• Title/Summary/Keyword: 인체 기준점

Search Result 76, Processing Time 0.021 seconds

A Meta-analysis of Ambient Air Pollution in Relation to Daily Mortality in Seoul, $1991\sim1995$ (메타분석 방법을 적용한 서울시 대기오염과 조기사망의 상관성 연구 (1991년$\sim$1995년))

  • Dockery, Douglas W.;Kim, Chun-Bae;Jee, Sun-Ha;Chung, Yong;Lee, Jong-Tae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.2
    • /
    • pp.177-182
    • /
    • 1999
  • Objectives: To reexamine the association between air pollution and daily mortality in Seoul, Korea using a method of meta-analysis with the data filed for 1991 through 1995. Methods: A separate Poisson regression analysis on each district within the metropolitan area of Seoul was conducted to regress daily death counts on levels of each ambient air pollutant, such as total suspended particulates (TSP), sulfur dioxide $(SO_2)$, and ozone $(O_3)$, controlling for variability in the weather condition. We calculated a weighted mean as a meta-analysis summary of the estimates and its standard error. Results: We found that the p value from each pollutant model to test the homogeneity assumption was small (p<0.01) because of the large disparity among district-specific estimates. Therefore, all results reported here were estimated from the random effect model. Using the weighted mean that we calculated, the mortality at a $100{\mu}g/m^3$ increment in a 3-day moving average of TSP levels was 1.034 (95% Cl 1.009-1.059). The mortality was estimated to increase 6% (95% Cl 3-10%) and 3% (95% Cl 0-6%) with each 50 ppb increase for 9-day moving average of SO2 and 1-hr maximum O3, respectively. Conclusions: Like most of air pollution epidemiologic studies, this meta-analysis cannot avoid fleeing from measurement misclassification since no personal measurement was taken. However, we can expect that a measurement bias be reduced in a district-specific estimate since a monitoring station is hefter representative cf air quality of the matched district. The similar results to those from the previous studios indicated existence of health effect of air pollution at current levels in many industrialized countries, including Korea.

  • PDF

Feasibility Study of Isodose Structure Based Field-in-Field Technique for Total Body Irradiation (전신조사방사선치료 시 Isodose Structure를 이용한 Field-in-Field Technique의 유용성 평가)

  • Lee, Yoon Hee;Ban, Tae Joon;Lee, Woo Seok;Kang, Tae Young;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: In Asan Medical Center, Two parallel opposite beams are employed for total body irradiation. Patients are required to be in supine position where two arms are attached to mid axillary line. Normally, physical compensators are required to compensate the large dose difference for different parts of body due to the different thicknesses compared to the umbilicus separation. There was the maximum dose difference up to 30% in lung and chest wall compared to the prescription dose. In order to resolve the dose discrepancy occurring on different body regions, the feasibility of using Fieid-in-Field Technique is investigated in this study. Materials and Methods: CT scan was performed to The RANDO Phantom with fabricated two arms and sent to Eclipse treatment planning system (version 10.0, Varian, USA). Conventional plan with physical lead compensator and new plan using Field-in-Field Technique were established on TPS. AAA (Anisotropic Analytical Algorithm) dose calculation algorithm was employed for two parallel opposite beams attenuation. Results: The dose difference between two methods was compared with the prescription dose. The dose distribution of chest and anterior chest wall uncovered by patient arms was 114~124% for physical lead compensator while Field-in-Field Technique gave 106~107% of the dose distribution. In-vivo dosimetry result using TLD showed that the dose distribution to the same region was 110~117% for conventional physical compensator and 104~107% for Field-in-Field Technique. Conclusion: In this study, the feasibility of using FIF technique has been investigated with fabricated arms attached Rando phantom. The dose difference was up to 17% due to the attached arms. It is shown that the dose homogeneity is within ${\pm}10%$ with the CT based 3-dimensional 4 step FIF technique. The in-vivo dosimetry result using TLD was showed that 95~107% dose distribution compared to prescription dose. It is considered that CT based 3-dimensional Field-in-Field Technique for the total body irradiation gives much homogeneous dose distribution for different body parts than the conventional physical compensator method and might be useful to evaluate the dose on each part of patient body.

