screw Decanter Centrifuge (입자 완화 유체 동역학 해석 기법을 이용한 스크류 디켄터형 원심분리기의 슬러지 이송 효율 향상 분석)

  • Park, Dae Woong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.285-291
    • /
    • 2015
  • A centrifuge works on the principle that particles with different densities will separate at a rate proportional to the centrifugal force during high-speed rotation. Dense particles are quickly precipitated, and particles with relatively smaller densities are precipitated more slowly. A decanter-type centrifuge is used to remove, concentrate, and dehydrate sludge in a water treatment process. This is a core technology for measuring the sludge conveyance efficiency improvement. In this study, a smoothed particle hydro-dynamic analysis was performed for a decanter centrifuge used to convey sludge to evaluate the efficiency improvement. This analysis was applied to both the original centrifugal model and the design change model, which was a ball-plate rail model, to evaluate the sludge transfer efficiency.

Separation of Magnetic/non-Magnetic Particles by an Electromagnetic Fluidized Bed (전자석 유동층에 의한 자성/비자성 입자의 분리)

  • 김용하;서인국
    • Resources Recycling
    • /
    • v.6 no.1
    • /
    • pp.17-22
    • /
    • 1997
  • An electromagnetic fluidized bed was proposed for the continuous separation of magnetic particles from the fine a admixtures with nonHmagnetic particles. The effects of operating variables on the magnetic fraction in the separated p particles were examined, including superficial gas velocity, mixing fraction of magnetic particles (= 100-mixing fraction of n non-magnetic particles) in the admixture, and electric current supplied to the electwmagnet. It was found that the s separation was possible when a magnetic force formed by the electromagnets works on the magnetic particles over the hydrodynamic force caused by a gas stream for fluidizing the fine admixture.

  • PDF

An Application of Electrical Resistance Method for Monitoring of Rotating Cylindrical Separator (원통형 회전 분리기를 감시하기 위한 전기저항법의 이용)

  • Lee, Bo-An;Kim, Sin
    • Journal of Energy Engineering
    • /
    • v.20 no.1
    • /
    • pp.21-25
    • /
    • 2011
  • In order to monitor a rotating cylindrical separator for radioactive waste, an electrical resistance method is proposed and its mathematical model is investigated. In a rotating radioactive waste separator, the electrical resistance between a pair of electrodes mounted on the inner wall of the vessel is related to the thickness of annular region of insoluble particle formed around the periphery and the concentration of the insoluble particle in that region. This work presents an analytical relationship among the aforementioned parameters based on a two-dimensional solution to the electrical potential equation and an empirical conductivity-concentration relation. Also, the feasibility of electrical resistance method for monitoring rotating cylindrical separators is discussed.

Modeling of Waste Tire Gasification in an Internally Circulating Fluidized Bed (내부순환유동층 반응기에서의 폐타이어 가스화 모델링)

  • 이승엽;김용전;김상돈
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.05a
    • /
    • pp.75-79
    • /
    • 1999
  • 순환유동층은 주탑에서 비말 동반된 입자를 cyclone과 같은 입자 포집장치에서 회수하여 다시 주탑으로 재 주입함으로써 입자의 순환이 일어나는 외부 순환계와 종래의 유동층내에 원형관(Draft tube)이나 평판을 설치하여 두개의 층으로 분리한 후 가스 분산판 위의 간격을 통해 입자들을 두 구역 사이로 강제 순환시키는 내부순환계로 분류할 수 있다. 드래프트 관을 갖는 내부순환유동층 반응기는 기체와 고체의 적절한 접촉을 통해 반응이 이루어지는 반응기 형태이다.(중략)

  • PDF