• Title/Summary/Keyword: 임계온도

Search Result 561, Processing Time 0.027 seconds

Post-Fire Damage and Structural Performance Assessment of a Steel-Concrete Composite Bridge Superstructure Using Fluid-Structure Interaction Fire Analysis (FSI 화재해석을 이용한 강합성 교량 상부구조의 화재 후 손상 및 구조성능 평가)

  • Yun, Sung-Hwan;Gil, Heungbae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.627-635
    • /
    • 2021
  • The fire damage and structural performance of a steel-concrete composite superstructure under a highway bridge exposed to fire loading was evaluated. To enhance the accuracy and efficiency of the numerical analysis, a proposed fluid-structure interaction fire analysis method was implemented in Ansys Fluent and Ansys Mechanical. The temperature distribution and performance evaluation of the steel-concrete composite superstructure according to the vertical distance from the fire source to the bottom flange were evaluated using the proposed analysis method. From the analysis, the temperature of the concrete slab and the bottom flange of the steel-concrete composite superstructure exceeded the critical temperature. Also, when the vertical distance from the fire source was 13 m or greater, the fire damage of the steel-concrete composite superstructure was found to within a safe limit.

Study of heat transfer to the implant-bone interface induced by grinding of occlusal surface of implant gold prosthesis (금 합금 보철물의 교합면 삭제로 인한 임플란트-골 계면으로의 열전달에 관한 연구)

  • Jo, Jae-Young;Kang, Sun-Nyo;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Purpose: The purpose of this study was to analyze temperature change along the implant-bone interface induced by grinding the occlusal surface of implant gold prosthesis and to compare the temperature generated by grinding of prosthesis with different cooling methods. Materials and methods: The experimental gold prostheses were fabricated with dental gold alloy and castable abutment. The prostheses had 3 cylindrical protrusions on the occlusal surface with 1mm in height. Temperature was measured using 16 thermocouple wires attached to the implant fixture surface and the fixture was embedded in an acrylic resin block inside the $37^{\circ}C$ water bath. Cylinders were grinded for a period of 30 second with a low-speed handpiece with green stone point. One cylindrical protrusion was grinded without cooling, the second one was grinded with air blow, and the third one was grinded with water-spray. Results: The mean maximum temperature was measured more than $47^{\circ}C$ of the implant and the maximum temperature was measured at the cervical portion of the implant in the group without cooling. There was statistically significant difference between the group without cooling and the groups with cooling (P<.05). However, there was no significant difference at all portion of implant in the groups with cooling (P>.05). Conclusion: The results of this study support that the grinding of implant gold prosthesis without cooling may damage the peri-implant tissue. The continuous use of air blow and water-spray adjacent to prosthesis during the grinding of implant gold prosthesis may prove to be beneficial for cooling of the implant.

An Analysis of the Figure of Merit depending on the cut-off size of a Small Reflector for Satellite Broadcast Receiving Antenna (위성방송 수신용 소형 반사면 안테나의 절단 크기에 따른 성능지수의 분석)

  • Lim, Gye-jae
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.6 no.3
    • /
    • pp.152-155
    • /
    • 2013
  • In this paper, the reduction of the figure of merit depending on the increased spill-over when the parabolic reflector is cut off partially for low-profile configuration in the satellite broadcast receiving antenna is analyzed. Also for the accurate analysis and simulation, it is considered that the noise temperature is increased due to the effect of ground thermal noise toword the sidelobes and back lobes when the antenna is tracked from $0^{\circ}$ to $60^{\circ}$ in elevation angle, and that the total noise temperature is increased because to the noise figure of LNA. As the results, noise temperature is increased up to about 15K and G/T ratio is decreased to about 2.5dB, when the reflector is cut 35% off partially.

The prediction of crystalline formation in high-ash fusion temperature coal slags mixed CaO flux (Flux가 첨가된 고용융 석탄슬래그에서의 결정체 형성 예측)

  • Kim, Yu-Na;Ju, Hyun-Ju;Oh, Myong-Sook
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.848-851
    • /
    • 2009
  • 석탄슬래그는 회분의 조성에 따라 고온에서 매우 상이한 슬래그 거동을 보여준다. 국내 가스화 대상탄으로 검토된 탄 중, 산성 산화물의 함량이 높아 고용융점을 갖는 7종의 석탄 회분을 가스화 조건인 고온, 환원분위기에서 점도 측정을 실시하였다. 4종의 탄에 대해서는 높은 점도를 낮추기 위하여 염기성 산화물인 CaO를 3가지 비율로 혼합하여 점도 측정을 실시하였다. 또한, flux의 혼합으로 인해 발생할 수 있는 결정체 형성을 FactSage 평형계산 프로그램과 CaO-SiO2-Al2O3 3성분계 상평형도를 이용하여 예측하였다. CaO가 첨가된 시료 모두에서 낮은 CaO 첨가비에서는 원래의 시료보다 낮은 점도를 보였으나, CaO첨가비가 20% 이상일 때는 anorthite이 형성되어 $T_{cv}$를 갖는 결정슬래그로 점도 거동이 변화하면서 실제조업 가능한 온도를 증가시켰다. 점도 측정 후 냉각된 시료의 SEM/EDX 분석을 통해 형성된 결정체를 관찰한 결과, FactSage와 상평형도에서 예측된 결정체와 유사하게 나타나 CaO-SiO2-Al2O3 3성분계 상평형도가 결정체 예측에 유용함을 확인하였다.

