• 제목/요약/키워드: 일반콘크리트

검색결과 1,168건 처리시간 0.027초

Properties of portland cement concrete with the addition of a modified sulfur polymer (개질 유황 고분자가 혼입된 포틀랜드 시멘트 콘크리트의 특성)

  • Yu, Seung-Gun;Choi, Heon-Jin;Kwon, Hyok;Park, No-Kyung;Kim, Goo-Dae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • 제20권4호
    • /
    • pp.192-196
    • /
    • 2010
  • This paper describes the effects of modified sulfur polymer content on the compressive strength and chemical resistance of Portland cement concrete with and without the modified sulfur polymer. The Portland cement concrete which contained modified sulfur had much higher strength than the Portland cement concrete without modified sulfur, workability is stabled at $55^{\circ}C$. Alkali tolerance test was evaluated by immersing these concrete specimens in 13 % $CaCl_2$ solutions. In the alkali tolerance test, the resistance of Portland cement concrete with modified sulfur to $CaCl_2$ increased compared with Portland cement concrete without modified sulfur.

A Study on the Flowability Properties of the High Flowing Self-Compacting Concrete for Members of Bridge Precast (프리캐스트 교량부재용 초유동 자기충전 콘크리트의 유동 특성에 관한 연구)

  • Choi, Yun Wang;Kim, Yong Jic;Kang, Hyun Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제28권1A호
    • /
    • pp.155-163
    • /
    • 2008
  • On the construction site with trends of large scale, high rise and specialization, testing construction of high performance concrete, superior to conventional concrete, is continued to increase. For bridge construction, application of full staging method is gradually decreasing due to noise, dust, and prolonged construction period. Recently, precast construction, which is optimized to urban environment and shorter work period, gains popularity significantly. In bridge structure, overcrowding arrangement of bar is used to ensure its safety. For the manufacturing of overcrowding arrangement of bar, High flowing self-compacting concrete, which is superior to conventional concrete in flowability and compacting property, should be implemented. In this study, the application of blast-furnace slag and fly ash to binary and ternary blended system on the High flowing self-compacting concrete for bridge structure with overcrowding arrangement of bar is evaluated by flowability in accordance with the first class regulations of Japan Society of Civil Engineering (JSCE).

Mechanical Properties of High-Early-Strength Concrete for Early Traffic Opening (조기교통개방 콘크리트의 강도특성)

  • Won, Jong-Pil;Kim, Hyun-Ho;Ahn, Tae-Song
    • International Journal of Highway Engineering
    • /
    • 제3권2호
    • /
    • pp.123-130
    • /
    • 2001
  • This study was performed to enhance mechanical properties of high-early-strength concrete using regulated-set cement for early traffic opening with various mixtures. Restraint of moisture and thermal movements of concrete pavement in actual field conditions, by external or internal restraining factors, generates tensile stresses which introduce microcracks and thus reduce the mechanical properties of concrete. Fiber reinforcement of concrete is an effective approch to the control of microcrack and crack development under tensile stresses. Three different types of regulated-set cement which recently have been used in Korea and two different types of fiber were adopted. Fibers were added and their mixtures are compared with plain high-early-strength concrete mixture. From the test results, fiber reinforced concrete was increased mechanical properties of high-early-strength concrete using regulated-set cement than the plain concrete.

  • PDF

Properties of Heavyweight Concrete for Radiation Shielding (방사선 차폐용 중량콘크리트의 기초 특성)

  • Yang, Seung-Kyu;Um, Tai-Sun;Lee, Jong-Ryul;Kim, Yong-Ho;Wu, Sang-Ik;Kim, Tae-Bong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.561-564
    • /
    • 2008
  • Concrete is considered to be one of the excellent and versatile shielding material and is widely used for the radiation shielding material. Specially, heavyweight(or high density) concrete is used in counter weights of bascule and lift bridges, but it is generally used in radiation shielding structures and differ from normal weight concrete by having a higher density and special compositions to improve its attenuation properties. Thorough examination and evaluation of heavyweight aggregate sources are necessary to obtain material suitable for the type of shielding required. Therefore, this paper aims to study mechanical properties of heavyweight concrete by using normal cement, natural and heavyweight aggregate.

