• Title/Summary/Keyword: 입자제거 효율

Search Result 368, Processing Time 0.031 seconds

Adsorption and Removal Mechanism of Dissolved Inorganic Nutrients in Seawater by Yellow Loess (황토살포에 의한 해수중 영양염류의 흡착제거기구)

  • Kim Pyoung Joong;Heo Seung;Yun Seong Jong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.2
    • /
    • pp.146-154
    • /
    • 2002
  • To assess the adsorption and removal mechanism of dissolved inorganic nutrients in seawater by scattering yellow loess, a laboratory experiment was conducted for the change of nutrient concentration in seawater during the course of time depending on particle size and scattered concentration of the yellow loess. Twenty four hours after the addition of yellow loess in the size range of 0 $\mu$m to 500 $\mu$m in seawater, the removal rate of dissolved inorganic phosphorus (DIP) was increased with increasing amount of yellow loess. There was little difference among the removal rates depending on the size of yellow loess. On average, $26\%$ of dissolved inorganic silicate was reduced for the same period. No greate difference among the removal rate depending on both size and amount of yellow loess was found. Our results suggested that the removal mechanism of DU seemed to be associated with mostly the chemical bond with iron. More than $99\%$ of initial DU concentration was likely to be removed by this mechanism. In the case of inorganic dissolved silicate, the removal mechanism was likely to be attributed to a cation exchange between the yellow loess and seawater.

The Analysis of Coagulation Effect in the Water Treatment Plant by Input of Micro-Particles having Different Specific Gravity (비중이 다른 미세입자의 투입에 따른 정수장의 응집 효과 분석)

  • Kwon, Young-Bin;Choi, Gye-Woon;Lee, Joo-Kyoung;Park, Hyo-Seon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.673-677
    • /
    • 2009
  • 현재 상수시설의 경우 갈수록 악화되는 수질과 정수장의 유지관리 인원 상주의 어려움, 기존의 응집, 침전, 여과 정수처리 시스템의 처리성능 증대에 따른 한계성에 직면한 상황이다. 안정적으로 수질의 개선을 통한 장치의 컴팩트화, 유지관리가 편리한 고도정수 수질기준에 만족하는 정수처리 시스템이 필요하다. 본 연구에서는 기존의 정수처리 시설인 혼화지에 응집제와 함께 다양한 비중을 가지고 있는 모래입자를 투입하여 응집제와 모래의 결합에 따른 탁도 제거효율과 슬러지의 양을 비교하였으며, 침전지내에 정류벽을 설치하여 침전지 초반에 가라앉을 수 있도록 유도하여 탁도 및 슬러지양을 비교하였다. 응집제만 투입한 경우보다 시료를 투입한 경우가 탁도제거율과 슬러지양이 상승하는 것을 볼 수 있으며 그중에서도 규사의 경우가 가장 많은 탁도제거율의 상승을 나타냈다. 또한 이중 정류벽을 설치하여 탁도 및 슬러지양을 측정한 결과 이중정류벽을 설치하지 않은 경우보다 탁도제거율 및 슬러지양 또한 높게 측정되었으며 슬러지의 양 또한 침전지 앞부분에 집중되는 것으로 나타났다. 이러한 경우 상기 플럭의 질량이 증가하기 때문에 처리속도를 높이고, 체류시간을 줄이고, 처리를 효율적으로 안정되게 수행하는 것이 가능하다. 본 연구결과를 바탕으로 정수시설의 설치에 있어 시료와 이중정류벽을 함께 사용할 경우 응집제의 절감 또는 침전지의 컴팩트화를 가져올 것으로 예상된다.

  • PDF

The Separation of Particulate within PFC Decontamination Wastewater Generated by PFC Decontamination (PFC 제염 후 발생된 제염폐액 내 오염입자의 제거)

  • Kim Gye-Nam;Lee Sung-Yeol;Won Hui-Jun;Jung Chong-Hun;Oh Won-Zin;Park Jin-Ho;narayan M.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.32-39
    • /
    • 2005
  • When PFC(Perfluorocarbonate) decontamination technology is applied to removal of radioactive contaminated particulate adhered at surface during the operation of nuclear research facilities, it is necessary to develop a filtration equipment to reuse of PFC solution due to high price, also to minimize the volume of second wastewater. Contaminated characteristics of hot particulate was investigated and a filtration process was presented to remove suspended radioactive particulate from PFC decontamination wastewater generated on PFC decontamination. The range of size of hot particulate adhered at the surface of research facilities measured by SEM was $0.1{\sim}10{\mu}m$. Hot particulate of more than $2{\mu}m$ in PFC contamination wastewater was removed by first filter and then hot particulate of more than $0.2{\mu}m$ was removed by second filter. Results of filter experiments showed that filtration efficiency of PVDF(Poly vinylidene fluoride), PP(Polypropylene), Ceramic filter was $95{\sim}97\%$. A ceramic filter showed a higher filtration efficiency with a little low permeate volume. Also, a ceramic of inorganic compound could be broken easily on experiment and has a high price but was highly stable at radioactivity in comparison of PVDF and PP of a macromolecule which generate $H_2$ gas in alpha radioactivity environment.

