• Title/Summary/Keyword: 입구덕트

Search Result 68, Processing Time 0.023 seconds

The Effect of Duct Inlet Condition on Flow Characteristics of Fan (덕트의 입구조건이 팬의 특성에 미치는 영향)

  • Kim, J.S.;Cho, K.R.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.217-224
    • /
    • 1995
  • The effects of duct inlet conditions on fan characteristics and upper wind velocity fields were investigated for two kinds of impellers. As the duct inlet condition, the relative positions between duct inlet and fan impeller and the size of baffle plate mounted on a duct inlet were selected. The 3-dimensional velocity components in flow fields were measured by a 5-holes pitot tube. From the results of measurements, it was found that the size of baffle plate scarecely effect on upper wind flow fields and characteristics of fan. It was also confirmed that the upper wind velocity distributions can be estimated by the potential flow field with large baffle plate at duct inlet.

  • PDF

Mixed Convection in an Asymmetrically Heated Vertical Parallel-Plate of Finite Length Duct Flow (비대칭적으로 가열된 유한 수직덕트내 유동의 혼합대류에 관한 연구)

  • ;B.F. Armaly
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.5
    • /
    • pp.1774-1780
    • /
    • 1991
  • 본 연구에서는 유한 길이를 갖는 수직 덕트내 공기 유동의 속도 분포를 LDV를 사용하여 측정하며 유동 특성에 미치는 가열정도, 덕트간격 및 입구소도등의 영향을 보고하고자 한다. 또한 속도분포, 온도분포 및 열전달에 미치는 부력의 영향을 수치 적으로 예측하여 그 타당성을 검증하고자 한다.

Numerical Investigation of Forward Flight Characteristics of Multi-Ducted Fan (다중 덕트 팬 전진 비행 특성에 대한 수치적 연구)

  • Roh, Nahyeon;Oh, Sejong;Park, Donghun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.2
    • /
    • pp.95-105
    • /
    • 2018
  • Increasing cruise speed is an important issue for the development of the next generation rotorcraft. Among several concepts proposed by previous research, the rotorcraft with ducted fan demonstrates its possibility of high-speed flight. In this study, numerical simulations are conducted to investigate the aerodynamic and flow characteristics of multi-ducted fan in forward flight. The aerodynamic efficiency around front ducted fan is determined by interaction between free-stream velocity and the induced velocity. While flow characteristics of rear ducted fan are dominantly influenced by the front ducted fan. Separation in the front ducted fan occurs faster than that of rear ducted fan, and the separation at duct inlet induces an increase of fan thrust. As a result of interaction effect between each ducted fan, relatively aligned inflow enters to the rear ducted fan. Therefore, thrust of the rear fan is decreased steadily before separation, and sudden changes of thrust in fans occur simultaneously. Due to the pressure decrease on lower surface, the normal force of rotorcraft is reduced with forward speed.

A Study on the Influence of S Shaped Annular Duct on the Centrifugal Compressor Performance (S자형 환형덕트가 원심압축기 성능에 미치는 영향에 관한 연구)

  • 정주현;전승배;김승우
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.2
    • /
    • pp.64-73
    • /
    • 1998
  • In twin spool aero-engine, there may be a S shaped annular duct between high pressure and low pressure spools. The flow passing this S shaped duct experiences the flow acceleration and deceleration due to the convex and concave surface of the duct as well as the increase of blockage according to the boundary layer growth along the surfaces. So, the high pressure compressor which is located behind the S shaped duct is influenced by the non-uniform flow field generated by the geometry of inlet duct. To study the influence of the S shaped duct on the centrifugal stage, performance tests were implemented for the compressor with straight cylindrical inlet duct and with S shaped inlet duct, respectively. The test results showed that the performance, such as pressure ratio and efficiency, of the compressor with S shaped duct was worse than that of the compressor with cylindrical duct. And the compressor with S shaped duct had reduced maximum flow rate around design speed. To investigate the cause of performance degradation, flow anlaysis was performed for the impeller in front of which is located S shaped annular duct. The result of CFD showed the strong acceleration of the flow in the axial direction around the inducer tip region which caused the increase of relative mach number and the decrease of incidence angle of the flow.

  • PDF

A Study on Flow Characteristics of the Inlet Shape for the S-Duct (S-Duct 입구 형상에 따른 유동 특성에 관한 연구)

  • Lee, Jihyeong;Choi, Hyunmin;Ryu, Minhyoung;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.2
    • /
    • pp.109-117
    • /
    • 2015
  • Aircraft needs an inlet duct to supply the airflow to engine face. A fighter aircraft that requires low radar observability has to hide the engine face in the fuselage to reduce the Radar Cross Section(RCS). Therefore, the flow path of the inlet duct is changed into S-shape. The performance of the aircraft engine is known to be influenced by the shape and the centerline curvature of the S-Duct. In this study, CFD analysis of the RAE M 2129 S-Duct has been performed to investigate the influence of aspect ratio of inlet geometry. The performance of the S-Duct is evaluated in terms of the distortion coefficient. To simulate the flow under adverse pressure gradient better, $k-{\omega}SST$ turbulence model is employed. The computational results are validated with the ARA experimental data. The secondary flow and the flow separation are observed for all computational cases, while the semi-circular geometry has been found to produce the best results.

