• Title/Summary/Keyword: 임플란트를 이용한 국소의치

Search Result 73, Processing Time 0.032 seconds

Full mouth rehabilitation using 3D printed crowns and implant assisted removable partial denture for a crossed occlusion: a case report (3D 프린팅 금관과 임플란트 보조 국소의치를 이용한 엇갈린 교합의 전악 수복 증례)

  • Sung-Hoon Lee;Seong-Kyun Kim;Seong-Joo Heo;Jai-Young Koak;Ji-Man Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.367-378
    • /
    • 2023
  • With the recent development of computer-aided design-computer-aided manufacturing technology and 3D printing technology, and the introduction of various digital techniques, the accuracy and efficiency of top-down definitive prosthetic restoration are increasing. In this clinical case, stable occlusion support was obtained through the placement of a total of 9 maxillary and mandibular posterior implants in patient with anterior-posterior crossed occlusion. The edentulous area of the maxillary anterior teeth, which showed a tendency of high resorption of the residual alveolar bone, was restored with a Kennedy Class IV implant assisted removable partial denture to restore soft tissue esthetics. Computed tomography guided surgery was used to place implants in the planned position, double scan technique was used to reflect the stabilized occlusion in the interim restoration stage to the definitive prostheses, and metal 3D printing was used to manufacture the coping and framework. This clinical case reports that efficient and predictable top-down full mouth rehabilitation was achieved using various digital technologies and techniques.

Valplast$^{(R)}$ flexible removable partial denture for a patient with medically compromised conditions : a clinical report (전신적 질환자 및 예후가 불량한 환자에서 Valplast$^{(R)}$ 탄성 국소의치의 적용)

  • Choi, Bohm;Kim, Seong-Hun;Lee, Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.295-300
    • /
    • 2009
  • Statement of problem: As the number of elders is growing with the advancement of medicine, partially or fully edentulous patients have increased. Medically compromised conditions are common in the older population so that it should be taken into account in prosthetic treatment planning as well as their economic conditions. In the older patients, removable prosthesis has been preferred to implant prosthesis. However, cast metal based removable partial dentures also has several limitations. Purpose: In this report, we present several cases of Valplast$^{(R)}$ flexible denture which were fabricated in patients who had medically compromised conditions or whose remaining teeth showed a relatively poor prognosis. Results & Conclusion: This article describes an alternative treatment for a partially edentulous patient with mouth opening limitation, after cancer surgery, compromised general condition and questionable remaining teeth. In these patients, Valplast$^{(R)}$ flexible denture was used because of its unique characteristics and the results were all satisfactory. Patients had 1-2 check-up and there were no postoperative pain or fracture of denture up to now.

Implant supported removable dental prosthesis with magnetic attachment in crossed occlusion: A case report (엇갈린 교합에서 implant와 magnetic attachment를 이용한 국소의치 증례)

  • Lee, Yu Jin;Lee, Richard sungbok;Lee, Suk Won;Park, Su Jung;Ahn, Su Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.53-60
    • /
    • 2017
  • When attempting to restore the oral function of a partially edentulous patient, there are a number of prosthetic treatment options available, depending on the structure of remaining teeth. For example, when only one set of maxillary and mandibular teeth are diagonally in place across from each other, it is difficult to gain stable occlusion. In this case, implants can be put in place at the corresponding edentulous area to achieve balance. By doing so, a stable occlusion can be achieved. For this case report, a patient with crossed occlusion after extraction was treated with maxillary RDP (removable dental prosthesis) and mandibular implant-supported RDP (removable dental prosthesis). Moreover, an implant fixture was placed under the posterior molar of the distal extension base diagonally across from the remaining maxillary teeth. Then, magnetic attachment was implemented. According to the patient who received the treatment, the result was functionally and aesthetically satisfactory.