  • PDF

Performance Improvement of Scrubber by Introducing $TiO_2$ Photocatalytic Nanoparticles ($TiO_2$ 광촉매를 이용한 스크러버 집진장치의 성능 향상에 대한 연구)

  • 천세경;곽승엽
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.31-31
    • /
    • 2003
  • 최근 각종 산업 기술의 발달과 함께 다량의 악취, 오염 물질이 심각한 사회문제로 대두되고 있다. 특히 산업 현장의 경우, 악취로 인해 작업 환경이 매우 열악하여 환경 설비의 개발이 절실히 요구되고 있다. 본 연구에서는 기존의 스크러버 집진 장치의 친수성 가스를 제거할 수 있는 장점을 유지하면서, 소수성 기체의 제거율이 낮은 단점을 보완할 수 있는 TiO$_2$나노 입자의 광분해 특성을 이용한 스크러버 집진 장치를 제작하였다. TiO$_2$ 광촉매 나노 입자는 실험실에서 합성한 QT를 비롯하여, 국내외에서 생산된 P-25, NT-20, ST-01로 특성 분석을 실시하였다. 광촉매 나노 입자의 특성 분석에는 X선 회절 분석법, 적외선 분광기, 제타 전위 분석기, 동적 광산란 분광기를 사용하였으며, 그 결과 ST-01이 본 실험에 가장 적합한 광촉매로 선정되었다. 악취 및 대기 오염 물질 선정은 염색 가공 공장에서 정련제, 산화 환원제등으로 많이 사용하고 있는 암모니아, 아세트산, 옥탄올, 휘발성 유기물질인 톨루엔, 벤젠으로 하여, 실험실 자체 제작한 batch type과 산업 현장에서 사용할 수 있는 continuous type의 스크러버 이용하여 실험하였다. 이들 물질의 제거율은 가스 크로마토그래피, 자외선/가시광선 분광기를 이용하여 조사하였으며, 친수성 기체인 암모니아와 아세트산의 경우는 기존의 스크러버 효율의 약 70%인 반면에, 광촉매를 이용한 스크러버의 경우 90%이상의 우수한 제거 효과를 보였다. 또한, 기존의 스크러버가 거의 분해를 할 수 없었던 소수성 기체 옥탄올, 톨루엔, 벤젠의 경우는 기존의 스크러버가 약 10%내외를 제거하는 것에 비해, 광촉매를 이용한 스크러버의 경우 약 80% 이상의 제거 효율을 나타내었다. 결과적으로 광촉매를 이용한 스크러버의 제거효율이 기존의 스크러버에 비해, 친수성 가스의 경우 20% 이상, 소수성 가스의 경우70% 이상 향상되었음을 알 수 있었으며, 본 연구를 통해 광분해를 이용한 스크러버가 기존설비의 장.단점을 충분히 보완 가능한 환경 설비임을 확인할 수 있었다.

  • PDF

Reduction of PCBs in Contaminated Marine Sediments by Using Fenton-like Reaction with Surfactants (유사-펜톤 반응과 계면활성제에 의한 해양퇴적물의 PCBs 정화)

  • Choi, Jin Young;Kim, Kyoungrean
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.6
    • /
    • pp.340-348
    • /
    • 2015
  • Removal efficiency of PCBs in contaminated marine sediments treated by Fenton-like oxidation combined with surfactant was investigated in this research in order to achieve remediation of PCBs. A washing treatment using various concentrations of hydrogen peroxide (1% and 15%) and surfactants (Triton X-100, Tween 60 and Tween 80) was evaluated at various conditions in laboratory scale experiments. The mean removal efficiencies of tPCBs varied from 24.1 to 46.7% in the sediments for 1 hour duration of the treatments. The concentration of tPCBs in contaminated marine sediments after the simultaneous treatment with hydrogen peroxide and surfactant satisfied the domestic environmental standards for the beneficial use of sediments. When suitable surfactant was used for Fenton-like oxidation, the removal efficiency of tPCBs at low concentration of hydrogen peroxide was similar to that at high hydrogen peroxide concentration. Thus the efficient removal of PCBs in contaminated marine sediments could be achieved through treatment with Fenton-like oxidation combined with surfactant washing.