  • PDF

Enhanced Durability Performance of High Early Strength Concrete for Early Traffic Opening (조기교통개방 콘크리트의 내구성능 향상에 관한 연구)

  • 원종필;김현호;안태송
    • Journal of the Korea Concrete Institute
    • /
    • 제13권4호
    • /
    • pp.362-370
    • /
    • 2001
  • The internal or external restraint of thermal and dry shrinkage movements could thus generate tensile stresses in concrete pavement for early traffic opening. Restrained shrinkage and thermal stresses could produce microcracks in concrete which increase its permeability and accelerate its long-term deterioration under weathering and load effects. Fiber reinforced concrete is an effective approach to the control of microcrack and crack development under tensile stresses. This study aims at evaluation of the durability of high early strength concrete for early traffic opening and increase of service life. Three different types of regulated-set cement which recently has been used much in Korea were adopted. Fibers were added and their mixtures were compared with plain high early strength concrete mixture. The use of fibers increased durability performance of high early strength concrete using regulated-set cement than the corresponding plain mixtures.

An Experimental Study on the Flexural Characteristics of Water-permeable Concrete reinforced with Wire Mesh and Fibers (와이어 매쉬 및 섬유 종류별 보강된 투수 콘크리트의 휨특성에 관한 실험적 연구)

  • Lee, Byung-Jae;Park, Seong-Bum;Jang, Young-Il;Jun, Heum-Jin;Hyun, Ji-Hong;Cho, Kwang-Yun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.367-368
    • /
    • 2010
  • Having function to reducing environmental load, water-permeable concrete has advantages to ground permeation of rain-water and sound absorbtion, heat island reduction, etc., but represents the low flexural characteristics compared with general concrete. Therefore, this study analyzed the flexural characteristics by producing water-permeable concrete mixed with wire mesh or fiber reinforcing for improvement to the flexural characteristics of water-permeable concrete.

  • PDF

A View on Water-Leakage and Countermeasure of Concrete Structure (콘크리트 구조물의 누수와 대처 방안에 대한 견해)

  • 오상근
    • Magazine of the Korea Concrete Institute
    • /
    • 제14권6호
    • /
    • pp.14-19
    • /
    • 2002
  • 과연 콘크리트 구조물에 있어서 누수 균열은 문제가 되는 것일까? 이에 대해 설계, 구조 시공, 재료(콘크리트), 방수, 품질 및 안전의 관련 전문가는 여러 가지 이견을 말하고 있다. 또한 콘크리트 구조물에 관계하는 발주자, 건축주, 사용자, 시공자의 입장도 상황에 따라 다르게 해석하고, 평가하고 있다. 예를 들면 일반적으로 발주자(건축주 등)는 시공자에게 누수 균열은 하자이므로 무조건 보수할 것을 요구하는 반면 사용자(언론 포함)가 문제를 제기할 때(공공공사의 경우) 발주자는 이에 대해 크게 문제되지 않는다고 답변하는 경우도 많다. 어떤 기술자는 콘크리트의 누수 균열은 피할 수 없는 사항이므로 근본적으로 해결할 수 없으므로 완벽한 시공 및 보수는 어렵고, 다만 전체적인 누수량이 어느 정도 이하가 되도록만 관리할 뿐이라고 말하고, 또한 지하 구조물의 누수 균열은 피할 수 없어, 누수를 시각적으로 가리기 위한 보호벽을 쌓아 관리하는 것이 당연하다고 말하는 기술자도 있다. 그럼에도 불구하고 일반 사용자들은 무조건 누수균열이 없어야 한다고 의견을 제시하고 있다. 특히 언론에 구조물 누수의 문제가 수시로 보도되어 관계자 및 관련 건설기술자들의 자존심이 크게 훼손되고, 이를 보수하기 위한 비용이 엄청나게 지출되고 있음을 볼 때 적당히 간과해서는 안될 문제임에는 틀림없다.(중략)

