• Title/Summary/Keyword: 입구 유속

Search Result 152, Processing Time 0.028 seconds

The Study on The Ventilated Flow in The Railway Tunnel Mock-Up for Tunnel Fire-Driven Flow Experiment (철도터널 화재유동 실험을 위한 모형 터널에서의 환기 유동 형태에 관한 연구)

  • Jang, Yong-Jun;Kim, Seung-Tae;Kim, Dong-Hyeon;Park, Won-Hee
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1781-1788
    • /
    • 2008
  • This report is the result of a basic experiment done on a mock-up tunnel, of what happens to the ventilated flow and fire driven flow inside a railway tunnel as the current inside the tunnel changes when an anti-smoke or a radio frequency invert control is installed. The duct used in this experiment is 10m in length, 0.5m in height and 0.25m in width and made of acrylic. An anti-smoke system with a motor that can produce current of 10m/sec maximum in order to create ventilated flow, has been installed. A honeycomb has been installed at the entrance of the duct to create a current flow that exists in tunnels. In order to create a ventilated flow, a current of 4m/s, 6m/s and 8m/s were generated using the anti-smoke system, as the study of current developed. A Hot-wire(TSI) and Pressure sensor(ENDEVCO) was installed in the duct, 1m apart, as the measurement of current and pressure went on. The current and pressure were automatically measured through the Lap View program and PC; the current flow in the mock-up tunnel generated by the honeycomb has been analyzed the pressure distribution and pressure drop has been analyzed.

  • PDF

Effect of Combustion Instability on Heat Transfer in a Subscale Thrust Chamber (연소불안정에 따른 축소형 연소기에서의 열전달 영향)

  • Ahn, Kyubok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3403-3409
    • /
    • 2014
  • Hot-firing tests were carried out using a mixing head with 19 swirl coaxial injectors and a combustion chamber with internal cooling channels. The propellants of liquid oxygen and kerosene(Jet A-1) were burned in a range of chamber pressures (59~82 bar) and mixture ratios (2.0~3.0). The temperature of water used as the cooling fluid was measured at the inlet and outlet of the cooling channels, and the heat flux was calculated. The aim of this study was to examine the effect of combustion instability on heat transfer in a subscale thrust chamber, and detect the temperature variation of cooling water. During several hot-firing tests, combustion instability was encountered which caused a 5~20% increase in heat flux. The peak heat flux took place in the initial stages of combustion instability.

Numerical Analysis of Concentration Polarization for Spacer Configuration in Plate Type Membrane Module (평판형 분리막 모듈 내 스페이서 형태에 따른 농도분극에 관한 수치해석)

  • Shin, Ho Chul;Chung, Kun Yong
    • Applied Chemistry for Engineering
    • /
    • v.22 no.6
    • /
    • pp.703-710
    • /
    • 2011
  • As the spacer in the membrane module provide the channel space to flow the feed solution smoothly and induce the flow turbulence, it could help to reduce both the concentration polarization and to take the long-term operation of membrane modules with high permeate flux by mixing the accumulated contaminants on the membrane surface into the bulk solution. In this study, the concentration distribution in membrane module with respect to the spacers which have the cross-sectional shapes of circle, cross, diamond and hexagon, the angles of spacer configuration, solute rejection and permeate flux were interpreted and optimized numerically using the "COMSOL Multiphysics" software. The concentration on the membrane surface was kept the lowest level for the cross-shape among the above four types of spacers. Also the 30 degree spacer configuration was showed as the most efficient case. The concentrations on the membrane surface at the module outlet for without spacer and the cross shape with the 30 degree spacer configuration were 2.09 and 1.29 times higher than those at inlet, respectively. The reduction effect of concentration polarization increased rapidly as the permeate flux increased.