Effects of an Inlet Guide Vane on the Flowrate Distribution Characteristics of the Nozzle Exit in a Defrost Duct System (성에제거 덕트 입구 가이드베인 형상이 노즐출구 유량분포특성에 미치는 영향)

  • Kim, Duck-Jin;Lee, Jee-Keun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.4
    • /
    • pp.88-96
    • /
    • 2008
  • Effects of the duct inlet guide vane on the flowrate distribution characteristics of the defroster nozzle exit in a defrost duct system were investigated experimentally to design the optimum heating, ventilation and air conditioning (HVAC) system applied in an automotive compartment. A 3-dimensional hot-wire anemometer system was used to measure the velocity field in the vicinity of the defroster nozzle jet flow and the velocity distributions near the windshield interior surface. At first, two cases of with- and without-duct inlet guide vanes were considered as the test condition, and then three cases of the duct inlet guide vane were tested to determine the optimum guide vane shape and their positions. The arrangement of the duct inlet guide vanes has an effect on the improved flowrate distribution at the defroster nozzle exit and near the windshield interior surface. However, the application of the lots of guide vane to control the flow direction leads to increase the flow resistance, resulting in the decreased flowrate issuing from the defroster nozzle. The shape of the duct inlet guide vane affects not only the flowrate distribution between the driver side and the assistant driver side but also the reduction of the flow resistance in the defrost duct system.

A Study on the Vibration Phenomena of the Duct-fan Systems in Fossil Fueled Boilers : Inlet Vortex Induced Excessive Vibration (화력 발전용 보일러 덕트-홴 시스템의 진동현상에 대한 연구 : 입구측 와류에 의한 과대진동 사례)

  • 김철홍;주영호
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.3
    • /
    • pp.194-201
    • /
    • 2003
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in a fan-duct system of fossil fueled boilers. We measured static pressure variation (pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this Paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

초고속선 점성유동

  • 김형태
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.32 no.1
    • /
    • pp.21-27
    • /
    • 1995
  • 초고속선에 관련된 점성유동은 저한성능 향상과 운항자세 제어를 위해 사용되는 다양한 선체부 가물의 저항 예측과 초고속선에 많이 사용되는 물분사 추진장치 입구 형상의 설계 그리고 임펠 러에 이르는 덕트 유동의 예측을 중심으로 관심을 받아왔다. 본 소고에서는 통상적인 선박의 경우와는 구별되는 초고속선 고유의 점성유동 특성에 관하여 간략히 논의하기로 하고 내용을 크게 선체-부가물 점성유동과 물분사 추진장치에 관련되어 있는 덕트유동으로 나누어 기술하 였다.

  • PDF

Intake Performance Characteristics according to S-duct Cross-section Shape in UAV (무인기 S형 흡기구의 단면 형상에 따른 흡기구 성능 특성)

  • Eom, Hee-Ok;Bae, Ji-Yeul;Lee, Namkyu;Kim, Jihyuk;Nam, Juyeong;Jo, Hana;Cho, Hyung Hee
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.5
    • /
    • pp.107-114
    • /
    • 2019
  • In many military aircraft, s-shaped diffusers are used to prevent the fan blades of the turbofan engine from being exposed to the outside. The inlet configurations of the air intakes for military aircraft vary, such as the rectangular intake of the F-22, the crescent-like intake of the F-16, elliptical intake of the MQ-25. In this study, the aerodynamic performance of s-shaped diffusers with various inlet configurations was evaluated using numerical analysis. In addition, the configuration of the middle section of an s-shape duct was changed to the crescent shape, and the effects on its aerodynamic performance were investigated. As a result, there was a slight difference in total pressure recovery according to various inlet configurations with ellipse-shaped middle sections. Also, the total pressure distortion was the lowest in the rectangular inlet shape. When the configuration of the middle section was changed from an ellipse to a crescent shape, the total pressure recovery remained at a high level, except for the ellipse-shaped inlet configuration. In terms of total pressure distortion, the duct with the crescent-shaped middle section showed a significantly more uniform pressure distribution than that with the ellipse-shaped middle section.

The Effects of Woven Metal Screen Ribs on Heat Transfer and Pressure Drops in the 5:1 Aspect Ratio Rectangular Duct (5:1의 형상비를 갖는 사각덕트에서 직조 스크린 리입(rib)이 열전달과 마찰계수에 미치는 영향)

  • Oh, S.K.;Ary, B.K.P.;Ahn, S.W.;Lee, M.S.
    • Journal of Power System Engineering
    • /
    • v.15 no.3
    • /
    • pp.31-37
    • /
    • 2011
  • 직조 금속 스크린 리브(rib) 이 바닥에 설치된 사각 덕트에서 열전달과 유체유동의 압력강하를 측정하기 위해 실험적 연구를 수행하였다. 시험부의 치수는 200 mm(W) ${\times}$ 40 mm(H) ${\times}$ 712 mm(L)이고 수력직경은 66.6 mm이다. 입구영역에는 1.72m 길이의 가열되지 않은 동일한 치수의 채널을 설치하였다. 메쉬가 다른 4가지의 직조금속 스크린 리브에 대해 측정하였다. 그리고 비교를 위해 일체형 리브에 대해서도 측정하였다. 국부 열전달 계수의 측정에는 스테인레스 강제 포일(foil) 히터와 T형 열전대률 이용하였다. 레이놀즈 수는 23,000에서 58,000의 범위이다. 덕트의 수력직경($D_h$)에 대한 직조 금속 리브의 높이(e)의 비($e/D_h$)는 0.075 이고 리브 간격(p)과 높이의 비(p/e)는 10이다. 실험 결과 메쉬가 없는 일체형 리입에서 가장 누셀트 수와 마찰계수가 컷다.