• Title/Summary/Keyword: 임계 충격에너지

Search Result 14, Processing Time 0.028 seconds

An analysis of the Reacture Inutuation of falling type Impact Test for toughened Rigid Plastics (인성의 강소성 플라스틱 재료에 대한 낙하충격 시험의 파괴개시에 관한 연구)

  • 김진우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.4
    • /
    • pp.385-393
    • /
    • 1984
  • 본 연구에서는 다트식 낙하충격 시험에 있어서 인성의 강소성 플라스틱 재료 의 준정적 선형의 점탄성 모델이 구성되어 해석되었다. 완화계수함수, E(t)=E$_{f}$ +(E$_{o}$ -E$_{f}$ )e$^{-t/tR}$ 형태의 점탄성 재료의 수정된 Maxwell요소모델을 근거 로 충격속도, 파괴에너지, 임계응력등의 중요변수들의 상대적 종속성이 근사계산으로 평가되었다.

A Study on the Impact Fracture Behavior of Carbon Fiber Reinforced Plastics (CFRP 복합재료의 충격파괴거동에 관한 연구)

  • 고성위;김학돌;엄윤성;최영근;김형진;김재동;김엄기
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.4
    • /
    • pp.300-306
    • /
    • 2002
  • In this paper the failure mechanisms and Charpy impact tests of carbon fiber polypropylene composites have been studied in the temperature range -5$0^{\circ}C$ to 6$0^{\circ}C$ and 3 different supported length of specimen (span length). There are significant effects of temperature and span length on impact fracture toughness, which shows a peak at ambient temperature and decrease as temperature is reduced. Fracture toughness shows a maximum at span length s=20mm. Failure mechanisms are characterized based on SEM examination, which is correlated the measured fracture toughness. Mafor mechansms of this composites can be classified as fiber matrix debonding, delamination, fiber pull-out and matrix deformation.

Control of High-Pressure Exhaust Gas Flows Using Shock-Wave Confinement (충격파 감금법을 이용한 고압배기가스 유동의 제어)

  • ;;K.Matsuo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.19-19
    • /
    • 1998
  • 최근 화학, 연소, 동력, 제철 등의 각종 플랜트에서 조업압력이 고압화되어 가고 있으며, 이에 수반하여 배관계를 통하는 고압가스 유동에 관한 연구가 활발하게 진행되고 있다. 배관계를 통하는 고압가스의 유동에 있어서 유량의 적절한 제어, 유동에 의하여 야기되는 배관계의 소음·진동, 그리고 배기가스의 적절한 처리법 등은 공학적으로 매우 중요한 문제로 알려져 왔다. 일반적으로 정상운전을 하는 플랜트에서 고압 배기가스의 문제는 배기가스 Expander에 의하여 에너지를 회수하는 방법이 생각될 수 있으나, 실제 공업현장에서는 배기가스를 안전하고, 또 소음·진동을 발생시키지 않도록 적절하게 처리하는 것이 매우 중요한 기술적 과제로 남아 있다. 일반적으로 배기가스의 압력이 임계압력(critical pressure) 이상으로 되는 경우(실제 대부분의 플랜트에서 배기가스의 압력은 임계압력보다 매우 높다), 배관계 내부에서 충격파(shock-wave)가 발생하여 난류와동 혹은 난류경계층과 간섭하게 됨으로써 강력한 공기역학적 소음이나 진동을 발생시키게 된다. 이와 같은 소음·진동에 대한 대책으로는 현재 가스배출부에 감압밸브를 직렬로 설치하거나, 유로에 다공판(porous plates)들을 삽입하여 감압과정을 공간적으로 분산시킴으로써, 충격파가 발생하지 않도록 하는 방법을 주로 채택하고 있다. 그러나 이러한 방법을 적용하는 경우 배기가스 유동에 대한 유량의 제어기능이 저하되는 문제가 발생한다.