Investigation on sample throughput of large scale splitter-less gravitational SPLITT fractionation (GSF) (Large scale Gravitational SPLITT Fractionation (GSF)에서의 시료 throughput에 관한 연구)

  • Choi, Hyo Jae;Kim, Woon Jung;Eum, Chul Hun;Lee, Seungho
    • Analytical Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.34-41
    • /
    • 2013
  • Split-flow thin cell (SPLITT) fractionation (SF) is a rapid separation technique capable of separating colloidal particles or macromolecules into two or more fractions. SF allows fractionations in a preparative scale as sample is fed continuously. Generally SF uses a thin ribbon-like channel equipped with two flow stream splitters at the inlet and outlet of the channel. Thus there exist two flow inlets and two flow outlets at the top and bottom of the inlet and outlet of the channel, respectively. There are two operating modes in SF, conventional mode and full-feed mode (FFD). Although the resolution in the FFD mode is lower than that in the conventional mode, FFD mode has some merits. The design of the channel and operation are simpler in the FFD mode, as it does not require the feeding of the solvent. Thus there is no flow stream splitter at the channel inlet, and only one pump is needed, unlike the conventional mode, where two pumps are required for the feedings of the sample and the solvent separately. Also the sample is not diluted in the FFD mode as there is no solvent feeding, which is important for fractionation samples with low colloidal concentrations such as environmental samples. For some of environmental samples, pre-concentration is often required. In this study, a new large-scale splitter-less FFD-SF channel was implemented, where there is no splitter at the outlet as well as at the inlet of the channel. It was possible to build the channel in a much larger dimension than conventional ones, allowing much higher sample throughput (TP). The new channel was tested and optimized with polyurethane (PU) latex beads, and then applied to large-scale separation of Polyacrylate (PA).

Nonlinear variation of performance for a NAFION membrane humidifier with inlet temperature elevation (입구 온도에 따른 나피온 막 가습기 성능의 비선형적 변화)

  • Hwang, J.Y.;Kang, K.;Kang, H.S.;Kim, J.H.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.78.2-78.2
    • /
    • 2010
  • Effect of temperature elevation of inlet air on performance of a membrane humidifier for PEMFC vehicle application was investigated both experimentally and numerically. A shell-and-tube typed gas-to-gas humidifier with Nafion membrane was tested. The experimental result showed that water transfer varies nonlinearly with the temperature elevation. Numerical analysis based on detailed modeling is also conducted on a single tube geometry to explain this nonlinear behavior. The simulation revealed that the local water flux varies nolineary and dramatically along the tube. Analysis is based on competing role of temperature increase and relative humidity decrease, both of which seriously affect water conductivity of the membrane.

  • PDF

NUMERICAL STUDY OF AIR POLLUTION RATE DEPENDING ON TYPES OF VENTILATION SYSTEM IN UNDERGROUND PARKING LOT (환기방식에 따른 지하주차장 공기오염도의 수치연구)

  • Lim, Soo-Jung;Jang, Choon-Man;Rhee, Gwang-Hoon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.208-214
    • /
    • 2009
  • 지하 복수층 주차장은 도시의 밀집화 및 자동차의 급격한 증가로 인한 토지부족 및 주차난을 해소할 수 있는 좋은 방법이다. 하지만 인체유해 배출가스의 집중으로 환기의 중요성이 대두되는 추세에도 불구하고 실제로는 시공이 완료 된 후에나 오염도 측정이 가능하다. 이러한 이유로 CFD 시뮬레이션으로 시공이전의 지하 복수층 주차장의 공기오염도를 예측했다. CFD 시뮬레이션은 예산과 시간을 절감한 공기오염도 예측이 가능하다. 실제의 당산근린공원의 지하주차장을 대상으로 오염도를 예측했다. 급기에만 강제유동을 일으키는 2종과 배기에만 강제유동을 일으키는 3종 기계환기법, 그리고 급배기에 강제유동을 일으키는 1종기계환기법을 각각 적용하여 공기오염도를 계산했다. 지하1층과 지하2층의 입구 및 출구유속을 10, 15m/s로 하여 실내평균연령과 실내평균환기효율을 살펴보았다. 계산결과는 급기와 배기에 강제유동을 동시에 일으키는 1종 기계환기법의 값과 비교하였다.

