• Title/Summary/Keyword: 임피던스 모델

Search Result 290, Processing Time 0.023 seconds

A Study on the Characteristics of Natural Frequency and Impedance of Elastically Restrained Cracked Beam with a Tip Mass (말단질량을 갖는 탄성지지 균열보의 고유주파수와 임피던스 특성 연구)

  • Lee, Jong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.317-325
    • /
    • 2020
  • The development of a technique that can monitor the cracks, which is one of the typical types of damage, is necessary to secure the structural safety of elastically restrained cantilever-type beams with a tip mass that is used widely in infrastructure. Impedance techniques have been actively researched to detect cracks, and the cracks were estimated mainly by experimentally investigating the relationship between the crack and impedance signal. This study examined the correlation between the change in the impedance signals due to the crack, and the natural frequency obtained analytically. After updating the analysis model for the intact beam, the impedance signal was measured while gradually inflicting cracks in the cantilever-type beam, and the damage index was obtained. The results were compared with the natural frequencies calculated from the updated analysis model to investigate the correlation. A close correlation was observed between the experimentally obtained impedance damage index, and the analytically calculated natural frequency. Using this correlation, the structural characteristics could be evaluated more accurately from the damage estimation results, and the behavior of the structure could be predicted effectively using the analysis model.

Ground Impedance Characteristics Analysis of a Rod Type Grounding Electrode used for Distribution Systems (배전계통에 사용되는 봉형 접지전극의 접지 임피던스 특성 분석)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong;Kim, You-June;Choi, Jong-Ki;Baek, Nam-Woong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.67-74
    • /
    • 2005
  • Grounding insures a reference potential point for electric devices and also provides a low resistance path for fault currents in the earth. The ground impedance as a function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. In this paper, the ground impedance of Magic rods which are commercially available has been measured in frequency ranging from 0[Hz] up to 100[kHz] and an equivalent circuit model, transfer function model of the ground impedance are identified from the measured values.

Ground Impedance Characteristics Analysis of a Copper Rod-type Grounding Electrode used for Electric Distribution Systems (배전계통에 사용되는 동봉 접지전극의 접지 임피던스 특성 분석)

  • Kim, Kyung-Chul;Lee, Joo-Hong;Jin, Seong-Eun;Oh, Jung-Suk;Park, Sang-Young;Choi, Jong-Ki;Kim, You-June
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.46-51
    • /
    • 2005
  • Grounding insures a reference potential point for electric devices and also provides a low resistance path for fault currents in the earth. The ground impedance as a function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. A cower rod electrode is the most commonly used grounding electrode in electric distribution systems. In this paper, the ground impedance of cower rods has been measured in frequency ranging from 60[Hz] up to 100[kHz] and an equivalent circuit model, transfer function model of the ground impedance are identified from the measured values.

Study of Sound Quality Improvement for Car Audio System (자동차 오디오 시스템의 음질 개선 연구)

  • 박석태
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.123-129
    • /
    • 1995
  • 본 논문은 차실내 음향 특성 개선 연구로 수행중이며 정상 상태 음향 응답 특성 시험을 통하여 차실내에서 운전자가 듣게되는 음장 특성을 알게 되었고, 라우드 스피커에 대한 음향 특성 시험으로 이러한 차실내 음장의 비평탄성은 라우드 스피커 자체의 문제가 아니라 차실 공간등이 요인에 의한 것이라는 것을 추론할 수 있었다. 배플 상태 및 차량에 장착된 상태하의 라우드 스피커에 대한 임피던스 시험 결과로 임피던스의 장착 부위의 후면 공간이 임피던스 특성 변화를 가져오게 하는 것을 알 수 있었다. 임피던스 시험 결과를 이용하여 라우드 스피커에 대한 모델 매개 변수를 규명할 수 있었고, 이를 이용한 라우드 스피커의 모델 개선이 가능하게 되었다. 또한, 시간 지연 분광법을 이용하여 차실내에서 음향 전파 과정 분석을 할 수 있었고, 이로 인해 운전자가 시간에 따라 다른 음향 응답 특성으로 듣게 되는 것을 알게 되어 향후 음질 개선 연구 수행에 이용될 수 있다. 이러한 방법으로 음이 진행함에 따라 부딪치는 반사면의 흡음 또는 반사 특성을 파악할 수도 있어서 흡음재의 선정 및 라우드 스피커의 장착 위치 및 각도를 선정하는데 이용될 수도 있다. 향후의 연구 방향은 어떠한 음향 패턴이 운전자가 좋은 음향이라고 느끼게 되는지를 규명하는 것, 즉 주관적 평가와 객관적 시험 데이터 사이의 연관성을 확립하는 것과 라우드 스피커 모델링 기법과 차실 공간의 음향 특성을 이용한 차실내 최적 음향 조건을 규명하는 것이 될 것이다.