Membrane Characteristics for Removing Particulates in PFC Wastes (PFC제염폐액 내의 미립자 제거를 위한 여과막의 특성 연구)

  • Kim Gye-Nam;Lee Sung-Yeol;Won Hui-Jun;Jung Chong-Hun;Oh Won-Zin;Park Jin-Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.2
    • /
    • pp.149-157
    • /
    • 2005
  • PFC(Perfluorocarbon) decontamination process is one of best methods to remove hot particulate adhered at inside surface of hot cell and surface of equipment in hot cell. It was necessary to develop a particulate filtration equipment to reuse PFC solution used on PFC decontamination due to its high cost and to minimize the volume of second wastewater. Contamination characteristics of hot particulate were investigated and then a filtration process was presented to remove hot particulate in PFC solution generated through PFC decontamination process. The removal efficiency of PVDF(Poly vinylidene fluoride), PP(Polypropylene), Ceramic(Al$_{2}$O$_{3}$ filter showed more than 95$\%$. The removal efficiency of PVDF filter was a little lower than those of other kiters at same pressure(3psi). A ceramic filter showed a higher removal efficiency with other filters, while a little lower flux rate than other filters. Due to inorganic composition, a ceramic filter was highly stable against radio nuclides in comparison with PVDF and PP membrane, which generate H$_{2}$ gas in e-radioactivity atmosphere. Therefore, the adoption of ceramic filter is estimated to be suitable for the real nitration process.

  • PDF

Analysis of pollutant behavior in sediments in a Rain Garden through long-term monitoring (레인가든 내 장기모니터링을 통한 오염물질 거동분석)

  • Jeon, Minsu;Choi, Hyeseon;Reyes, N.J. DG.;Kim, Leehyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.339-339
    • /
    • 2020
  • 도시화로 인한 불투수면적의 증가와 기후 변화로 인한 강우패턴의 변화 자연적 물순환 체계에 악영향을 미치며. 이를 해결하기 위하여 국내에서는 도시 내 빗물관리 및 비점오염원 저감이 가능한 저영향개발(Low Impact Development, LID)를 적용하고 있다. 건기시 도로, 주차장등 차량통행 및 유동인구가 많은 지역에서는 입자상 물질들이 많이 발생되어 노면에 축적되어 있다가 강우시 강우유출수를 통해 시설로 유입된다. 이로 인해 시설 내 오염물질 및 퇴적물이 축적되어 여재 공극막힘현상 및 침투율저하의 문제가 발생되어 시설 내 효율이 감소된다. 따라서, 레인가든의 장기 모니터링을 통해 시설 내 유입되는 오염물질의 성상 분석 및 시설 내부의 퇴적물 분석을 통해 LID시설 운영의 효율성 평가를 수행하였다. 모니터링은 강우시 모니터링과 건기시 집수구역, 침강지, 시설 상부, 중부, 하부 등 총 5곳에서 채취하여 분석을 수행하였다. 모니터링은 평균 선행건기 일수는 5.46±4.7 days, 평균 강우량은 14.31±11.4 mm, 평균 강우강도는 5.33±6.7 mm/hr의 강우사상에서 모니터링을 수행하였다. 시설 내 평균 유입수농도는 TSS 98.0 ± 32.7 mg / L, COD 133.6 ± 6.3 mg / L, TN 5.77 ± 4.05 mg, TP 0.54 ± 0.03 mg / L으로 분석되었다. 유입부 내 퇴적물 종류는 Sandy Clay Loam으로 나타났으며, Cr 0.36mg / kg, Cu 5.17 mg / kg and Pb 6.04 mg / kg으로 중금속의 함유량이 높은것으로 분석되었다. 퇴적물은 침강지 및 시설 유입부에서의 입자크기는 49-113㎛ 약 60%의 퇴적물이 축적되어 제거되는 것으로 나타났다. 시설 내 침강지에서 50㎛ 이상의 입자들이 여과, 흡착 및 침전으로 인하여 40% 이상의 입자들이 제거되는 것으로 분석되었으며, 50㎛ 미만의 입자들은 시설 내 중간부, 유출부에서 제거되는 것으로 분석되었다. 침강지에서 유입수 대부분의 입자상물질들이 흡착 및 여과로 인한 제거가 이루어지기에 침강지 여재부는 넓은 표면적, 우수한 흡착능 및 여과율을 고려하여 선정하영 하며, 잦은 교체를 위하여 중량성이 낮은 우드칩 등이 적당한 것으로 사료된다.