  • PDF

A Study on Shock-induced Detonation in Gap Test (충격 전달에 의한 Gap Test의 폭굉 반응 해석)

  • Kim, Bohoon;Kang, Wonkyu;Jang, Seung-gyo;Park, Jungsu;Yoh, Jai-ick
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.2
    • /
    • pp.75-85
    • /
    • 2016
  • A pyrotechnic system consisting of donor/acceptor pair separated by a gap relies on shock attenuation characteristics of the gap material and shock sensitivity of the donor and acceptor charges. Despite of its common use, numerical study of such pyrotechnic train configuration is seldom reported because proper modeling of the full process requires precise capturing of the shock wave attenuation in the gap prior to triggering a full detonation of high explosive and accurate description of the high strain rate dynamics of the explosively loaded inert confinements. We apply a Eulerian level-set based multimaterial hydrocode with reactive flow models for pentolite donor and heavily aluminized RDX as acceptor charge. The complex shock interaction, critical gap thickness, acoustic impedance, and go/no-go characteristics of the gap test are quantitatively investigated.

A Study on the Impact Damage and Residual Strength of CFRP Composite Laminates under Low Temperature (저온하에서 CFRP 적층재의 충격 손상과 잔류 강도 -저/고온하에서 CFRP 적층재의 충격 손상을 중심으로 -)

  • Yang, I.Y.;Jung, J.A.;Cha, C.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.17 no.1
    • /
    • pp.1-10
    • /
    • 1997
  • In this paper, the effects of temperature change (low and high temperature) on the impact damages of CFRP laminates was experimentally studied. Composite laminates used for this experiment are CF/epoxy orthotropic laminated plates, which have two-interfaces $[0^{\circ}\;_6/90^{\circ}\;_6]s$ and $[0^{\circ}\;_4/90^{\circ}\;_4]s$. And CF/PEEK orthotropic laminated plates, which have two-interfaces $[0^{\circ}\;_4/90^{\circ}\;_4]s$. And, this study aims experimentally to present the interrelations between the impact energy vs. impact damages (i.e. delamination area and matrix crack) of CFRP laminates (CF/epoxy, CF/PEEK) subjected to FOD(foreign object damage) under low and high temperatures. A steel ball launched by the air gun collides against CFRP laminates to generate impact damages.

  • PDF

Damage Behaviors by Particle Impact Energy of $Al_2O_3-TiO_2$ Coated Glass Specimen ($Al_2O_3-TiO_2$ 용사코팅된 유리의 입자충격 에너지에 따른 손상거동)

  • Lee, Moon-Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.6
    • /
    • pp.107-114
    • /
    • 2012
  • Fracture of brittle material due to dynamic load such a particle impact has been reported by many researchers as the fracture behavior by variation of stress for a short minute. Especially, the brittle material, such a ceramic, applied to the structural component of machine, is considered as the important project. In order to evaluate the improvement of impact resistance, the particle impact test for the $Al_2O_3-TiO_2$ coated glass is practiced. And then, the damage variation according to the impact energy of steel ball was evaluated. There was a large improvement by the ceramic coating on the surface of a glass substrate. The damage volume was especially imported to evaluate damage behavior in quantity. These data were plotted on logarithmic coordinate and experimental equations were induced by data analysis based on test results. And the variation of critical energy for crack initiation was analyzed with critical impact energy when each crack occurs.

Temperature Effect on Impact Fracture Behavior of GF/PP Composites (GF/PP 복합재료의 충격파괴거동에 대한 온도효과)

  • Koh, Sung-Wi;Um, Yoon-Sung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.41 no.1
    • /
    • pp.78-84
    • /
    • 2005
  • The main goal of this work is to study the effects of temperature and volume fraction of fiber on the Charpy impact test with GF/PP composites. The critical fracture energy and failure mechanisms of GF/PP composites are investigated in the temperature range of 60^{\circ}C$ to -50^{\circ}C$ by impact test. The critical fracture energy increased as the fiber volume fraction ratio increased. The critical fracture energy shows a maximum at ambient temperature and it tends to decreases as temperature goes up or goes down. Major failure mechanisms can be classified such as fiber matrix debonding, fiber pull-out and/or delamination and matrix deformation.

