• Title/Summary/Keyword: 인화점

Search Result 197, Processing Time 0.035 seconds

A Study on Development of Alternative Non-aqueous Cleaning Agents to Ozone Depletion Substances and its Field Application (오존파괴물질 대체 비수계세정제 개발 및 현장 적용 연구)

  • Park, Yong-Bae;Bae, Jae-Heum;Lee, Min-Jae;Lee, Jong-Gi;Lee, Ho-Yeoul;Bae, Soo-Jung;Lee, Dong-Kee
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.306-313
    • /
    • 2011
  • Flux or solder is used in soldering process for manufacturing electronic parts such as printed circuit boards (PCB). After soldering process, residual flux and solder paste on the parts should be removed since their residuals could cause performance degradation or failure of parts due to their corrosion and electric leakage. Ozone depletion substances such as 1,1,1- trichloroethane (TCE) and HCFC-141b have widely been using for removal of residual flux and solder paste after soldering process In manufacturing of electronic parts until now. In this study, non-aqueous cleaning agents without flash point were developed and applied to industrial field for replacement of cleaning agents with ozone depletion. In order to develop non-aqueous cleaning agents without ethers, esters, fluoride- type solvents. And their physical properties and cleaning abilities were evaluated, and they were applied to industrial fields for cleaning of flux and solder on the PCB. And vacuum distillation apparatus were operated to determine their operating conditions and recycling yields for recycling of used cleaning agents formulated in this study. As a result of physical properties measurement of our formulated cleaning agents, they were expected to have good wetting and penetrating power since their surface tensions were relatively low as 18.0~20.4 dyne/$cm^2$ and their wetting indices are relatively large. And some cleaning agents holding fluoride-type solvents as their components did not have any flash point and they seemed to be safe in their handling and storage. The cleaning experimental results showed that some cleaning agents were better in their cleaning of flux and solder paste than 1,1,1-TCE and HCFC-141b. And industrial application results of the formulated cleaning agents for cleaning PCB indicated that they can be applicable to industry due to their good cleaning capability in comparison with HCFC-141b. The recycling experiments of the used formulated cleaning agents through a vacuum distillation apparatus also showed that their 91.9~97.5% could be recycled with its proper operating conditions.

Numerical Study on Atmospheric Dispersion and Fire Possibility in Toluene Leakage (톨루엔 누출 시 대기확산 및 화재가능성에 관한 수치해석 연구)

  • Ko, Jae Sun;Kim, Joo-Seok
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.1-10
    • /
    • 2017
  • This study examined the risk of accidents when handling hazardous materials in hazardous materials storage facilities without safety facilities. In the case of illegal dangerous cargo containers, the burning rate is very fast in the case of fire, which leads to explosions, that are damaging and difficult to control. In addition, accidents that occur in flammable liquid hazardous materials are caused mostly by accidents that occur in the space due to leakage. Therefore, the variables that affect these accidents were derived and the influence of these variables was investigated. Numerical and computational fluid dynamics programs were used to obtain the following final results. First, when a flammable liquid leaks into a specific space, it is influenced by temperature and relative humidity until a certain concentration (lower limit of combustion) is reached. In the case of temperature, it was found that the reaching time was shorter than the flash point In addition, the effect of variables on pool fire accidents of leakage tanks is somewhat different, but the variables that have the largest influence are the wind speed. Therefore, it is expected that the results of this study will be used as basic data for similar numerical analysis and it will provide useful numerical information about the accidental leakage of hazardous materials under various research conditions.

Changes of Properties and Gas Components according to Accelerated Aging Test of Vegetable Transformer Oil (식물성 절연유의 가속열화에 따른 주요 성분 및 물성 변화)

  • Lee, Donmin;Lee, Mieun;Park, Cheonkyu;Ha, Jonghan;Park, Hyunjoo;Jun, Taehyun;Lee, Bonghee
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.18-26
    • /
    • 2016
  • Mineral oil is the most widely used for electrical transformer, though some factors should be considered such as their environmentally harmfulness when it spill and low flash point. To cover these disadvantages, vegetable oil has developed because of its high biodegradability and thermal stability. However, it is necessary that many studies should conduct to reveal the detailed impacts of long-term operation as transformer oil. In this paper, we applied the accelerated aging test which simulate the real transformer circumstances using insulation paper, coil, steel at $150^{\circ}C$, which is higher than normal operation, for 2 weeks. To figure out the oxidation characteristics between mineral oil and vegetable oil test major properties and components such as total acid number, dielectric breakdown and dissolved gas components during that period. As a result of these tests, we found that vegetable oil has higher electric insulation ability than mineral oil though poor total acid number by hydrophile property. Vegetable oil also kept its thermal stability under the given circumstances.