  • PDF

Study of post-cyclone using CFD (Computational fluid dynamics) (CFD를 이용한 PoC부착 고효율 싸이클론에 관한 연구)

  • 조영민;이주열
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.431-432
    • /
    • 2001
  • 원심력을 이용한 대표적인 대기오염 방지 장치인 싸이클론은 1800년대 후반이래 공기나 배출가스로부터의 분진제거 및 입자분리에 폭 넓게 사용되어 왔다. 일반적으로 싸이클론은 간단한 구조로 되어 있으며, 조작이 용이하고 운전비용이 저렴할 뿐만 아니라 가혹조건에서의 사용이 가능하다는 장점이 있다 (Shepherd and Lapple, 1939). 입자의 관성력에 의해 분진을 분리하는 싸이클론으로서는 상대적으로 낮은 관성효과를 지니는 미세입자(주로 10$\mu\textrm{m}$ 이하)들에 대한 제어효율이 낮을 수 밖에 없다(Dirge and Leith, 1985). (중략)

  • PDF

고급알코올을 이용한 토너의 응집 및 탈묵 기술

  • 허용성;이학래
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2001.04a
    • /
    • pp.26-26
    • /
    • 2001
  • 사무용 고지의 상당량을 차지하는 복사고지는 열과 압력으로 융착된 합성고분자 물질인 토너를 함유하고 있으며 이들 토너는 펄핑 후 크고 판상 형태의 잉크 입자를 형성하 여 기존의 부유부상법으로 제거가 곤란한 문제점을 지니고 있었다. 이러한 문제점을 극복하 는 방안으로 응집제를 이용하는 방법을 검토하였다. 복사기용 인쇄 잉크로 널리 사용되는 토너 업자는 낮은 표면에너지를 가지는 소수 성 물질이므로 같은 표면 특성을 가지는 소수성 물질과 서로 잘 결합한다. 따라서 소수성의 응집제를 이용하면 분리된 토너 잉크업자를 응집시킬 수 있으며, 응집된 토너 응집체는 스 크린 또는 클리닝 같은 정선 공정을 이용하여 제거가 가능할 것이다. 따라서 복사고지를 효 과적으로 재활용할 수 있는 탈묵방법으로 응집제를 이용하여 토너 입자를 조대한 웅집체로 형성시키고 이를 기존 탈묵방법인 스크린처리로 제거하는 방법을 검토하였다. 본 연구에서는 고급알코올의 하나언 1 -octadecanol을 이용하여 기존의 탈묵 방법 인 부유부상법으로는 제거가 곤란한 토너 잉크의 업자를 웅집시켜 구형의 조대한 응집체로 형성시켜 이를 제거하는 기술에 대하여 연구하였다. 펄핑 시의 온도를 70C의 고온으로 설 정한 경우 토너 입자가 유리전이온도에 이르게 되며 이들 토너 입자는 응집제에 의하여 웅 집되어 구형으로 성장하는 특정이 뚜렷하였으며, 토너 응집체의 크기는 최대 800 µm에 이 르기까지 조대하게 성장하였다. 또한 슬롯 폭 $250\mu\textrm{m}$의 진동 스크린 처리에 의한 토너 제 거 효율 측정 결과 역시 이들 토너 업자 웅집체의 형태가 구형임을 보여주었다. 해리 및 응 집 처 리 시 의 pH를 3으로 조정 하였을 때 토너 입 자가 웅집 제인 1 -octadecanol에 의 해 가장 효과적으로 구형의 조대한 웅집체를 이루는 것으로 나타났으며, 스크련을 통한 토너 웅집체 제거효율이 향상되었다. 복사고지 내에 포함되어 있는 전분 또는 사이즈제는 웅집 효과를 떨어뜨리는 주요 인으로 나타났다.

  • PDF

Generation of Bi-modal Particles for Performance Evaluation of Air Cleaning Devices for Submicron Aerosols (나노/서브마이크론 에어로졸의 집진성능평가를 위한 이중모드 입자의 발생)

  • 지준호;황정호
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.97-98
    • /
    • 2003
  • 나노/서브마이크론 크기의 입자는 최근 유해 입자상 물질 제거 및 오염 제어나 물질 제조 등의 분야에서 관심이 높아지고 있다. 보통 환경 입자상 물질로 불리는 0.1~l $\mu\textrm{m}$ 범위의 서브마이크론 입자는 자동차, 공장, 발전소, 소각로 등의 연소 과정에서 발생되어 상당량이 대기로 배출되는데, 인체에 유입되면 호흡기 장애나 암을 유발하는 등의 나쁜 영향을 미친다. 특히, 관성력과 확산력에 의한 영향이 적고 하전 입자의 전기적인 이동도도 낮기 때문에 집진장치나 공기청정장치에서 집진효율이 가장 낮은 크기 범위이다. (중략)

  • PDF