Studies on the Precipitation Behavior of Boron in the TMCP-HSLA Steels (고강도 저합금의 TMCP강에서의 B의 석출거동에 관한 연구)

  • Park, Woong;Lee, Chongmu
    • Korean Journal of Materials Research
    • /
    • v.8 no.4
    • /
    • pp.304-311
    • /
    • 1998
  • 0.07%C-0.014%Ti-0.015Nb-0.005%B강 (강종 B)을 각각 TMCP처리하여 그 기계적 특성과 B의 거동을 조사하였다. Ta-B강이 Ti-Nb-B강보다 인장강도는 더 우수하였으나 충격 흡수에너지는 훨씬 더 낮았다. Ta-B강의 강도가 Ti-Nb-B강보다 더 우수한 이유는 Ta-B강에서의 Ta의 석출강화 효과가 Ti-Nb-B강에서의 Ti와 Nb의 석출강화 효과보다 더 크기 때문으로 생각된다. Ta-B강은 입내파괴, Ti-Nb-B강은 임계파괴의 파괴양상을 보여이며, Ti-Nb-B강이 Ta-B 강보다 더 큰 충격 흡수에너지를 나타내었다. TMCP에서는 항온변태시의 평형석출과는 달리 연속냉각방법을 사용하였기 때문에 B가 결정립계에 평형적 또는 비평형적으로 편석되어 준안정상으로 생각되는 연속적인 필름 형태의 붕화물을 형성한다. 또한, 냉각속도의 차이에 따라 석출물은 결정질이 되거자 비정질이 되었다. B의 함량이 많은 Ti-Nb-B강에서는 석출물이 비정질상이었다. 한편, B함량이 적은 Ta-B강에서는 B강에서는 결정립계에서 B가 관찰되지 않아는데, 이것은 결정립계에서의 B의 석출이 B의 함량에 매우 민감함을 의미하는 것이다.

  • PDF

Effect of Surface Free Energies on Mechanical Properties of Epoxy/Polyurethane Blend System (에폭시/폴리우레탄 블렌드 시스템의 표면 자유에너지 변화가 기계적 특성에 미치는 영향)

  • 박수진;진중성;이재락;박병기
    • Polymer(Korea)
    • /
    • v.24 no.2
    • /
    • pp.245-251
    • /
    • 2000
  • A blend system prepared from epoxy(EP) and polyurethane (PU) was investigated in terms of the contact angle and mechanical properties. The contents of EP/PU were varied within 100/0~100/60 phr in the presence of 20 phr DDM (4,4'-diamino diphenyl methane) as a curing agent for epoxy resin. Contact angle measurements were performed employing a Rame-Hart contact angle goniometer. Deionized water and diiodomethane were chosen as the testing liquids. In this work, Owens-Wendt and Wu's models using a geometric mean were studied to analyze the surface free energy of blend system. For the mechanical and toughening properties of the casting specimens, the critical stress Intensity factor ($K_{IC}$) and impact test were performed. Especially, the impact test was carried out at room and cryogenic temperatures. As a result, specific or polar component of the surface free energy of the blend system was largely influenced on the addition of the PU resulting in increasing the impact strength for the excellent low- temperature performance.

  • PDF

Temperature Effects on Impact Fracture Mechanisms of Glass Fiber/Polypropylene Campsites (유리섬유/폴리프로필렌 복합재료의 충격파괴기구에 대한 온도효과)

  • KOH S. W.;Um Y. S.
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.314-319
    • /
    • 2004
  • Many of researches regarding mechanical properties of composite materials are associated with humid environment and temperature. Especially the temperature is a very important factor influencing the design of thermoplastic composites. However, the effect of temperature on impact behavior of reinforced composites have not yet been fully explored. An approach which predicts critical fracture toughness GIC was performed by the impact test in this work The main goal of this work is to study effects of temperature in the impact test with glass fiber/polypropylene(GF/pp) composites. The critical fracture energy and failure mechanisms of GF/PP composites are investigated in the temperature range of $60^{\circ}C\;to\;-50^{\circ}C$ by impact test. The critical fracture energy shows a maximum at ambient temperature and it tends to decrease as temperature goes up or goes down. Major failure mechanisms can be classified such as fiber matrix debonding, fiber pull-out and/or delamination and matrix deformation.

  • PDF