• Title/Summary/Keyword: 입구안내익

Search Result 11, Processing Time 0.025 seconds

Studies on the improvement of driving gears quality at Inlet Guide Vane of aircraft auxiliary power unit (항공기 보조동력장치 입구안내익 구동기어의 품질개선에 관한 연구)

  • Park, Sungjae;Park, Sunwook;Suh, Jaekyoung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.6
    • /
    • pp.512-519
    • /
    • 2016
  • Auxiliary Power Unit of FA-50 which provides energy other than propulsion is an important element to maintain airworthiness on aircraft. Also Inlet Guide Vane of Auxiliary Power Unit is a device that supplies appropriate airflow into the Auxiliary Power Unit after adjusting influent airflow into the load compressor. This report, based on the problems occurred the driving gears of Inlet Guide Vane, deals with cause of occurrence, troubleshooting, design improvement and result of test flight verification for FA-50 aircraft Auxiliary Power Unit lifespan.

A Numerical Study on Transient Performance Behavior of a Turbofan Engine with Variable Inlet Guide Vane and Bleed Air Schedules (가변 입구 안내익과 블리드 공기 스케줄에 따른 터보팬 엔진에서의 천이 성능특성에 관한 수치연구)

  • Kim, Sangjo;Son, Changmin;Kim, Kuisoon;Kim, Myungho;Min, Seongki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.5
    • /
    • pp.52-61
    • /
    • 2015
  • This paper performed a numerical study to analyse the transient performance behavior of a turbofan engine with variable inlet guide vane (IGV) and bleed air schedules. The low bypass ratio mixed flow turbofan engine was considered in this study. For modeling the compressor performance with IGV, the performance maps were generated by using a one-dimensional meanline analysis and feed to the engine simulation program. The IGV and bleed air according to the rotating speed were scheduled to satisfy 10% of surge margin at steady-state condition. The transient engine performance analysis was conducted with the schedules. The engine with IGV schedule showed a higher surge margin and lower turbine inlet temperature than the engine with bleed air schedule during the transient period.

A Study on the Performance Prediction Method for an Axial Compressor with Variable Inlet Guide Vane (가변 입구 안내익이 있는 축류압축기의 성능예측 방법에 관한 연구)

  • Kim, Dong-Hyun;Kim, Sang-Jo;Kim, Kui-Soon;Son, Chang-Min;Kim, You-Il;Min, Seong-Ki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.4
    • /
    • pp.1-8
    • /
    • 2012
  • In this study, numerical method, stage stacking method based on the result of numerical method and scaled stage stacking method have been applied to predict the performance of a multi-stage axial compressor with inlet guide vane. The results obtained through three different methods for off-design conditions were compared with performance test data. And the effect the angle of variable inlet guide vane was also investigated. The three-dimensional numerical simulation has been performed by using flow analysis program, $FLUENT^{TM}$ 6.3 and the performance prediction based on the stage stacking method has been performed with compressor analysis code from NASA.

Experimental Study on the Effect of Inlet Guide Vane of a Centrifugal Compressor (입구 안내익 영향으로 인한 원심 압축기 성능특성 시험연구)

  • Cha, Bong-Jun;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.5 no.3 s.16
    • /
    • pp.46-53
    • /
    • 2002
  • This paper reports an experimental investigation on a centrifugal compressor with the adjustable inlet guide vane. The compression system is composed of a radial impeller, a vaneless diffuser, and an IGV. The results have shown that surge line on the performance map is affected by the amount of prewhirl and the prewhirl has an effect on transient region between rotating stall and surge. The surge lines have been shifted toward the lower flow region with the increased positive prewhirl and the higher flow region with the increased negative prewhirl. During the unsteady performance test, it was also found that the transient region was reduced with the increased negative prewhirl, and weak signals of rotating stall were detected just before surge as the positive prewhirl was increased.

Experimental Study on the Effect of Inlet Guide Vane of Instabilities of a Centrifugal Compressor (입구 안내익 영향으로 인한 원심 압축기 불안정성 연구)

  • Lim, Byeung-Jun;Cha, Bong-Jun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.3 s.24
    • /
    • pp.23-31
    • /
    • 2004
  • An experimental study on the performance and instability development characteristics of a centrifugal compressor equipped with an adjustable inlet guide vane has been performed with varying guide vane angles. The test was conducted at the design speed of 20,800 rpm for 6 guide vane angles : $-30^{\circ},\;-20^{\circ},\;10^{\circ},\;0^{\circ},\;10^{\circ},\;20^{\circ},\;30^{\circ}$. Unsteady pressures were measured using high-frequency pressure transducers at the inducer to investigate the instability phenomena such as rotating stall and surge inside the compressor. From the unsteady measurements, it is found that the transient process from rotating stall to surge was mainly affected by inlet guide vane angles. The results of the present study can be applied to the instability control of the centrifugal compressors using a adjustable inlet guide vane.

