• Title/Summary/Keyword: 임피던스특성

Search Result 1,640, Processing Time 0.031 seconds

Signal Transmission Properties Improvement of Serial Advanced Technology Attachment Connector Using Analysis of Differential Impedance (차동 임피던스 분석을 사용한 SATA 커넥터의 신호 전달 특성 개선)

  • Yang, Jeong-Kyu;Kim, Moonjung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.47-53
    • /
    • 2013
  • In this work, signal transmission properties of SATA connector have been improved using its differential impedance calculation and its design revision to closer impedance matching. Using 3 dimensional electromagnetic field simulator, the differential mode S-parameter was calculated to investigate its signal fidelity. The differential impedance is calculated from the equation of the odd mode impedance with inductance, capacitance, mutual inductance, and mutual capacitance. The differential impedance of SATA connector was calculated to be $107.3{\Omega}$ and did not meet the design specification with $100{\Omega}{\pm}5%$. In order to achieve its impedance range and improve its signal transmission properties, SATA connector's design has been revised with two different directions and analyzed through the calculation of differential impedance, differential reflection loss, and differential insertion loss.

임피던스 분석을 통한 유기태양전지의 bending에 따른 성능변화

  • Yu, Se-Gi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.258.1-258.1
    • /
    • 2015
  • ITO가 코팅된 PET 기판 위에 P3HT:PCBM으로 이루어진 bulk heterojunction 유기 태양전지 소자를 만들었다. 이렇게 만들어진 유기 태양전지의 flexibility 특성을 측정하기 위해서, 태양전지 소자를 반지름이 다른 원통에 감아서 휘어지게 한 후 AM 1.5의 조명 하에서 전류-전압 특성을 관측하고 소자의 임피던스 분석도 측정하였다. 이때 flexibility 특성 측정의 일관성을 위하여, 단 하나의 유기 태양전지 소자를 만들고, 이 소자를 반지름이 큰 원통에서 부터 휘게 하고난 후 소자의 특성을 측정하고, 점차 작은 원통으로 바꾸어 가면서 측정을 진행하였다. 임피던스 분석 실험 자료로부터 shifted two semicircles이라는 equivalent circuit model를 분석하고 난 후, 이 회로를 구성하는 구성 성분-R(s), R(low f), R(hi f), C(low f), C(hi f)-값의 변화를 원통의 반지름의 변화에 따라 분석하였다. 반지름이 0.75cm일 때, power conversion efficiency (PCE) 값은 초기값에 비해 약 1/3로 줄었고, 반지름이 0.5cm일 때는 약 10%로 줄어 들었다. 나머지 1~2 cm일 때는 거의 변화가 나타나지 않았다. 휘어짐에 따른 이러한 태양전지의 특성의 변화를 임피던스 분석의 Cole-Cole plot의 저 주파수 영역의 반원의 반지름에 가장 큰 영향을 받음을 확인하였고, 저항과 capacitance 값의 변화에 따른 특성에 대해 이번 발표에서 더 자세히 설명할 예정이다.

  • PDF

Study of Power supply noise for Blu-Ray Player Console with Touch Pad (블루레이 플레이어 Console용 Touch Pad의 전원 노이즈 해석에 관한 연구)

  • Kim, Sang-In;Kim, Jong-Min;Kim, Byung-Ki;Nah, Wan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1555_1556
    • /
    • 2009
  • 전자기기에서 외부 Console로 사용되는 Touch Pad의 입력오류를 줄이기 위해서는 안정된 전원의 공급이 필요하다, 전원에서 발생하는 노이즈는 PDN(Power Delivery Network)의 임피던스에 의해서 발생하며, 이들 노이즈를 줄이기 위해서는 decoupling capacitor의 적절한 수량과 위치를 선정하여, PDN의 임피던스를 최소화해야 한다. 본 논문에서는 임피던스의 최소화를 위해서 Full-wave 시뮬레이션을 이용해서 임피던스 특성을 분석하고, VNA(Vector Network Analyzer)를 이용하여 주파수에 대한 PDN 임피던스를 측정하고, Touch Pad 구동용 지그를 이용해서 Time Domain에서의 임피던스 저감에 따른 노이즈 특성을 분석 비교하였다.

