• Title/Summary/Keyword: 입자누출

Search Result 45, Processing Time 0.025 seconds

Pilot-Scale Evaluation of Granular Filters Using Particle Distribution Analysis (여재구성에 따른 탁질입자 제거특성 및 효율 비교)

  • Ahn, Jong-Ho;Yoon, Jae-Heung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.5
    • /
    • pp.919-926
    • /
    • 2000
  • The experiment in this study was conducted as a part of an effort to evaluate filter performance with pilot-filters consisting of one mono-media and two dual-media columns. Particle distribution analysis using a particle counter is more sensitive and better than turbidity analysis in observing particle detachments and a breakthrough. In sand media filters having 1.5 m of available head, caution is needed in the head loss of the late stages of filtration, and for dual-media filters, appropriate media configuration and effluent Quality monitoring should be used for preventing the final breakthrough. Also the time of particle breakthrough in the dual media filter can be deferred by increasing bed depth, and it is necessary to use a filtration aid prior to filtration to prevent breakthrough of these intermediate sized particles in high filtration rate.

  • PDF

Log-normal Size Distribution Theory for Deposition of Polydisperse Aerosol Particles (대수정규분포를 이용한 다분산 에어로졸의 침착에 관한 연구)

  • 박성훈;이규원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.191-193
    • /
    • 1999
  • 닫힌 반응기 내부에 부유하는 에어로졸 입자들의 크기분포는 응집, 응축, 확산에 의한 침착, 중력침강 및 누출과 같은 여러 기작들에 의해 변화한다. 특히 확산 및 중력침강에 의해 일어나는 입자의 침착(deposition)은 에어로졸 측정기기의 오차분석, 호흡기내부의 미세입자 침착, 건물내부의 입자상 물질의 농도 및 크기분포 변화 등 여러 응용분야에 관련되는 중요한 기작이다.(중략)

  • PDF

Development of a Lagrangian Stochastic Dispersion Model for Toxic Gas Release (독성 기체상 물질의 확산 및 대응 분석을 위한 라그랑지안 입자모델의 개발)

  • 이강웅;장유운;이미혜;조성억;조승현
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.149-151
    • /
    • 1999
  • 우리 나라의 경우에 산업화가 가속화되면서 유해 독성 기체상 물질의 누출사고 위험성이 점점 높아져 가고 있는 실정이다. 우리 나라는 특히 산업인력의 조달과 지방경제 발달을 목적으로 중소도시 근방에 대규모 공단이 건설되어 있는 경우가 많다. 이러한 공단에는 위험물을 취급하는 공장과 위험물이 수송 및 이동되는 사례가 매우 많을 것으로 추정되며 이러한 경로를 통하여 유독가스 누출사고가 발생 할 경우 바로 인근 주민 및 작업 인원들의 생명을 위협할 수 있다.(중략)

  • PDF

The 3-D Simulation of Electrophoresis Method in Leachate System for Repairing of Leaks in Waste Landfill Geomembrane Liner (폐기물 매립지 차수층 누출시 전기영동 복원을 위한 침출수 환경에서의 3차원 형상 모사 연구)

  • Han, Sang-Jae;Kim, Jong-Yun;Kim, Byung-Il;Kim, Soo-Sam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1C
    • /
    • pp.17-25
    • /
    • 2010
  • Electrophoresis may offer a new technique to repair in service leaking geomembrane liner of municipal solid waste (MSW) impoundment. The method involves introducing a suspended clay particles, which are charged negatively, into the leakage in geomembrane liners by electrokinetic phenomena and formation of clay cake around leakage for prevention of leachate outflows. Therefore, the 3-dimensional leakage simulation experiments are conducted to evaluate the field applicability of sealing leaks of waste impoundment. In addition, the adequateness of optimum influence factors deduced from 1-dimensional experiments is evaluated. After the test, the total size (width, length) of clay cake formation around leak is increased with enlargement of leakage diameter and distance decrease detween anode and cathode.

