• Title/Summary/Keyword: 임계온도

Search Result 561, Processing Time 0.029 seconds

Exponent Study of the p($2{\times}1$) Phase on an O/W(110) Surface (O/W(110) 표면의 p($2{\times}1$) 구조의 임계지수 연구)

  • 백두현;정석민;정진욱
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.1
    • /
    • pp.88-95
    • /
    • 1992
  • Abstract-Using a high resolution low energy electron diffraction(HRLEED), we report an exponent study of 2d continuous phase transition from an ordered ~ ( 2 x 1 )ox ygen overlayer on a W(110) surface. Temperature dependence of a (% 0) superlattice diffraction spot, characteristic of the p(2X 1) structure, shows power-law like divergence of the susceptibility and the fluctuation correlation length at T,=708.765 K. By fitting the intensities as well as the line-shapes, we obtained exponents P=0.19* 0.05, y=1.48+ 0.34, v= 1.23i 0.27 and q=0.38+ 0.12. The non-universal character of the exponents are understood in terms of a 2d XY model with cubic anisotropy as suggested previously.

  • PDF

Melt growth and superconducting properties of Sm-doped YBCO super-conductor by zone melting method (국부용융성장법으로 제조된 Sm이 첨가된 YBCO 초전도체의 용융온도 및 성장 속도에 따른 미세구조)

  • 김소정
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.14 no.2
    • /
    • pp.68-72
    • /
    • 2004
  • Sm-doped YBCO high $T_c$ superconductor was directionally grown by zone melt growth process in air atmosphere. Cylindrical green rods of $(Sm/Y)_{1.8}Ba_{2.4}Cu_{3.4}O_{7-x}$[(Sm/Y)1.8] oxides were fabricated by cold isostatic pressing (CIP) method using rubber mold. Based on the variation of melting temperature and growth rate, the microstructure and superconducting properties were systematically measured by using optical micrographs, TEM and SQUID magnetometer. In this study optimum melting temperature and growth rate were $1085^{\circ}C$ and 3.5 mm/hr respectively. Nonsuperconducting $(Sm/Y)_2BaCuO_5$ inclusions of (Sm/Y)1.8 superconductor were uniformly distributed within the superconducting (Sm/Y) $Ba_2Cu_3O^{7-x}$ matrix. The directionally melt-textured (Sm/Y)1.8 superconductor showed an onset $T_c$ $\geq$ 90K and sharp superconducting transition.

Alteration of mechanical properties of tunnel structural members after a tunnel fire accident (화재 후 터널구조물 시공재료의 역학적 특성변화)

  • Chang, Soo-Ho;Choi, Soon-Wook;Kwon, Jong-Wook;Kim, Sang-Hwan;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.2
    • /
    • pp.157-169
    • /
    • 2007
  • This study aimed to quantify the deterioration of tunnel structural members such as concrete lining and shotcrete lining after a tunnel fire accident by measuring their mechanical properties between $300^{\circ}C$ and $1,000^{\circ}C$. From the experiments, it was revealed that the critical temperature where mechanical properties start to decrease linearly was approximately $300^{\circ}C$. In addition, the other critical temperature where macro-cracks are induced in specimens was around $600^{\circ}C$. From a series of regression analysis, the optimum regression function with correlation coefficients over 0.99 for mechanical properties at different temperature levels was obtained as the Boltzmann function. Finally, a schematic diagram to estimate temperature distribution inside structural members as well as their mechanical properties at corresponding temperature levels quantitatively was newly proposed for RABT and RWS fire scenarios.

  • PDF

The effect of grid number and the location and size of the fire source on the critical velocity in a road tunnel fire (도로터널 임계풍속 산정에 격자개수 및 화원의 크기와 위치가 미치는 영향)

  • Lee, Seung-Chul;Kim, Sang-Il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.3
    • /
    • pp.183-195
    • /
    • 2012
  • This study conducted comparative analysis to estimate critical velocity in tunnel fire under variation of grid number and the location and size of the fire source using three-dimensional computational fluid dynamics. In the target tunnel, by one-dimensional way, the calculated critical velocity in the tunnel, 2.22 m/s was estimated, if appling hydraulic diameter, instead of the tunnel height. According to six numerical analysis, each grid number has different position, temperature, and CO concentration of back-layering. In the case of the subject, the case 1 with 0.84 million grid was found to be the most ideal. According to the location and size of the fire source, after three cases for three-dimensional numerical analysis was performed, it is resulted that the location and size of the fire source affect the critical velocity, because air velocity distribution, temperature distribution and CO concentration distribution showed different each case. This is due to the difference of heat exchange area and locations. Therefore, it is necessary to decide appropriate grid number, and the location and size of the fire source for processing techniques through comparison with actual experiment results and three-dimensional analysis.