  • PDF

Parametric Shape Modeling of Femurs Using Statistical Shape Analysis (통계적 형상 분석을 이용한 대퇴골의 파라메트릭 형상 모델링)

  • Choi, Myung Hwan;Koo, Bon Yeol;Chae, Je Wook;Kim, Jay Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.10
    • /
    • pp.1139-1145
    • /
    • 2014
  • Creation of a human skeleton model and characterization of the variation in the bone shape are fundamentally important in many applications of biomechanics. In this paper, we present a parametric shape modeling method for femurs that is based on extracting the main parameter of variations of the femur shape from a 3D model database by using statistical shape analysis. For this shape analysis, principal component analysis (PCA) is used. Application of the PCA to 3D data requires bringing all the models in correspondence to each other. For this reason, anatomical landmarks are used for guiding the deformation of the template model to fit the 3D model data. After subsequent application of PCA to a set of femur models, we calculate the correlation between the dominant components of shape variability for a target population and the anatomical parameters of the femur shape. Finally, we provide tools for visualizing and creating the femur shape using the main parameter of femur shape variation.

항균제 임상시험 Guideline

  • 우준희
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1994.11a
    • /
    • pp.27-30
    • /
    • 1994
  • 잠재적으로 항감염 약제로 사용될 가능성이 있는 약제들의 초기 연구과정에서 주된 관심사는 이들이 미생물(세균, 바이러스, 기타 기생충)에 대한 작용들이 있는가 하는 점이다. 이러한 작용들이 실험적으로 충분히 연구가 된 후에야 실험동물에서 그 효과를 연구한다. 항 바이러스 제제의 경우에는 세포배양을 통한 연구가 그 약제의 독성과 효용성을 나타내는데 필수적인 것이 된다. 여러 종류의 동물을 이용한 생체실험에서 약제의 일반적인 흡수와 배설, 분포 등에 관한 정보와 약제 자체와 동물 내에서의 대사적 변화에 대한 정보가 제공된다. 여러 가지 미생물로 감염을 시킨 적합한 동물과 여러 가지 용량으로 치료하는 실험을 통하여 약제의 항 감염 능력이 알려지게 된다. 동물에서의 생체실험과 실험관내에서 실험을 하고 나서야 사람에서의 연구가 이루어지게 된다. 소위 전임상시험에서 대표적 병원성 미생물에 대한 생물학적효과, 약리학적 효과와 독성 그리고 동물실험모델에서의 가능한 효과가 결정된 후에 임상시험에 들어가기 마련이다. 항균제의 임상시험에는 각각의 감염질환에 대한 진단 및 치료기준을 반영하는 것이 기본이다. 새로운 항균제의 임상시험에서는 안전성과 효과가 반드시 밝혀져야 한다. 1상에서는 인체에서의 약리효과, 안전성이 주목적이며, 2상과 3상은 겹쳐지는 점도 있으나 하나 또는 그 이상의 적응증에 대한 항균제의 효과와 단기간의 부작용은 2상에서 관찰하여야하며, 다수의 환자에서 제안된 적응질환의 무작위임상시험과 다수에서의 안전성도 3상에서 관찰하여야 한다. 4상에서는 이상에서의 자료로 시판된 후에도 계속해서 감시하는 것으로 지속적으로 안전성을 관찰하는 것이다. 이러한 기본사항외에도 소아, 임산부, 고령자등에서의 임상시험도 넓은 의미에서 포함되어야 할 것이며 또한 질적인 면에서 조절하는 Quality Assurance도 중요하다.양상은 세 용량군 간 차이가 없었으나, 시험기에서 발열의 발현율이 낮았으며, 발열일 수와 항생제 사용일 수가 짧았다. 결론: 골수억제 조절 효과는 용량에 따른 혈액소견에 미치는 영향, 부작용, 감염의 빈도, 감염발생에 따른 항생제 사용기간 등을 고려하여 그 임상 유효성 평가시, 제 3상 시험에 사용할 권장량 (recommended dose) 은 250 ug/$m^2$/d $\times$ 10d 으로 관찰되었다.5주에 부검한 랫드의 간에서 c-myc 종양단백의 발현은 모든 처리군들이 대조군에 비하여 높게 발현되는. 것이 관찰되었으나 시험개시후 26주에 부검한 랫드의 간에서 c-myc 종양단백의 발현은 대조군에 비하여 차이가 거의 없었다. 따라서 랫드에서 화학적으로 유도한 간암발생 과정에서 NK 세포활성이 현저하게 억제되는 것으로 생각되며, c-myc 종양단백의 발현은 시험개시후 15주에 그 발현이 확실한 것으로 사료되어 진다.에 영향을 주는 성분이 있음을 제시하였다.1과 항우울약들의 항혈소판작용은 PKC-기질인 41-43 kD와 20 kD의 인산화를 억제함에 기인되는 것으로 사료된다.다. 것으로 사료된다.다.바와 같이 MCl에서 작은 Dv 값을 갖는데, 이것은 CdCl$_{4}$$^{2-}$ 착이온을 형성하거나 ZnCl$_{4}$$^{2-}$ , ZnCl$_{3}$$^{-}$같은 이온과 MgCl$^{+}$, MgCl$_{2}$같은 이온종을 형성하기 때문인것 같다. 한편 어떠한 용리액에서던지 NH$_{4}$$^{+}$의 경우 Dv값이 제일 작았다. 바. 본 연구의 목적중의 하나인 인체유