  • PDF

Calculation of the Characteristic Impedance of Transmission Lines with Periodic Structures (주기구조가 결합된 전송선로의 특성 임피던스 계산)

  • Lim, Jong-Sik;Lee, Jae-Hoon;Lee, Jun;Han, Sang-Min;Ahn, Dal
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2541-2548
    • /
    • 2010
  • This paper describes the calculation for characteristic impedance of transmission line with periodic structures such as defected ground structure (DGS) and photonic bandgap (PBG). The previous method which uses the ${\lambda}$/4 transmission line model is reviewed and its disadvantage that the calculated characteristic impedance is strongly dependent on the frequency is discussed. The characteristic impedance of transmission lines with periodic structures are calculated using the ${\lambda}$/4 transmission line model and analytic method. The calculated characteristic impedance by the latter method is an almost constant value while that from the first method depends on the frequency strongly. In addition, the characteristic impedance of the transmission line with PBG is calculated and proposed, while it has been rarely studied ever. S-parameters are obtained from the measurement using the fabricated sample as well as simulation, and used for calculating the characteristic impedances and comparison. The characteristic impedances calculated from the measured S-parameters agree well with the simulated results. It is well described that the analytic method to calculate the characteristic impedance of transmission lines on uniform dielectric structures can be applied successfully to the transmission lines with periodic structures such as DGS and PBG.

Grounding Impedance Behaviors Associated with the Current Injection Point and the Length of Counterpoise (매설지선의 길이와 전류인가점에 따른 접지임피던스특성)

  • Li, Feng;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.66-71
    • /
    • 2009
  • This paper presents the grounding impedance behaviors of counterpoise exposed to impulse currents. The transient and conventional grounding impedances of three counterpoises having the length of 10, 30 and 50[m] were measured and analyzed as a function of the injection point of impulse currents. As a result, the trend of the conventional grounding impedances measured as a function of injection of impulse current is similar to the transient grounding impedance of counterpoise. The injection point of impulse current has great influence on the transient grounding impedance characteristics of counterpoise. The transient grounding impedance characteristics in a short time range are strongly dependent on the length of counterpoise. The transient characteristics of grounding impedance of 10[m] counterpoise subjected to the impulse current was capacitive behavior, on the other hand, those of 30[m] and 50[m] counterpoises were inductive behavior. It is found that the grounding conductor should be connected to the central point of counterpoise.

Calculation of Radiation Impedance for Piston Sources on a Spherical Baffle (구형 배플상의 피스톤 음원에 대한 방사임피던스 계산)

  • 박순종;김무준;김천덕
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.54-60
    • /
    • 2003
  • The characteristics of radiation impedance for piston source on a spherical baffle are analyzed by algorithms which consists of Finite Element Method (FEM) and Hybrid type Infinite Element Method (HIEM). The results of self-radiation impedance for radiation angle and mutual radiation impedance between piston sources coincided with other reports on the spherical rigid baffle. For the spherical non-rigid baffles, the variations of self-radiation impedance and mutual-radiation impedance are identified. Therefore, these results can be applied to design and radiation characteristics analysis of acoustic transducers.

The Characteristic Impedance and the Electric Field Uniformity of a GTEM Cell (GTEM cell의 특성 임피던스와 전계 균일도)

  • 이애경;양기곤
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.3
    • /
    • pp.523-532
    • /
    • 1994
  • A knowledge of the accurate characteristic impedance of a GTEM cell is very useful to design it. This paper discusses the characteristic impedance of a GTEM cell applicable to both susceptibility and emission measurements, considering opening angle of it. The over-RGM for analysis is described : this numerical method is operated with respect to the spherical coordinate system. Some results are compared with others and the validity of this analysis is estabished. The characteristic impedances of a GTEM cell with the variation of geometrical constructions on cross section are presented ; the effect of the opening angle on the characteristic impedance is show. Finally, the electirc field uniformities on a cross section of a GTEM cell are considered for various opening angles.

