• Title/Summary/Keyword: 일사부하

Search Result 65, Processing Time 0.022 seconds

Study of Pre-ventilation Effects on the Cabin Thermal Load (주차환기 시스템이 차 실내 열부하에 미치는 영향에 관한 연구)

  • Lee, Daewoong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.5
    • /
    • pp.84-90
    • /
    • 2014
  • The aim of this paper is to investigate the application of solar energy in reducing cabin thermal load. When a vehicle is parked under the sun in summer, the interior temperature can reach up to $70^{\circ}C$ depending on the solar intensity. Solar power, one of the green energies, is used in automobile air conditioning systems, in order to operate the blower. The power supply of a blower's voltage has been used in a solar sunroof experiment. At the climate wind tunnel, cabin temperature changes were conducted with various operating modes of an air handling system and the preventilation parking conditions of several vehicles, outdoors, was also examined. The test results of the solar sunroof, 39.3W power and 14.1% efficiency were obtained. The thermal load behavior was analysed with the air handling system operating mode differently according to the cabin temperature. By simply operating the blower, average cabin temperature decreased between $5^{\circ}C{\sim}10^{\circ}C$ in those vehicles parked outdoors in summer. This reveals that cabin thermal comfort can be improved without consuming the vehicle's extra energy, and that the performance of the air-conditioning system is better than those currently found in vehicles. Moreover, fuel economy will be increased as a result of the reduction in the use of the air-conditioning system, and many other human advantages will be gained. Such advantages include minimized VOCs and a healthy cabin environment.

A Sensitivity Analysis about Solar Heat Gain and Heating Load of ZeSH According to Optical Characteristics of Window system (창호의 광학적 특성에 따른 ZeSH의 일사취득 및 난방부하에 관한 민감도 분석)

  • Son, Sun-Woo;Baek, Nam-Choon;Suh, Seung-Jik
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.66-71
    • /
    • 2009
  • To reduce the building energy consumption, the major advanced nations are conducting actively many researches on so called a "self-sufficient building(or other words zero energy building)" which can support its required energy by itself. Given this background, KIER(Korea Institute of Energy Research) built full size test-bed of the zero energy solar house in early 2002, and has studied on the self-sufficient heating load up to now. We analyse the sensitivity between the heating load and the solar radiation gain according to the change the effective transmittance of windows. The authors classified 9 cases by solar transmittance of glass. The results demonstrate the solar radiation amount is 0.466 MWh from the eastern zone of Fl.,1(the first floor), 0.332 MWh from Fl.,2(the second floor), 1.194 MWh form the southern zone of F1., and 0.822 MWh from the southern zone of Fl.,2 on the case 1(each cases are classified by window types). On the case 9, the solar radiation amount is 3.127 MWh, 2.662 MWh, 8.799 MWh and 6.078 MWh from the same condition. For the Fl.,1, the amount of Heat Load that is saved per year ranged 10.5 to 48 %, and the reduction was anywhere from 0.2 to 17.9% for Fl.,2

  • PDF

The Performance and Energy Saving Effect of a 2kWp Roof-Integrated Photovoltaic System (주택지붕용 2kWp BIPV시스템의 성능 실험 및 전기 부하 감당에 관한 연구)

  • Lee, Kang-Rock;Oh, Myung-Tack;Park, Kyung-Eun;Kim, Jin-Hee;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.1
    • /
    • pp.13-19
    • /
    • 2006
  • The efficiency of building-integrated photovoltaic(BIPV) system is mainly determined by solar radiation and the temperature of PV modules. The performance of BIPV systems is reported to be different from that of conventional PV systems installed in the open-air. This paper presents the relationship of solar radiation and electricity generation from a 2kWp roof-integrated PV system that is applied as building elements on an experimental house, and the energy saving effect of the BIPV system for a typical house. For the performance evaluation of the BIPV system, it produced a regression equation with measured data for winter days. The regression equation showed that a comparison of the measured electricity generation and the predicted electricity generation of the BIPV system were meaningful. It showed that an annual electricity generation of the system appeared to cover around 52% of an annual electricity consumption of a typical domestic house with the floor area of $96m^2$.