제2세대 초전도선 개발

  • Ko, Rak-Gil;Park, Chan
    • Superconductivity and Cryogenics
    • /
    • v.6 no.2
    • /
    • pp.42-46
    • /
    • 2004
  • 금속 테이프 위에 초전도층을 박막형태로 증착시켜서 제조되는 고온초전도 선재인 coated conductor (CC)는 powder-in-tube 공정으로 제조되는 1세대 고온초전도 선재에 비해 액체 질소 온도에서 높은 임계 전류 밀도와 우수한 자장 특성을 가지면서 더 경제적으로 제조 가능하기 때문에 액체질소온도에서 작동 가능한 초전도전력기기 개발에 반드시 필요한 부분으로 인식되고 있다. 최근 국내외적으로 다양한 증착 방법을 사용하여 전력기기 응용이 가능한 장선의 CC 제조공정을 개발하려는 연구가 활발히 진행되고 있다. 특히 외국의 경우 이미 CC 선재의 상업화를 위해 기업체가 중심이 되어 집중적인 연구 개발이 이루어지고 있다.(중략)

  • PDF

Estimation of Gasification Performance and Slag System Capacity for 300MW IGCC Plant (300MW IGCC 가스화플랜트의 가스화 성능 및 Slag System 용량 예측)

  • Koo, Ja-Hyung;Paek, Min-Su;Yoo, Jeong-Seok;Kim, Bong-Keun;Kim, You-Seok;Lee, Hwang-Jik
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.234-237
    • /
    • 2008
  • 분류층 가스화기에서 가스화기 운전 온도는 슬래그의 원활한 배출과 가스화기 성능 등에 영향을 미친다. 가스화기 운전온도는 또한, 석탄 및 산소 소비량에도 영향을 미쳐 궁극적으로는 가스화 플랜트의 주요 설비 용량을 결정하는 주요 요인중의 하나이다. 가스화기 운전 온도가 일정수준 이상으로 증가할 경우 냉가스 효율이 저하되고 가스화 성능에 약 영향을 미친다. 본 논문에서는 Coal 및 Flux 공급장치, 슬래그 배출장치 당의 구성을 설명하고 Flux 투입량에 따른 슬래그 Tcv, 가스화기 성능 등을 예측하였다. 또한, 300MW IGCC 실증 가스화플랜트 엔지니어링을 위한 예비단계로 석회석 투입에 따른 Flux 공급장치를 포함한 Feeding 설비 용량, 슬래그처리설비 용량, 가스화기 내부 및 출구 적정온도를 예측하였다.

  • PDF

Thermal Buckling and Vibration Analysis of Composite Laminated Plates Using Shape Memory Alloy Fibers (형상기억합금 선을 삽입한 복합재료 적층판의 열적 좌굴 및 진동 해석)

  • 박재상;김지환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.916-921
    • /
    • 2001
  • 형상기억합금 선(Shape Memory Alloy Fibers : SMA Fibers)을 삽입한 복합재료 평판의 고온 환경에서의 열적 좌굴 및 진동 해석을 유한요소법을 이용하여 수행하였다 1 차 전단변형이론을 적용하여 적층판을 모델링하였고, 온도 변화 효과는 적층판의 전 영역에서 균일한 온도 분포로 가정하였다. 형상기억합금 선의 온도에 대한 비선형 재료 성질을 고려하여 열적 좌굴 해석 수행 시 반복 계산법을 이용하였고, 자유 진동 해석에서는 시스템의 자유도를 줄이기 위하여 Guyan-Reduction(CR)을 사용하였다. 온도 변화와 형상기억합금 선의 체적비(volume fraction) 및 초기 변형률(initial strain) 변화에 따른 임계 온도와 고유 진동수의 특성을 해석하였다.

  • PDF