• Title/Summary/Keyword: 임시충전재

Search Result 5, Processing Time 0.025 seconds

An Experimental Study on Microleakage in Light-activated Temporary Filling Materials (광중합형 임시충전재의 미세누출에 관한 실험연구)

  • Hwang, Su-Hyun;Yu, Ji-Su;Kim, Sun-Ju
    • Journal of dental hygiene science
    • /
    • v.11 no.4
    • /
    • pp.333-337
    • /
    • 2011
  • The purpose of this experiment was to examine possibility of microleakage by water, temperature change, and bite force inside the mouth during the period of using light-activated temporary filling materials. 2 kinds of light-activated temporary filling materials were used in order to measure weight and compressive strength and to evaluate microleakage between filling material and cavity wall according to frequency of thermal circulation. First, Light-activated temporary filling material was increased the weight, which was measured according to the period of using. As for the result of comparing between products, the weight of Quicks was indicated to be higher. Second, Compressive strength of Spacer had significant difference depending on period of using. However, significant difference wasn't shown in the compressive strength of Quicks. In Spacer that showed significant difference, the compressive strength increased greatly in the difference of 3 days. Third. As for micro-leakage according to frequency of thermal circulation, the microleakage was indicated to be the highest in the group that carried out 7,000 times. The group with operation of 1,000 times and the group with operation of 3,000 times were indicated the statistically lower micro-leakage than the group with operation of 7,000 times. This study brought about a rise in micro-leakage depending on the passage in the period of using. However, it is obvious fact that micro-leakage increases according to the passage of time after restoration.

Microleakage of Endodontic Temporary Restorative Materials under Dynamic Loading (동적하중 하에서 근관치료용 임시충전재의 미세누출의 평가)

  • Jung, Dong-Ho;Noh, Young-Sin;Lee, Hae-Doo;Chang, Hoon-Sang;Ryu, Hyun-Wook;Min, Kyung-San
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.198-203
    • /
    • 2008
  • The purpose of this study was to compare the sealing abilities of four endodontic temporary restorative materials using a methylene blue dye penetration test under dynamic loading. Standardized access cavities were prepared in forty-four intact human permanent molar teeth, and the cavities were restored with Caviton, MD-Temp, IRM, or ZOE. After thermocycling, an intermittent load of 98 N at 1 Hz was applied for 1,000 cycles to the long axis of the functional cusp of each of the teeth, which were immersed in a 1% methylene blue solution. The teeth were split in half, and the linear depth of dye penetration was evaluated according to the criteria. The results were analyzed using one-way ANOVA (p = 0.05) and Duncan's multiple range test. The results demonstrated that Caviton and MD-Temp showed significantly lower microleakage than IRM and ZOE. It was concluded that Caviton and MD-Temp exhibited better sealing ability than IRM and ZOE under dynamic loading.

  • PDF

Microleakage of Endodontic Temporary Restorative Materials under Dynamic Loading (동적하중 하에서 근관치료용 임시충전재의 미세누출의 평가)

  • Jung, Dong-Ho;Noh, Young-Sin;Lee, Hae-Doo;Chang, Hoon-Sang;Ryu, Hyun-Wook;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.198-203
    • /
    • 2008
  • The purpose of this study was to compare the sealing abilities of four endodontic temporary restorative materials using a methylene blue dye penetration test under dynamic loading. Standardized access cavities were prepared in forty-four intact human permanent molar teeth, and the cavities were restored with Caviton, MD-Temp, IRM, or ZOE. After thermocycling, an intermittent load of 98 N at 1 Hz was applied for 1,000 cycles to the long axis of the functional cusp of each of the teeth, which were immersed in a 1% methylene blue solution. The teeth were split in half, and the linear depth of dye penetration was evaluated according to the criteria. The results were analyzed using one-way ANOVA (p = 0.05) and Duncan's multiple range test. The results demonstrated that Caviton and MD-Temp showed significantly lower microleakage than IRM and ZOE. It was concluded that Caviton and MD-Temp exhibited better sealing ability than IRM and ZOE under dynamic loading.

POLYMERIZATION SHRINKAGE, HYGROSCOPIC EXPANSION AND MICROLEAKAGE OF RESIN-BASED TEMPORARY FILLING MATERIALS (레진계 임시수복재의 중합수축, 수화팽창과 미세누출)

  • Cho, Nak-Yeon;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.115-124
    • /
    • 2008
  • The purpose of this study was to measure the polymerization shrinkage and hygroscopic expansion of resin-based temporary filling materials and to evaluate microleakage at the interface between the materials and cavity wall. Five resin-based temporary filing materials were investigated: Fermit (Vivadent), Quicks (Dentkist), Provifil (Promedica), Spacer (Vericom), Clip (Voco). Caviton (GC) was also included for comparison. Polymerization shrinkage of five resin-based temporary filling materials was measured using the bonded disc method. For the measurement of hygroscopic expansion, the discs of six cured temporary filling materials were immersed in saline and a LVDT displacement sensor was used to measure the expansion for 7 days. For estimating of microleakage, Class I cavities were prepared on 120 extracted human molars and randomly assigned to 6 groups of 20 each. The cavities in each group were filled with six temporary filling materials. All specimens were submitted to 1000 thermocycles, with temperature varying from $5^{\circ}C/55^{\circ}C$. Microleakage was determined using a dye penetration test. The results were as follows: 1. Fermit had significantly less polymerization shrinkage than the other resin-based temporary fill ing materials. Fermit (0.22%) < Spacer (0.38%) < Quicks (0.64%), Provifil (0.67%), Clip (0.67%) 2. Resin-based temporary filling materials showed 0.43-1.1% expansion in 7 days. 3. Fermit showed the greatest leakage, while Quicks exhibited the least leakage. 4. There are no correlation between polymerization shrinkage or hygroscopic expansion and microleakage of resin-based temporary filling materials.

A STUDY ON THE SEALING PROPERTIES OF TEMPORARY FILLING MATERIALS USED IN ENDODONTICS (근관치료시 사용되는 수종 임시충전재의 변연 폐쇄효과에 관한 연구)

  • Yoo, Hyun-Mee;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.33-42
    • /
    • 1991
  • The purpose of this study was to evaluate the sealing properties of the temporary filling materials used in endodontic treatment Access cavities were prepared in 135 extracted human molar teeth. Then, cotton pellets were placed in the pulp chamber until the depth of 5 mm for the temporary filling materials; Caviton, zine oxide-eugenol, double sealing (A) (stopping 15 mm + zinc oxide - eugenol, 3.5mm ) double sealing (B) (stopping 3.0 mm + zinc oxide - eugenol 2.0 mm) and gutta percha stopping. After filling the materials, the teeth were immersed in 1 % methylene blue solutions for 3 days, 1 week and 2 weeks. Then thermal cycling was performed at the temperature of $60^{\circ}C$ and $4^{\circ}C$, followed by longitudinal sections on the center of tooth. Finally, staining on the cotton pellet was evaluated. The following results were obtained. 1. Stopping showed lower marginal sealing quality than Caviton, zinc oxide - eugenol and double sealing. 2. In 1 week group, Caviton showed higher marginal sealing quality than zinc oxide-eugenol, double sealing and stopping. 3. Caviton and double sealing (B) showed a great decrease in marginal sealing quality with the increse of time. 4. Caviton had high marginal sealing quality in 3 day group and 1 week group, but in 2 week group, Caviton showed a great decrease. 5. Double sealing (B) showed fairly high marginal sealing quality in 3 day group, but decreased greatly after 1 week on.

  • PDF