A Study on the Reduction effect of Peak Cooling Load on the Sunshade effect of BIPV System (BIPV 시스템의 차양 효과에 따른 피크 냉방부하 절감효과에 관한 연구)

  • Lee, Chung-Sik;Lee, Eung-Jik;Lee, Chul-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.14-20
    • /
    • 2008
  • As the number of buildings that use the transparent permeation materials as the outer wall is on the increase, the coming amount of the light rays is a lot, and thus the increase in the cooling load and the radiant heat of high temperature may cause the residents to discomfort. In order to reduce such influences, this paper analyzed the installation effects of the sunshade BIPV. The inner temperature of the room installed the sunshade BIPV or otherwise was measured, and compared and analyzed the effects of reducing the cooling load by the incoming light rays. The sample space of the third floor of S university installed the sunshade BIPV has two rooms on the same conditions, and for five sunny days selected in August, the researcher measured the air temperature and the temperature of the fittings with closing the windows to minimize the movement of air without operating the coolers. The maximum cooling load measured by the incoming light rays in the room where the sunshade BIPV was not installed was examined as 459.13kcal/h. It can be understood as the effect of reducing the cooling load according to the incoming rays of the room with sunshade BIPV. Even though the effect of cooling load reduction is not so great in a room, the total reduction in cooling room for the 32 rooms installed the sunshade BIPV was estimated to be 40442.27kcal/day, which will be able to bring the maximum reduction effect of 17.1kW in energy and reduce the investment cost owing to the reduction in cooling load when initially designing the building.

태양전지 배열기의 최대 전력 추적 알고리즘 개발

  • Park, Hee-Sung;Jang, Sung-Soo;Jang, Jin-Baek;Park, Sung-Woo;Lee, Jong-In
    • Aerospace Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.77-85
    • /
    • 2005
  • MPPT(Maximum power point tracking) is used in photovoltaic systems to maximize the solar array output power, irrespective of the temperature and irradiation conditions and of the load electrical characteristics. In this paper, new MPPT algorithm is proposed for the small satellite in LEO. As the proposed MPPT algorithm does not need any calculation of power by multiplication of voltage and current, it can be made by the simply analog circuit. In this study, the proposed MPPT algorithm is verified by the simulation and experimental in the many conditions that can change the characteristics of the solar array.

  • PDF

Human Solar Heat Load and Thermal Comfort in an Outdoor Environment (건축외부공간에 있어서 인체의 일사열부하(日射熱負荷) 및 열적(熱的) 쾌적성(快適性)에 관한 실험적 연구)

  • Jeong, Chang-Won;Yoon, In
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.1 no.2
    • /
    • pp.65-74
    • /
    • 1998
  • The purpose of this paper is to investigate the mount of relief of human solar heat load and thermal comfort in outdoor environment in summer, Six different types of sites, T garden and its neighboring area in Japan, were selected as the experiment sites. The experiments were conducted from 22 to 29 August, 1994 to find the relationship between climatic conditions and human responses, Climatic conditions, subjects's thermal sensation and skin temperature were measured. Radiant heat exchange on the human body was estimated on the basis of the measured air and surface temperature and solar radiation. Thermal index Operative Temperature and New Effective Temperature was modified with the effect of the radiant heat exchange. Human thermal comfort and skin temperature is affected by the solar radiation and the sky factor in an outdoor environment. The effect of tree shade was verified on thermal comfort, The mount of relief of human solar heat load is relation to the existence of shade a solar radiation and the sky factor. The urban garden is one of the effective design element in an urban environmental planning.

  • PDF

Comparative Analysis of Weather Data for Heating and Cooling Load Calculation in Greenhouse Environmental Design (온실의 냉난방부하 산정을 위한 외부기상자료 비교분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho;Seo, Dong-Uk
    • Journal of Bio-Environment Control
    • /
    • v.23 no.3
    • /
    • pp.174-180
    • /
    • 2014
  • Standard weather data available to greenhouse environmental design are limited in most regions of the country. So, instead of using standard weather data, in order to find the method to build design weather data for greenhouse heating and cooling, design outdoor weather conditions were analyzed and compared by TAC method and frequency analysis using climatological normal and thirty years from 1981 to 2010 hourly weather data provided by KMA and standard weather data provided by KSES. Average TAC values of outdoor temperature, relative humidity and insolation using thirty years hourly weather data showed a good agreement with them using standard weather data. Therefore, in regions which are not available standard weather data, we suggest that design outdoor weather conditions should be analyzed using thirty years hourly weather data. Average of TAC values derived from every year hourly weather data during the whole period can be established as environmental design standards, and also minimum and maximum of them can be used as reference data.