Implant-supported fixed prosthesis restoration of fully edentulous patient using computer-guided implant surgery and immediate loading: A case report (Computer guided implant surgery와 immediate loading을 활용한 무치악 환자의 전악 임플란트 고정성 보철물 수복 증례)

  • Hyeon-Me Sung;Kyoung-Hee Sul;Sun-Woo Kang;Jung-Han Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.131-139
    • /
    • 2024
  • In a edentulous patient, various methods can be employed for prosthetic treatment using implants, such as implant-supported fixed prostheses, overdentures, hybrid prostheses, and implant assisted removable partial denture. In this case, in a patient with moderate to severe chronic periodontitis requiring full arch extractions, implants were strategically placed using computer-guided surgery. In the maxilla, due to inadequate bone quality and quantity leading to insufficient initial stability, delayed loading was implemented, and interim prosthesis was used during the osseointegration period. In the mandible, stable initial stability was achieved, allowing for immediate loading to reduce patient discomfort. Primary stability is considered the most crucial factor for obtaining immediate loading, so a thorough clinical and radiological evaluation of the remaining alveolar bone quantity and quality must be conducted before surgery.

Implant supported fixed prosthesis for complete edentulous maxilla with severe alveolar ridge resorption: A case report (치조골 흡수가 심한 상악 완전 무치악 환자에서 임플란트 고정성 보철물을 이용한 수복 증례)

  • Choi, Yoon-Ji;Lee, Ji-Hyoun;Jhin, Min-Ju
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.152-159
    • /
    • 2016
  • Implant fixed prosthesis for the complete edentulous maxilla provides significant benefits in the aspects of functions and esthetics compared with the conventional denture. Implant supported fixed prosthesis are totally supported by implant, and thus stabilizes the prosthesis to the maximum degree as possible. Also, the improved retention and stability of fixed prosthesis enhance patients' psychological and psychosocial health. This clinical presentation describes a maxillary full arch implant-supported fixed prosthesis in complete maxillary edentulous patient who showed vertical and horizontal alveolar bone resorption in the anterior ridge. To rehabilitate the esthetics and proper lip support, the zirconia framework was fabricated and the pink porcelain was veneered to reproduce the natural gingival tissue. After 9 months of follow up, the restorations were maintained without complications and the patient was satisfied with the restoration both functionally and esthetically.

Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report (구순구개열 환자에서 Locator® 유지장치가 장착된 milled titanium bar를 이용한 가철성 임플란트 피개 국소의치의 보철수복증례)

  • Yang, Sang-Hyun;Kim, Kyoung-A;Kim, Ja-Yeong;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.207-214
    • /
    • 2015
  • Due to the limitations of conventional removable partial denture prostheses to treat a cleft lip & palate patient who shows scar tissue on upper lip, excessive absorption of the maxillary residual alveolar ridge, and class III malocclusion with narrow palate and undergrowth of the maxilla, 4 implants were placed on the maxillary edentulous region and a maxillary removable implant-supported partial denture was planned using a CAD/CAM milled titanium bar. Unlike metal or gold casting technique which has shrinkage after the molding, CAD/CAM milled titanium bar is highly-precise, economical and lightweight. In practice, however, it is very hard to obtain accurate friction-fit from the milled bar and reduction in retention can occur due to repetitive insertion and removal of the denture. Various auxiliary retention systems (e.g. $ERA^{(R)}$, $CEKA^{(R)}$, magnetics, $Locator^{(R)}$ attachment), in order to deal with these problems, can be used to obtain additional retention, cost-effectiveness and ease of replacement. Out of diverse auxiliary attachments, $Locator^{(R)}$ has characteristics that are dual retentive, minimal in vertical height and convenient of attachment replacement. Drill and tapping method is simple and the replacement of the metal female part of $Locator^{(R)}$ attachment is convenient. In this case, the $Locator^{(R)}$ attachment is connected to the milled titanium bar fabricated by CAD/CAM, using the drill and tapping technique. Afterward, screw holes were formed and 3 $Locator^{(R)}$ attachments were secured with 20 Ncm holding force for additional retention. Following this procedure, satisfactory results were obtained in terms of aesthetic facial form, masticatory function and denture retention, and I hereby report this case.

Prosthetic rehabilitation with digital implant planning for a minimally invasive surgery approach (디지털 임플란트 플래닝을 통한 최소침습 보철수복 증례)

  • Jeong, Areum;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.3
    • /
    • pp.283-292
    • /
    • 2022
  • For fixed prosthetic treatment using implants, implants must be placed in a suitable location for prosthetic treatment. During surgery, minimally invasive prosthetic restoration is possible using a flapless method using a surgical guide. The patient in this case was an 86-year-old male patient who wanted treatment due to discomfort when using conventional dentures. Due to systemic disease, the patient had difficulty using removable local dentures, so full dentures for the maxilla and fixed implants for the mandible were restored. Because there is a high risk of bleeding due to systemic disease, the implant was placed in a flapless method using a surgical guide. Finally, prostheses were fabricated with maxillary full denture and mandibular screw-retained zirconia, and this report shows satisfactory esthetic and functional recovery.