A Study on Applicability of Hydrofluoroethers as CFC-Alternative Cleaning Agents (CFC 대체 산업세정제로의 HFEs의 적용가능성 연구)

  • Min, Hye-Jin;Shin, Jin-Ho;Bae, Jae-Heum;Kim, Hong-Gon;Lee, Hyun-Joo
    • Clean Technology
    • /
    • v.14 no.3
    • /
    • pp.184-192
    • /
    • 2008
  • Fluoride-type cleaning agents such as 2,2,2-trifluoroethanol (TFEA) and hydrofluoroethers (HFEs) do not destroy ozone in the stratosphere and have low global warming potential compared to hydrofluorocarbons(HFCs) and hydrochlorofluorocarbons (HCFCs). Especially, HFEs which have no flash point are paid attention as next generation type of cleaning agents for chlorofluorocarbons (CFCs) since they are safe in handling and have excellent penetration ability compared to hydrocarbon cleaning agents with low flash point. Here, the physical properties and cleaning abilities of fluoride-type cleaning agents such as TFEA, HFE-7100, HFE-7200, HFE-476mec, HFE-449mec-f, AE-3000 and AE-3100E and silicide-type cleaning agents such as trifluoroetoxytrimethylsilane (TFES) and hexamethyldisilazane (HMDS) were measured and compared with those of ozone destruction substances such as CFC-113 and 1,1,1-trichloroethane. They were also compared with toxic methylene chloride (MC) and isopropyl alcohol (IPA) which are now being used as an alternative cleaning agents. As a result, TFEA and HFEs had lower cleaning ability for removal of various soils compared to chloride-type cleaning agents, but they showed excellent cleaning ability fur fluoride-type soils. TFES and HMDS also showed excellent cleaning ability for silicide-type soils.

  • PDF

Insulation Properties and Evaluation of Diglycerol Ester Synthesized by Solid Acid Catalysts (고체산 촉매를 이용해 합성한 diglycerol ester의 전기절연 특성 및 평가)

  • Gwon, Miseong;Baek, Jae Ho;Kim, Myung Hwan;Park, Dae-Won;Lee, Man Sig
    • Applied Chemistry for Engineering
    • /
    • v.25 no.3
    • /
    • pp.254-261
    • /
    • 2014
  • The transformer is a static electrical device that transfers energy by inductive coupling. Then, heat is occurred at coils, inner transformer was filled with insulating oils for cooling and insulation. Although mineral oil as insulating oil has been widely used, it does not meet health and current environmental laws because it is not biodegradable. Therefore, in this study, the diglycerol ester was synthesized with diglycerol and fatty acids (oleic acid and caprylic acid) over various catalysts for insulating oil having biodegradability, high flash points and low pour points. The sulfated zirconia ($SO_4{^{2-}}/ZrO_2$) catalyst prepared at different calcination temperature shows the highest conversion of fatty acids at $600^{\circ}C$ due to crystallinity and high density of acid sites per surface area. When the molar ratio of oleic acid and caprylic acid is 1:3, the diglycerol ester shows superior insulation properties that are the flash point of $306^{\circ}C$ and pour point of $-50^{\circ}C$. The insulation properties of synthesized diglycerol ester shows the pour point of $-50^{\circ}C$ and the flash point of over $300^{\circ}C$. Therefore, diglycerol ester is superior to the vegetable oils in insulation properties.

A Study on the Applicability of $C_5$ Hydrofluoroether-based Formulated Cleaning Agents as CFC-Alternatives ($C_5$계 수소불화에테르를 기반으로 하는 배합 세정제의 CFC 대체세정제 적용 연구)

  • Min, Hye-Jin;Bae, Jae-Heum;Chang, Yoon-Sang
    • Clean Technology
    • /
    • v.16 no.3
    • /
    • pp.172-181
    • /
    • 2010
  • Hydrofluoroethers (HFEs) with fluoride molecules in their structure which are evaluated as the third generation replacement alternatives to chlorofluorocarbons (CFCs) are known to be excellent for removal of nanoparticles and fluoride-type soils due to their low surface tension and high wetting index. In addition, HFEs have good physical properties with no flash point and excellent drying characteristics. But, HFEs also have shortcomings in that they are not effective for removal of organic soils due to their poor solubility in soil. In this study, $C_5$ HFE-based cleaning agents were formulated through addition of solvents such as isopropyl alcohol (IPA), ethyleneglycol monoether (EG), propyleneglycol monoethylether (PM) to HFE-7100 [$CF_3CF_2CF_2CF_2OCH_3$] or HFE-mec-f [$CF_3CHF=CF_2OCH_2CF_3$] with its maximum amount, respectively, in order to have no flash point for the safety in the working environment. These solvents are known to be excellent for dissolving organics in soil. Their physical properties and cleaning abilities for fluxes, water-insoluble cutting oils, and fluoride-type oils were evaluated and compared with those of other cleaning agents with single components. The experimental results show that the HFE-based formulated cleaning agents have various good physical properties which are almost similar to those of a single type of HFE cleaner. They show excellent cleaning ability for fluxes, water-insoluble cutting oils, and fluoride-type oils. These results indicate that the HFE-based formulated cleaning agents can be applicable to various industrial cleaning fields because of their good physical properties and cleaning abilities for various soils.