A Study on AC/DC Power Converter of Energy Harvesting for Considered to Solar Position Tracking Control (태양광 위치 추적 제어를 고려한 에너지 Harvesting AC/DC 전력 변환기 구동에 관한 연구)

  • Na, Seung-Kwon;Ku, Gi-Jun
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.1
    • /
    • pp.56-66
    • /
    • 2014
  • In this paper, the solar cell need the characteristic interpreting because the solar cell changes greatly according to the isolation, temperature and load in the photovoltaic development. Moreover, to get many energy in photovoltaic development need the position tracking of the sun according to the environment change and it is necessary to control the output of solar cells up to the time. Simulation and composed microprocessor and sensor chip an power conversion system with boost converter to experiment results are performed to prove the analysis of the converter operation, and to show the possibility of energy harvesting and photovoltaic development need the position tracking small capacitance, the boost rate of boost converter was similar to 167 percent.

RF-Magnetron Sputtering으로 제조된 근적외선 차폐용 나노 박막 소재를 이용한 고투과성 단열창호 연구

  • Kim, Hye-Jin;Lee, Geon-Hui;Seo, Mun-Seok;Han, Jong-Hun;Sin, Gwon-U;Kim, Seon-Min;Jo, Jin-U
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.221-221
    • /
    • 2011
  • 최근, 대외적으로 기후변화협약 등 환경에 대한 관심이 높아지면서 국내에서도 온실가스 배출이 큰 에너지의 22.3%를 소비하고 있는 건축물로 인한 환경부하에 관심이 높아지며 고효율 창호의 필요성이 대두되고 있다. 기존의 Low-E (저방사) 유리는 적외선을 반사시켜 단열 유리로서 겨울철에 유리하지만, 건물 전면에 약 50~95% 창호가 사용되는 office 건물에는 여름철 냉방에너지를 많이 사용하기 때문에 단열뿐만 아니라 일사 차폐가 가능한 근적외선 차폐유리가 필요하다. 따라서 본 연구에서는 기존의 Low-E 유리의 문제점인 근적외선 투과문제를 해결하기 위한 기술로서 근적외선 영역을 선택적으로 차폐할 수 있는 박막코팅 물질(흡수체, 반사체) 및 Low-E 대체용 Themochromic 등 나노 박막을 RF magnetron sputtering으로 제조하여 복층유리 구조로 조합해 UV-visible을 측정하였으며 IR Lamp와 태양광 아래에서 온도변화 실험을 진행하였다. 그 결과, 기존 Low-E 복층유리 대비 본 실험에서 사용한 복층유리의 근적외선 차폐효율이 개선됨을 확인하였다.

  • PDF

A Study on Change in Window Transmitted Solar and the Resultant Wall Surface Convective Heat Gain with Regard to Slat Reflectance of External and Internal Blinds (실내·외 블라인드의 Slat 반사율에 따라 창호 일사투과량 및 그에 따른 벽체 대류열획득량 분석)

  • Hyun, In-Tak;Lee, Jae-Ho;Yoon, Yeo-Beom;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.565-571
    • /
    • 2014
  • Nowadays, to make buildings light weight and aesthetically pleasing, curtain wall structure are commonly used. Therefore, window to wall ratio is increasing, which has caused cooling and heating load in crease in buildings as well. This phenomenon has negative impact from energy point of view. This paper analyzes window and wall convective heat gain when the slat reflectance of external and internal blinds are changed for the better understanding of the fundamentals behind the phenomena. It was observed that, if slat reflectance is increased, window transmitted solar increases and convection heat rate is clearly affected. Among six surfaces including four walls, ceiling and floor, maximum convection heat rate occurs on the south wall in summer. On the other hand, ceiling and floor showed the lowest convection heat gain, since they are shared by adjacent floors.