  • PDF

Evaluation of the Breast plan using the TLD and Mosfet for the skin dose (열형광선량계(TLD)와 MOSFET을 이용한 유방암 방사선치료계획에 대한 피부선량 평가)

  • Kim, seon myeong;Kim, young bum;Bak, sang yun;Lee, sang rok;Jeong, se young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.107-113
    • /
    • 2015
  • Purpose : The measurement of skin dose is very important that treatment of breast cancer. On account of the cold or hot dose as compared with prescription dose, it is necessary to analyse the skin dose occurring during the various plan of the breast cancer treatment. At our hospital, we want to apply various analyses using a diversity of dosimeters to the breast cancer treatment. Subjectss and Methods : In the study, the anthropomorphic phantom is used to find out the dose difference of the skin(draining site), scar and others occurring from the tangential treatment plan of breast cancer. We took computed tomography scan of the anthropomorphic phantom and made plans for the treatment planing using open and wedge, Field-in-Field, Dose fluence. Using these, we made a comparative analysis of the dose date points by using the Eclipse. For the dose comparison, we place the anthropomorphic phantom in the treatment room and compared the measurement results by using the TLD and MOSFET on the dose data points. Results : On the central point of treatment planing basis, the upward and downward skin dose measured by the MOSFET was the highest when the fluence was used. The skin dose of inner and outer was distinguished from the figure(5.7% ~ 10.3%) when the measurements were fulfilled by using TLD and MOSFET. The other side of breast dose was the lowest in the open beam, on the other hand, is highest in the Dose fluence plan. In the different kinds of treatment, the dose deviation of inner and outer was the highest, and so this was the same with the TLD and MOSFET measurement case. The outer deviation was highest in the TLD, and the Inner'was highest in the MOSFET. Conclusion : Skin dose in relation to the treatment plan was the highest in the planing using the fluence technique in general and it was supposed that the high dose had been caused by the movement of the MLC. There's some differences among the all the treatment planning, but the sites such as IM node occurring the lack of dose, scar, drain site are needed pay close attention. Using the treatment planning of dose fluence is good to compensate the lack of dose, but It increases the dose of the selective range rather than the overall dose. Therefore, choosing the radiotherapy technique is desirable in the lights of the age and performance of the patient.

  • PDF

Radiation Dose of Lens and Thyroid in Linac-based Radiosurgery in Humanoid Phantom (선형가속기형 방사선수술시 인형 팬텀에서 수정체 및 갑상선 선량)

  • Kim, Dae-Yong;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.517-529
    • /
    • 1998
  • Purpose : Although many studies have investigated the dosimetric aspects of stereotactic radiosurgery in terms of target volume, the absorbed doses at extracranial sites: especially the lens or thyroid - which are sensitive to radiation for deterministic or stochastic effect -have infrequently been reported. The aim of this study is to evaluate what effects the parameters of radiosurgery have on the absorbed doses of the lens and thyroid in patients treated by stereotactic radiosurgery, using a systematic plan in a humanoid phantom. Materials and Methods : Six isocenters were selected and radiosurgery was planned using the stereotactic radiosurgery system which the Department of Therapeutic Radiology at Seoul National University College of Medicine developed. The experimental radiosurgery plan consisted of 6 arc planes per one isocenter, 100 degrees for each arc range and an accessory collimator diameter size of 2 cm. After 250 cGy of irradiation from each arc, the doses absorbed at the lens and thyroid were measured by thermoluminescence dosimetry. Results : The lens dose was 0.23$\pm$0.08$\%$ of the maximum dose for each isocenter when the exit beam did not pass through the lens and was 0.76$\pm$0.12$\%$ of the maximum dose for each isocenter when the exit beam passed through the lens. The thyroid dose was 0.18$\pm$0.05$\%$ of the maximum dose for each isocenter when the exit beam did not pass through the thyroid and was 0.41$\pm$0.04$\%$ of the maximum dose for each isocenter when the exit beam Passed through the thyroid. The passing of the exit beam is the most significant factor of organ dose and the absorbed dose by an arc crossing organ decides 80$\%$ of the total dose. The absorbed doses of the lens and thyroid were larger as the isocenter sites and arc planes were closer to each organ. There were no differences in the doses at the surface and 5 mm depth from the surface in the eyelid and thyroid areas. Conclusion : As the isocenter and arc plane were placed closer to the lens and thyroid, the doses increased. Whether the exit beams passed through the lens or thyroid greatly influenced the lens and thyroid dose. The surface dose of the lens and thyroid consistently represent the tissue dose. Even when the exit beam passes through the lens and thyroid, the doses are less than 1$\%$ of the maximum dose and therefore, are too low to evoke late complications, but nevertheless, we should try to minimize the thyroid dose in children, whenever possible.