  • PDF

A Study on the Local Buckling of H-Beams at Elevated Temperatures (온도상승(溫度上昇)에 따른 H-형강(形鋼)보의 국부좌굴(局部挫屈)에 관(關)한 연구(硏究))

  • Koo, Bon Youl;Kang, Moon Myung;Kang, Sung-Duk
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.1 s.68
    • /
    • pp.103-111
    • /
    • 2004
  • This paper dealt with the local buckling of H-beams investigated mainly using the parameters of load ratios. load conditions, and support boundary condition considering predicted uniformly elevated temperatures. The physical properties of the material at elevated temperatures followed EC3 Park 1.2. The local buckling of the plates in steel beams show that they are governed by the yield stress or the critical stress of the steel plates according to the ratios of b/tf, d/tw. The evaluation of uniformly heated steel beams on the local buckling considered the stress and moment ratios to the LRFD.

Optical power stabilization of a laser diode by constant voltage (정전압 구동에 의한 레이저 다이오드의 광출력 안정화)

  • 이성호
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.2
    • /
    • pp.116-121
    • /
    • 1997
  • The optical power drift due to temperature variation of a laser diode driven by constant voltage is different from one driven by constant current. When a laser diode is driven by constant current, the optical output decreases as the temperature increases because the population inversion decreases. However, When it is driven by constant voltage, injection current increases with temperature rise, which in turn increases the optical power. As the result, the optical power variation reduces. Experimental results show that when these two components are almost equal and cancel each other, the optical power variation coefficient is very small and the optical output is stable.

  • PDF

Dislocation Behavior around Crack Tips in Single Crystal Alumina (단결정 알루미나의 균열첨단에서 전위거동)

  • Kim, Hyeong-Sun;Robers, S.G
    • Korean Journal of Materials Research
    • /
    • v.4 no.5
    • /
    • pp.590-599
    • /
    • 1994
  • A work on the brittle to ductile transition (BDT) in single crystal alumina has been performed to understand and assess the dynamics of dislocation mobility around crack tip of brittle material. The critical stress intensity factor and yield strengths were obtained from bending test using precracked specimens at elevated temperatures. It was found that the BDT temperature was dependent on strain rate and orientation of specimen : for (1120) fracture surface, $1034^{\circ}C$, $1150^{\circ}C$ for $4.2 \times 10^{-6}$, $4.2 \times 10^{-7}s^{-1}$ respectively. Under a 4 point bending test, the moving distance of dislocation generated near crack front in ductile range is determined by an etch pits method. The velocity of dislocation in sapphire obtained from the double etching method was applied to modelling study.

  • PDF

Simulations of Proposed Shallow Trench Isolation using TCAD Tool (TCAD 툴을 이용한 제안된 얕은 트랜치 격리의 시뮬레이션)

  • Lee, YongJae
    • Journal of the Korea Society for Simulation
    • /
    • v.22 no.4
    • /
    • pp.93-98
    • /
    • 2013
  • In this paper, the proposed shallow trench isolation structures for high threshold voltage for very large scale and ultra high voltage integrated circuits MOSFET were simulated. Physically based models of hot-carrier stress and dielectric enhanced field of thermal damage have been incorporated into a TCAD tool with the aim of investigating the electrical degradation in integrated devices over an extended range of stress biases and ambient temperatures. As a simulation results, shallow trench structure were intended to be electric functions of passive, as device dimensions shrink, the electrical characteristics influence of proposed STI structures on the transistor applications become stronger the potential difference electric field and saturation threshold voltage.

Magnetic $T_c$ Measurements of Composite Superconductors for a Standard Method (복합초전도체의 자기적 임계온도 측정의 표준화연구)

  • Lee K. W;Kim M. S;Kim D. H;Lee S. G
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.24-31
    • /
    • 2004
  • Magnetic $T_{c}$ of composite superconductors has been studied for providing a standard method. Various magnetization-temperature curves of NbTi, $Nb_3$Sn and Bi-2223 wires were measured using a SQUID magnetometer. Magnetization-temperature curve of zero-field-cooled procedure showed larger values than fie Id-cooled procedure. To obtain higher resolution near the onset temperature, we employed a two-field-direction method which measures a magnetization-temperature curve of a specimen first in positive and then negative fields. Analytical comparison of the magnetic $T_{c}$, with the resistive T$_{c}$ was accomplished for three specimens. The magnetic $T_{c}$/ mettled showed more detailed information on superconducting state of a specimen than the resistive$T_{c}$/ method. We have also studied the field dependence of the magnetic $T_{c}$ from 5 Oe to 120 Oe, however, no significant difference on field strength was found in our three specimensns

  • PDF

A Stable Threshold Linear Current Pulse Discriminator (안정한계 선형전류펄스변별기)

  • 김병찬
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.5 no.2
    • /
    • pp.8-14
    • /
    • 1968
  • A linear current-pulse discriminator consisting: of a transistor monostable multivibrator and a Si tunnel diode is described. The input currant pulse range is about 50$\mu$A~5.23mA. The measured maximum linearity deviation is $\pm$0.75% in the input current pulse range mentioned above. The pulse resolving ability of the discriminator measured depends upon the bias current through the T, D. ; and, under the reverse bias current of 3mA, the resolving time is 2rs if allow the excess pulse amplitude of 5%. The threshold stability of the discriminator depends mainly upon the stability of the peak current Ip of the T. D. ; and, under the ambient temperature variation from $0^{\circ}C$ to 5$0^{\circ}C$, no bigger threshold variation than the maximum linearity deviation, i. e. $\pm$ 0.75%, was observed.

  • PDF