  • PDF

Impedance Characteristics of Overhead Medium-Voltage Power lines for Power Line Communication (전력선통신을 위한 고압 배전선로의 임피던스 특성)

  • Chun Dong-wan;Park Young-jin;Kim Kwan-ho;Shin Chull-chai
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.11
    • /
    • pp.67-78
    • /
    • 2005
  • In this paper, impedance characteristics of overhead medium-voltage (MV) power line for power line communication (PLC) is analyzed. For analysis, a two-port equivalent network model of MV power lines is derived. By applying the equivalent model and basic transmission line theory, input impedance at the signal induction part is calculated. And also calculated input impedance of power line itself that the medium voltage coupler and coaxial cable effect are removed. For verification, impedance of power lines is measured at a test field for an MV PLC. The results show that impedance of MV power line itself is between $200\;{\Omega}\;and\;300\;{\Omega}$ and converges to a half of their characteristic impedance with increasing frequency. And also measured data is very similar to calculated data.

The Transformer Winding Model for EMI Analysis (EMI 해석을 위한 트랜스포머 권선 모델)

  • 김태진
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.82-85
    • /
    • 2000
  • 본 논문에서는 EMI 주파수 대역에서 트랜스포머의 권선 임피던스 특성을 예측하는데 사용할 수 있는 트랜스포머 권선의 다중 공진 회로 모델을 제시하도록 한다. 제시되는 모델은 측정과 간단한 몇가지 계산을 통하여 바로 얻어질 수 있다. 플라이백 컨버터에 사용된 트랜스포머를 예로 하여 제시된 모델을 검증한다

  • PDF

Grounding Characteristics Analysis of the Stainless-steel Plate Grounding Electrode for Distribution Poles (배전전주용 스테인리스강판 접지전극의 접지 특성분석)

  • Kim, Kyung-Chul;Lee, Kyu-Jin;Kim, Min-Sung;Jung, Ji-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.94-100
    • /
    • 2010
  • Grounding system insures a reference potential point for electric devices and also provides a low impedance path for fault currents or transient currents in the earth. The ground impedance as function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. In this paper, the grounding resistance, grounding impedance and transient grounding impedance are measured by using 3-point fall-of-potential method in order to analyse grounding characteristics of the stainless-steel plate grounding electrode. An equivalent transfer function model of the grounding impedance and transient grounding impedance are identified from the measured values by using ARMA method and evaluated by comparing conventional grounding impedances.

Improvement of Connector Performance Using Analysis of Characteristic Impedance (특성임피던스 분석을 사용한 커넥터 성능향상)

  • Yang, Jeong-Kyu;Kim, Moon-Jung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.9
    • /
    • pp.47-53
    • /
    • 2011
  • The signal transmission properties of the connector such as insertion loss and return loss are investigated using analysis procedure of S-parameter simulation, equivalent model extraction, and characteristic impedance calculation. S-parameter simulation is performed by connector's modeling and solving based on 3-dimensional finite element method. The connector's equivalent model of ${\pi}$ type is are proposed and extracted with an optimization process of circuit analysis simulator. The characteristic impedance of the connector is calculated with results of circuit analysis simulation and S-parameter data. According to the connector's characteristic impedance, it's revised design is carried out. In this work, the connector's effective contact area is increased and its body is applied as a high dielectric material in order to increase its capacitance and then obtain impedance matching. Therefore, return loss of the connector is improved by approximately 10 dB due to its design revision.

Study on Detection of Broken Rail Using Impedance Measurement (임피던스 측정을 통한 레일절손 검지에 관한 연구)

  • Kim, Jae Hee;Ahn, Chi-Hyung
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.190-195
    • /
    • 2017
  • This paper proposes a method to detect rail broken through impedance measurement. In general, broken rails are detected in real time using the track circuit, but the proposed method not only detects the broken rails but also estimates positions of broken areas by measuring the rail impedance. To electrically insulate one side of the rail, parallel resonance is made by adding a capacitor; then, the impedance of the other rail is measured. If the measured impedance has an inductive value, there is no broken area of rail. However if the measured impedance has a capacitive value, the rail is broken. The proposed method is modeled using a transmission line; it is shown that the modeling can estimate the position of the broken rail according to the impedance value. The rail impedance is measured by the proposed method for a 60m simple rail model, and it is verified that the presence of a broken rail changes the rail impedance.

Self-Radiation Impedance of rectangular Acoustic Sensor Without Baffle (배플이 없는 사각형 음향센서의 자기방사 임피던스)

  • Lee, Jong-Kil;Seo, In-Chang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.82-88
    • /
    • 1995
  • Conductance and susceptance of the self-radiation impedance in a rectangular acoustic sensor without baffle are measured experimentally. Finite polyurethane window is mounted at the end of the acoustic sensor. The sensor radiation impedance is cauculated using the equivalent electric circuit. Using the Levine's integral equations of a rectangular piston mounted to the rigid infinite baffle, radiation resistance and reactance were simulated numerically. Numerical and experimental results are compared to each other.