Preparation of Heating Fuel by the Recycling of High Viscosity Waste Oil (고점도 폐유의 재활용에 의한 난방연료 제조)

  • Jin, Eui;Chung, Yeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.20 no.4
    • /
    • pp.411-415
    • /
    • 2009
  • To replace waste oil with the lowest grade which has high viscosity into heating fuel, light oil and buncker C oil in waste oil was used and the fuel characteristic was analyzed by its concentration after mixing oil. The mixture conditions were controlled by the reaction time (30 s~30 min) and kept by the reaction temperature ($75{\pm}5^{\circ}C$) when mixing speed was stirred at 3400~3600 rpm. We used the buncker C oil and light oil to decrease viscosity of waste oil and the dynamic viscosity was decreased by 81~96%. Optimum mixing ratio (waste oil : buncker C oil : light oil) as heating fuel was 1 : 1 : 1. Flash point, dynamic viscosity and heating value of this case were identified $78^{\circ}C$, $20.02mm^{2}/s$, 9158 kcal/L respectively.

Thermal Fluid Flow Analysis of Environment-Friendly Power Transformer Using CFD (CFD를 이용한 환경친화형 전력용 변압기의 열유동해석)

  • Kim, Ji-Ho;Kim, Jong-Wang;Kweon, Dong-Jin;Woo, Jung-Wook;Koo, Kyo-Sun;Lee, Hyang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.924-925
    • /
    • 2011
  • 본 논문에서는 환경친화적이고, 인화점 및 발화점이 높아 화재의 위험도가 낮은 식물성 절연우를 기존 변압기의 광유를 대체로 사용하기 위한 열적 특성을 열유동해석을 이용하여 온도분포를 수치해석을 통하여 예측하였다. 해석모델로는 154kV 급 단상 내철형 유입자냉식 변압기를 대상으로 CFD 해석을 수행하였으며, 광유와 식물성 절연유는 부하의 변화에 따른 온도특성을 파악하는 동시에 핫스팟(hot spot)을 예측하였다. 본 논문은 변압기를 3차원 모델링하여 유동 및 온도 분포를 해석한 결과, 변압기의 내부 온도 및 핫스팟 추적에 대하여 변압기의 수명에 대한 예측이 가능하며, 식물성 절연유를 사용한 전력용 변압기 온도 분포 해석결과는 식물성 절연유의 적용 및 냉각 설계 변경에 기초자료롤 활용될 것이다.

  • PDF

Measurement of Flash Points for n-hexanol+n-butyric acid and n-butanol+propionic acid by Seta-flash Closed Cup Method (Seta-flash 밀폐식 방법에 의한 n-hexanol+n-butyric acid 계와 n-butanol+propionic acid 계의 인화점 측정)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.76-80
    • /
    • 2014
  • The flash point is one of the most important physical properties used to determine the fire hazard of flammable liquid mixture and defined as the lowest temperature at which a liquid produces sufficient vapor to form a combustible mixture with air. The main purpose of this paper is to measure and predict the flash point of binary flammable miscible mixtures. The flash points for n-hexanol+n-butyric acid and n-butanol+propionic acid, were measured by using Seta-flash closed cup method. The experimentally derived data were correlated with the binary interaction parameters of the van Laar and NRTL equations through the optimization method. The flash points estimated by these correlations were compared with those calculated by the method based on Raoult's law. The optimization method were found to be better than the method based on the Raoult's law.

Dew Point Prediction by Lower Flash Points of Binary Mixtures (이성분계 혼합물의 하부 인화점에 의한 이슬점 예측)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.34-39
    • /
    • 2017
  • Vapor-liquid equilibrium calculation is required to properly design and operation of distillation process. The general calculation method is to use binary interaction parameter. Lower flash points of cyclohexanol+aniline and cyclohexanol+cyclohexanone were measured by using Seta-flash closed cup apparatus. The measured flash points were compared with those calculated by the method based on Raoult's law and the optimization method using Wilson equation. The absolute average errors(A.A.E.) of the results calculated by Raout's law are $0.25^{\circ}C$ and $1.07^{\circ}C$ for cyclohexanol+aniline and cyclohexanol+cyclohexanone, respectively. The absolute average errors of the results calculated by the optimization method are $0.22^{\circ}C$ and $0.65^{\circ}C$ for cyclohexanol+aniline and cyclohexanol+cyclohexanone, respectively. As can be seen from A.A.E., the calculated values based on the optimization method were found to be better than those based on the Raoult's law. The binary interaction parameters calculated by the optimization method are used to predict the dew points of cyclohexanol+aniline and cyclohexanol+cyclohexanone. The A.A.E. for these mixtures show that there is an acceptable agreement between experimental and calculated dew poins.