Electrophoretic Characteristics of the Clay Particles Affected by Chemical Species of Leachate (매립지 침출수 화학종에 따른 점토입자의 전기영동 특성)

  • Kim, Jong-Yun;Han, Sang-Jae;Kim, Soo-Sam;Park, Jea-Man
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5C
    • /
    • pp.217-228
    • /
    • 2009
  • In case of application of electrophoresis method for leakage restoration of waste impoundment, main points of consideration were to evaluate the mobility of clay particles by electrophoretic force and capacity of leakage repair in leachate electrolyte system contained with various chemical species. However, the flocculation phenomena of clay particles induced by electrochemical interaction between various chemical species and clay particles would cause the big problems in electrophoresis method. Therefore, a series of laboratory tests such as one-dimensional electrophoresis and gravitational experiments were carried out in order to identify the specific chemical species affected flocculation of clay particles and the range of chemical concentration in leachate. In addition, the characteristics of clay particle behavior with chemical species and concentration range in leachate were analized using the concept of the settling velocity, zeta potential, and electrophoretic velocity.

MICROLEAKAGE OF 2-STEP ADHESIVE SYSTEMS IN DIAMOND-PREPARED CAVITY (다이아몬드 기구로 삭제한 와동에서 2단계 접착제의 미세누출 비교)

  • Lee, Myung-Goo;Cho, Kwon-Hwan;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.5
    • /
    • pp.437-444
    • /
    • 2007
  • The purpose of this study was to compare the marginal microleakage of different 2-step adhesive systems in Class V cavities prepared with different diamond points. Forty Class V cavities were prepared with two different (coarse or fine) diamond points on cervical third of extracted molars. The occlusal and gingival margin of cavities was located in enamel and dentin, respectively. They were divided into one of four equal groups (n = 10) and ; Group 1-prepared with coarse diamond point (EX-41), restored with Single Bond and Z 250, Group 2-prepared with fine diamond piont (TF-21F), restored with Sing)e Bond and Z 250, Group 3-prepared with coarse diamond point (EX-41), restored with Clearfil SE Bond and Clearfil AP-X, Group 4-prepared with fine diamond point (TF-21F), restored with Clearfil SE Bond and Clearfil AP-X. Specimens were thermocycled, immersed in a 2% methylene blue solution for 24 hours, and bisected longitudinally. They were observed leakages at enamel and dentinal margins. Data were analyzed using Mann-Whitney and Wilcoxon signed ranked test. In this study, marginal microleakage or Single Bond was not affected by type of diamond points. But Clearfil SE Bond showed higher marginal microleakage at both enamel and dentinal margin when Class V cavity was prepared with coarse diamond point.

EFFECT OF MICROLEAKAGE OF A SELF-ETCHING PRIMER ADHESIVE ACCORDING TO TYPES OF CUTTING INSTRUMENTS (삭제기구가 자가 산부식 접착제의 미세누출에 미치는 영향)

  • Kim, Yong-Hee;Park, Jae-Gu;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.327-334
    • /
    • 2007
  • The purpose of this study was to evaluate the effect of burs on microleakage of Class V resin restorations when a self-etching primer adhesive was used. Forty Class V cavities were prepared with four different cutting burs on extracted third molars, and divided into one of four equal groups (n = 10); Group 1-plain cut carbide bur (no. 245), Group 2-cross cut carbide bur (no. 557), Group 3-fine diamond bur (TF-21F), Group 4-standard diamond bur (EX-41). The occlusal and gingival margin of cavities was located in enamel and dentin, respectively. Cavities were treated with Clearfil SE Bond and restored with Clearfil AP-X. Specimens were thermocycled, immersed in a 2% methylene blue solution for 24 hours, and bisected longitudinally. They were observed leakages at enamel and dentinal margins. Data were analyzed using Mann-Whitney and Wilcoxon signed ranked test. The results of this study were as follows; 1. At enamel margin, microleakage of group 4 was statistically higher than those of group 1, 2 and 3 (p < 0.01). 2. At dentinal margin, microleakage of group 4 was statistically higher than group 3 (p < 0.01), but group 1 and 2 were not statistically different with group 3 and 4. 3. Enamel microleakage was statistically higher than dentinal microleakage in group 1, 2 and 3 (p < 0.05), but statistical difference between the microleakage of enamel and dentinal margin was not in Group 4. In conclusion, the use of coarse diamond bur showed high microleakage at both enamel and dentinal margin when Clearfil SE Bond was used in class V cavity.