  • PDF

Utilization of Tissue Compensator for Uniform Dose Distribution in Total Body Irradiation (전신방사선조사시 균등한 선량분포를 이루기 위한 조직보상체의 이용)

  • Park, Seung-Jin;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Nah, Byung-Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.233-241
    • /
    • 1994
  • Purpose : This study was performed to verify dose distribution with the tissue compensator which is used for uniform dose distribution in total body irradiation(TBI). Materials and methods : The compensators were made of lead(0.8mm thickness) and aluminum(1mm or 5mm thickness) plates. The humanoid phantom of adult size was made of paraffin as a real treatment position for bilateral total body technique. The humanoid phantom was set at 360cm of source-axis distance(SAD) and irradiated with geographical field size(FS) $144{\times}144cm^2(40{\times}40cm^2$ at SAD 100cm) which covered the entire phantom. Irradiation was done with 10MV X-ray(CLINAC 1800, Varian Co., USA) of linear accelerator set at Department of Therapeutic Radiology, Chonnam University Hospital. The midline absorbed dose was checked at the various regions such as head, mouth, mid-neck, sternal notch, mid-mediastinum, xiphoid, umbilicus, pelvis, knee and ankle with or without compensator, respectively. We used exposure/exposure rate meter(model 192, Capintec Inc., USA) with ionization chamber(PR 05) for dosimetry, For the dosimetry of thorax region TLD rods of $1x1x6mm^3$ in volume(LiF, Harshaw Co., Netherland) was used at the commercially available humanoid phantom. Results : The absorbed dose of each point without tissue compensator revealed significant difference(from $-11.8\%\;to\;21.1\%$) compared with the umbilicus dose which is a dose prescription point in TBI. The absorbed dose without compensator at sternal notch including shoulder was $11.8\%$ less than the dose of umbilicus. With lead compensator the absorbed doses ranged from $+1.3\%\;to\;-5.3\%$ except mid-neck which revealed over-compensation($-7.9\%$). In case of aluminum compensator the absorbed doses were measured with less difference(from $-2.6{\%}\;to\;5.3\%$) compared with umbilicus dose. Conclusion : Both of lead and aluminum compensators applied to the skull or lower leg revealed a good compensation effect. It was recognized that boost irradiation or choosing reference point of dose prescription at sternal notch according to the lateral thickness of patient in TBI should be considered.

  • PDF

The Study on Risk Factors Analysis and Improvement of VDT Syndrome in Nuclear Medicine (핵의학과 Video Display Terminals Syndrome 유해 요인 조사 및 개선에 관한 연구)