An Experimental Study on Fire Resistance Performance of Normal Strength Reinforce Concrete Column (일반강도 철근콘크리트 기둥의 내화성능에 관한 실험적 연구)

  • Cho, Kyung-Suk;Yeo, In-Hwan;Cho, Bum-Yeon;Park, Kyung-Hoon;Min, Byung-Ryeol
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 한국화재소방학회 2010년도 추계학술발표회 자료집
    • /
    • pp.297-301
    • /
    • 2010
  • 일반콘크리트 기둥을 대상으로 콘크리트 피복두께와 단면크기를 변수로 하여 내화성능을 평가하였다. 피복두께가 늘어남에 따라 내화성능시간도 다소 늘어 피복두께와 내화성능은 비례적 관계에 있는 것으로 나타났다. 단면크기가 커짐에 따라 실험체의 열용량이 증가하여 내화성능이 좋아질 것으로 예상하였으나 폭렬의 영향으로 인하여 단면크기에 따른 내화성능의 변화는 큰 의미가 없는 것으로 나타났다. 따라서 콘크리트 기둥의 내화성능은 폭렬 여부에 의해 크게 지배되는 것으로 판단된다.

  • PDF

Affecting Analysis of Air Content on the Freeze-Thaw Durability of Concrete (콘크리트의 동결융해 내구성에 공기량이 미치는 영향 분석)

  • Lee, Beung-Duk;Kim, Hyun-Joong;Kang, Hye-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.565-568
    • /
    • 2008
  • Domestic area of most be happened chloride deicer damage. Because daily mean temperature is below 0$^{\circ}C$ from the area of domestic most. Concrete durability influence Air Content. Presently, We used to AE(air-entraining agent) for increase freeze-thaw durability. So, on concrete Air Spacing ratio used $200{\mu}m{\sim}230{\mu}m$ in Canada and under $250{\mu}m$ in Japan institution. Use of Air content has been and will continue to be a major part of concrete durability and scaling. Chloride-containing chemicals such as calcium chloride or rock salt are main deicers for the road. The prepared optimum mix concrete in this study show that freeze-thaw and scaling resistance of Non-AE(air content 1.5%) and AE (air content 4.5%, 7.2%). Solution concentrations of deicing agent were good result, and the pore system and change of hydration products is not difference comparing before freeze-thaw test.

  • PDF

Mix Design of High Performance Concrete Using Maximum Density Theory (최대 밀도 이론을 이용한 고성능콘크리트의 배합 설계)

  • Lee, Seung-Han;Jung, Yong-Wook
    • Journal of the Korea Concrete Institute
    • /
    • 제19권3호
    • /
    • pp.377-383
    • /
    • 2007
  • In recent years the field application of high performance concrete has been increased to improve the quality and reliability of concrete structures. The mix design of the high performance concrete includes the 2 set-off mixture theory of mortar and coarse aggregate and that of paste and aggregate. The 2 set-off mixture theory of mortar and coarse aggregate has a problem of having to determine its value through repeated experiments in applying the rheological characteristics of mortar. The 2 set-off mixture theory of paste and aggregate has never been applied to high performance concrete since it doesn't take into account the relationship between optimum fine aggregate ratio and unit volume of powder nor does it consider the critical aggregate volume ratio. As the mixture theory of these high performance concretes, unlike that of general concrete, focuses on flowability and charge-ability, it does not consider intensity features in mix design also, the unit quantity of the materials used is determined by trial and error method in the same way as general concrete. This study is designed to reduce the frequency of trial and error by accurately calculating the optimum fine aggregate ratio, which makes it possible to minimize the aperture of aggregate in use by introducing the maximum density theory to the mix design of high performance concrete. Also, it is intended to propose a simple and reasonable mix design for high performance concrete meeting the requirements for both intensity and flowability. The mix design proposed in this study may reduce trial and error and conveniently produce high performance concrete which has self-chargeability by using more than the minimum unit volume of powder and optimum fine aggregate with minimum porosity.