Influence of Filtrate Quality by Variation of Operating Filter Number Based on Inflow (유입유량과 연계한 여과지 가동지수 변동 운영이 여과수 수질에 미치는 영향)

  • Kim, Jin-Keun;Lee, Jung-Tack
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.817-824
    • /
    • 2009
  • To prevent turbidity breakthrough in a depth filter caused by hydraulic shock loads, influence of turbidity and particle number in filtrate by variation of operating filter number depending on inflow change was investigated. Inflow quantity at the S water treatment plant (WTP) was varied and ratio of maximum/minimum inflow quantity was 2.2, therefore filtration velocity was also subsequently changed. The S WTP changed operating filter number depending on inflow variation to minimize change of filtration velocity. Particle breakthrough was not severe when operation system was changed, out-of-operation and re-start of filter was repeated depending on inflow quantity. Slight particle breakthrough was noticed when re-start of filter was implemented at the filter that had a cumulative filtration run time of less than 10 h or more than 50 h. This can be attributed to the inadequate ripening and over accumulation of particles on media. Therefore, it is more efficient to choose a re-starting filter basin which has cumulative filtration run time more than 10 h or less than 50 h to reduce particle breakthrough. Filter number variation depending on inflow change was proven to be a method for improvement of unit filter run volume (UFRV).

A STUDY ON THE HYGROSCOPIC EXPANSION OF COMPOMER (컴포머의 수화팽창에 관한 연구)

  • Park, Kyung-Jin;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.1
    • /
    • pp.11-18
    • /
    • 2002
  • Compomer, like resin composite, undergoes shrinkage during setting. But, due to the structure of glass ionomers and their hydrophilic nature, water sorption and subsequent expansion may lead to compensation of the shrinkage. The purpose of this study was to, evaluate the change of mliroleakage after 30day-water-storage of compomer and composite resin. 40 sound third molars were used for the microleakage test. Z-100 resin was used for the control groups(Group I and III), Dyract AP for the experimental groups(Group II and IV). The storage time was 1 day in Group I, II and 30days in Group III, IV. The result from the this study can be summarized as follows; 1. No significant difference could be found in microleakage of occlusal margin between each group(p>0.05). 2. In microleakage of gingival margin, no significant difference could be found between group I and II, and between group I and III (p>0.05). 3. Group IV was showed less microleakage than group II and group III in gingival margin(p<0.05).

  • PDF

광양만의 해수 교환

  • 최병호;김동철;고진석
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 1996.10a
    • /
    • pp.84-88
    • /
    • 1996
  • 본 연구에서는 전회의 남해도해역조석수치모형(최 등, 1995)을 확장하여 가막양이 포함되도록 조석수치모형을 수립하였다. 개체 식별 가능한 다수의 입자가 M$_2$ 조석 주기 동안 이동되도록 수치실험을 행하였고 여수해만 입구와 노량수도 및 창선해협과 대방수도를 경계로 교환량을 평가하고 광양만 및 진주만의 해수 교환률을 산정하였다. 95년 7월의 씨프린스호 사고에 이어 7월 17일 호남정유의 호남 사파이어호의 누출유 사고는 18일 밤부터 여수시 돌산대교를 거쳐 청정해역인 가막양으로까지 확산되었는바 본 고에서는 광양만 일대의 오염물질 확산거동을 수치적으로 연구하기 위한 초기단계의 과업을 수행하였다. (중략)

  • PDF