  • Kim, Jung-Soo;Kim, Seung-Jeong;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo;Han, In-Im;Joo, Yung-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • Purpose: Recently, Department of Nuclear Medicine have an interest in Video Display Terminals (VDT) syndrome including musculoskeletal disorders, ophthalmologic disorders, trouble of electromagnetic waves and stress disorders occur to VDT workers as the growing number of users and rapid pace of service period supply in large amount. This study research on the actual condition for VDT syndrome in Nuclear Medicine, Seoul National University Hospital (SNUH), discover the problem and draw a plan of upcoming improvement. The aim of this study establish awareness about VDT syndrome and is to prevent for it in the long run. Materials and Methods: Department of Nuclear Medicine, SNUH is composed Principle part, Pediatric part and PET center. We estimated risk factors visit in each part directly. Estimation method use "Check list for VDT work" of Wonjin working environment health laboratory and check list is condition of VDT work, condition of work tables, condition of chairs, condition of keyboards, condition of monitors, working position, character of health management and other working environment. Analysis result is verified in Department of Occupational and Environment, Hallym University Sacred Heard Hospital. Results: As a result of analysis, VDT condition of Department of Nuclear Medicine, SNUH is rule good. In case of work tables, recent of things are suitable to users upon the ergonomical planning, but 15% of existing work tables are below the standard value. In case of chairs are suitable, but 5% of theirs lost optimum capacity become superannuated. The keyboards are suitable for 98% of standard value. In case of monitors, angle control of screen is possible of all, but positioning control is impossible for 38%. In case of working position, 10% is fixed positioning for long time and some of the items researched unsuitable things for standard. At health management point, needed capable of improvement. Also, other working condition as lighting, temperature, noise and ventilation, discovered the problem, but is sufficient to advice value. Conclusion: VDT syndrome is occurrences of possibility continuously, come economical expensive about improvement, is inherent in various causes and originate without your knowledge. So, there is need systematic management system. In Nuclear Medicine, VDT syndrome make it better that constant interest and effort as improvement of ergonomical working environment, improvement of working procedure, regular exercise and steady stretching, and can be prevented fairly. This promote physical and mental condition of worker in top form in comfortable working environment, so this is judged by enlargement of operations efficiency and rising of satisfaction ratings of the inside client.

  • PDF

Study on Uncertainty Factors of Head Vibration Measurements (머리 진동 측정치의 불확도 인자들에 관한 연구)

  • Cheung, Wan-Sup;Kim, Young-Tae;Ryu, Je-Dam;Hong, Dong-Pyo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.1 s.94
    • /
    • pp.20-28
    • /
    • 2005
  • This paper addresses uncertainty issues encountered recently in measuring head vibration using the conventional 6-axis or 9-axis bite-bar model. Those conventional bite-bar models are shown to present insufficient information to evaluate a generalized motion of head vibration. In order to overcome such limit, a new theoretical measurement model that consists of four 3-axis linear accelerometers is suggested. It is shown to enable the measurement of three angular acceleration components and six second-order angular velocity-dependent terms. Those nine angular motion-related ones, in addition to the three linear acceleration terms at the origin, are found to make it possible to evaluate the generalized head vibration for a given position. To examine the feasibility of the proposed method, a newly designed 12-axis bite-bar was developed. Detailed experimental results obtained from the developed 12-axis bite-bar are demonstrated in this paper. They illustrate that the popular 6-axis bite-bar model yield about $4.0\%$ relative measurement uncertainty for the pitch component of head vibration, $14\%$ and $10\%$ relative measurement uncertainty for the roll and yaw components of head vibration, respectively. Furthermore, this paper proposes other uncertainty factors to be considered in the future.

Monitoring of Pesticide Residues in Green Tea produced in Korea (국내산 녹차의 잔류농약 모니터링)

  • Kim, Hee-Yun;Jeon, Jong-Sup;Kim, Yong-Hoon;Choi, Hee-Ju;Cheong, So-Young;Lee, Hwa-Jeong;Kim, Jae-In;Kim, Young-Seon;Choi, Gye-Sun;Choi, Jae-Chun
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.5
    • /
    • pp.483-489
    • /
    • 2009
  • Herein, we present the results of our investigation of 61 pesticide residues in 100 samples of green teas obtained from Korean markets. Bifenthrin, chlorpyrifos, dicofol, EPN, chlorfenapyr, tebuconazole, cyhalothrin, difenoconazole, and tebufenpyrad were detected in 22 of the 100 green tea samples. The quantity of pesticide residues for bifenthrin was 0.12 ppm (maximum residue limits (MRLs): 0.3 ppm) in one sample, chlorpyrifos was 0.24-0.78 ppm (MRLs: 2.0 ppm) in three samples, dicofol was 1.64-4.19 ppm (MRLs: 50.0 ppm) in two samples, EPN was 0.13 ppm (MRLs: 0.05 ppm) in one sample, chlorfenapyr was 0.01-1.23 ppm (MRLs: 3.0 ppm) in 16 samples, tebuconazole was 0.71 ppm (MRLs: 5.0 ppm) in one sample, cyhalothrin was 0.05-0.3 ppm (MRLs: 2.0 ppm) in five samples, difenoconazole was 0.23 ppm (MRLs: 2.0 ppm) in one sample, and tebufenpyrad was 0.06-0.07 ppm (MRLs: 2.0 ppm) in two samples. More than two pesticide residues were detected in seven samples. All detected pesticide residues (with the exception of EPN) were within the MRLs.