  • PDF

수치해석을 이용한 화학제주입탱크의 주입시간 특성분석

  • 박병호;김은기;김유환;고용상;장근선
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.55-60
    • /
    • 1996
  • 원자력발전소 운전시 원자로냉각재는 부식 방지를 위해 적절한 화학물질을 함유하고 있어야한다. 이러한 원자로냉각재의 수질화학 조절은 유량조절 기능과 화학제주입 기능을 가진 화학 및 체적제어계통의 화학제주입탱크 및 체적제어탱크에 의하여 이루어진다. 본 연구에서는 영광5,6호기에서 화학제주입계통의 연결위치를 충전펌프 후단에서 전단으로 변경하고, 원자로보충수펌프에 의하여 화학제주입을 수행할 경우 요구되는 주입운전시간 특성에 대해 수치해석을 이용하여 분석하였다. 분석은 설계요건에서 요구되는 화학제주입탱크의 용량 및 주입유량을 고정하고 탱크의 구조적형상 변경, disk block 설치 및 주입속도를 변경(입구배관 크기 변경)하여 각각의 경우에 대하여 시간변화에 대한 탱크 내에서의 유속분포, 농도분포, 평균농도 등 을 구하였다. 분석결과 발전소의 빠른 화학제주입운전을 위해서는 탱크 내에 혼합효과를 중대 시킬 수 있는 disk block의 설치가 요구됨을 알 수 있었다.

  • PDF

Heat Transfer Performance of Pond Loop type Heat Exchanger for Ground Source Heat Pump using Extruding Ground Water (유출지하수 열원 지열히트펌프용 Pond Loop 열교환기의 열전달 성능)

  • Park, Geun-Woo;Kim, Yoon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.105-107
    • /
    • 2006
  • 유출지하수나 지료수를 열원으로 하는 지열히트펌프의 기초자료로 활용하기 위하여 Pond Loop형 열교환기를 설계, 제작하여 유동이 없는 수조 내에서 수조의 온도가 변화함에 따라 일정한 열교환기 입구온도를 유지하면서 열전달량을 측정하였다. 그 결과 수조를 Heat Source로 사용하는 경우 5,500${\sim}$4,500 kcal/h의 열량이 전달되었고, 수조를 Heat Sink로 사용할 경우 5,200${\sim}$3,500 kcal/h의 열량이 전달되었다. 또한 열교환기 관내 유속이 증가함에 따라 열전달량이 증가하는 경향성을 확인할 수 있었고, 이는 동시에 열교환기 입출구의 차압을 증가시킴을 알 수 있었다. 열교환기의 설계단계애서 사용하였던 열전달관계식으로 구한 총괄열전달계수, U와 실험값을 통해 유추한 U값을 비교 한 결과 실험에 의해 유추된 U값이 24${\sim}$27% 설계치 보다 크게 나타났다. 본 연구를 통하여 유출지하수 뿐만 아니라 하수 및 하천수를 이용한 지열히트펌프의 기초자료를 확보할 수 있었다.

  • PDF

Optimization of inlet velocity profile for uniform epitaxial growth (균일한 에피층 성장을 위한 입구 유속분포 최적화)

  • Cho W. K.;Choi D. H.;Kim M.-U.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.11a
    • /
    • pp.121-126
    • /
    • 1998
  • A numerical optimization procedure is developed to find the inlet velocity profile that yields the most uniform epitaxial layer in a vertical MOCVD reactor. It involves the solution of fully elliptic equations of motion, temperature, and concentration; the finite volume method based on SIMPLE algorithm has been adopted to solve the Navier-Stokes equations. The overall optimization process is highly nonlinear and has been efficiently treated by the sequential linear programming technique that breaks the non-linear problem into a series of linear ones. The optimal profile approximated by a 6th-degree Chebyshev polynomial is very successful in reducing the spatial non-uniformity of the growth rate. The optimization is particularly effective to the high Reynolds number flow. It is also found that a properly constructed inlet velocity profile can suppress the buoyancy driven secondary flow and improve the growth-rate uniformity.

  • PDF

Numerical Simulation of Tidal Current Patterns for Estuary Morphological Changes using Simple 2D Model (단순모델을 이용한 하구역 지형변화와 해수유동장 변화 수치모의)

  • Lee, Young-Bok;Yoon, Han-Sam;Ryu, Cheong-Ro
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.445-448
    • /
    • 2006
  • 본 연구는 기초적인 연구로 낙동강 하구역을 단순 사각형 만의 형상을 가진 지형으로 설정하고 내부 지형의 변화(수심 및 사주 면적)에 따른 해수유동장을 해수유동 수심적분모델로 구축하여 계산하였다. 계산된 유속장 결과를 바탕으로 내부 지형의 대표단면에서의 단면유량플럭스를 계산하여 상호 비교함으로써 하구역내 사주의 생성 및 발달(내부 지형 용적 변화)에 따른 하구역 입구부에서의 해수용적 변화(순환)의 정도를 평가하고자 하였다.

  • PDF