An Approach for the Integrated Performance Analysis of a Small Turbofan engine with Variable Inlet Guide and Variable Stator Vane (가변 안내익 및 정익을 가지는 소형 터보팬 엔진의 성능예측을 위한 통합 해석법 연구)

  • Kim, Sang-Jo;Kim, Dong-Hyun;Son, Chang-Min;Kim, Kui-Soon;Kim, You-Il;Min, Seong-Ki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.4
    • /
    • pp.23-32
    • /
    • 2012
  • The present study is aimed to develop an integrated performance analysis approach for the application of a compressor with variable inlet guide vane (VIGV) and vairable stator vane (VSV) in a small turbofan engine. For the integrated analysis approach, an engine performance analysis program, NPSS and a computer program used for predicting of axial flow compressor performance based on stage stacking method, STGSTK were linked with an optimisation package, Isight. This enables off-design performance analysis for the turbofan engine with VIGV and VSV hence provides the capability to predict stable operation condition of the engine with acceptable surge margin.

Control System of Turbofan Engine with Variable Inlet Guide Vane (가변 안내익을 이용한 터보팬 엔진 제어시스템)

  • Bae, Kyoungwook;Min, Chanoh;Cheon, Bongkyu;Lee, Changyong;Lee, Daewoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.3
    • /
    • pp.237-242
    • /
    • 2014
  • Surge phenomenon can be occurred in a compressor when the performance of turbofan engine for an aircraft is changed considerably such as take-off phase. This study is aimed to avoid surge phenomenon. This paper propose the PID and Fuzzy control System for the turbofan engine with control inputs, the VIGV(Variable Inlet Guide Vane) in closed loop, and the fuel mass flow in open loop. We design the Dynamic modeling, NPSS S-function, which is connection block of simulink between NPSS(Engine analysis program) and Simulink. Finally, we certify the performance to prevent a serge phenomenon in the VIGV control system using the both methods, PID and fuzzy.

An Experimental Study on the Aerodynamic Performance of High-efficient, Small-scale, Vertical-axis Wind Turbine (고효율 소형 수직형 풍력터빈의 공력성능에 관한 실험적 연구)

  • Park, Jun-Yong;Lee, Myeong-Jae;Lee, Seung-Jin;Lee, Seung-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.8
    • /
    • pp.580-588
    • /
    • 2009
  • This paper summarizes the experimentally-measured performance of small-scale, vertical-axis wind turbine for the purpose of improving the aerodynamic efficiency and its controllability. The turbine is designed to have a Savonius-Type rotor with an inlet guide-vane and an side guide-vane so that it achieves a higher efficiency than any lift- or drag-based turbines. The main design factors for this high-efficient, vertical wind turbine are the number of blades (Z), and the aspect ratio of Height/Diameter (H/D) among many. The basic model has the diameter of 580mm, the height of 464mm, and the blade number of 10. The maximum power coefficient of 0.50 was experimentally measured for the above-mentioned specifications. The inlet-guide vane ensures the maximum efficiency when the angle of attack to the rotor blade lies between $15^{\circ}$ and $20^{\circ}$. This experimental results for the vertical-axis wind turbine can be applied to the preliminary design of turbine output curve based on the wind characteristics at the proposed site by controlling its aerodynamic performance given as a priori.

An Experimental Study on the Performance of the Vertical-Axis Wind Turbine (수직축 풍력터빈 성능개선에 관한 실험적 연구)

  • Kim, Byung-Kook;Kim, Young-Ho;Song, Woo-Seog;Lee, Seung-Bae;Nam, Sang-Kyu;Kim, Sa-Man
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.3 s.42
    • /
    • pp.17-24
    • /
    • 2007
  • This paper presents the design procedure of a vertical wind turbine named jet-wheel-turbo turbine and the numerical and experimental verifications. The design parameters such as the rotor inlet angle, the diameter-to-hub ratio, the inlet guide outlet angle and the solidity were optimized to maximize the energy transfer, and to further increase the turbine efficiency by applying the side guide vane and the side opening to the rotor. The maximum power coefficient of 0.59, which is much higher than the ever-designed three-bladed horizontal turbines, was experimentally obtained when the optimal inlet- and side-guide vanes were installed and both sides of the rotor were 80% opened. The maximum power coefficients occur at the tip speed ratio ranging between 0.6 and 0.7. This vertical-axis turbine model can be applied to the large-scale power generation system with the speed and torque control algorithm for the specified wind characteristics.

NUMERICAL PREDICTION OF THE OPTIMAL STAGGER ANGLES FOR A HIGH-POWER TURBO BLOWER (고마력 터보 블로어의 최적 깃배치각에 관한 수치 예측)

  • Park, T.G.;Chung, H.T.;Park, J.Y.;Sung, B.I.
    • Journal of computational fluids engineering
    • /
    • v.16 no.3
    • /
    • pp.75-81
    • /
    • 2011
  • The turbo blowers having large power capacity are generally composed of the variable inlet guide vane, the impeller and the variable diffuser. In the present study, the effect of the stagger angles on the aerodynamic performances has been investigated by CFD methods. The design specifications of the reference model having 400kW power were given as 7.43kg/s of mass flow rate, 1.66 of pressure ratio with 12000rpm of impeller rotating speed. As the first simulation parameter, the diffuser vane angle was varied in the range of ${\pm}$20 degree from the initial-design point. The inlet guide vane angles, as the second one, was changed in the range of ${\pm}$40 degree from the initial-design point. The commercial Navier-Stokes solver, ANSYS-CFX, was applied to solve the three-dimensional unsteady flow fields inside the turbo blower. Through the numerical results, the desirable setting angles were proposed to fit the best performance to the variation of the operating conditions.