  • PDF

Damage Monitoring of PSC Girder Bridges based on Acceleration -Impedance Signals under Uncertain Temperature Conditions (불확실한 온도 조건하의 PSC 거더 교량의 가속도-임피던스기반 손상 모니터링)

  • Hong, Dong-Soo;Kim, Jeong-Tae
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.1
    • /
    • pp.107-117
    • /
    • 2011
  • In this study, the effect of temperature-induced uncertainty to damage monitoring using acceleration-impedance response features is analyzed for presterssed concrete(PSC) girder bridges. Firstly, a damage monitoring algorithm using global and local vibration features is designed. As global and local features, acceleration and electro-mechanical impedance features are selected respectively. Secondly, the temperature effect on the acceleration and impedance features for a lab-scaled PSC girder is experimentally analyzed. From the experimental results, compensation models for temperature-acceleration features and temperature-impedance features are estimated. Finally, the feasibility of the acceleration-impedance-based damage monitoring technique using the compensation model is evaluated in the PSC girder for which a set of prestress-loss and flexural stiffness loss cases were dynamically tested.

Investigation and measurement of indoor low voltage powerline impedance for high data rate powerline communications (PLC) (고속 전력선 통신용 옥내 저전압 전력선 임피던스 측정 및 특성 연구)

  • 박영진;김관호
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.8
    • /
    • pp.93-97
    • /
    • 2004
  • Since powerline for powerline communications (PLC) is designed for supplying electric power using 60 Hz wave, they will have different electrical behaviors for high data rate PLC whose bandwidth is allocated between 1 MHz and 30 MHz. Thus, it is necessary to investigate the different properties in this frequency bandwidth for the high data rate PLC. In this paper, low voltage (220V) powerline impedance for indoor high data rate PLC in between 1 MHz and 30 MHz is measured. For measurement a low voltage coupling unit is made and a vector network analyzer is used. A T-equivalent circuit of the low voltage coupling unit is obtained and then powerline impedance is derived by measuring the reflection coefficient of the total powerline network. With the method proposed, impedance is measured in case of a general korean apartment and its property is analyzed. Measurement shows that the average impedance is about 100Ω.

Analysis of Impedance Models on Flexible PCB Transmission Line (연성 PCB 전송라인을 위한 특성 임피던스 모델의 모의 분석)

  • Part, Jong-Kang;Byun, Yong-Ki;Kim, Jong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.3022-3024
    • /
    • 2005
  • 연성 PCB(flexible printed circuit board)는 현재 노트북 PC와 디지털 카메라등에 적용되며, 굴곡성이 강하고 소형화 및 조립에 용이하여 주로 기판 사이나주기판과 외부 커넥터사이에 데이터의 전송매체로써 널리 사용되는 핵심부품이다. 근래에 개발되는 PCB 기반의 고성능 신호처리회로들은 데이터 전송율이 수백 MHz에서 수 GHz에 이르고 있으며, 신호선과 유전체, 접지판의 구조적 특성에 따라서, 반사 효과와 같은 신호무결성 문제들이 파생되어 신호의 최대성능을 제한하게된다. 이에 따라 적절한 임피던스 제어를 통하여 고성능신호들의 왜곡을 상쇄시키는 기술이 중요하게 되었다. 본 논문에서는 연성 PCB 전송라인을 위한 임피던스 모델을 대상으로 각 모델의 주요 특징 및 정확성을 분석하였다. 연성 PCB의 전송라인은 보통 전통적인 마이크로스트립 라인의 특성 임피던스 모델에 비해 신호선의 너비가 크며, 이를 반영한 개선된 수학적 임피던스 모델들이 제안되어 있다. 따라서 본 논문은 기존의 마이크로스트립 전송라인과 연성 PCB 전송라인에 적합한 수학적 모델들을 이용하여 신호 무결성 문제를 모의할 수 있는 CAE(computer-aided engineering) 도구의 임피던스 측정 결과를 비교 및 분석하였다.

  • PDF