An Esthetic Restoration of the Missing Maxillary Anterior Teeth with the Rotational Path RPD: A Case Report (회전삽입로 국소의치를 이용한 심미적 상악 전치부 수복 증례)

  • Lee, Ji-Hye;Lim, So-Min;Jung, Hye-Eun;Park, Chan-Jin;Cho, Lee-Ra;Kim, Dae-Gon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.209-222
    • /
    • 2011
  • Missing anterior teeth can be replaced using any of a number of methods. Patients may choose to replace missing teeth with a prosthesis that is either removable, fixed, or retained with implants. For patients faced with financial, anatomical, and/or esthetic limitations, the edentulous region can be restored successfully and esthetically with a properly designed and fabricated rotational path RPD. The rotational path RPD is a partial removable dental prosthesis that incorporates a curved, arcuate, or variable path of placement allowing one or more of the rigid components of the framework to gain access to and engage an undercut area. The rigid retainer must gain access to the infrabulge portion of the tooth by rotating into place. Either a minor connector or proximal plate provides retention through its intimate contact with a proximal tooth surface. A specially designed dovetails or asymmetric rest seats provides support and embracing effects. Correctly designed and fabricated rotational path RPD can provide improved esthetics, cleanliness, and retention. But rotational path RPDs are technique sensitive since the rotational path RPD has little margin of laboratory error that rigid retainers cannot be adjusted like conventional clasps can, RPD framework must be remade once the retention is lost. The sufficient understanding of the concept for the rotational path RPD is required for clinically successful treatment. This clinical report describes in detail the theoretical, laboratory considerations and the treatment of a patient with an anterior maxillary edentulous area treated by an AP path rotational RPD that had a difficulty in long term maintenance and describes another clinical case in which more reasonable treatment procedures were approached after analyzing the former case.

Full mouth rehabilitation of the patient with crossed occlusion using removable partial denture restoration: A case report (엇갈린 교합 환자에서의 가철성 보철을 이용한 전악구강회복 증례)

  • Choi, Yu-Ra;Kang, Jeong-Kyung;Kim, Na-Hong;Chang, Hee-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.38-45
    • /
    • 2017
  • In removable partial denture with crossed occlusion, it is difficult to meet the satisfaction of patient due to variable movement of denture and unfavorable stability under loading. In a case with few unilaterally teeth remaining, additional treatments such as implantation or residual root are required to assure bilaterally stable support. However, due to the medical condition of the patient with hypertension, angina and old age etc., removable partial denture was planned as treatment in this case. Proper diagnosis, accurate analysis and full understanding of the adaptation for neuromuscular system are necessary to recover the vertical dimension of patient from a decreased vertical dimension due to crossed occlusion.

Full-mouth rehabilitation with pressed ceramic technique using provisional restorations (Pressed ceramic technique을 이용하여 제작되는 완전 도재관 완전 구강 회복 증례)

  • Roh, Hyun-Sik;Woo, Yi-Hyung;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.47-51
    • /
    • 2013
  • With the introduction of dental implants, restoration of missing teeth with conventional fixed or removable partial dentures is being replaced with implants. Especially, with young patients, not only longevity but also esthetic factors need to be considered. Implant restorations provide long-term success functionally but, esthetic complications such as, marginal exposure due to gingival recession, loss of the papilla and dark color of metal abutments may occur. Recently, zirconia restorations with CAD/CAM technology provide functional, biocompatible and esthetic restorations possible. All-ceramic restorations using the pressed ceramic technique show better fracture toughness values than those of the conventional porcelain veneering technique. Pressed ceramic technique creates the veneer design in wax and the lost wax technique is used to create the restoration. The final contour of the restoration may be controlled during wax-up. A 22-year old female patient was restored with dental implants and zirconia restorations using the pressed ceramic technique presenting short-term but optimistic prognosis.